Operating Instructions Electronics module VEGADIF 65



Similar documents
Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Safety instructions VEGADIS DIS81.CEIA/V****

PLICSMOBILE: Measurement data via the mobile network

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Operating Instructions VEGAFLEX C, PFA insulated

Operating Instructions VEGABAR 66. Submersible pressure transmitter with CERTEC measuring cell. Foundation Fieldbus - climate compensated

Operating Instructions VEGAFLEX 81. TDR sensor for continuous level and interface measurement of liquids. Modbus and Levelmaster protocol Coax probe

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

ATS Overhead Table Shelf System INSTRUCTION MANUAL

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

BroadBand PowerShield. User Manual

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Safety instructions VEGAPULS PSWL61. KX***H***

Bubble King. User Manual

Accessories SUNNY REMOTE CONTROL

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

HP UPS R1500 Generation 3

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Addendum to the Operating Instructions

Software and Display instruments

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

MultiDim MKII V.2 ORDERCODE 50386

Getting started with

Network Bullet Camera. Quick Operation Guide KNC-p3BR28V12IR

MB-Accumulator Operator's Manual

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

GREISINGER electronic GmbH

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

ICMP HDD. Installation manual

Bedienungsanleitung Akku-Bohrschrauber Manual de Instrucciones Taladro atornillador a batería Manual de operação Aparafusadora com bateria

How To Install A Power Supply (Uplast) With A Battery Pack

Operating Instructions VEGAFLEX 65

Digital inductive conductivity transmitter

LUCCI AIRFUSION QUEST II CEILING FAN

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

User manual Rev 1.3 Contents

Operating Instructions VEGASWING 51 - transistor (PNP)

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Cable Tester Pro ORDERCODE D1909

PBX Series Quick Fit Connector Bimetallic Steam Traps

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

Druck PV 62x pneumatic/hydraulic pressure stations

Rousseau 10. User Guide

Load Limiter ULS-60 ULS-80 ULS-100 ULS-125. Table of Contents. Assembly Instructions Load Limiter ULS-60, -80, -100, -125

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

Instruction Manual Differential Pressure Transmitter

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

SunMaxx Solar Filling Station Operating Instructions

=============================== WARNING

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Operating instructions in the back. PD1020L

Operating Instructions

SP-1700 OWNERS MANUAL

Remote Alarm Monitoring System

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

INFRARED QUARTZ WALL HEATER

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Server Rack Commissioning

804 Ti Stand. Manual EN

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

R-NET MOUSE MODULE TECHNICAL MANUAL SK

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Perle Protocol Transparent Media Converter Modules

How To Set Up An Inverter

CELO5. User & Installation Manual.

US Installation Manual Smappee Monitor

HP SATA/SAS hard drive and Solid State Drive installation

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

NFC Communication Tray Model: HHX-IT3-Z

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

Infrarot-Bewegungsmelder IP44

Tyan Computer. Transport PX22. Service Engineer s Manual

aseries A13B Mini Bullet Camera User Manual

MOUNTING AND OPERATING INSTRUCTIONS

Owner s Manual & Safety Instructions

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

Adjustment functions for both span and shift have been incorporated

VENTIsupport Version 1

User Manual THR840DUK Digital Thermostat

Beckhoff onboard SATA-RAID

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Sunny Boy Accessories SMA POWER BALANCER

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Installation and Operating Instructions (for chargers shown below)

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

Operating instructions. SCORP 220 Plus SCORP 360. Pipe Cutter. Code Machine-no.:

Master Anamorphic Lens 100/T1.9 Lens Flare Set. Date: May 2015

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

Transcription:

Operating Instructions Electronics module VEGADIF 65 Document ID: 36132 Differential pressure

Contents Contents 1 About this document 1.1 Function.................................. 3 1.2 Target group.............................. 3 1.3 Symbolism used............................ 3 2 For your safety 2.1 Authorised personnel........................ 4 2.2 Appropriate use............................ 4 2.3 Safety instructions for Ex areas................. 4 2.4 Environmental instructions..................... 4 3 Product description 3.1 Configuration.............................. 5 3.2 Principle of operation........................ 5 3.3 Packaging, transport and storage............... 5 4 Mounting 4.1 General instructions......................... 6 4.2 Mounting preparations....................... 6 4.3 Mounting steps............................. 6 5 Setup 5.1 Setup.................................... 9 6 Maintain 6.1 Instrument repair........................... 10 7 Dismounting 7.1 Dismounting steps.......................... 11 7.2 Disposal................................. 11 8 Supplement 8.1 Technical data............................. 12 2 Electronics module VEGADIF 65

1 About this document 1 About this document 1.1 Function This operating instructions manual has all the information you need for quick mounting and setup of a replacement module. Please read this manual before you start setup. 1.2 Target group This operating instructions manual is directed to trained qualified personnel. The contents of this manual should be made available to these personnel and put into practice by them. 1.3 Symbolism used Information, tip, note This symbol indicates helpful additional information. Caution: If this warning is ignored, faults or malfunctions can result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result. Ex applications This symbol indicates special instructions for Ex applications. l à List The dot set in front indicates a list with no implied sequence. Action This arrow indicates a single action. 1 Sequence Numbers set in front indicate successive steps in a procedure. Electronics module VEGADIF 65 3

2 For your safety 2 For your safety 2.1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the device the required personal protective equipment must always be worn. 2.2 Appropriate use Oscillator, emitting electronics, housing or process components are replacement components for existing sensors. 2.3 Safety instructions for Ex areas Please note the Ex-specific safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments. 2.4 Environmental instructions Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection. The environment management system is certified according to DIN EN ISO 14001. Please help us fulfil this obligation by observing the environmental instructions in this manual: l Chapter "Packaging, transport and storage" l Chapter "Disposal" 4 Electronics module VEGADIF 65

3 Product description 3 Product description 3.1 Configuration Scope of delivery The scope of delivery encompasses: l VEGADIF 65 electronics module l Documentation - this operating instructions manual 3.2 Principle of operation Application area The electronics module VEGADIF 65 is suitable for exchange in differential pressure transmitter VEGADIF 65. 3.3 Packaging, transport and storage Packaging Transport Transport inspection Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test according to DIN EN 24180. The packaging of standard instruments consists of environmentfriendly, recyclable cardboard. For special versions, PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies. Transport must be carried out under consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device. The delivery must be checked for completeness and possible transit damage immediately at receipt. Ascertained transit damage or concealed defects must be appropriately dealt with. Storage Up to the time of installation, the packages must be left closed and stored according to the orientation and storage markings on the outside. Unless otherwise indicated, the packages must be stored only under the following conditions: l Not in the open l Dry and dust free l Not exposed to corrosive media l Protected against solar radiation l Avoiding mechanical shock and vibration Storage and transport temperature l Storage and transport temperature see chapter "Supplement - Technical data - Ambient conditions" l Relative humidity 20 85 % Electronics module VEGADIF 65 5

4 Mounting 4 Mounting 4.1 General instructions Meas. cell and processing electronics The pressure transmitters VEGADIF 65 are equipped with a two-part electronics: the meas. cell and the processing electronics. The meas. cell electronics in the process fitting is not accessible to the user. The processing electronics, as an electronics module, is located in the housing. In case of a defect, the electronics module can be exchanged by the user. In Ex applications only one instrument and one electronics module with respective Ex approval may be used. Sensor serial number If no electronics module is available on site, it can be ordered from the VEGA agency serving you. The order is possible without or with sensor serial number. The serial number is stated on the type label of the instrument or on the delivery note. The electronics module without serial number contains no orderspecific data. However, operation of the instrument is also ensured without these data. This allows a "universal electronics module" to be kept in stock for several instruments. The electronics module with sensor serial number contains orderspecific data such as housing material, process fitting, meas. cell seal, etc. 4.2 Mounting preparations First of all, check by means of the order code if you are using the suitable electronics module: l Electronics module DF-E.60Z for all VEGADIF 65 4 20mA l Electronics module DF-E.60H for all VEGADIF 65 4 20mA/ HART l Electronics module DF-E.60P suitable for all VEGADIF 65 Profibus PA l Electronics module DF-E.60F suitable for all VEGADIF 65 Foundation Fieldbus. 4.3 Mounting steps Mounting steps The electronics module is located in the electronics compartment. The below illustrations show the respective position of the electronics compartment in a single or double chamber housing. 6 Electronics module VEGADIF 65

4 Mounting 1 Fig. 1: Single chamber 1 Position of the electronics compartment 1 Fig. 2: Double chamber housing 1 Position of the electronics compartment Proceed as follows: 1 Switch off power supply 2 Unscrew housing cover of the electronics compartment 3 Disconnect the connection cables according to the operating instructions manual of the respective sensor 4 Loosen the two holding screws with a screwdriver (Torx size T 10 or slot size 4) Electronics module VEGADIF 65 7

4 Mounting 1 2 Fig. 3: Loosening the holding screws 1 Electronics module 2 Screws (2 pcs.) 5 Pull the previous electronics out by holding the opening levers. Note: Make sure that the housing is not rotated during the electronics exchange. Otherwise the plug may be in a different position later. 6 Insert the new electronics module carefully. Make sure that the plug is in the correct position. 7 Insert the two hold screws and tighten them 8 Connect the connection cables according to the operating instructions manual of the respective sensor 9 Screw the housing cover on The electronics exchange is now finished. As a rule, the exchange of the electronics must be documented internally when used in Ex applications. 8 Electronics module VEGADIF 65

5 Setup 5 Setup 5.1 Setup Setup After mounting a new electronics module and connecting to power supply, the following data are loaded automatically from the meas. cell electronics: l Instrument type l Serial number l Date of manufacture l Measuring range l Default The instrument is generally ready for operation. If you are using an electronics module without sensor serial number or a "universal electronics module" from stock, you can load the orderspecific data of the sensor on site. Information: When loading on site, the corresponding file must first be downloaded from the Internet (see "Load sensor data"). Load sensor data Move via www.vega.com to the item "serial number search". The order data of the sensor will be displayed after entering the serial number. Below the order data you can find "Sensor data for Service DTM" as XML file. Load this file with "Save target under" onto your PC and then transfer the file via PACTware and the Service DTM to the sensor. Adjustment As a rule, settings already carried out on site with the previous electronics module such as min./max. adjustment etc., however must be repeated. Tip: Simply use the copy function of the adjustment module PLICSCOM or the adjustment software PACTware. Electronics module VEGADIF 65 9

6 Maintain 6 Maintain 6.1 Instrument repair If a repair is necessary, please proceed as follows: You can download a return form (23 KB) from our Internet homepage www.vega.com under: "Downloads - Forms and certificates - Repair form". By doing this you help us carry out the repair quickly and without having to call back for needed information. l Print and fill out one form per instrument l Clean the instrument and pack it damage-proof l Attach the completed form and, if need be, also a safety data sheet outside on the packaging l Please ask the agency serving you for the address of your return shipment. You can find the respective agency on our website www.vega.com under: "Company - VEGA worldwide" 10 Electronics module VEGADIF 65

7 Dismounting 7 Dismounting 7.1 Dismounting steps Take note of chapters "Mounting" and "Connecting to power supply" and carry out the listed steps in reverse order. 7.2 Disposal The replacement module consists of materials which can recycled by specialised recycling companies. We have purposely designed the electronic modules to be easily separable. WEEE directive 2002/96/EG This instrument is not subject to the WEEE directive 2002/96/EG and the respective national laws (in Germany, e. g. ElektroG). Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points. These may be used only for privately used products according to the WEEE directive. Correct disposal avoids negative effects to persons and environment and ensures recycling of useful raw materials. Materials: see chapter "Technical data" If you have no way to dispose of the replacement component properly, please contact us concerning return and disposal. Electronics module VEGADIF 65 11

8 Supplement 8 Supplement 8.1 Technical data Technical data can be found in the operating instructions manual of the respective sensor. 12 Electronics module VEGADIF 65

8 Supplement Electronics module VEGADIF 65 13

8 Supplement 14 Electronics module VEGADIF 65

8 Supplement Electronics module VEGADIF 65 15

Printing date: VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info@de.vega.com www.vega.com ISO 9001 All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. VEGA Grieshaber KG, Schiltach/Germany 2009 Subject to change without prior notice