Energy Companies Obligation (ECO): Boiler Assessment Checklist



Similar documents
Energy Company Obligation (ECO2) Boiler Assessment Checklist

A boiler breakdown can really be costly

service breakdown emergency 3in1 Plan What the SGS Service Plan provides What happens if you have a breakdown Cover provided by the Plan Dear

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

GUIDANCE NOTES FOR SUBMISSIONS TO UK GOVERNMENT S PRODUCT CHARACTERISTICS DATABASE

Comments and Ratings Almondvale Plumbing & Heating Services 12 Stevenson Court, Livingston, West Lothian, EH54 5NW

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Boiler efficiency for community heating in SAP

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

For installation guide see reverse of book

Repair, Modify or Replace?? What is the right answer?? By : Joe Mozeika

BIOMASS BOILER. Servicing and Maintenance Years. No Renewable Products Installed, Maintained

Gas Emergencies. You re in safe hands. Main title

Cowley Resident Management Organisation Ltd Cowley House, 147 Brixton Road London SW9 6LZ

Welcome to a warmer home. You could qualify for: Your guide to a gas supply and central heating system

HomeServices Terms and Conditions

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Scotland 10,000 homes connected

Boiler brands you can trust

Please find enclosed with our compliments, a memory stick with the following information on for your reference 1 :

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

Combi Eco Elite Range. User s Guide and Important Warranty Information

Housing Solutions Limited. Terms and Conditions. Fixmy Boiler Service

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

Factory owners must ensure the boiler is:

Energy Efficient Homes Package

Giving us a meter reading when we begin supplying you is important. This reading lets us bill you accurately from the start.

AGENCY AGREEMENT. Between 3Keys Limited company registration number of Town End Doncaster DN5 9AG Postcode..

GREEN EFFICIENT FRIENDLY SUSTAINABLE ENERGY: CERTIFICATED TRAINING

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

PART 11: START-UP PROCEDURES FOR THE INSTALLER

/2010 US/CA

Combi 24 HE. User s Guide and Important Warranty Information

The client organisation that was best at meeting residents needs in the provision of a maintenance service

Support for small businesses from Energy Saving Scotland advice centre

YOUR ENERGY IS OUR BUSINESS ELECTRICAL. Tel Freephone

APPLICATION FOR FINANCIAL ASSISTANCE

Contracts, agreements and tendering

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

A guide to landlords duties: Gas Safety (Installation and Use) Regulations What type of property is covered?

1.0 Purpose Definitions Hot Work Operations. 5

Preventative Maintenance & Statutory Testing

Energy Performance Certificates (EPCs) and renting homes: A landlord s guide

Combi 30 HE. User s Guide and Important Warranty Information

User Guide. Promax System Condensing System Boiler

Building Service & Maintenance

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Daikin Altherma Hybrid Heat Pump

Plumbing, Heating & Gas Industry Course Information

Metering and Monitoring Service Packages Technical Supplement

Daikin Altherma Hybrid Heat Pump

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

High Efficiency Heating

GREENSTAR HEATSLAVE 12/18, 18/25, 25/32

Daikin Altherma Hybrid Heat Pump

Operating instructions

Flame Conductivity VS Flame Rectification Systems

Utility Warehouse. Feed-In Tariff scheme. Application form

Boiler and Burner Cleaning and Servicing Specifications

Look after your boiler so it can look after you

CPM. Application Form INSURANCE FOR CYBER, PRIVACY & MEDIA RISKS

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

LABELLING OF GAS BOILERS - AN EFFICIENT MARKET REGULATOR

Operating instructions

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

WARRANTY BOOKLET. Continuous Flow Water Heaters. Register online at

EDf EnErGY trust. APPLiCAtion for financial ASSiStAnCE WHO CAN APPLY FOR A GRANT? HOW CAN THE TRUST HELP?

Feasibility Study Proposal & Report Guide. Industrial Optimization Program

ADVICE NOTE GAS BOILERS AND FLUE SAFETY. Important safety information about concealed gas boiler flues

Sample Company SECTION GENERAL COMMISSIONING REQUIREMENTS PART 1 GENERAL 1.1 SUMMARY AND CONTRACT RESPONSIBILITIES

User Guide. Main Heat Condensing Central Heating Boiler

SL280UHV SERIES GAS FURNACE WARNING

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Troubleshoot resources for homeowner

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Continuous Flow Water Heaters

Transcription:

Energy Companies Obligation (ECO): Assessment Checklist This Assessment Checklist (the Checklist) is designed to assist operatives 1 in assessing boilers under the Energy Companies Obligation (ECO) to determine whether a boiler should be repaired or replaced under that scheme. This document is intended to be a tool to assist you and does not provide any detailed information on the requirements of ECO. Further information on ECO can be found in our guidance document, Energy Companies Obligation (ECO): Guidance for Suppliers 2 or by contacting us at eco@ofgem.gov.uk. Completing the Checklist The information provided in the checklists will form the basis of our determination of whether the boiler is broken down or not functioning efficiently for the purposes of ECO. In completing the checklist you should ensure that you (i.e. the relevant operative): - Complete all relevant sections; - Sign and date the Checklist; - Record all the steps you have taken in determining boiler condition; and - Record your recommendation as to whether the boiler should be repaired or replaced. The Checklist should be retained by the relevant supplier for subsequent audits by Ofgem. Format of the Checklist Suppliers may adapt the format of the checklist to match their own systems, as long as the content is not changed. Suppliers may submit adapted checklists to us before use for confirmation that the content is acceptable. Accuracy of the Checklist It is important to note that your decision to replace a boiler on the basis that you consider the boiler is broken down/not functioning efficiently and cannot be economically repaired does not necessarily mean that we will reach the same conclusion, particularly if we consider that an assessment has been incorrectly carried out. For this reason, suppliers should ensure that the Checklist is completed accurately. Monitoring and Audit Monitoring and auditing will be undertaken to ensure that boiler assessments are carried out in accordance with our requirements. To effectively protect against fraudulent activity, auditing will include inspection of boilers before they are repaired or replaced. 1 The assessment and the repair or replacement of a qualifying boiler must be carried out by a person of appropriate skill and experience (the operative(s) ). See the ECO Guidance for Suppliers for details of operative competency requirements. 2 Available at : http://www.ofgem.gov.uk/sustainability/environment/eco/guidance/documents1/energy%20companies%20obligation%20 (ECO)%20Guidance%20for%20Suppliers%20-%2015%20March.pdf

Energy Companies Obligation (ECO) Assessment Checklist V1, published April 2013 Information Required Date of boiler assessment To be filled in by Operative on site Date of repair/ replacement Address Postcode Existing boiler details From boiler label/nameplate and fuel supply, determine the SAP Identifier information (fields 1-5 below) 1. Manufacturer 2. Brand 3. Model 4. Model Qualifier (if applicable) 5. Fuel Type Year of original commissioning (if available) Age of boiler (approx, if commissioning year unavailable) State how you have established year of original commissioning / age (e.g. servicing sticker, records held by householder, landlord records, original installation documentation, SEDBUK, SAP etc.) Is it a combination boiler? Yes No Seasonal Efficiency Rating: Provide efficiency rating when assessed against SAP/SEDBUK 2009 3 Assessment Part 1: Complete for all boiler repairs and replacements Is the boiler connected to a functioning domestic central heating (and, if applicable, hot water) system? Yes No Fault List (Note: this list is not exhaustive) repair possible replacement necessary 4 Supporting notes Example: heat exchanger corrosion or fouling heat exchanger replaced a. heat exchanger corrosion or fouling 3 See www.boilers.org.uk and search using above SAP Identifier information fields 1 5. If an efficiency rating is unavailable refer to SAP2009 Table 4a or 4b at: www.bre.co.uk/sap2009 4 Only tick this field if the fault cannot be repaired. 1

Fault List (Note: this list is not exhaustive) repair possible replacement necessary Supporting notes b. No boiler ignition or unstable firing c. Flue Gas Analyser combustion results outside boiler manufacturer tolerance d. Gas supply rate outside boiler manufacturer tolerance e. Gas supply pressure outside boiler manufacturer tolerance f. Burner pressure outside boiler manufacturer tolerance g. and system sludge h. Poor flue condition i. Primary flow rate outside boiler manufacturer tolerance or unsatisfactory j. Primary flow temperature outside boiler manufacturer tolerance or unsatisfactory k. For combination boilers only: Unsatisfactory hot water flow rate or temperature l. external corrosion m. installation is Immediately Dangerous (ID) or At Risk (AR) situations (Gas Safe definition) n. not installed in accordance with manufacturer s instructions and applicable regulations o. Other If other please provide detailed description Diagnosis/conclusion: is the boiler broken down? Yes No If no, have the faults identified above significantly affected the performance of the boiler so that it is not functioning efficiently? Yes No What steps did you take to reach this diagnosis/conclusion? 2

Assessment Part 2: Complete where boiler has a SAP/SEDBUK (2009) efficiency rating of 86% or above Are all parts required for the repair available? Yes No No parts required Is the actual cost of repair more than the actual cost of a replacement boiler? What is the actual cost of repair? 5 (If no proceed to Recommendation section) Yes No (If yes proceed to Recommendation section) What is the actual cost of a replacement boiler? 6 What is the condition of the existing boiler (when assessed against the expected condition Poor Standard Good of a boiler of that age)? 7 Is the actual cost of repair less than the maximum cost of repair as identified in the 'Economic Repair Cost Comparison Tables'? What is the maximum cost of repair as identified in the 'Economic Repair Cost Comparison Tables' 8 Repair or Replace? If repaired, provide details for repair undertaken (parts, etc.) Yes No type not in tables Recommendation (If boiler type not in tables proceed to Recommendation section) Repair Replace How much of the actual cost of repair is attributable to the cost of the warranty that has been/will be provided? If replaced, determine the SAP Identifier information for the new boiler, below: 1. Manufacturer 2. Brand 3. Model 4. Model Qualifier (if applicable) 5. Fuel Type Seasonal Efficiency Rating: Provide efficiency rating when assessed against SAP/SEDBUK 2009 9 5 See page 5 for costs to be included in actual boiler repair cost calculations. 6 See page 5 for costs to be included in actual boiler replacement cost calculations. 7 See page 6 for guidance on assessing boiler condition. 8 See page 5 for Economic Repair Cost Comparison Tables. 9 See footnote 1. 3

Start date of warranty Details of warranty 10 offered to customer: End date of warranty Is there a cap 11 on the value of repairs under the warranty? If yes, what is the cap? Yes No Has the customer been informed by you, the operative, that the boiler is under a warranty for: a) 1 year or b) 2 years from the date of repair (including an explanation of the nature of the warranty)? Yes, 1 year Yes, 2 years No For completion by the customer I, the customer, have been informed by you, the operative, that the boiler is under a warranty for: a) 1 year or b) 2 years from the date of repair. I have been provided with a copy of the warranty. I confirm that the nature of the warranty has been explained to me. Customer signature Operative & supplier details OPERATIVE 1 (Must meet industry competency standards and all legal requirements to work with the relevant fuel type) Operative company name Operative name Operative competency: Accreditation/Accrediting Body (e.g. Gas Safe) Accreditation Number This section MUST be completed by Operative 1 where a second operative has completed part of this checklist: I confirm that I have reviewed the information contained in this checklist and I am satisfied that it is reasonable. Additional comments Operative signature Yes No Operative company name OPERATIVE 2 (where applicable) Operative name Operative competency: Accreditation/Accrediting Body (if applicable) Accreditation Number (if applicable) Operative signature 10 Full details of the warranty requirements are available in Appendix 2 of the ECO Guidance for Suppliers (section 3.8). 11 See page 5 for details of the minimum cover which can be provided by the warranty. 4

Economic Repair Cost Comparison Tables 12 These tables provide guidance in determining when a gas boiler with a SAP/ SEDBUK (2009) efficiency of 86 percent or above cannot be economically repaired. They also show the minimum cap that may be applied to boiler warranties. There is a guide to using these tables overleaf, for reference. a. Maximum repair cost for combination boiler b. Maximum repair cost for regular boiler Condition of boiler Age of boiler Poor Standard Good 1 1,940 2,910 2,910 2 1,698 2,668 2,910 3 1,455 2,425 2,910 4 1,213 2,183 2,668 5 970 1,940 2,425 6 728 1,698 2,183 7 485 1,455 1,940 8 243 1,213 1,698 9-970 1,455 10-728 1,213 11-485 970 12-243 728 13 - - 485 14 - - 243 15 - - - Condition of boiler Age of boiler Poor Standard Good 1 1,107 1,660 1,660 2 968 1,522 1,660 3 830 1,383 1,660 4 692 1,245 1,522 5 553 1,107 1,383 6 415 968 1,245 7 277 830 1,107 8 138 692 968 9-553 830 10-415 692 11-277 553 12-138 415 13 - - 277 14 - - 138 15 - - - The actual cost of repair for each boiler should account for, where applicable: parts and fittings water treatment inhibitor central heating controls sub-contract electrician quotation re-connecting and commissioning labour warranty any works deemed necessary at time of repair to protect the boiler for the life of the warranty. The actual cost of a replacement boiler should account for all applicable items listed above plus the cost of the boiler and accessories, as appropriate. The warranty should at minimum provide cover for total repair works, during the life of the warranty, valued up to: the financial level indicated in the Economic Repair Cost Comparison Tables for a boiler of that type, age and condition; or 500 (exc. VAT), whichever is higher. 12 Note that all costs shown are exclusive of VAT 5

Using these tables Step 1: Determine the boiler condition, using the boiler fault details in the section of the completed Assessment Checklist entitled Assessment Part 1. Poor: Standard: Good: the apparent age of the boiler is a minimum of five years more than the actual age the apparent age of the boiler corresponds with the actual age the apparent age of the boiler is a minimum of three years less than the actual age (It should be noted that unless the boiler condition is demonstrably better or worse than expected for its age, the standard condition should be used.) Step 2: Use the boiler condition and the boiler age to identify the maximum cost of repair above which boilers with a SAP/SEDBUK (2009) efficiency of 86 per cent or above may be replaced. Example: type: Condition: Age: Regular Standard 4 years Age of boiler Condition of boiler Poor Standard Good 1 1,107 1,660 1,660 2 968 1,522 1,660 3 830 1,383 1,660 4 692 1,245 1,522 5 553 1,107 1,383 6 415 968 1,245 7 277 830 1,107 8 138 692 968 9-553 830 10-415 692 11-277 553 12-138 415 13 - - 277 14 - - 138 15 - - - Result: If boiler repair work costs over 1,245, this boiler can be replaced. If the boiler repair work costs less than 1,245, boiler repair can be carried out. In this case, the boiler warranty should cover the boiler for work up to at least the financial level of 1,245. 6