INSPECTION AND TESTING FORM



Similar documents
~SIEMENS SIEMENS BUILDING TECHNOLOGIES, INC. FIRE SAFETY DIVISION

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM INSPECTION AND TESTING FORM

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

Michael Catalano 24 Nassau Avenue, Islip NY Phone (631) Chief Fire Marshal Fax (631)

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

AETNA FIRE ALARM SERVICE CO., INC.

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

INSPECTION AND TESTING OF FIRE ALARM SYSTEMS

FIRE ALARM APPLICATION

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

HERNANDO COUNTY FIRE ALARM GUIDELINES

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

CHAPTER. Fire Alarm Systems APPROVAL AND ACCEPTANCE. Shop Drawings

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

Module 4, Lesson 12 Fire Alarm Systems

1.0 General. Inspection, Testing, and Maintenance 1 of 8

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

EXHIBIT A SCOPE OF WORK

Module 5. Fire and Emergency Alarm System Part I- Basics

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

PLAN REVIEW GUIDE FOR FIRE ALARM

Fire Alarm Systems Certification

DTW Works Master Specification Version 2006

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

Fire Prevention Coffee Break Training. November 2015

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

The Evolution of Requirements for Supervising Station Alarm Systems

BASIC FIRE ALARM TRAINING

Bold items are particular to the City of Euless

Fire Alarm System Monitoring - CAN/ULC-S561-03

NATIONAL FIRE ALARM AND SIGNALING CODE

Fire Alarm System Plans Review Checklist Property location Date of Review

C. Conform to requirements of Americans with Disabilities Act (ADA).

Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) Fire Alarm Permit Application

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

ENVIRONMENTAL HEALTH & SAFETY 6 East Dr., Amherst MA

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Loop Start or Ground Start?

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

Commercial Fire Alarm Standards July 1, 2010 Edition Page 1 of 14

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET

Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

City of Bettendorf Fire Alarm System Requirements

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

FIRE ALARM SYSTEM PLAN SUBMITTAL CHECKLIST

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

NY Fire Safety Institute

The Mission Critical Fire Protection Experts

Carbon Monoxide Detection in Commercial Buildings (

ERS-2400B. PERS-2400B Personal Emergency Reporting System

ENGINEERING SPECIFICATIONS

B. NICET: National Institute for Certification in Engineering Technologies.

Design Standards Fire Alarm Systems Division (1995 CMS); (2004 CMS) Amended Feb 2015

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

COMMISSIONING OF FIRE ALARM SYSTEMS

SECTION FIRE ALARM AND DETECTION SYSTEM

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

FIRE DETECTION AND ALARM

JULY 2013 UCB STANDARDS

SECTION FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

SECTION FIRE ALARM AND DETECTION SYSTEMS

SECTION DETECTION AND ALARM

BERMAD Fire Protection

Agenda. Agenda (continued) Fundamentals of Fire Alarm Systems

BERMAD Fire Protection

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

FIREFINDER XLS ADDRESSABLE FIRE ALARM SYSTEM SECTION 13851

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Fire Alarm Trainee Log Book

NFPA 72. Exception No. 1: Where ambient conditions prohibit installation of automatic smoke detection, automatic heat detection shall be permitted.

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

2007 ICC FINAL ACTION AGENDA

NYC Department of Education Building Condition Assessment Survey :37AM :14AM. Description

University of Houston Master Construction Specifications Insert Project Name

1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri.

LIFE CYCLE COST ANALYSIS OF ELECTRONIC C58655 Page 1 MONITORING OF PORTABLE EXTINGUISHERS January 3, 2013 DRAFT FINAL

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

FIRE SAFETY INSPECTION REPORT

FIRE-FIGHTING DESIGN BRIEF REPORT

2012 Ontario Building Code Changes Affecting Fire Alarm Systems

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Lighting and Fire Alarm Training System Add-On

SPECIFICATION FOR A TOTAL FLOOD HFC-227ea CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE Cheetah Xi CONTROL PANEL SYSTEM

University Design Standard. Fire Alarm Systems

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

Transcription:

INSPECTION AND TESTING FORM SERVICE ORGANIZATION PROPERTY NAME (USER) DATE: 08-04-15 TIME: 8:00 Name: Siemens Industries Inc. Name: Kcvtcs Madisonville Tech, School Bldg. Address: 2700 Stanley Gault Pkwy Louisville, Kentucky 40223 Address: 150 School Road Madisonville, Kentucky 42431 Representative: Martin Hinkle Owner Contact: Donald Frasier License No.: FAR-1458 Telephone: (270) 821-0149 Telephone: (502) 267-1571 MONITORING ENTITY APPROVING AGENCY Contact: None Contact: Telephone: Telephone: Monitoring Account Ref. No.: TYPE TRANSMISSION McCulloh Multiplex Digital Reverse Priority RF Shunt Parallel Phone þ None Other (Specify) SERVICE Weekly Monthly Quarterly Semiannually þ Annually Other (Specify) Control Unit Manufacturer: Simplex Model Number: 4246-1 Circuit Styles: Class B Number of Circuits: 1 Software Rev.: N/A Last Date System Had Any Service Performed: Last Date that Any Software or Configuration Was Revised: QUANTITY ALARM-INITIATING DEVICES AND CIRCUIT INFORMATION CIRCUIT STYLE 7 Style 4 Manual Pull Station 9 Style 4 Heat Detector Alarm Verification Feature is Disabled Enabled X (NFPA Inspection and Testing, 1 of 6)

QUANTITY ALARM NOTIFICATION APPLIANCES AND CIRCUIT INFORMATION CIRCUIT STYLE 7 Style Y Horn/Strobes Number of alarm notification appliance circuits: 1 Are circuits monitored for integrity? Yes SUPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUIT INFORMATION QUANTITY CIRCUIT STYLE SIGNALING LINE CIRCUITS Quantity and style of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity 0 Style(s) SYSTEM POWER SUPPLIES (a) Primary (Main): Nominal Voltage 120 Amps 20 Overcurrent Protection: Type Breaker Amps 20 Location (of Primary Supply Panel Board): Main Office Rm. 104 Disconnecting Means Location: Electrical Room (b) Secondary (Standby): Storage Battery: Amp-Hour Rating N/A Calculated Capacity to operate system, in Hours: 24 60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: TYPE BATTERY Dry Cell Nickel-Cadmium Sealed Lead-Acid Lead-Acid Other (Specify): (c) Emergency or Standby system used as a backup to primary power supply, instead of using a secondary power supply: Emergency system described in NFPA 70, Article 700. Legally required standby described in NFPA 70, Article 701. Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701. (NFPA Inspection and Testing, 2 of 6)

PRIOR TO ANY TESTING NOTIFICATIONSARE MADE YES NO WHO TIME Monitoring Entity N/A Building Occupants þ All Building Management þ Donald Frasier Other (Specify) AHJ Notified of Any Impairments SYSTEM TESTS AND INSPECTIONS TYPE VISUAL FUNCTIONAL COMMENTS Control Unit þ þ Interface Equipment Lamps/LEDS þ þ Fuses þ þ Primary Power Supply þ þ Trouble Signals Disconnect Switches Ground-Fault Monitoring SECONDARY POWER TYPE VISUAL FUNCTIONAL COMMENTS Battery Condition None Load Voltage Discharge Test Charger Test Specific Gravity Transient Suppressors Remote Annunciators NOTIFICATION APPLIANCES VISUAL FUNCTIONAL COMMENTS Audible þ Visual þ Speakers Voice Clarity INITIATING AND SUPERVISORY DEVICE TESTS AND INSPECTIONS *NOTE: ONLY DEVICES THAT HAVE BEEN TESTED ARE INCLUDED HERE. LOCATION & S/N DEVICE TYPE VISUAL CHECK FUNCTIONAL TEST FACTORY SETTING MEASURED SETTING PASS FAIL Auto Body Shop Manual Pull Station X P Carpenter Shop Heat Detector X P Carpenter Shop Heat Detector X P Carpenter Shop Manual Pull Station X P Commons Exit Manual Pull Station X P Custodal, by Electronics Heat Detector X P Drafting Closet Heat Detector X P Fire Brigade Heat Detector X P Fire Brigade Manual Pull Station X P Electronics Shop Heat Detector X P Exit by Electronics Shop Manual Pull Station X P Exit by Boiler Room Manual Pull Station X P Boiler Room Heat Detector X P Boiler Room Heat Detector X P (NFPA Inspection and Testing, 3 of 6)

LOCATION & S/N DEVICE TYPE VISUAL CHECK FUNCTIONAL TEST FACTORY SETTING MEASURED SETTING PASS FAIL Exit by Office Manual Pull Station X P Machine Shop Heat Detector X P Comments: All Initiating Devices worked Properly. * = Manually set the Pass state (NFPA Inspection and Testing, 4 of 6)

AUDIO VISUAL FAILURES DEVICE LIST LOCATION & S/N DEVICE TYPE PASS FAIL Comments: All Horn/Strobes Worked Properly. (NFPA Inspection and Testing, 5 of 6)

EMERGENCY COMMUNICATION EQUIPMENT VISUAL FUNCTIONAL COMMENTS Phone Set Phone Jacks Off-Hook Indicator Amplifier(s) Tone Generator(s) Call-in Signal System Performance INTERFACE EQUIPMENT VISUAL DEVICE OPERATION SIMULATED OPERATION (Specify) (Specify) (Specify) SPECIAL HAZARD SYSTEMS (Specify) (Specify) (Specify) Special Procedures: None Comments: None SUPERVISING STATIONMONITORING YES NO TIME COMMENTS Alarm Signal System Not Monitored Alarm Restoration Supervisory Signal Supervisory Restoration Trouble Signal Trouble Restoral NOTIFICATIONS THAT TESTING IS COMPLETE YES NO WHO TIME Monitoring Agency None Building Occupants þ All Building Management þ Donald Frasier Other (Specify) The following did not operate correctly: The System Tested Good With No Deficiencies. System restored to normal operation: Date: 08-04-15 Time: 8:00 THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS. Name of Inspector: Martin Hinkle Date: 08-04-15 Time: 8:00 Signature: Name of Owner or Representative: Donald Frasier Date: 08-04-15 Time: 8:00 Signature: (NFPA Inspection and Testing, 6 of 6)