Low Carbon Domestic Refurbishment

Similar documents
main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer

Strategic approach to the selection and procurement of construction materials and products

Energy Performance Certificate

Energy Use in Homes. A series of reports on domestic energy use in England. Fuel Consumption

Energy Performance Certificate

Energy Performance Certificate

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

Welcome to a warmer home. You could qualify for: Your guide to a gas supply and central heating system

Energy Performance Certificate

Energy Performance Certificate

FABRIC ENERGY EFFICIENCY FOR PART L 2013

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Rainwater Harvesting

Energy Performance Certificates (EPCs) and renting homes: A landlord s guide

Information for the Supply Chain on Green Deal Measures. Version 1

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Background material A United Kingdom Domestic Carbon Model (UKDCM) Description, method and analysis

GREEN DEAL Saving money by understanding the Energy Agenda. Dave Princep BSc LLB MCIEH

Green Deal, Energy Company Obligation and traditional buildings

Assessment Methods. 15 th November 2010 Huw Jenkins Simon Lannon

Appendix S : Reduced Data SAP for existing dwellings

Energy usage in households with Solar PV installations

Air-to-water heat pumps: Making the most of renewables. Richard Pickford, Daikin UK

BREEAM Refurbishment and Fit-out 2014 Briefings. Part of the BRE Trust

Information Guide Domestic Air Source Heat Pumps

English Housing Survey Headline Report

IES <Virtual Environment> Tutorial. Apache Sim (Version 6.0)

BER Assessors Dwellings Technical Bulletin

Domestic energy consumption in Barnet has reduced but remains higher than the British average:

SAP 2012 IN A NUTSHELL

Feed in Tariffs for Microgeneration. Jos Mister Energy Saving Trust

Appendix S: Reduced Data SAP for existing dwellings

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Bespoke ECO2 software for calculating savings: features for software development

Bridgend County Borough Council

Energy Efficient Windows

Your guide to the Energy Company Obligation (ECO) How we can make it work for you. A5_ECOguide_AW.indd 2 24/10/ :04

Grants for Renewable Energy and Sustainable Projects in Schools March 2010 Update

Sustainable Schools Renewable Energy Technologies. Andrew Lyle RD Energy Solutions

Recommendations for the cost-effective improvement of energy performance

HEED Online 2 Full Technical Guide (2.0)

Extra help where it is needed: a new Energy Company Obligation

ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE. Building Solutions Automotive Industry

Penwithick Green Deal Pilot project: Final report

The Energy Saving Trust s community solar programme How your community can benefit from discounted solar panels and Feed-in Tariffs

DEMScot 2: Scotland s Housing Carbon Model The extensions

Energy Company Obligation (ECO): Technical Monitoring Questions

Pilot Analysis of the Government's New Green Deal Initiative

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

A window of opportunity for hybrid heat pumps

BFRC ENERGY RATING THE REHAU ABC ENERGY EFFICIENT WINDOWS AND DOORS. Building Solutions Automotive Industry

Building Control Guidance Note

ZERO CARBON HOMES AND NEARLY ZERO ENERGY BUILDINGS. UK Building Regulations and EU Directives

The Enhanced Capital Allowance scheme for energy-saving technologies. A guide to equipment eligible for Enhanced Capital Allowances

Information Guide. The Application of Heat Pump Boilers. Issue Eighteen >

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME

MCS 021. HEAT EMITTER GUIDE FOR DOMESTIC HEAT PUMPS Issue 2.0

Case Studies of Successful Code for Sustainable Homes Projects

Warmer Healthier Homes: A Consultation Paper on a new Fuel Poverty Strategy for Northern Ireland

Solar for social housing

City Council Report for Information

Heat Pumps in the Building Sector: Hybrid Heat Pumps opening UK retrofit opportunities?

Part L1B & What you need to know to get your building to pass. Mike Andrews DipNDEA, DipDEC, DipOCDEA, DipHI

Domestic Green Deal and Energy Company Obligation in Great Britain, Monthly report

The Government s Standard Assessment Procedure for Energy Rating of Dwellings

tap into opportunities to develop your business

Code for Sustainable Homes Guidelines

Daikin Altherma Hybrid Heat Pump

Code for Sustainable Homes Technical Guide

Costing Energy Efficiency Improvements in Existing Commercial Buildings

Implementation of the EPBD in Cyprus. Status in November > Introduction. 2 > Certification. Cyprus

Report 3: Metered fuel consumption

Community Solar Roof Guide

Response to the Green Deal and Energy Company Obligation consultation

ECA272. The Enhanced Capital Allowance scheme for energy-saving technologies

Put us to the test. Construction testing and building investigations services from BRE.

Energy efficiency and excess winter deaths: Comparing the UK and Sweden

RDSAP Manual March 2012

Private Sector Landlords. Making your properties more energy efficient

npower - providing energy services for Social Housing

Proposal to achieve Code for Sustainable Homes Level 3 for a development of 7 detached dwellings

Orchestration of Renewable Integrated Generation in Neighbourhoods. Grant Agreement Number: D1.1 Audit Template

Hybrid heat pumps. saving energy and reducing carbon emissions

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

How To Boost Your Cash Flow With The Enhanced Capital Allowance Scheme

MIDDLESBROUGH HECA PROGRESS REPORT 2015

Your guide to heating your home

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

qwertyuiopasdfghjklzxcvbnmq ertyuiopasdfghjklzxcvbnmqwer tyuiopasdfghjklzxcvbnmqwerty uiopasdfghjklzxcvbnmqwertyui

SP Energy Networks Business Plan

Case Study: Low carbon refurbishment of Westborough Primary School

EPC and Licenses - UK

Improving the energy efficiency of our buildings

Guidance on how to comply with the 2010 Building Regulations Part L

Directorate for Sustainable Communities. Private Sector Housing Strategy

Module 3.7. Thermal bridging

The Enhanced Capital Allowance scheme for energy-saving technologies

Transcription:

www.breeam.com Briefing Paper Low Carbon Domestic Refurbishment Kiruthiga Balson, Gavin Summerson and Steven Stenlund

2 BRE Global Ltd 2014 Permission is granted for this report to be distributed only in its entirety, without amendment, and with copyright attribution to BRE Global Ltd. Every effort has been taken to ensure the accuracy of this report but no warranty is made in respect of any conclusions or opinions expressed herein. BRE Global Ltd s liability in respect of this report and any reliance thereupon is disclaimed and BRE Global shall have no liability to third parties to the extent permitted in law.

3 Introduction The majority of dwellings in the UK can be refurbished to achieve higher energy performance levels. However, there are a number of factors which will dictate the potential for refurbishment and corresponding Energy Efficiency Rating (EER) 1 as determined by the UK Government s Standard Assessment Procedure, SAP. Some of the determining factors are: the age of the dwelling, type and construction method the dwellings state of repair, and existing performance the project budget if the dwelling is listed or in a conservation area, and if the dwelling will be occupied during the refurbishment The research outlined in this paper was funded by the BRE Trust with the objective of understanding what improvements can be carried out in common dwelling types to improve the Energy Efficiency Rating (EER) and as a result achieve higher performance within environmental assessment schemes such as BREEAM Domestic Refurbishment (BDR). This research illustrates the importance of considering the existing energy performance of a dwelling (baseline EERs), how this influences the level of energy efficiency improvements that can be achieved and the resulting credits under the BREEAM Domestic Refurbishment scheme. It also highlights what measures may be required to improve a home, depending upon the existing performance of the dwelling, based upon age band and dwelling type. 1 The Energy Efficiency Rating measures the overall energy efficiency of a dwelling on an A to G scale, ranging from 1 to 100 (the higher the number, the higher the energy efficiency). The Energy Efficiency Rating is equivalent to the Government s Standard Assessment Procedure (SAP) Rating in Full SAP simulation.

4 Summary of findings The report shows that irrespective of the dwellings age and existing performance, there are a range of measures that can be adopted in order to achieve high BREEAM ratings. In terraced dwellings, there are opportunities to achieve the minimum BREEAM energy standards for Excellent and Outstanding without the need to install renewables. Also, all detached and semi-detached dwellings have the potential to achieve at least the minimum energy standard for a BREEAM Very Good level, where a reasonable whole house package of measures were adopted, equivalent to refurbishment package P4 as highlighted by figure 2 of this report. However, this investigation has also demonstrated the importance of reducing electricity demand in dwellings when aiming for higher BREEAM scores. Overview of BREEAM Domestic Refurbishment (BDR) The BREEAM Domestic Refurbishment (BDR) environmental assessment standard aims to encourage high but achievable levels of Energy Efficiency in refurbished dwellings, thus reducing CO 2 emissions, running costs and fuel poverty. When seeking BREEAM Domestic Refurbishment certification it is important to consider the level of intervention required to meet the desired target rating. The BREEAM energy category assesses measures to improve the energy efficiency of the home through refurbishment. 65% of the available energy score relates to targets based upon SAP or the EPC. It awards credits for predicted whole building performance levels based on the inherent properties of the dwelling rather than actual energy consumption which is influenced significantly by other factors including the behaviour of occupants. This briefing note focusses on the impact of refurbishment on the Ene 01 BREEAM credits (Improvement in Energy Efficiency Rating) and Ene 02 (Energy Efficiency Rating Post Refurbishment) credits, which have various benchmark performance levels as detailed below in table 1. BREEAM credits Ene 01 - Improvement in EER score Ene 02 - EER score post refurbishment 0.5 5 50 1.0 9 55 1.5 13 60 2.0 17 65 2.5 21 70 3.0 26 75 3.5 31 80 4.0 36 85 4.5 42-5.0 48-5.5 54-6.0 60-1 exemplary credit 2 exemplary credits - 90-100 Table 1: BREEAM Domestic Refurbishment Ene 01 and Ene 02 credits The Co-operative Group s Manchester headquarters

5 BREEAM assessment issue number Ene 01 (Improvement in Energy Efficiency Rating) awards up to 6 credits where the refurbishment results in an improvement in the dwellings Energy Efficiency Rating (EER) over that prior to refurbishment using the benchmark levels in Table 1. Where, as a result of refurbishment, the dwelling meets certain thresholds of minimum Energy Efficiency Rating up to 4 credits are awarded for BREEAM assessment issue Ene 02. One exemplary credit is also available where the dwelling achieves a post refurbishment EER greater than 90 with two credits available for a post refurbishment EER of equal to or greater than 100. Overall the method gives a balanced assessment with some credit given for how much the homes energy efficiency has been improved, whilst also giving credits where a minimum EER is achieved post refurbishment. This balance rewards homes that have a poor existing performance that are significantly improved as a result of refurbishment. It also rewards homes that may have a limited potential for improvement but a good existing performance. To achieve a particular BREEAM rating and gain certification a minimum EER rating is required along with a minimum overall BREEAM score (measured as a percentage of the total score available under the method across the full range of issues covered). The minimum overall percentage BREEAM score and EER standards are detailed below in Table 2. BREEAM rating Minimum EER rating required Overall % BREEAM score Pass 50 30 Good 58 45 Very Good 65 55 Excellent 70 70 Outstanding 81 85 Table 2: BREEAM Domestic Refurbishment Minimum EER standards and rating benchmarks Research Methodology Firstly a selection of notional dwelling types were modelled using the full version of SAP. Whilst not every house type was modelled, these represented the most common house types and age bands in the UK. They are based upon a BRE report for the DETR standard house types for modelling, developed in support of BREDEM (BRE s Domestic Energy Model). This included: Pre-1919 solid wall detached; 1950 s semi-detached; 1960 s bungalow; 1980 s detached; Pre-1919 end-terrace and mid terrace; Post 2002 mid-terrace; 1985 mid floor flat (electric); 1985 mid floor flat (gas); The researchers then tested the effect of a range of refurbishment improvements on the EER. For the purpose of this research, six different refurbishment packages (P1 to ) were developed ranging from simple to more comprehensive and complex actions. Refurbishment package P1 covers low cost, unobtrusive techniques such as simple insulation techniques, which are likely to offer a small improvement in overall performance. Package measures are high cost, advanced whole house refurbishment measures including the installation of renewables. 4 versions of package were developed in order to model the impact of each type of renewable technology that is likely to be suitable for existing dwellings. The intermediate packages, P3 and P4 include improvements in an increasing order of scale towards packages P5 and which are current best practice. Table 3 outlines the list of individual measures within each package 2. P1 50mm loose jacket to cylinder Roof insulation (0.16 W/m2K) P3 New cylinder Roof insulation (0.13 W/m2K) Cavity insulation (0.50 W/m2K) New boiler (SEDBUK2005-90%) New cylinder Roof insulation (0.13 W/m 2 K) Cavity insulation (0.50 W/m 2 K) New cylinder P4 Roof insulation (0.13 W/m 2 K) Cavity (0.50 W/m 2 K)/Solid wall insulation (0.30 W/m 2 K) New boiler (SEDBUK2005-90%) Floor insulation (timber 0.25 W/ m 2 K) 2 Not all measures within each package necessarily apply to all dwellings, either because the dwelling already possesses that measure, or it is not possible to install a measure.

6 New cylinder P5 Roof insulation (0.13 W/m2K) Cavity (0.50 W/m 2 K)/Solid wall insulation (0.30 W/m 2 K) New boiler (SEDBUK2005-91%) + advanced controls Floor insulation (timber/concrete 0.25 W/m 2 K) Double glazing (BFRC C) New cylinder Roof insulation (0.11) Cavity (0.50 W/m 2 K)/Solid wall insulation (0.30 W/m 2 K) New boiler (SEDBUK2005-91%) + advanced controls Floor insulation (timber/concrete 0.20 W/m 2 K) Double glazing (BFRC B) Solar renewables- Solar PV 2 kwp No secondary heating New cylinder Roof insulation (0.11) Cavity (0.50 W/m 2 K)/Solid wall insulation (0.30 W/m 2 K) New boiler SEDBUK2005 - (91%) + advanced controls Floor insulation (timber/concrete 0.20 W/m 2 K) Double glazing (BFRC B) Solar renewables- Solar Thermal 4m 2 OR Solar renewables- Solar PV 2 kwp No secondary heating (Air source heat pump) New cylinder Roof insulation (0.11) Cavity (0.50 W/m 2 K)/Solid wall insulation (0.30 W/m 2 K) Floor insulation (timber/concrete 0.20 W/m 2 K) Double glazing (BFRC B) Air source heat pump SAP default No secondary heating (Air source heat pump & PV) New cylinder Roof insulation (0.11) Cavity (0.50 W/m 2 K)/Solid wall insulation (0.30 W/m 2 K) Floor insulation (timber/concrete 0.20 W/m 2 K) Double glazing (BFRC B) Air source heat pump - SAP default & Solar renewables- Solar PV 2 kwp No secondary heating Table 3: Refurbishment packages Using the Standard Assessment Procedure (SAP) 2009 as the energy modelling methodology, the EERs of the selected dwelling types were calculated. The following sections of this report present the findings of this modelling for each dwelling type and corresponding scores achieved for Ene 01 and Ene 02 in the BREEAM Domestic Refurbishment (BDR) scheme.

7 Notional dwelling types: Before refurbishment typical EER Figure 1 shows the baseline EER modelled using SAP 2009. This was then used to highlight the improvements that could be made through the refurbishment packages. The SAP modelling takes into consideration cavity party wall heat losses for the 1950s semi-detached, 1960s bungalow, post 2002 mid-terrace and 1985 mid-floor flats. This cavity party wall heat loss is as a result of heat losses through thermal bypass within the cavity, rather than heat loss into the adjacent dwellings. This was not modelled for pre-1950 s housing since they do not have cavity party walls and therefore heat is instead lost into adjacent dwellings. When the research was conducted, there was no means to model the impact of applying party wall insulation however it should be noted that this measure is now being recognised under SAP. The period (pre-1919) detached dwelling had the lowest EER of 18, due to their poor thermal resistance, i.e. lack of any insulation (U-Values were as follows: 2.10 W/m 2 K for the external wall, 0.74 W/m 2 K for the ground floor and 2.30 W/m 2 K for the roof) and the high number of exposed surfaces. Whereas the post 2002 mid-terrace meets more exacting energy efficient targets for Building Regulations therefore an EER of 69 was calculated, the highest out of all the assessed dwellings. More recent homes such as 1960s or 80s dwellings had a comparatively higher baseline EER performance than period homes (see figure 1) thus limiting the opportunity for a further increase in the EER. The energy efficiency of the terraced dwellings varied with the age of the properties. There are large differences in EER ratings between the gas (66) and electric (43) mid-floor flats. This is due to the electric fuel heating source being more carbon-intensive and expensive. Figure 1 Notional dwelling types and typical Energy Efficiency Rating (EER) before refurbishment 80 EER Score (SAP 2009) 70 60 50 40 30 20 SAP Rating D (EER 55-68) SAP Rating E (EER 39-54) SAP Rating F (EER 21-38) SAP Rating G (EER 1-20) 10 0 Solid wall detached Period Semi-detached 1950s Bungalow 1960s Detached 1980s End-Terrace Period Mid-Terrace Period Mid-Terrace 2002 Mid Floor Flat (electric) 1985 Mid Floor Flat (gas) 1985

8 Post refurbishment performance A range of refurbishment measures (packages P1 to ) were applied to all dwelling types to model the potential energy performance improvements. The following sections of this report illustrate the results of this modelling for a selection of house types including how it affects overall energy performance, the resulting Ene 01 and Ene 02 credits and minimum energy standards achieved under BREEAM Improvements required to achieve minimum BREEAM energy standards Table 4 defines the package of measures that were required, in order to achieve each of the BREEAM minimum energy standards from Pass to Outstanding for each house type, as modelled in this research. For the minimum standards, the findings show that across nearly all house types modelled including detached, semi-detached and terraced homes, the minimum energy standard for a BREEAM Very Good rating can be achieved for a reasonable whole house package of measures, equivalent to package P4. The results also show that the minimum energy standards required for BREEAM Excellent can be achieved in all house types that were modelled without the need for renewables. The only exception was for the mid-floor electrically heated flat, which did not achieve the minimum required for a Very Good until package P5 was specified. In addition the measures required by package P4, this also requires BRFC C rated double glazing and advanced heating controls to be present. The mid-floor electric flat also required a minimum of package to achieve the minimum energy standard required for a BREEAM Excellent. This is as a result of the fuel source with electricity sourced from the grid being the most costly and carbon intensive fuel type, thus requiring a greater level of improvement in order to improve the EER and BREEAM minimum standards. Dwelling Type Period solid wall detached 1950s semi detached 1960 s bungalow 1980 s bungalow Period endterrace Period midterrace Post 2002 mid terrace 1985 Mid flat (electric) 1985 Mid flat (gas) Package of measures required Pass Good Very Good Excellent Outstanding P4 P4 P4 P4 P1 P4 P1 P4 P5 As existing (baseline) P3 P5 P3 P4 P4 As existing (baseline) As existing (baseline) P1 P4 P4 As existing (baseline) As existing (baseline) P3 P5 As existing (baseline) As existing (baseline) As existing (baseline) (PV + ASHP) (solar thermal) or Table 4: Packages of work required to achieve BREEAM standards by house type

9 Results detached and semi-detached dwellings Energy Efficiency Rating Figure 2 shows the EER ratings achieved for each package of measures from packages P1 to for the detached and semi-detached dwelling types. It is noticeable that the level of EER improvement achievable varies significantly with dwelling age and construction type. For the reasons described earlier, the period solid wall detached dwelling type achieved the highest improvement in EER score after refurbishment compared to other detached house types. The baseline EER score (18) almost doubled with simple fabric improvement measures in package 1 (P1). The improvement increased with higher refurbishment specifications involving improvements to both fabric and services. The package 4 (P4) increased the baseline EER score by approximately four times, and a further increase with renewables in. It is worth noting the level of EER improvement for P4 in other dwelling types was relatively low. Figure 2 Pre and post refurbishment EER for detached and semi dwelling types and corresponding BREEAM minimum energy standards 90 EER Score (SAP 2009) 80 70 60 50 40 30 48 42 50 56 53 50 35 66 63 58 40 69 69 79 68 68 69 62 49 72 72 71 78 77 74 85 85 83 81 Outstanding (EER = 81) Excellent (EER = 70) Very Good (EER = 65) Good (EER = 58) Pass (EER = 50) 20 10 18 0 Baseline EER P1 P3 P4 P5

10 BREEAM Ene 01: improvement in energy performance Figure 3 illustrates the number of Ene 01 credits awarded across the detached and semi-detached dwellings. Variation across the baseline EERs (i.e. the EER rating prior to refurbishment) determined the potential improvement in energy performance that can be achieved and the number of Ene 01 credits that may be achievable. The highest number of Ene 01 credits (6 out of 6) was achieved by the period solid wall detached dwelling for package as shown in figure 3. For the same package the semi-detached and 1960s bungalow achieved 4 out of 6 credits, and 3.5 credits for the 1980s detached dwelling. Packages P1 to P5 resulted in a higher number of credits in hard to treat dwellings, such as period properties, compared to newer build house types. For example, package P5 resulted in 5.5 credits in the period solid wall detached compared to 2.5 credits in the 1980s detached dwelling type. Period properties achieved the highest credits for Ene 01 overall, due to the lower baseline EER scores, therefore providing the greatest potential for improvement. The 1980s detached dwellings already have a good existing performance therefore the lowest potential for improvement. This limits the potential number of Ene 01 credits however benefits the number of Ene 02 credits highlighting the balanced approach the BREEAM methodology provides between absolute and relative performance. BREEAM Ene 02: energy performance post refurbishment Refurbishing the period solid wall detached dwelling using packages P1 to P3 did not result in any credits under Ene 02. This is because the baseline EER score was so low that it did not result in achieving the minimum EER score of 50 until package P4 was applied as shown in figure 3. Applying package P4 enabled this dwelling type to achieve 2 credits, thus meeting the minimum standards for energy required for a BREEAM Very Good rating. On the other hand, package P1 helped to improve the baseline EER for the semi-detached and 1960s bungalow dwelling types. This helped to meet the minimum criteria set for a BREEAM Pass rating. By progressing to higher refurbishment specification in packages to these two dwelling types advanced the EER score. Package was sufficient to bring the 1950 s semi-detached to Very Good minimum performance level. However, the 1960 s bungalow had to be upgraded to higher level of improvements using package P4 to reach the same performance level. Both dwelling types resulted in achieving the Excellent minimum performance level with P5. For the 1980s detached dwelling, pre-refurbishment the baseline EER (50) was high enough to meet the minimum energy criteria set for a BREEAM Pass rating, without any refurbishment work. Package promoted this dwelling to be eligible for BREEAM Good rating by increasing its EER score and gaining 1 credit for Ene 02. The maximum number available credits for Ene 02 were achieved by the semi-detached dwelling modelled for package. Similarly other dwelling types achieved their best performance and higher number of Ene 02 credits for package. Figure 3 Detached and semi dwellings post-refurbishment BREEAM ENE 01 & ENE 02 credits BREEAM Credits 6 5.5 5 4.5 4 3.5 3 2.5 2 1.5 1 0.5 0 P1 P3 P4 P5 ENE 01 ENE 02 P1 P3 P4 P5 Period solid wall detached Semi-Detached 1960s Bungalow 1980s Detached

11 Results - terraced dwellings Energy Efficiency Rating Three terraced dwelling types including period end-terrace, period midterrace and post 2002 mid- terrace were modelled using packages 1 to 6. Package P1 was assumed to be not applicable to the post 2002 midterrace as all of the measures should have been built into the dwelling in accordance with the Building Regulations applicable at that time. Period solid wall detached houses achieved the highest overall improvement in EER score after being refurbished under all packages, with the exception of package P1. As illustrated in figure 4, building fabric improvement measures in package P1 resulted in a minor improvement to the baseline EER score for both period end-terrace and mid-terrace dwellings, from 36 to 42 and 51 to 61 respectively. With an increasing level of refurbishment from packages to P5, the EER score gradually improved for the end-terrace dwelling, almost doubling its baseline score to 73 with package P5. Similarly, for the period mid-terrace dwelling, package P5 boosted the baseline performance by 1.5 times, resulting in a score of 76. Overall, the newest construction post 2002 mid-terrace dwelling type saw the lowest increase to the baseline EER for packages to P5. The highest specification with renewables (Solar) and resulted in maximum raise in performance across all dwelling types. Figure 4 Pre and post refurbishment EER for terraced dwelling types 100 EER 90 80 70 60 50 51 69 61 51 62 74 76 76 74 69 64 59 74 76 80 79 77 89 87 84 Outstanding (EER = 81) Excellent (EER = 70) Very Good (EER = 65) Good (EER = 58) Pass (EER = 50) 40 42 30 36 20 10 0 Baseline EER P1 P3 P4 P5 Period End-Terraced Period Mid-Terraced Post-2002 Mid-Terraced

12 BREEAM Ene 01 improving the energy efficiency rating Ene 01 rewards dwellings which improve the most on their baseline EER. None of the terraced dwelling types modelled in this research using Packages P1 to achieved the maximum number of credits (6 no) available for Ene 01. As demonstrated in figure 5, package enabled the period end-terrace dwelling to reach 5 out of the 6 available credits followed by the period mid-terrace (4 credits) and post 2002 mid-terrace houses (2 credits). For other packages, P3 and P4, the period end-terrace dwelling achieved 1.5, 2.5 and 3.5 credits respectively. However, the same packages resulted in lower number of credits for other dwelling types compared to end-terrace as shown in figure 5. The newest construction, post 2002 mid-terrace dwelling with the highest baseline EER prior to refurbishment, achieved the lowest number of credits (2 credits) under ENE 01. BREEAM Ene 02 energy efficiency rating post refurbishment For the period end-terrace dwelling package P1 measures were inadequate to improve the baseline EER to reach a BREEAM minimum energy standards required for a Pass rating i.e. reaching an EER of 50. This resulted in achieving 0 credits as shown in figure 5. Package helped this dwelling type to qualify for BREEAM Pass equivalent rating by achieving 0.5 credits. In packages P3 and P4, the EER improvement met the minimum standards BREEAM Good and Very Good respectively. Finally, as illustrated in figure 5, the package considerably increased the EER score. However, this was not adequate to gain the maximum number of credits under Ene 02 as only 3.5 credits out of 4 were achieved. The period mid-terrace notional dwelling s baseline EER (51) before refurbishment meets the minimum standard for BREEAM Pass rating without any improvements required. Figure 5 shows that applying package of measures P1, and P3 increased this baseline EER score resulting in 1.5 credits and met the minimum criteria for BREEAM Good rating. Packages P5 and (Solar thermal) resulted in 3 credits, equivalent to the BREEAM Excellent minimum energy standard level. Only through installing photovoltaics in package this dwelling type achieved the maximum number of credits available for Ene 02. In the post-2002 mid-terrace, the baseline EER (69) pre-refurbishment was high enough to meet the minimum criteria set for BREEAM Good rating. Package promoted this dwelling to be eligible for the minimum energy standard required for BREEAM Excellent rating by increasing its EER score gaining 2.5 credits. Overall, for this more modern dwelling, the impact on EER score from packages P1 to P5 was relatively small compared to other two dwelling types. Package 6 with renewables resulted in the highest increase in EER score and higher BREEAM credits with 3.5 credits with Solar thermal and 4 credits for PV. Figure 5 Terraced dwellings postrefurbishment BREEAM ENE 01 & ENE 02 credits BREEAM Credits 6 5.5 5 4.5 4 3.5 3 2.5 2 1.5 1 0.5 0 P1 P3 P4 P5 ENE 01 ENE 02 P1 P3 P4 P5 Period End-Terraced Period Mid-Terraced Post-2002 Mid-Terraced

13 Results: mid-floor flats Energy Efficiency Rating Figure 6 shows that the baseline EER for the 1985 mid-floor electric flat is lower than the gas heated mid-floor flat of the same year of construction. This is because of higher emission rates from electric heating. As a result, gas heated mid-floor dwellings performed better in each refurbishment package. (Air source heat pump) and (Air source heat pump and PV) was applied only in the electric heated flat. (Solar thermal) was modelled only in the gas heated flat. Package P1 did not improve the EER enough to reach the minimum performance standard for a BREEAM Pass. Packages, P3 and P4 achieved a very similar level of EER improvement across the board as shown in figure 6. PP5 increased the baseline EER score by approximately 1.5 times, and a further increase with renewables in. The highest EER improvement, which was double the baseline score, was achieved in (Air source heat pump and PV). Therefore, if feasible, installing an air source heat pump and PV in electric heated mid-floor dwelling would significantly improve the EER score by displacing electricity related emissions. This may, however, not be feasible due to limitations on installing PV and ASHP in a mid-floor flat, depending on access to an appropriate installation space. Figure 6 Pre and post-refurbishment EER for mid-floor dwelling types 100 90 91 94 80 70 60 66 69 60 74 76 76 60 60 66 78 81 78 81 EER 50 49 40 43 30 20 10 0 Baseline Performance P1 P3 P4 P5 (Airsource Heat Pump) 0 0 0 (Airsource Heat Pump & PV) 1985 Mid-Floor Flat (electric) 1985 Mid-Floor Flat (gas)

P1 P3 P4 P1 P3 P4 14 BREEAM Ene 01: improving the energy efficiency rating Figure 7 shows package P1 resulted in minor improvements to the baseline and the EER in both flats heated by electric and gas however only the gas heated flat achieved sufficient improvement to achieve any credits, with 0.5 credits achieved. Figure 7 shows that package improved the baseline EER for the electrically heated mid-floor flat from 43 to 60, resulting in 2 credits. Packages, P3, P4 and P5 resulted in higher EER improvements in the electrically heated flats and as a result a higher number of Ene 01 credits. On the other hand, the gas heated flats were unable to achieve 2 credits without installing renewables in package, with the EER improvement under packages to P5 not high enough. BREEAM Ene 02: energy efficiency rating post refurbishment Figure 7 illustrates that the electric heated mid floor flat can achieve the minimum energy standard for a BREEAM Excellent rating with fabric improvement and improved services in the dwelling. By additionally installing renewables, primarily to address electricity related emissions in, this resulted in achieving all 4 available credits for Ene 02. As mentioned before relates to installing air source heat pumps and PV to a mid-floor flat, which may not be feasible. Similarly, a gas heated 1980s mid floor flat can achieve 3 out of the 4 available credits through fabric and service related measures in P3 to P5. By installing PV this can be increased to 4 credits, the maximum number available, for Ene 02. Figure 7 Terraced dwellings postrefurbishment BREEAM ENE 01 & ENE 02 credits 6 5.5 5 4.5 4 BREEAM Credits 3.5 3 2.5 2 1.5 1 0.5 0 ENE 01 ENE 02 P5 (Airsource Heat Pump) (Airsource Heat Pump & PV) P5 (Airsource Heat Pump) (Airsource Heat Pump & PV) Period End-Terraced Period Mid-Terraced Post-2002 Mid-Terraced

15 Summary The results of this research show that older properties such as Pre-1919 terraced and detached homes typically have the highest potential for improvement and need to focus on fabric measures. For properties built to more modern standards such as post-2002 properties, there needs to be more of a focus on systems including renewables in order to achieve an improvement. In some cases, the impacts of packages P1 to P3 were so low that no credits were awarded, for example the pre-1919 solid wall terrace. However this reflects the limited improvement these packages may achieve for the worst performing properties. In hard to treat properties that consider whole house refurbishment and services beyond package P3, they will achieve higher EER improvement and better BREEAM scores, due to the low baseline and the level of improvement this level of refurbishment achieves. Overall, this results in the Ene 01 credits giving the greatest reward to improvements that are made to the worst performing homes. Newer dwellings have a higher baseline EER and are harder to improve and achieve credits in Ene 01. However, due to the higher baseline of newer dwellings, it is easier to achieve credits under Ene 02. Therefore it is important to consider renewables, and other measures that provide occupants with opportunities to reduce their energy use or their impact on transport energy use. This may also include measures not considered in SAP such as energy efficient appliances or behavioural change measures. Not all dwelling types were able to achieve the maximum number of credits set for Ene 01 and Ene 02 using the package of measures included in this study. This reflects the fact that the upper credit levels are there to reward the best in class, and therefore unlikely to be achievable for all. Conclusion The research illustrates that the approach that is required when improving existing homes will vary considerably between dwelling type and age. It also highlights the property types where the greatest energy and CO 2 reductions can be made. It is therefore important to consider the appropriate package necessary for the house type undergoing refurbishment, depending on the BREEAM rating and number of BREEAM credits targeted The findings also show that across nearly all house types including detached, semi-detached and terraced homes, the minimum energy standard for a BREEAM Very Good rating can be achieved for a reasonable whole house package of measures, equivalent to package P4. The research concludes that irrespective of how energy efficient an existing property is, all properties have the potential to achieve high BREEAM ratings and improved energy performance. Whether a pre- 1919 detached, 1980 s mid-floor flat or post-2002 terrace, there are a range of solutions that are available for delivering low carbon domestic refurbishment, providing savings to occupants and the potential to achieve high BREEAM ratings.

BRE Global Bucknalls Lane Watford United Kingdom WD25 9XX T +44 (0)333 321 8811 E breeam@bre.co.uk www.breeam.com BREEAM is a registered trade mark owned by BRE (the Building Research Establishment Ltd. Community Trade Mark E5778551). The BREEAM marks, logos and symbols are the Copyright of BRE and are reproduced by permission. BRE Trust The BRE Trust uses profits made by BRE Group to fund new research and education programmes, that will help it meet its goal of building a better world together. The BRE Trust is a registered charity in England & Wales: No. 1092193, and Scotland: No. SC039320. 62519 BRE Global Ltd June 2014