FRACTION COLLECTOR. Microcomputer Controlled CHF122SC



Similar documents
IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Mitos P-Pump. product datasheet

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Physical Specifications (Custom design available.)

2.24. Pump Controller 704. Data Sheet

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PIEZOMETER AIRFLOW MEASURING RING

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Centro-Matic Automatic Lubrication Systems System Controls

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Purification of reaction mixtures using flash chromatography.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

ORGANIC SAMPLE PREPARATION

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

DENSITY MEASURING SYSTEMS

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Assisted lift operated 2/2-way solenoid valves Type EV250B

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

MANUAL PC1000R

Protocol: HPLC (amino acids)

Duct Humidity Transmitter

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version

HEAVY WATER LEAK DETECTOR

Guide rail bracket (for adjustable heads)

NC-12 Modbus Application

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Laboratory Autoclave SN210/310/510,SQ510/810

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

BW-500 BED WEIGHER USER MANUAL

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Multifunction devices

FT-100 Fire Training Fog Machine User Manual English

Cable Plug acc. to DIN EN , Form A

Online Infrared Flue Gas Analyzer Gasboard 3000

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

Testomat AW101 Water Hardness Monitor. A unique water hardness monitoring system with superior performance

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

User's Guide. Integrating Sound Level Datalogger. Model Introduction

GSM HOME SECURITY SYSTEM

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Parison Controller. Operation Manual

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Senses SV series industrial monitor user manual

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

MS9000SAN Rework Station

Robot soldering head 4900

EMR-9 Quick Start Guide (00175)D 1

ROTOFIX 32 A Benchtop Centrifuge

INSTRUCTIONS Edition AC

Symmetry in Diagnostics HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. TOSOH BIOSCIENCE

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Model 4510 Conductivity/TDS Meter Operating Manual

Freezers - Ultrafreezers. Platilab & Irilab Series

ENAiKOON ultrasonic fuel-level sensor

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Please also see 10 golden rules for correct Saniflo installation on

Instruction Manual. T3111 T3111L T3111P T3111Ex

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Gas Chromatography Liner Selection Guide

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

24 Wide Screen LED Monitor with HDMI

SMD Rework Station TABLE OF CONTENTS

ÄKTA system Training Guide

GSM Autodialer Professional GJD700 Speech & Text Autodialer

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Digital input modules

Power consumption (kw)

6 Crankcase Ventilation

Model DE-3 Air Release Head

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Connect Alias autosampler to ÄKTA pure or ÄKTA avant. Instructions

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION

How To Test For Contamination In Large Volume Water

Revision History. Date Page Summary. Approved By: Document Number: OG24161 r.0 Page 1 of 11

Temperature & Humidity SMS Alert Controller

TMS TANK MANAGEMENT SYSTEM

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Transcription:

FRACTION COLLECTOR Microcomputer Controlled CHF122SC

From open column to HPLC liquid chromatography and general liquid samplings, the Super Fraction Collector, model CHF122SC has a wide range of uses. The CHF122SC is a fraction collector with increased reliability, employs an X-Y movement mechanism based on long years of technological accumulation, a new vertical movement apparatus and a large display screen for easier use than ever. The CHF122SC holds up to 120 vessels, and can handle a variety of vessel diameters and lengths. With its numerous fraction functions, the CHF122SC boasts a wide range of applications. Main body and standard rack Features Easier operation with a large display screen With 9 operation keys and a large 40 characters x 8 row display screen, it is easier than ever to input programming and parameter settings. The graph display of chromatography signals makes it easy to determine the status of fraction collection. Reliable construction The water-sensitive operation panel as well as the mechanical and electronic parts are placed behind the test tube rack to protect against water droplets for a practical, long-lasting design. Supports different sized collection vessels The vertical dial allows 70 mm of movement to adjust the dropper nozzle position to the test tube length (105 ~ 180mm). The standard test tube rack will hold 120 tubes with a diameter of 12 ~15mm (maximum of 18.1 mm with the standard rack holder removed). Large volume vessels can be set when the rack lid is removed. For collecting big bottles Quick nozzle movement with higher resolution A sturdy frame and higher resolution stepping motor are used. The nozzle moves accurately to the set position, from tube to tube in 0.1 seconds. Unneeded constituents drained Waste constituents are drained out so test tubes are not unnecessarily contaminated. Safe, chemically resistant material The exterior of the unit is made of flame retardant ABS plastic, and the test tube rack and drain are made of chemically resistant polypropylene. Simple up-and-down movement Drain Up/Down knob

Loaded with Unique Collection Functions Simple mode: Collect by time, drops, volume or signal. Peak Mode: Specify up to a maximum of 10 peaks for identification. Peak determination may be made using a combination of absolute value and slope angle. Example of slope angle setting As shown in the graph at right, because of base line drift, only three peaks are Example of peak absolute value setting Set the identified at 1, 2/3 and 4/5/6/7/8 by absolute value setting. percent value using an input signal full scale of 100%. However, by using a slope setting, all 8 peaks are identified. Peaks above the set absolute value are identified. Window mode A maximum of 16 windows (time ranges) may be set so that peaks are identified and fraction collection occurs only within each window. By setting the monitor time, non-peaks may also be collected in the test tubes. Window mode setting, example 1 Window 1 is set between 2min00sec and 2min32sec at request time of 12sec. Window 2 is set between 3min32sec and 5min00sec at 8 sec request time. Main settings Window settings Peak parameters Wait time: [40 sec] Non-window monitor time: [0 sec] 01: Start [2min00sec] ~ End [2min32sec] Request time [12 sec] 02: Start [3min32sec] ~ End [5min00sec] Request time [8 sec] Absolute value: [0%], Slope angle: [0mv/min] Response: [*HIGH], Delay time: [0 sec] Window mode setting, example 2 (peak identification) Peaks within the windows are identified. Fraction collection is set at 12 seconds during peaks for window 1. For non-peaks, the monitor time interval is 8 seconds. Main settings Window settings Peak parameters Wait time: [40 sec] Non-window monitor time: [0 sec] 01: Start [2min00sec] ~ End [2min32sec] Request time [12 sec] Monitor [08 sec] 02: Start [3min32sec] ~ End [5min00sec] Request time [8 sec] Monitor [24 sec] Absolute value: [40%] Slope angle: [20 mv/min] Response: [*HIGH] Delay time: [0 sec] Manual mode Collect fractions while watching the chromatography signals displayed on the screen. A fraction may be reviewed under playback mode. Sampling mode Collect fractions for a set interval during a set period. Multiple collections may be set per test tube. In the setting example shown on the right, wait time is 5 minutes, each test tube has 2 repeats of 5 minutes intervals every 15 minutes. Wait Monitor Request Vessel # Wait Monitor Request Vessel # Setting Example = Sampling Mode

Fraction result display Multiple sample functions After a fraction collection has completed, the next fraction sampling begins at the next test tube or after skipping one tube. Synchronize the chromatogram and collection using the time delay function Because of the distance from the UV absorption detector, refractometer or other instruments to the fraction collector dispense nozzle, there is a delay from the point of graphing until the sample is collected in the tube. By inputting the lag time, the collected sample can be set to accurately conform to the record (chromatogram). Peak signal graph display Verify the fraction collection results by looking at the graph The results of up to 500 events can be displayed. Chromatography signals are displayed in peak, window and manual modes. Operate using a computer Using a computer, the parameter settings for each mode as well as starting, ending, pausing and advancing can be controlled. By loading up to 500 fraction results into the computer, the operation history of the equipment and test results can be easily verified. Sample liquid chromatography system set-up After inserting the sample into the top of the column, the elute separates out. While characteristics are measured with detectors, the separated substances are eluted into the fraction collectors. Example of sampling system set-up A small amount is sampled at a fixed interval, and inserted into the fraction collectors.

CHF122SC Accessories CH000754 CH000760 CH000770 CH000780 CH000790 Optional racks and rack accessories Non -standard test tube racks available. 96 well microplate Rack 27.5 mm vial Rack 16.5 mm vial Rack Test tube Rack (without holder) for 15 mm OD and up test tube Test tube Rack (with 12 mm OD holder) for 12 mm OD test tube CH000754 CH000760 CH000770 CH000780 CH000790 96 well microplate * Microplates, scintillation vials and test tubes are not included with racks. CH000730 Eppendorf tube adapter Use to adapt the standard test tube rack to Eppendorf tubes Model Max. no. of fractions 120 Useable test tubes Material Dimensions Product CH000740 Model Vessels Holding qty CH000800 27.5 mm (OD) X 57 mm scintillation vials 16.5 mm (OD) x 54 mm scintillation vials 15 18.1 mm (OD) x 105 180 mm (L) test tubes 12 mm (OD) x 105 180 mm (L) test tubes Product Model Specifications 12 mm holder CH000730 Test Tube rack (12 mm OD holder), holds 30 12-mm test tubes Rack middle plate 1.5 ml (40 mm high, 11 mm body circumference) Stainless steel 275 (w) x 248 (d) x 115 (h) mm CH000740 CH000800 * Test tube rack and Eppendorf tubes are not included with the Eppendorf tube adapter. Preparative Options Prep. Funnel (CH000160) and Prep. Funnel Rack (CH000845) allow the end user to collect fractions in large volume containers. Product Model Specifications CH000160 Prep. Funnel CH000160 30 fraction funnels in each CH000160 Prep. Funnel Rack CH000845 Holds up to 3 CH000160s (3x30 pos.) Prep. Tygon Tubing CH000180US TYGON TUBE (6.35X9.52mm) X 5M) Prep. Mobile Cart CH000115 Cut out hole on the Top table 4 56 120 120 120 Place in the test tube rack (standard, 15 mm OD or larger, or 12 mm OD) to allow use of 35~105 (L) mm tubes. 3-Way diverter valve Prevent the sample from spillage out from the tubes while the nozzle is in transit. Also, use the included seal adapter to use the valve as a stop valve. May be set to drain to prevent residual sample in the valve from the previous peak from being mixed in with the next fraction. The 3-way valve CH000710 has a low residual volume to decrease contamination. CH000700 CH000710 Product 3-Way diverter valve Low residual 3-Way valve Model CH000700 CH000710 Inlet pressure 300 kpa (40.5psi) 200 kpa (29psi) Connector Material PTFE, PCTFE IN 26 14 Residual volume (µl) NC NO 66 66 7 7 Power consumption 2.2 VA max. * The CH000710 has a flow volume approximately 40% less than the CH000700.

Specifications Model CHF122SC Test tube quantity 120 tubes (12 ~ 18.1 mm OD x 105 ~ 180 mm L) (remove tube holders for larger than 15 mm OD) Operation modes Collection methods Nozzle shift time Simple, Peak, Window, Manual, Sampling By Time, Drop count, Drop volume, Signal 0.1 sec (tube center to center) Modes of Operation Simple mode Time: 99 min 59 sec / tube max. Drop: 9999 count / tube max. Volume: 999.9 ml / tube max. Signal: 9999 count / tube max. Vessel parameter specifications Rack selection Standard test tube Rack (CH000670) Eppendorf tube Rack (CH000800) Scintillation vial (16.5mm) Rack (CH000770) Scintillation vial (27.5mm) Rack (CH000760) Microtiter plate (96well x4) Rack (CH000754) Prep. Funnel (CH000160) Rack (CH000845) Bottle position arrangement Bottle arrangement Matrix arrangement: 2 patterns Arbitrary arrangement: 1 pattern Regular arrangement Arbitrary arrangement Max. 12 rows x 15 columns (120 pos. max.) Max. 100 positions Peak mode: End time: 999 min max. Request time: 99 min 59 sec / tube max. Monitor time: 99 min 59 sec / tube max. Fraction peak: Up to 10 out of 99 peaks Peak discrimination: Absolute value 100% max. Slope 99.99mV/min or 9.999mV/min max. Signal response: Chromoto. signal sampling High: 0.5 sec Low: 3 sec External signals Event marker Chromato, signal input External start input External end input 2 contact point output circuits: 1. Pulse signals 2. Level signals 10 mv or 1 V full scale ON START ON END Window mode Non-window monitor: 99 min 59 sec max. No. of windows: 16 max. Start/end time: 999 min 59 sec max. Request/Monitor time: 99 min 59 sec / tube max. Peak specifications: Same as in peak mode Manual mode Learning response: Chromato. signal display High: 0.5 sec Low: 3 sec. Playback: Replay results of learning Sampling mode Interval: 99 min 59 sec max. Collection time: 99 min 59 sec max. Collection volume: 999.9 ml max. No. of repeats: 99 max. Common Wait time: 999 min 0 sec max. parameters for Simple, Peak, Window and Sampling modes Delay time: 9 min 59 sec max. for Peak, Window and Manual modes External count input Serial interface ON COUNT RS-232C (9-pin connector) Accessories Test tube rack CH000670 (1) Drain (1) Dust cover (1) I/O terminal connector (1) Sample tubing: PTFE 2 mm OD x 1 mm ID x 1 M (1) Drain tubing: Silicon 8 mm OD x 5 mm ID x 0.5 M (1) Tube Suspender (2) Power cord (1) Installation & Operation Manual (1) General electrical specifications Clock Quartz oscillation Operation Display 40 characters x 8 rows (LCD w/backlight) Multi-sample: Possible in Simple, Peak and Window modes. Equipment parameter specifications Volume collection Collection time (min) = Flow volume (ml) / flow rate (ml/min) Parameter memory Temperature range Power Battery back-up 2 ~ 40 C ( 35 ~104 F) AC 100 V, 115 V, 240 V, 0.23 A max. Multi-sample Skip one vessel or continuous (Non-skip) External dimensions 286 (w) x 387 (d) x 335 (h) mm Marker (2) Power failure ON after operation (assembled with I/O extension unit, pumps stops after operation) or OFF Display On or Off RS-2323C Baud rates 1200, 2400, 4800 Characters: 8-bit, Parity: None, Stop: 2-bit Weight Approx. 7 kg (15.4 lbs) Replacement items Product Model Material/specs Test Tube rack CH000670 Polypropylene Drain CH000680 Polypropylene Dust Cover CH000691 PVC Tube Support (12~15mm) CH000720 for CH000670, (30 holders/pk) 6723 Sierra Court, Suite A, Dublin, California 94568 U.S.A. Tel (925) 479-0625, 800-334-7132, Fax (925)479-0630 www.advantecmfs.com CHF1220604