Aera FC-DR980 Digital Mass Flow Products



Similar documents
Aera Transformer Digital Mass Flow Products. Transform your process with greater flexibility and lower cost of ownership

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Mass Flow Meters & Controllers

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Thermal Mass Flow Meters and Controllers for Gases

Fundamentals of Mass Flow Control

Battery Powered Thermal Mass Flow Meters for Gases

Model 111 Mass Flow Instruments

VSO MAX HP High Flow Proportional Valve

Battery Powered Digital Mass Flow Meters for Gases

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Battery Powered Thermal Mass Flow Meters for Gases

TELEDYNE HASTINGS INSTRUMENTS

OEM-EP Pressure Controllers

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Typical Aluminum GFM Mass Flow Meter

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

API Marine. BMS Presentation. Ballast Measurement Systems

PRODUCT REVIEW. Flowmeters and Controllers. Vacuum Instrumentation

RM7000 TC with Internal Pulser

In semiconductor applications, the required mass flows

Gas Mass Flow Control Products

Compact, High-Flow Gas Regulators

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Airflow Sensors Line Guide

Micro Motion 3098 Gas Specific Gravity Meter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

COMBIMASS. Technical Data COMBIMASS eco-bio +

SEMICONDUCTOR TECHNICAL DATA

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Indoor / Outdoor Antenna

PRODUCT PROFILE FEATURES

Rosemount 333 HART Tri-Loop

Product Datasheet P MHz RF Powerharvester Receiver

Thermal Mass Flow Meter (Series MST)

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Rosemount 333 HART Tri-Loop

Models SFP33 & SFP32 Pressure Transmitters

Centro-Matic Automatic Lubrication Systems System Controls

Car and commercial cial air conditioning service solutions

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Incubator with mechanical convection

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Model: DC-A2IO Advanced HVAC Controller

Series 6000 Torque measured metal bellow coupling

DVT913 TV CHANNEL CONVERTER

PART 1 - INTRODUCTION...

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Rackmount Intelligent Pressure Scanners

Instruction Manual. T3111 T3111L T3111P T3111Ex

Ron 3025 Crane Scale with 1"/25mm Display

Precision Mass Flow Meters / Controllers for Liquids and Gases

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Temperature & Humidity SMS Alert Controller

Low Frequency Velocity Sensor

DVI to Analog Converter

Thermal Flow Sensor Die

psens Pressure Measurement

Duct Humidity Transmitter

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Data Sheet PS1B Pressure Switch

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

TC-9102 Series Surface Mount Temperature Controllers

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

Mini USB and USB 2.0-IP67 Connector System

For Multi-Parameter Meters see mvx

Micro Motion Model D and DL Coriolis Flow and Density Meters

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Basler beat AREA SCAN CAMERAS. High-resolution 12 MP cameras with global shutter

Multi-Range Programmable DC Power Supplies 9115 Series

Freescale Semiconductor. Integrated Silicon Pressure Sensor. On-Chip Signal Conditioned, Temperature Compensated and Calibrated MPX4080D.

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

Residual Gas Analyzers

Laminar Flow Elements

OPTIMASS 1400 Technical Datasheet

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

USB Flash Drive. RoHS Compliant. AH322 Specifications. July 2 nd, Version 1.2. Apacer Technology Inc.

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

T a b l e o f C o n t e n t s

Open channel & partially filled pipe Ultrasonic flow meters

4 Posiflow Proportional Solenoid Valves

automatic Changeover regulators and systems manifolds/changeover regulators

Electromagnetic Flow Meter

O C M III. Open Channel Flow Monitor

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Transcription:

Catalog Aera FC- Digital Mass Flow Products Leading digital MFCs and MFMs, providing superior versatility in various system

Benefits Superior accuracy, repeatability, and stability Significant cost savings Superior operational versatility Superior reliability Features Multi-gas,multi-range selection* Analog, analog/digital, and digital modes Piezoelectric control valves Multiple alarm and diagnostic capabilities Metal seals, with a 1x10-10 leak integrity Electropolished and ultra-cleaned gas-wetted surfaces * Available in multi-gas, multi- range models Multiple output options enable analog or digital control, for use with most existing control and communication configurations. To suit your priorities for value and functionality, this product line features both single-gas and multi-gas, multi-range MFCs. Multi-gas, multi-range features lower costs by dramatically reducing spare inventory requirements. For comprehensive monitoring and control capabilities, RS-485 communications (RS-232 with converter), combined with a full range of diagnostic and alarm functions, put operational parameters at your fingertips. Superior Accuracy, Repeatability, and Stability Algorithms unique to Aera MFCs provide very fast response between the sensor and control valve. The result is better flow accuracy, repeatability, and stability, with an actual-flow settling time of 1 sec. Significant Cost Savings Aera FC- series digital MFCs (mass flow controllers) and MFMs (mass flow meters) deliver performance excellence and operational versatility, resulting in significant cost savings and ease of use. Multi-gas, multi-range FC - MFCs reduce overall costs by minimizing spare MFC inventory requirements. Just eight units can replace hundreds of spares and part numbers. Single-gas MFCs require backup inventory for each process gas. Multi-gas, multi-range FC- MFC models dramatically reduce such requirements because they can replace any other MFC used in the process within the device s mechanical limits, regardless of gas type. Superior Operational Versatility Multi-Gas, Multi-Range Selection Multi-gas, multi-range Aera FC- series MFCs are easily field-programmable to run various gas, for any range within the MFC s mechanical limits. For quick gas and full-scale reassignment, they store calibration curves for up to four gases and ten calibration points for each gas. Multi-Mode Operation Choose from analog, analog/digital, and digital modes for operation with any control system. Error as % of Full-Scale Gas Flow 50 45 40 35 30 25 20 15 10 5 Digital Analog FC- digital MFCs provide superior accuracy compared to analog models. 0 2 5 10 20 30 40 50 60 70 80 90 100 Set Point as % of Full-Scale Gas Flow Figure 1. Digital vs. analog accuracy

SUPERIOR RELIABILITY High-quality electronic components and a robust design stand up to the effects of harsh operational demands, delivering superior, long-term, zero-drift stability less than 0.5% of full-scale flow over one year. Further, less than 0.5% of units are returned within a year of shipment. Specifications Operational FC-/C Series FC-DR981/DR981C Series Multi Gas Model (1) 10 30 sccm Multi Gas Model (2) 31 100 sccm Multi Gas Model (7) 5,001 10,000 sccm Full-Scale Ranges Multi Gas Model (3) 101 300 sccm Multi Gas Model (4) 301 1,000 sccm Multi Gas Model (5) 1,001 3,000 sccm Multi Gas Model (8) 10,001 30,000 sccm Multi Gas Model (6) 3,001 5,000 sccm Response Time Accuracy Repeatability Leak Integrity Control Range 1.0 sec typical per SEMI E17-91 (all control range) ±1% of set point from 25 to 100% of full scale ± 0.25% of full scale from 2 to 25% of full scale ± 0.15% of full scale 1x10-10 atm-cc/sec (He) maximum, 1x10-11 Pa m -3 /sec (He) maximum 2 to 100% of full scale Differential Pressure Max Operating Pressure Proof Pressure Temperature 7 to 40 psid 70 psig 145 psig 15 50 C (59 122 F) 22 to 40 psid: Multi Gas (7) 30 to 40 psid: Multi Gas (8) Alarm/Diagnostic Functions Flow, valve voltage, EEPROM error, zero adjustment error, communications error, and microprocessor error Normally Closed Valve Operational FC-/C Series FC-DR981/DR981C Series Full-Scale Ranges Single Gas Model 10 5,000 sccm Single Gas Model 6 50slm Response Time Accuracy Repeatability Leak Integrity Control Range 1.0 sec typical per SEMI E17-91 (all control range) ±1% of set opint from 25 to 100% of full scale ±0.25% of of full scale from 2 to 25% of full scale ±0.15% of full scale 1 10-10 atm-cc/sec (He) maximum, 1x10-11 Pa m -3 /sec (He) maximum 2 to 100% of full scale Differential Pressure Max Operating Pressure Proof Pressure Temperature 7 to 40 psid 70 psig 145 psig 15 50 C (59 122 F) 10 to 40 psid (5slm to 20slm nitrogen equivalent 22 to 40 psid (20slm to 30slm nitrogen equivalent 30 to 40 psid (30slm to 50slm nitrogen equivalent Alarm/Diagnostic Functions Flow, valve voltage, EEPROM error, zero adjustment error, communications error, and microprocessor error Normally Closed Valve Alarm/Diagnostic Functions

Specifications Physical FC-/C Series 1 FC-DR981/DR981C Series Control Valve Type Materials Standard Fittings Surface Finish Attitude Sensitivity Weight Normally-open or normally-closed piezoelectric Stainless steel, type 316L, 316, PCTFE 1/4 VCR, 1.5" width IGS, 1.125" width IGS (C-seal or W-seal) Electropolished and ultra-cleaned to 5 Ra May be mounted in any position 1.2 kg (2.2 lb) 1 Normally Closed Valve Electrical FC-/C Series 1 FC-DR981/DR981C Series Input Power Power Consumption In & Output Signal Digital/Service Port 1 Normally Closed Valve +15 VDC ±2% at 100 ma 15 VDC ±2% at 40 ma 2.1 W max Digital Mode: 0 to 100% Analog Mode: 0 to 5 VDC EIA standard, RS-485, two-wire, half-duplex, multi-drop with two RJ-11 connectors Model and Suffix Codes FC- FC-DR981 Series MFC Category Description Codes Product Type Mass flow controller (digital) FC-D RoHS Compliance Compliant with RoHS directives R Full-Scale Flow Range 10 sccm to 5 slm 6 to 50 slm 980 985 981 986 Control Valve Type Connector Normally-open piezoelectric Normally-closed piezoelectric C Top mounted connector T Side mounted pigtail connector Y 1/4" VCR compatible 4V 1.125" c-seal BA Fittings 1.125" w-seal BW 1.5" c-seal BM 1.5" w-seal BF Gas Full-Scale Flow Range (sccm or slm) Customer specified Gas N 2 Customer specified Full Scale 200 Single-Gas Example FC-D R 980 C 4V N 2 200 (MFC, RoHS compliant, normally-closed valve, ¼" VCR fittings, N 2 gas, 200 sccm full-scale range) Multi-Gas/Multi-Range MGMR (Please review full scale range indicated in previous page for Multi 1 8) Multi 1 8 (10 sccm 30 slm N2 Equivalent) Multi-Gas Example FC-D R 980 C 4V Multi 3 (MFC, RoHS compliant, normally-closed valve, ¼" VCR fittings, N 2 gas, 101 300 sccm full-scale range) 1 "T" and "Y" options are only for 985 and 986 compact MFC series

Electrical Connections FC-DR98x (D-sub 9pin) 1 VALVE OPEN /CLOSE 2 OUTPUT 0~5VDC 3 +15VDC 4 COMMON 5-15VDC 6 CONTROL 0~5VDC 7 COMMON 8 COMMON 9 VALVE TEST PT.(0~4VDC)

Dimensions 1.5 IGS Model 1.125 IGS Model T Model Y Model T Model BF BM DR981 DR981 mm Port-to-Port P L h H 127.4 135.4 25.4 127.0 135.0 Y Model 1/4 VCR Equivalent Fitting Model mm H FC-(C) 127.0 FC-DR981(C) 135.0 BW BA mm Port-to-Port P L H 127.4 DR981 135.4 127.0 DR981 135.0 http://www.hitachi-metals.co.jp Headquarters SEAVANS North Bldg., 2-1, Shibaura 1-chome, Minato-ku, Tokyo 105-8614, Japan Tel +81-3-5765-4000 Fax +81-3-5765-8311 Piping Components Company Fine Flow Division 2971-8 Ishikawa-cho,Hachioji-shi, Tokyo 192-0032, Japan Tel +81-42-645-8753 Fax +81-42-660-0320 San Jose Office 1920 Zanker Road,San Jose, California 95112, U.S.A. Tel +1-408-467-8900 Fax +1-408-467-8901 E-mail : aerasales-usa@hitmet.com Immermannstrasse 14-16,40210 Duesseldorf, Germany Tel +49-211-16009-0 Fax +49-211-16009-29 E-mail : aerasales-europe@hitachi-metals-europe.com Safety Precaution Before using any of the products introduced in this catalog, please read the respective user manuals thoroughly. Contents of this catalog is as of January 2012. The products and their specifications are subject to change without notice. Please check the latest catalog, technical documents or specifications before your final design, procurement or use of the products. Aera is a trademark of Hitachi Metals Ltd. VCR is a trademark of Swagelok Company Corporation. Troubles or damages caused by natural disaster or inevitable accident, caused by mishandling, use or storage in an improper place, use out of the rated specifications and modification, factors contamination and clog due to use of corrosive gas and reactive gas. Any trouble or damage that is outside of Hitachi Metals Ltd. s control has no responsibility (if it does not clarify where responsibility lies, warranty is to be determined whether or not it costs regardless of the warranty period after deliberation.) The addresses and contact points listed in this catalog are as of January 2012. Because changes may occur, if the telephone or fax number you are trying to reach is not in service, please contact us at the following. Hitachi Metals, Ltd. (Corporate Communications Office) Tel +81-3-5765-4076 Fax +81-3-5765-8312 E-mail : hmcc@hitachi-metals.co.jp Catalog No. HL-K275 Printed in January 2012 (T-HT 3)