RDSAP Manual March 2012

Size: px
Start display at page:

Download "RDSAP Manual March 2012"

Transcription

1

2 Contents Section Introduction Section Energy rating and the EPC Section The RDSAP software Section Property features Section Constructions Section Space heating Section Water heating Section Renewables Section Recommendations

3 Section one Introduction Welcome to this latest release of RDSAP Training Manual. We hope that you find it easy to follow and simple to use. This version of the manual has been produced to coincide with the introduction of the RDSAP 9.91 methodology in April 2012, which brings some substantial changes over previous versions.

4 How to use the Manual This manual contains much of the technical information you will need during your training and assessment for the Domestic Energy Assessor (DEA) qualification. However, we may provide supplementary guidance as required in the form of additional handouts. Additional information may also be provided from time to time by other means, such as by . It is advisable to add any supplements to the manual binder because once you are qualified it will be up to you to maintain your knowledge of the latest conventions. The energy assessment industry is a fast developing one and changes are inevitable and regular. It is strongly recommended that you read more widely than this manual on some technical areas such as, for example, building construction. While the basics are covered here, you may wish to continue to increase your understanding of residential construction technology in order that you feel competent to inspect the full range of residential property. A current reading list supplied in Appendix 2 at the end of this manual. Becoming qualified is not just a matter of learning the technical aspects of RDSAP. There are other aspects to consider such as understanding the regulatory framework within which DEAs operate. This manual can be interactive, and in fact, we have deliberately made space available for you to scribble away so please feel free to make whatever notes, reminders or diagrams you need to within the pages. Just make sure that your notes are legible and technically correct as the manual will be a useful point of reference, not just during training, but also for information in the future. There are often times when it is useful to confirm your instincts with a quick check in the manual. The manual is divided into a number of clearly laid out Sections relating to major subject areas, e.g. heating or construction. Within each Section there are sub-sections containing subjects that are referred to in the contents page, for ease of location.

5 2. Section two Energy rating and the EPC History of energy rating Energy rating of buildings is not new and it has long been known that as much as 27% of our total CO2 emissions come from our homes. SAP is used to produce energy ratings for new homes. RDSAP The Reduced Data SAP (RDSAP) is the government approved survey system used to produce the Energy Performance Certificates (EPCs) required by 2002 European Energy Performance of Buildings Directive (EPBD), which came into force in The EPBD seeks to reduce the amount of CO2 which is emitted as a result of heating, lighting and providing hot water to UK homes, many of which have remained poorly insulated. With certain exceptions an Energy Performance Certificate (EPC) is required whenever a residential property is sold or let and is currently valid for 10 years. The EPC gives prospective buyers and tenants up- front information about the energy efficiency and running costs of the property they are considering occupying. The rating system that the EPC illustrates means that they can compare one property against another before choosing and, it is hoped that landlords and vendors would feel some pressure to upgrade their properties to make them more marketable and thereby some progress could be made in reducing the levels of CO2 emissions. The physical RDSAP survey of a home required to produce an EPC is a non-invasive inspection. The DEA is not required to lift carpets to see the floors or to drill holes in the walls to see the insulation and is therefore limited in what they can see of the property. There may be some reliance on documentary evidence instead. RDSAP produces an EPC that, on its front page, shows an eye-catching and easy-to-read graphical illustration of the energy performance of the property similar to the labels displayed on white goods.

6 The EPC The page 1 of the EPC shows the energy efficiency rating graph which illustrates the current rating (on the graph above of 49 or band E) and the potential rating (above of 75 or band C) that the property could achieve if the recommendations contained in the report were implemented. The graph starts at 1 in the red bar and extends to 100 in the dark green and represents the cost to the occupant of heating, lighting and hot water for the property. A low number in the red is an inefficient property and a high number in the green is an extremely efficient one. It is possible for a property to score above 100 but this is extremely rare and would normally involve exporting energy gained from a renewable energy system. It means that the cost of the energy consumption of the property is more than met by the income obtained from exporting surplus energy. On the front page the EPC will also provide an indication of the costs of providing heating, hot water and lighting to the property over a three year period along with a clear indication of the financial incentive to implementing the recommendations, i.e. the savings that could be made. It is important to note that these costs will not necessarily correlate with the occupant s billing history because RDSAP uses standard occupancy assumptions that may not reflect actual occupancy of the property.

7 Standard occupancy Standard occupancy is an important concept in energy rating because, in order to provide a means by which readers of an EPC can compare one property with another, a level playing field must first be achieved.

8 For example, you might inspect a five-bedroom house occupied by a single person whose running costs are lower than if the property were occupied by a family of five people. Conversely, you might encounter a large family inhabiting a very small flat and who use a lot of hot water and considerable heat. The RDSAP rating ignores the occupants and their behavioural patterns, focusing instead on the dwelling itself; its fabric, heating, lighting, etc. RDSAP works by measuring the annual cost of maintaining an acceptable temperature regime in a dwelling. The assumption is that an acceptable regime would be achieved by heating the property to 21 degrees Celsius in the lounge and 18 degrees Celsius in other habitable rooms for 9 hours per week day and 16 hours at weekends. The calculation uses the size of the property to estimate a suitable average number of occupants and hence the hot water requirements for that number of occupants. This method is sometimes referred to as an asset rating. Recommendations The subject of recommendations is dealt with in more depth in Section nine of this manual. The EPC presents the reader with recommendations for improving the fabric of the building, the heating, lighting and other areas. The top three recommendations are shown on the first page of the report (see below). There is also a first reference to the Green Deal in this section. The improvements suggested help to prioritise the different ways of saving energy, illustrated over a three year period.

9 Some improvements make obvious economic sense, and others are really only realistic considerations when a particular item requires replacing. Loft insulation and hot water cylinder insulation, for example, are obvious improvements, as they are cheap to purchase, can be easy to install, and often save enough energy to produce real savings in less than a year. On the other hand, double-glazing and a replacement central heating boiler are examples of improvements that cost far more, and this means that they often will not be replaced unless there is the need, i.e. a broken boiler or rotting/leaking window frames are present. The idea is to present the homeowner with enough information to help them decide on the best value for money when investing in energy efficiency. The recommendations report offers an independent comparison of the options for example: installing new double-glazing (often only adding 2-4 SAP points) with a new boiler and controls (which could easily add in excess of 10 SAP points). The running costs associated with the ratings can also help the consumer to identify the best ways to target their money to reduce fuel bills. Energy efficiency measures do make sense for cost and comfort. A typical 1960s house could have its fuel bills reduced by 200 per year for an expenditure of about 500 an effective rate of return of 40% tax-free and inflation proof. Warmer, less draughty properties are generally more comfortable to live in and may command higher prices when sold or rented. Furthermore, our understanding of the ill effects of carbon dioxide and other pollutants on our environment should be reason enough to act.

10 Other information on the EPC Page 2 of the EPC also contains basic details of the property s construction, levels of insulation, heating system, hot water system, lighting and other features and these are given an easily interpreted star-rating, depending on how efficient they are deemed to be. It is important that DEAs record these elements accurately during their inspection. Page 2 also shows details of any low and zero carbon technologies present. Page 3 (detail above) contains the full set of recommendations and an indicative cost for each, together with suggested savings per year. The green ticks suggest the measure could be applicable for Green Deal funding and the orange tick suggests partial Green Deal funding. Page 4 of the EPC (detail above) shows the environmental impact rating graph which illustrates carbon emissions associated with the property, expressed in tonnes of carbon dioxide produced per year.

11 Page 5 of the EPC (detail above) shows the details of any Green Deal charge associated with the property, including details of the installed measures, in this case loft insulation and double glazing, their monthly costs and savings, balance to repay and the interest rate charged. Survey of the property Data collection Consider for a moment what it is that you are actually doing when assessing the energy performance of a property. An input of heat is needed to replace the heat lost through the envelope of the dwelling. Some of this comes from natural solar input or is generated by the occupants, but most of it has to be supplied by the heating systems. So the DEA collects information on those characteristics of the dwelling which influence the heat loss; as well as the characteristics of the heating system. While learning the process of inspection you can follow a survey form which will prompt you with the data items you need to record while at the property. Take care not to miss anything at the property as doing so may mean you are forced to return again later. When completing the survey forms, make your entries clear and if you do not use a section strike a line through it to show that you have not simply forgotten to complete it. For example, if there are no extensions strike a line through the section of the form that relates to extensions.

12 Your site notes or survey forms are very important, firstly as a vital part of the training and assessment process, but also (once you are qualified) as part of the auditing process that DEAs are subject to by all accreditation schemes. You are obliged to maintain your site notes for a period of no less than 15 years. It is perfectly possible that you could be challenged on your findings long after the EPC was completed and your notes must be good enough to defend your position in this event. You will collect information on the building, the age, construction and insulation present in the dwelling, together with information about the heating and hot water systems and any renewable energy systems. Your survey forms should provide supporting evidence to back up any decisions you make. For example, it is not good enough simply to state that the property was built in You must provide sufficient evidence to allow an auditor (or other reader of your notes) to be confident in your decision. Did you see the deeds and photograph them? Did the planning office provide a date? Did you rely on stylistic clues and if so what were they? The thermal envelope In order to calculate the heat loss of the property, the software needs to know the area of the walls, the external wall thicknesses, the floor areas, and the roof area (assumed to be the same as the floor area) together with details of any insulation present. The assessor measures these areas as well as the room height and the length of the heat loss walls. The subject of property measurement is covered in detail later in this manual. Results of thousands of previous energy surveys allow the software to accurately estimate the area of the windows for a property of any type and age without the need to actually measure the windows, in most cases. It is necessary that the assessor follows the conventions so that all DEA end up with the same result.

13 U values DEAs using RDSAP are not required to calculate U-values, but some understanding of them is important because the option of entering U values directly to the software is available if the assessor is presented with documentary evidence that fully supports the U values entered. U-values are numbers with units of W/m2K (Watts per metres squared Kelvin), e.g W/m2K. The U-values tell us the rate of heat loss of a wall, window, floor, etc. A built element with a larger U-value will have a higher rate of heat loss, so the built element will leak heat more quickly. The heat loss through the fabric of the building depends upon the construction method; material and thickness of each part of the envelope; and upon the area of that part. By collecting descriptions of the building age and construction, the energy rating software can assign a suitable rate of heat loss and U- value to each built element of roof, wall, floor etc. It can do this because the U-values are usually characterised by the building procedures of the period and (since 1966) by the energy design standards demanded by successive upgrades of modern Building Regulations. However, what the software needs to know is whether any changes to the insulation standards have occurred since the property was constructed. So for instance, a house built during the period of has an assumed wall U-value of 1.0. If the wall has had cavity wall insulation fitted the improved U value falls to 0.40, a reduction of 60%. Such an insulation upgrade will substantially improve the EPC rating. RDSAP age bands are considered in Section Four of this manual. Heating systems The annual cost of providing heating (including water heating) to a home depends upon the amount of energy required to maintain the set standard of comfort, after allowing for the heat losses, the efficiency of conversion of energy to useable heat, the quantity of fuel needed to provide the energy, and the price of fuel. It will also be reduced or offset by the presence of any renewable energy system. Information is needed on the type of the primary heating system; details of the primary heat source (e.g. the central heating boiler); the fuel used (including for electricity the tariff, i.e. on-peak or off-peak); the use made of secondary space heating systems; the type of water heating system; the type of hot water storage, if any; as well as types of controls and renewable energy systems incorporated in the space and water heating systems. Heating is considered in more detail later in this manual.

14 How does the software use the data? The software process When the DEA enters data into the software, it then uses the input data, combined with its built-in defaults, to carry out the calculations. The output of this calculation is the predicted running cost for the home under standard. The predicted running cost is then divided by the floor area of the home and this figure is then converted into an energy efficiency rating and an environmental impact rating, somewhere on the A to G scale. The calculation is then used to estimate the savings from installing energy efficiency improvements, so that the energy advice report can make recommendations for improving the home and give a predicted potential rating if they were to be carried out. The Landmark Register The report is produced, reviewed by you and finalised when you are happy that its content can be finalised. Once finalised you cannot later change the report or its content. Once you are qualified, your EPCs will automatically be lodged on the Landmark Register where all EPCs are stored. During training and assessment you will not be able to lodge reports and do not have to worry about creating a real EPC for a property. You are able to practice with the software as much as you need to.

15 3. Section three RDSAP software To Produce EPCs you need to use one of the softwares provided by different accreditation schemes. All softwares use same conventions and methodology. While training you will have access to a training account which will allow you to use most of the features of EPC online but will stop short of allowing you to produce real EPCs. You are able to practice with the software without fear of actually creating an EPC for a property. The software that you will use at this stage is essentially the same as the live software that you will use once qualified. Purpose of EPC Marketed sale Non-marketed sale Rental (social) Rental (private) This option should be used for EPCs required for marketed sales (known as single survey in Scotland). This option should be used for Right to buy or sales that are not advertised. For example the sale of a house by one family member to another. This option should be used for dwellings owned by social landlords; this could be local authorities or housing associations. This option should be used for rental EPCs from the private sector. Institutions such as universities will fall into this category. Not sale or rental This option should be used if the EPC regulations do not require and EPC for the dwelling, for example, if a homeowner wanted an EPC just to see how energy efficient their dwelling is. There is a field on this page that asks if the report is created from existing data. This refers to the practice of cloning, whereby data is used from previous EPCs. This practice is outside of the scope of this manual and requires additional training. Further information may be gained by contacting NES. Consequently that field and the next, which asks for a reference number, should be left blank.

16 General details Here you are required to enter some fairly self-explanatory information about the property such as the detachment, the number of storeys and the number of extensions. You will be asked whether you measured internally or externally. Internal or external measurements The measurements required are: The floor area The exposed perimeter Room height on each storey Exposed perimeter includes the wall between the dwelling and an unheated garage or a separated conservatory and, in the case of a flat or maisonette, the wall between the dwelling and an unheated corridor. Internal dimensions are permissible in all cases. When using external measurements for a dwelling joined onto another dwelling (semi-detached and terraced houses) the measurement is to the mid-point of the party wall. Flats and maisonettes are usually measured internally. Whichever is chosen the same basis must be used for all parts of the dwelling. Room heights are always measured internally within the room, from carpet level to ceiling. The software automatically makes an allowance for the thickness of intermediate floors.

17 The ground floor area must not include any: Integral or adjoining unheated garages (a heated garage is defined as one which contains fixed heat emitters linked to a main/central heating system) Stores, coal sheds or other external (thermally separated) unheated spaces Thermally separated conservatories Unheated, thermally separated porches Terrain type The terrain type must be recorded for every survey. This allows the software to assume an average wind speed for the area. The average wind speed is used in the calculation of the benefit of a micro wind turbine. Even if a wind turbine is not present the terrain type must be recorded to enable the software to assess whether a recommendation for a wind turbine is viable. See the table for the choices and note that unless you are in a city centre location, suburban is the most common choice. Dense urban City centres with mostly closely spaced building of four storeys or higher Suburban Towns or village situations with other buildings well spaced Rural Open country with occasional houses and trees Mains gas available If there is a gas meter at the property or a mains gas appliance then you need to record that mains gas is available. The fact that there is a gas supplied to other properties in the street does not mean that mains gas is available to the property you are inspecting. Number of rooms and habitable rooms The software asks for the number of habitable rooms and whether any of these are unheated. Habitable rooms include any living room, sitting room, dining room,

18 bedroom, study and similar; and also a non-separated conservatory. A kitchen/diner having a discrete seating area also counts as a habitable room. A non-separated conservatory adds to the habitable room count if it has an internal quality door between it and the dwelling. Excluded from the room count are any rooms used solely as a kitchen; utility room; bathroom; cloakroom; en-suite accommodation and similar; any hallway; stairs or landing; and also any room not having a window. For open plan dwellings count all spaces thermally connected to the main living area (e.g. a living/dining room) as one room. For a kitchen to be a kitchen/diner it must have space for a table and 4 chairs. A lounge/dining room where the door was temporarily removed (i.e. architrave and hinges still there) is two habitable rooms. A lounge/dining room with the door permanently removed (hinge holes filled etc) is one habitable room. Flats and Maisonettes Note that flats are dealt with in more depth in Section Four. Semi-exposed elements This page asks for details of the flat or maisonette you are entering and will simply not apply if you are dealing with a house. If you are entering a flat you will need to enter the flat type; that is whether it is a basement, a ground floor, mid floor or top floor flat. You will also be asked to enter the flat s position in the block. If it is a first floor flat, the floor position will be 1 and the software helps you by providing the choices. Under semi-exposed elements the software asks if there is a corridor and, if so, what type and what length. A more detailed explanation of this and some examples is contained within Section Four of this manual.

19 Age and roofs Unknown or asbuilt Depending on the element, you will have the option of entering the insulation as being as-built or unknown. Using either will mean that the software defaults to the insulation depth that apply according to the date you have entered for the property s (or extension s) date of build. However, with unknown there will not be a recommendation for further insulation. (Take for example a roof in a 1900 terraced house, over the page.) If you are unable to access the loft you might enter that the loft insulation is unknown. The software will assume the roof is insulated as it would have been when new (in 1900 that would be none) and there will then not be a recommendation for increasing the insulation. This is because the roof has not been assessed for its suitability; there might be a condensation problem or there might already be 300 mm of insulation. This does illustrate why it is so important for the DEA to make every effort to inspect the roof space where possible. Choosing as-built for a wall for example, means the wall is as it was when built. For a 2007 house cavity walls as-built means the walls are built to 2007 Building Regulations and will therefore be insulated. Property age Property age is extremely important to the software. The property age is required for the software to select the default heat loss values (U-values) for the wall, roof and floor and to calculate the window area. Clearly properties of different ages will perform very differently and the general rule is that the newer the property is the better the U values of its component parts. Houses of different ages also have different window to wall and window to floor ratios. The age bands for newer properties correspond to changes in Building Regulations and the older age bands, pre-1966, with changes in methods of building. The RDSAP age brackets are as follows and the job of the DEA is use their best efforts to date the property accurately and place it in the correct age band. Age bands Pre-1900 A E I B C D E F G M J 2007 onwards K

20 Property age and how to date property is further covered in Section Four. Roofs RDSAP deals with roofs on the main property and any extensions. Each is entered separately, starting with the construction type. Roofs types, their insulation and the options available in the software are described in Section Five page 24. walls and floors This section deals with walls and floors and their insulation levels. For both, this is where you will enter the construction type, insulation type, insulation thickness and any U values that are known. For walls the overall thickness of the wall is required and whether there is a dry lining. Note that walls and floors are covered in detail in Section Five. Aalternative wall This section of the software relates to alternative walls only and you will simply leave the section untouched if there is not such a wall at the property. You would enter an alternative wall type where the property has a significant area of wall that is of different construction or insulation level than the building part it belongs to, but this wall type cannot be identified as an extension since it does not surround any floor area. Where an area of alternative wall exists but it constitutes less than 10% of the total external wall area of the building part it belongs to, it can be ignored. The 10% of the wall area is identified including the windows and doors; it is only when measuring to the area of wall calculate the area to be included into the data summary that the area of any windows and doors is subtracted. This means that if you believe there to be an alternative wall then you will have to measure any window and door openings. Alternative wall types can occur as part of the main house, or part of any extension and you should record which of these applies. It is possible to enter up to five alternative walls. Note that alternative walls are dealt with in detail in Section Four.

21 Left: The tile hung area of the wall might be alternative, if you can determine its construction to be different than that of the rest of the house. In this example, it looks to be approximately 10% of the total wall area, but further measurement is required. Dimensions The software requires the following data for the main property and each extension: The floor area in metres squared. The room height in metres to the nearest centimetre. The heat loss perimeter (HLP) in metres. See Section Four of this manual for detailed RDSAP measuring conventions. Rooms in the roof Note that roof rooms are dealt with in detail in Section Four. This section of the software deals with rooms built within the roof space of a property and the section will simply be ignored if there is not one at the property. A room in the roof is a habitable room built into what would normally be a loft space, above the main part of the dwelling, or above any extensions. Note that for such a loft space to qualify as a room in the roof for energy assessment purposes, it must incorporate fixed staircase access, i.e. not just a loft ladder. It will usually have sloping ceilings for part of the area and may also include dormer or Velux windows. If a roof room is present, the software requires you to enter the age range, floor area and the details of the insulation present. If you are able to obtain documentary evidence of the U-values of the component parts, you can enter this information in the extended data section on roof rooms (see Section Four).

22 Openings windows Note that windows and glazing are dealt with in detail in Section Four. This section of the software deals with the openings in the property created by windows and also by any open fireplaces and ventilation systems. Details of any draught proofing are also entered here. The software asks that you enter whether the window area is typical of that type of property or whether it is more or less than typical. It also asks that you enter the proportion of the property s window area that is multiple glazed if any and what type of multiple glazing is present. if 60% of the area (including the frame) of a door is glazed, they are treated as windows. Open fireplaces On the same page of the software in the ventilation section you are asked to enter the number of open fireplaces. These contribute greatly to the ventilation of the property and will remove some of the warmth generated by the heating. Note that open fireplaces are dealt with in detail Section Four of this manual. Ventilation The software asks you to enter the ventilation method and the options are: Natural ventilation this means the property is ventilated in the traditional way by windows and possibly vents in the walls and windows. Mechanical, supply and extract this is a whole house mechanical system which both introduces fresh air into the property and extracts heat from the stale air. Bathroom and kitchen extractors DO NOT qualify as mechanical ventilation. Mechanical, extract only this is a whole house ventilation system which mechanically extracts stale air from the property passive vents or gaps in the fabric of the building. This is sometimes known as MEV. Bathrooms and Kitchens extractors do not get classed as MEV. Air conditioning The presence of air conditioning in the property simply requires a box to be ticked in the software. Extended openings This section is for use when there is much more or much less than typical areas of glazing at a property and enables the location, dimensions, glazing type, orientation, U value and g value of each window to be entered individually. See also Section Five.

23 Space heating Main heating systems This important section of the software deals with the MAIN heating systems within the property. It is possible to enter either one or two main heating systems and apportion the amount of work each does in maintaining the acceptable heating regime that was described earlier in this manual. The Product Database which contains specific technical information on a wide range of heating systems is located in this section of the software. Searching it for a system just requires clicking on the appropriate tab. A number of entries are required about the main heating systems and given the complexity and range of possible entries, these have been covered in the heating section of this manual (Section Six).

24 Electric meter See Section Four of this manual for more about electric meters. The first entry to be made in this section is to describe the electric meters present. The choices are: Dual rate Single rate Unknown 24-hour Heating systems Details of any secondary heating system are required including the fuel and system type. For a detailed definition of what a secondary heating system is please see Section Six of this manual. water and secondary heating The secondary heating system should be entered next and this important area is covered further in Section Six. Details of the water heating system should be entered in this section of the software, including the heating type, system, fuel and immersion heater type, if applicable. If there is a hot water cylinder, its size, insulation type and thickness and whether there is a cylinder thermostat should be entered. This is covered in more detail in Section Seven of this manual. Bath and shower details are also recorded in this section, as follows: Number of rooms with bath and/or ANY shower Rooms with MIXER shower AND bath Rooms with MIXER shower and NO bath This enables the software to make the appropriate recommendations in respect of waste water heat recovery systems (WWHRS). Heat recovery systems This section of the software asks for the number of waste water heat recovery systems (see section 6 for details) and also allows for two flue gas heat recovery systems (FGHRS) to be entered. Both systems have their own Product Database which allows for searching for and selecting specific models.

25 Conservatories and lighting If a conservatory is present at the property, its type must be recorded and if non-separated the floor area, whether double glazed, the glazed perimeter and the number of storeys in height it covers should be entered. See Section Four of this manual for a detailed look at conservatories. Low energy lighting Low Energy Lighting includes CFL, LED and fluorescent tubular lighting. You need to record: The total number of fixed light outlets. The total number of fixed low energy lights. Section Four of this manual explains low energy lighting in more detail including the conventions on counting combinations of lights. Renewables This section covers renewable energy systems; notably wind turbines, solar photovoltaics and solar hot water. Renewables can require some complicated software entries and these are covered in detail in Section 8. Addenda This section in the software enables the DEA to better describe the property s features within the format of the report by allowing certain anomalies to be explained to the reader. These include statements that explain that there are wall types that do not correspond to the options available in RDSAP and the presence of swimming pools. This section is the last of the data input screens and clicking next at this point will take you to the Results: Recommendations section. The list of addenda is some optional statements that can be added to the EPC if required. They describe situations which as yet cannot be modelled in the software. The aim is to reduce complaints from householders about features that are not adequately described on the EPC. The list of addenda is currently as follows and is occasionally updated. In case you are wondering why the list is numbered 1, 4, 5, 6, 8, 9, it is because the missing numbers from this sequence represented addenda that have now been removed from the list because the software has developed to the point where it can deal with those issues. The screen shot below shows section P15 of the RDSAP software which allows the assessor to select addendum.

26

27 Results: Recommendations screen If you have fully completed each section so far, then at this point you will see a SAP Result expressed as a figure between 1 and 100. Also you will see a list of recommendations made by RDSAP. If the property has walls of cavity construction, there are additional questions about whether or not the cavity walls are hard to treat. That is, whether there are access issues such as adjoining conservatories, garages or other outbuildings that might make the physical installation of cavity fill insulation difficult. This could also include any situation where access by means of a 5 m high ladder is not possible such as at higher buildings or flats. Cavity fill may still be possible but will be more expensive. Cavity walls which are within areas of high exposure may be subject to higher levels of driving penetrating rain. The DEA should refer to the map below to decide whether or not the property is in an area of high exposure and if so the appropriate box should be ticked and an addendum generated. Cavities which are less than 50 mm in width may require specialist cavity insulation or may not be suitable at all. Ticking the box to say that walls have narrow cavities will produce the appropriate addenda to inform the client of this. Narrow cavities may be identified by a total wall reveal thickness of less than 250 mm, yet a stretcher bond pattern to the brickwork.

28 Property features 4. Section four Property features introduction Some questions contained within this Section only apply to flats and maisonettes. Where this is the case, it will be clearly stated in the text. Some of the question titles (for instance, the number of rooms) appear to request the obvious, but do make sure you read everything through at least once, as there are a few points to remember. Basements A basement is defined as a part of the heated and occupied area of the dwelling that is fully or partly below external ground level and where 50% or more of the external wall area loses heat to the adjacent soil rather than to the external air. In order to be included within the energy assessment, a basement must be accessed by a permanent fixed staircase such that a person can walk down it facing forwards, and it is either: Heated by fixed heat emitters, or Open to the rest of the dwelling. If recorded the basement will become the ground (or lowest occupied) floor. Note that there do not need to be any habitable rooms present in the basement. When incorporating a basement in the assessment do not mix internal and external measurements. If a basement is included in the assessment, it is likely that internal dimensions will be used throughout the dwelling.

29 Bay windows You are required to measure and enter details of all bay windows if they increase the floor area of the property. If any of the building elements of the bay are different to the rest of the house, i.e. the walls, floor or roof, then you will need to enter the bay window as an extension. Remember that an extension does not have to have been built later. The ability to enter up to four extensions gives you the flexibility to more accurately record such perturbations as bay windows. The bay in the photo is rectangular but bay windows can also be either a trapezium shape or a semi circular shape. The following diagrams should assist you in calculating the area of a bay window.

30

31 Conservatories what is a conservatory? For RDSAP a conservatory is a structure with at least three quarters of its roof and at least half its external walls glazed. If the structure in question does not meet these requirements then it should be considered as an extension. The treatment of a conservatory depends on whether it is separated or non-separated from the dwelling. separated or non-separated A separated conservatory is effectively ignored for the purpose of calculating the dimensions and heat loss perimeters, although you do need to note whether or not it has fixed heaters. Most modern conservatories fall into this category; they will often have external quality upvc doors separating them from the house. As a rule of thumb, if you imagine the conservatory was removed, you would need to ask: Would the doors offer sufficient protection from the elements? External quality doors are usually thicker and have features such as double-glazing, locks, bolts and weatherproof surrounds. A non-separated conservatory will either have internal quality doors the thin, lightweight type that sometimes separate rooms, or will be open to the adjoining room. The doors may have been removed or the conservatory could have been designed to extend the room and have no doors. Consider whether the non-separated conservatory alters the number of habitable rooms. Several items of data are required about the non-separated conservatory: Floor area, measured internally Glazed perimeter (ignore areas of brick wall) Whether double glazed Conservatory height in storeys

32 Images 1 and 2 show an example of a separated conservatory, with sliding patio doors. These are of exterior quality, are double glazed, provide a good seal, and are lockable. Images 1& 2: Exterior quality door note they provide a good seal, are heavy weight and lockable. Images 3 and 4 are of a non-separated conservatory. The interior quality doors are not deemed to thermally separate the conservatory from the main dwelling. Although it is not visible from the images, these do not close properly owing to the lack of wooden trim to the frame, the latches are missing and they do not lock. Images 3 & 4: Interior quality doors note they do not shut properly and do not provide a good seal to the doorway.

33 To recap: In RDSAP there are four options for conservatories: A non-separated conservatory is like an extension in that the heat loss perimeter of the house does not include the length of house wall next to the conservatory. This is illustrated in the diagrams below. Conservatory No conservatory Separated conservatory, no fixed heaters No conservatory present either separated or un-separated. A separated conservatory is present, but there is no heating or only portable heating Separated conservatory, fixed heaters A separated conservatory is present and is heated by fixed heaters which may be from the main heating system. Data for nonseparated conservatory A conservatory that is open to, or separated Non-separated by internal quality doors, the main dwelling. conservatory Record the area, height, glazed perimeter and whether it is double glazed. The exposed perimeter for the conservatory should be measured in the same way as for the main house and extension but it is the length of exposed glazed wall that is required. If there are areas of brick wall, these can be ignored. This is illustrated in the diagrams below. Remember to indicate if the conservatory is double-glazed and to estimate the average height of the conservatory relative to the main dwelling storey height.

34 example 1: In this case, the conservatory floor area is 15 m2 and the glazed perimeter is 11 m. House with a non-separated conservatory House heat loss perimeter is: = 25 m Conservatory glazed perimeter is = 11 m Conservatory floor area is: 3 x 5 = 15 m2 In this case, the floor area is 15 m2 and the glazed perimeter is 11 m. example 2: In this second example, the conservatory floor 2 area the glazed is 12 m and perimeter is 7 m. House with garage and nonseparated conservatory House heat loss perimeter is: = 25 m Conservatory glazed perimeter is = 7m Conservatory area is 3 x 4 = 12 m2

35 It is important to note that when calculating house floor areas and that you do not include within these the area and glazed HLPs perimeter of the conservatory. what if the conservatory is not a conservatory? It is not uncommon to find a conservatory that does not meet the RDSAP definition of such; i.e. a structure that does not have half its walls and three quarters of its roof glazed. Garden rooms may have a traditional flat or pitched roof. In these circumstances the structure should be treated as an ordinary extension except that you may need to make use of the more than typical glazing feature of the software which is discussed in the section on windows further on in this Section. passive solar design and sun rooms Separated conservatories provide shelter to the external wall, and also capture solar heat, which will partially warm the house. For most conservatories this effect is very small and both the solar heat gain and the sheltering effect are ignored in the RDSAP energy rating calculation. Some homes have exceptionally large unheated conservatories covering more than one storey and designed as a solar space to deliberately capture solar gain and pre-warm the home. These properties can be recognised by the fact that the conservatory will often extend to the full height of the dwelling and will make up a large proportion of the dwelling floor area. This can be dealt with by using one of the more than typical glazing options see the section on windows. An example is shown in the image below.

36 Detachment Whether the property is detached, semi-detached, terraced or built in another form is important to the software so that it can select the appropriate set of default assumptions, including the pattern of window openings/glazing that should apply. Your choice of detachment will appear on the front of the EPC report. The options are described below. Detached Houses that are described as detached have no party walls and so have exposed wall area on all four sides. Here are some examples. Link detached houses (houses that are essentially detached and are only linked to neighbours by a garage) should also be classed as detached. semi-detached Semi-detached houses share one side (the party wall) with a neighbour. This leaves exposed wall area on three sides. Although end-terrace and semi-detached properties are similar in terms of exposed walls there is a slight difference in the typical window areas for the two built forms. An end-terrace property will usually have a blank gable end wall, where as a semi-detached house will most likely have additional glazing in the side elevation, being glazed on three sides, rather than just front and back.

37 End-of-terrace As the name suggests this is the first or last house in a terraced row. End-of-terrace properties have three exposed sides like a semidetached, but tend to have blank end walls. This means that the typical pattern of glazing will be the same as for a mid-terrace. Mid-terrace Mid-terrace houses have two party walls (one on either side) and two heat loss sides (front and back). If the terrace has a passage through to the back of the house, classify it as a mid-or end-terrace house, include the length of the passage wall in the lowest floor heat loss perimeter and consider identifying the heat loss floor above the passageway through the extension option. Enclosed midterrace These houses are often called back-to-backs. Back-to-back properties are essentially terraced houses that also back onto another terraced row. From the street they will look just like a terraced house, but the rear of the property joins the back of a house from the next street, which gives us the phrase back-to-back. They have only one heat loss wall, as the side walls are common with their neighbours and the rear wall is common with the property on the terrace of houses at the rear.

38 Be careful if a house is described to you as back-to-back sometimes this term is used to describe terraces that are built very close together with only a narrow yard separating them. These back-to- backs are not enclosed, they are normal terrace houses. Enclosed end terrace An enclosed end-terrace will be the first or last house in a terraced row of back-to-back houses. They have two adjacent heat loss walls, and two adjacent party walls. Modern cluster homes are also enclosed end-terraces; the block is essentially four enclosed end-terraces without any mid-terraces in between. A residential property adjacent to commercial premise It is possible to record a dwelling next to a shop or office in the following way: If a dwelling has a commercial property below, record as partially heated space below. If a dwelling has commercial premises above, record as other dwelling above. If a dwelling has commercial premises alongside it, treat as a nonheat loss wall.

39 Dimensions Introduction Property dimensions are an important part of the energy rating calculation remember that the energy rating is calculated by dividing the predicted fuel costs by the floor area so it is important that the floor area is calculated accurately. Your floor area calculation is displayed on the front page of the EPC. The heat loss perimeter (HLP) is needed to assess the heat losses through the building fabric and the room height is important, since the ventilation loss depends on the building volume, which is calculated using the room height. For a simple property such as a bungalow or a flat, the actual data entry could be as few as three items floor area, room height and heat loss perimeter. For many houses, the floor area and HLP will be the same on all floors (but not the room height!), so the amount of data to input is often less than you might think. However, there are properties where the measuring can be more complicated. Imagine an irregularly shaped house with numerous extensions, bay windows, conservatory, etc; in such a case there is considerable measuring to do which will require a systematic approach. Floor plans A floor plan showing dimensions (and other property features) is essential in every case, even the simple properties. The plan should, among other data items, show the horizontal dimensions of the property, the room heights and the HLP. It is highly recommended that you highlight the HLP with a different colour, firstly to aid you in ensuring accuracy and secondly to allow someone checking your work to be able verify your accuracy. : A well-marked floor plan: The plan should also show the position of lights, windows, heat emitters and anything else that is relevant to the inspection.

40 Internal or external measurements For houses, internal or external dimensions can be used depending on which are easier to measure on site. If you measure externally, the program uses those external dimensions by adjusting them to allow for the wall thickness, but the entire survey needs to be carried out using either internal or external dimensions. Flats are usually measured internally, as is room height and room in roof floor area. You must not change between internal and external when measuring different parts of the house. Floor area At a straightforward rectangular property, the floor area is calculated simply by multiplying the length of the property by the width. By using external measurements you will be calculating the Gross External Floor Area (GEA) and by using internal measurements the Gross Internal Area (GIA). The software adjusts whichever you decide to use to GIA for the EPC report. Complicated properties will require more dimensions to be taken on site and a more careful and detailed approach to making an accurate calculation. Do not include external unheated porches in the floor area. Do not include unheated areas (such as outhouses, outside toilets, garages or coal stores) that are not accessed via an internal door, even if they are within the footprint of the dwelling. Do include unheated rooms, e.g. internal utility rooms and lobbies, so long as they are within the external envelope of the property and are accessed via an internal door. Heat loss perimeter The external or internal dimensions are used to work out the exposed wall perimeter. The exposed wall (heat loss perimeter or HLP) is extremely important for evaluating heat loss wall areas as well as the heat loss through the ground floor. Therefore it is essential that it is measured accurately. The energy assessor is required to record the heat loss perimeter (HLP) for the main house and, separately, for any extensions. The heat loss perimeter must also be calculated for each floor of the house and any extension(s) present.

Appendix S: Reduced Data SAP for existing dwellings

Appendix S: Reduced Data SAP for existing dwellings Appendix S: Reduced Data SAP for existing dwellings Reduced Data SAP (RdSAP) has been developed by government for use in existing dwellings based on a site survey of the property, when the complete data

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate Georgia House Stud Bradley Road Burrough Green NEWMARKET CB8 9NH Dwelling type: Detached house Date of assessment: 17 August 2011 Date of certificate: 17 August 2011 Reference

More information

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer Archetype: 3250330 Archetype Description: 1965-1975, semi / end terraced dwelling, timber frame walls, oil / gas / electric warm air heating, E This archetype represents 823 dwellings, which accounts for

More information

RdSAP Conventions. Issued 13 December 2012 (v6.0) New and amended conventions for v6.0 indicated by light blue background.

RdSAP Conventions. Issued 13 December 2012 (v6.0) New and amended conventions for v6.0 indicated by light blue background. RdSAP Conventions Issued 13 (v6.0) New and amended conventions for v6.0 indicated by light blue background. Note: This list will be extended as appropriate. # Topic Conventions Issue date 1. General 1.01

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 0 Raleigh Drive CULLOMPTON EX15 1FZ Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Semi detached house 09

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 3 Dwelling type: Mid-floor flat 30, Brunswick Square Date of assessment: 23 September 2008 HOVE Date of certificate: 23 September 2008 BN3 1ED Reference number: 8398-6021-5510-4127-8022

More information

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

Low Carbon Domestic Refurbishment

Low Carbon Domestic Refurbishment www.breeam.com Briefing Paper Low Carbon Domestic Refurbishment Kiruthiga Balson, Gavin Summerson and Steven Stenlund 2 BRE Global Ltd 2014 Permission is granted for this report to be distributed only

More information

Appendix S : Reduced Data SAP for existing dwellings

Appendix S : Reduced Data SAP for existing dwellings Appendix S : Reduced Data SAP for existing dwellings Reduced Data SAP has been developed by government for use in existing dwellings based on a site survey of the property, when the complete data set for

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 2 Bagshot House Redhill Street LONDON NW1 4BY Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Ground-floor flat 09 April

More information

METHODOLOGY. Generated by Stroma Certification 2015 v1.0 WWW.STROMA.COM 2015 EDITION. www.stroma.com/certification 1

METHODOLOGY. Generated by Stroma Certification 2015 v1.0 WWW.STROMA.COM 2015 EDITION. www.stroma.com/certification 1 RdSAP MANUAL METHODOLOGY 2015 EDITION Generated by Stroma Certification 2015 v1.0 WWW.STROMA.COM www.stroma.com/certification 1 CONTENTS contents Stroma Certification RdSAP Methodology Manual Section 1

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 14, Clifton Road, Anfield, LIVERPOOL, L6 4BQ Dwelling type: Groundfloor flat Date of assessment: 27 January 2009 Date of certificate: 27 January 2009 Reference number: 21389078626951619080

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 307 Windsor House Cumberland Market LONDON NW1 4DE Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Mid-floor flat 8361-6824-6900-7049-8026

More information

Energy Performance Certificates (EPCs) and renting homes: A landlord s guide

Energy Performance Certificates (EPCs) and renting homes: A landlord s guide Energy Performance Certificates (EPCs) and renting homes: A landlord s guide From 1 October 2008 landlords are required to provide an Energy Performance Certificate when they rent out a home. An Energy

More information

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part

More information

SAP 2012 IN A NUTSHELL

SAP 2012 IN A NUTSHELL SAP 2012 IN A NUTSHELL The consultation version of the SAP 2012 methodology was published by the Department of Energy and Climate Change (DECC) on January 4th 2012. This article from Dyfrig Hughes of National

More information

Welcome to a warmer home. You could qualify for: www.ieservices.org.uk. Your guide to a gas supply and central heating system

Welcome to a warmer home. You could qualify for: www.ieservices.org.uk. Your guide to a gas supply and central heating system Welcome to a warmer home Your guide to a gas supply and central heating system You could qualify for: Up to 2,404 towards the cost of connecting gas to your home Up to 1,300 towards new gas central heating

More information

Introduction. Two storey & first floor rear extensions. two storey rear 1

Introduction. Two storey & first floor rear extensions. two storey rear 1 Introduction This advice leaflet has been produced to help in the planning of your house extension, by identifying the main points to consider, in order to achieve an acceptable proposal. This leaflet

More information

RdSAP Conventions. Issued xx June 2014 (v7.0) New and amended conventions for v7.0 indicated by light blue background.

RdSAP Conventions. Issued xx June 2014 (v7.0) New and amended conventions for v7.0 indicated by light blue background. RdSAP Conventions Issued xx June 2014 (v7.0) New and amended conventions for v7.0 indicated by light blue background. Appendix 1 on evidence requirements for quality assurance purposes has been added.

More information

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 Report Date: 04/03/2014 Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 About this Advisory Report Energy use in our homes is responsible for almost

More information

PERMISSION A GUIDE FOR EXTENDING A DETACHED OR SEMI-DETACHED HOUSE

PERMISSION A GUIDE FOR EXTENDING A DETACHED OR SEMI-DETACHED HOUSE PLANNING PERMISSION A GUIDE FOR EXTENDING A DETACHED OR SEMI-DETACHED HOUSE Introduction Foreword by Councilor Dave Smith - Chair of the Planning & Highways Committee. Planning Permissions B Owners of

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015 HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015 May 2015 MAYOR OF LONDON Housing Standards: Transition Policy Statement. On 25 March 2015 through a written ministerial statement,

More information

Rainwater Harvesting

Rainwater Harvesting Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth

More information

EPC and Licenses - UK

EPC and Licenses - UK Energy Performance Certificates (EPC) - FAQ TOPIC INDEX 1. NEW CONSTRUCTION BUILDINGS SUBJECT TO A BUILDING WARRANT APPLIED FOR BEFORE 9 JANUARY 2013 2. NEW CONSTRUCTION BUILDINGS SUBJECT TO A BUILDING

More information

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III HOUSES IN MULTIPLE OCCUPATION Space Standards ADOPTED HOUSING STANDARDS:CATEGORY F HOUSES Houses within this category would be of a low priority

More information

Building Warrant Issues

Building Warrant Issues Building Warrant Issues Frequently Asked Questions Introduction This section is intended to help anyone who is unfamiliar with the building standards system in Scotland. The information contained in it

More information

Mission 7: Saving Energy

Mission 7: Saving Energy Mission 7: Saving Energy How can we save energy? Converting one type of energy to another often damages the environment. For example, burning coal to make electricity causes air pollution. That s why we

More information

General Advice. 2 front extensions

General Advice. 2 front extensions Introduction This advice leaflet has been produced to help in the planning of your house extension, by identifying the main points to consider, in order to achieve an acceptable proposal. This leaflet

More information

MAKING YOUR HOME WARMER

MAKING YOUR HOME WARMER MAKING YOUR HOME WARMER INTRODUCTION This guide has been written to help householders take the first steps to improving the homes they rent or own, making them warmer and cosier to live in, and less expensive

More information

25 PARSON STREET WILNECOTE TAMWORTH B77 5BD

25 PARSON STREET WILNECOTE TAMWORTH B77 5BD A traditional semi-detached home ideal for first time buyers offered with immediate vacant possession and being known as:- 25 PARSON STREET WILNECOTE TAMWORTH B77 5BD A.51474 The property is offered complete

More information

General Advice. 2 rear single storey

General Advice. 2 rear single storey Introduction This advice leaflet has been produced to help in the planning of your house extension, by identifying the main points to consider, in order to achieve an acceptable proposal. This leaflet

More information

Introduction to DEAP for Professionals DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP)

Introduction to DEAP for Professionals DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP) Introduction to DEAP for Professionals Introduction to DEAP for Professionals 1 DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP) 2 Introduction to DEAP for Professionals Introduction to DEAP for Professionals

More information

Bespoke ECO2 software for calculating savings: features for software development

Bespoke ECO2 software for calculating savings: features for software development Bespoke ECO software for calculating savings: features for software development When a supplier notifies us of a measure under the Energy Company Obligation (ECO), it must provide the carbon saving or

More information

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012 2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,

More information

Improving the energy efficiency of our buildings

Improving the energy efficiency of our buildings Improving the energy efficiency of our buildings A guide to energy performance certificates for the marketing, sale and let of dwellings April 2014 Department for Communities and Local Government Crown

More information

Do I need planning permission?

Do I need planning permission? Do I need planning permission? Advice for householders on house improvements on house improvements Planning Services www.leeds.gov.uk/planning What does this leaflet cover? Certain minor changes to a house

More information

Dwelling Energy Assessment Procedure (DEAP)

Dwelling Energy Assessment Procedure (DEAP) Dwelling Energy Assessment Procedure (DEAP) VERSION 3.2.1 Irish official method for calculating and rating the energy performance of dwellings This document describes DEAP 2012, Version 3.2.1, dated June

More information

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE

More information

Energy Use in Homes. A series of reports on domestic energy use in England. Fuel Consumption

Energy Use in Homes. A series of reports on domestic energy use in England. Fuel Consumption Energy Use in Homes A series of reports on domestic energy use in England Fuel Consumption Energy Use in Homes A series of reports on domestic energy use in England Fuel Consumption This is one of a series

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED

More information

31 Linden Lane Kirby Muxloe Leicestershire LE9 2EG

31 Linden Lane Kirby Muxloe Leicestershire LE9 2EG 31 Linden Lane Kirby Muxloe Leicestershire LE9 2EG 31 Linden Lane Kirby Muxloe Leicestershire LE9 2EG Newton Fallowell are excited to offer for sale this individually designed and unique three/four bedroom

More information

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Dienstleistung. Certification as Quality Approved Passive House Criteria for Residential-Use Passive Houses Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality

More information

The Government s Standard Assessment Procedure for Energy Rating of Dwellings

The Government s Standard Assessment Procedure for Energy Rating of Dwellings SAP 2012 The Government s Standard Assessment Procedure for Energy Rating of Dwellings 2012 edition This document describes SAP 2012 version 9.92, dated October 2013. SAP assessors and other users should

More information

Get more from your hot water

Get more from your hot water Get more from your hot water 3 action sheet Whether you re choosing a new hot water system or using the one you already have, there are some easy ways to reduce your energy use without compromising on

More information

Department for Communities and Local Government

Department for Communities and Local Government Department for Communities and Local Government Permitted development for householders Technical Guidance April 2014 Department for Communities and Local Government Please note: This technical guidance

More information

Dealing with damp and mould growth

Dealing with damp and mould growth Dealing with damp and mould growth Dampness affects many homes in Britain. There are three main causes of dampness. This guide aims to help you to work out what may be the cause of the damp and how you

More information

Energy Efficient Windows

Energy Efficient Windows Energy Efficient Windows All properties lose heat through their windows. But energy-efficient glazing keeps your home warmer and quieter as well as reducing your energy bills. That might mean double or

More information

Condition Report SAMPLE. Property address. Client s name. Date of inspection

Condition Report SAMPLE. Property address. Client s name. Date of inspection Client s name Date of inspection Contents 1 A B C D E F G H I J K Introduction to the report About the inspection Summary of the condition ratings About the property Outside the property Inside the property

More information

LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION

LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION 1. Minimum Standards: This document sets out the minimum standards required in HMOs located within the London Borough

More information

Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012)

Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012) de Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012) Introduction The rules governing permitted development (that is, whether

More information

WALLS Three common wall types are described below, with their insulation solutions.

WALLS Three common wall types are described below, with their insulation solutions. APPENDIX 5: Building Envelope Insulation is vitally important for temperature controlled buildings. If fuel (and therefore money) is being used to heat a building, less fuel (and money) will be used if

More information

CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME

CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME Press Release CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME Saving money is now our main motivation for carrying out green home improvements ahead of concerns for the environment. One

More information

Energy Performance Certificate three steps towards benefits

Energy Performance Certificate three steps towards benefits Energy Performance Certificate three steps towards benefits Why Energy Performance Certificate? The overall purpose of energy performance certification of buildings is to be economical with energy and

More information

Guide to Improving Your Home

Guide to Improving Your Home Guide to Improving Your Home WELCOME Contents Where to start 03 Improvement ideas 04 Outside 04 Kitchen 05 Living space 05 Bathroom 06 Bedrooms 06 Get more space 07 Add an extension 07 Convert a garage

More information

Green Deal, Energy Company Obligation and traditional buildings

Green Deal, Energy Company Obligation and traditional buildings Technical Paper 17 Green Deal, Energy Company Obligation and traditional buildings Stuart Hay, Nicholas Heath & Gary Pearson The views expressed in the research report(s) presented in this Historic Scotland

More information

Energy usage in households with Solar PV installations

Energy usage in households with Solar PV installations Energy usage in households with Solar PV installations Background The National Energy Efficiency Data-Framework (NEED) is produced and published by DECC to provide detailed information on annual electricity

More information

Residential design guidance: Roof extensions

Residential design guidance: Roof extensions Residential design guidance: Roof extensions Introduction Conversions of roof-space to useable accommodation can be a relatively cheap and effective way to extend residential property. However, roof alterations

More information

Guide to Planning Permission and Building Regulations for Householders Please note that this is an informal guide to planning permission and building regulations for householders. Questions regarding specific

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 3/11 May 2011 Contents: 1 Window defaults in DEAP and use of DEAP Table 6a... 2 2 Solar Space Heating Systems in DEAP... 4 3 Storage and direct electric

More information

The Types of Standard 2 Guidance on the Standards 2 Changes to Legislation 2

The Types of Standard 2 Guidance on the Standards 2 Changes to Legislation 2 CONTENTS INTRODUCTION 2 The Types of Standard 2 Guidance on the Standards 2 Changes to Legislation 2 SCOTTISH CORE STANDARDS FOR ACCREDITED LANDLORDS 3 1 Communication with the Tenant 3 2 Equality Issues,

More information

FABRIC ENERGY EFFICIENCY FOR PART L 2013

FABRIC ENERGY EFFICIENCY FOR PART L 2013 Informing the Part L 2013 consultation FABRIC ENERGY EFFICIENCY FOR PART L 2013 WORKED EXAMPLES AND FABRIC SPECIFICATIONS February 2012 Introduction This report has been produced by the Zero Carbon Hub

More information

Housing Services Guidance for tackling condensation, damp and mould in your home

Housing Services Guidance for tackling condensation, damp and mould in your home Housing Services Guidance for tackling condensation, damp and mould in your home Housing Services - Guidance for tackling condensation, damp and mould in your home Contents Page What is condensation? 2

More information

Measuring Houses and Counting Rooms. Using the ANSI Standards

Measuring Houses and Counting Rooms. Using the ANSI Standards Measuring Houses and Counting Rooms Using the ANSI Standards THIS IS THE AGE OF THE CONSUMER. Home buyers are demanding more and better information when they shop for houses. The State of Michigan has

More information

DOM 8: GUIDE TO THE DESIGN OF ELECTRIC SPACE HEATING SYSTEMS FEBRUARY

DOM 8: GUIDE TO THE DESIGN OF ELECTRIC SPACE HEATING SYSTEMS FEBRUARY DOM 8: GUIDE TO THE DESIGN OF ELECTRIC SPACE HEATING SYSTEMS FEBRUARY 2006 The Electric Heating and Ventilation Association Westminster Tower, 3 Albert Embankment, London SE1 7SL t: +44 (0) 20 7793 3008

More information

WHY BUY NEW DAMP, DRY ROT, WOODWORM, DRAUGHTS, JUST SOME OF THE PERIOD FEATURES YOU WON T FIND IN A NEW BUILD HOME.

WHY BUY NEW DAMP, DRY ROT, WOODWORM, DRAUGHTS, JUST SOME OF THE PERIOD FEATURES YOU WON T FIND IN A NEW BUILD HOME. WHY BUY NEW DAMP, DRY ROT, WOODWORM, DRAUGHTS, JUST SOME OF THE PERIOD FEATURES YOU WON T FIND IN A NEW BUILD HOME. MORE THAN MEETS THE EYE? THE COST OF UPGRADING AN OLD HOME TO NEW BUILD SPECIFICATIONS

More information

Building Control Guidance Note

Building Control Guidance Note Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material

More information

Housing standards: evidence and research. Dwelling size survey. A report prepared by Scott Wilson for CABE in April 2010.

Housing standards: evidence and research. Dwelling size survey. A report prepared by Scott Wilson for CABE in April 2010. Housing standards: evidence and research Dwelling size survey A report prepared by Scott Wilson for CABE in April 2010. This document has been prepared in accordance with the scope of Scott Wilson s appointment

More information

Conservatory warm roof conversion system

Conservatory warm roof conversion system Conservatory warm roof conversion system IS YOUR EXISTING CONSERVATORY ROOF: Too hot in summer or too cold in winter? Waste of valuable living space? Unable to relax to watch TV? Transform your conservatory

More information

Advice to consumer Reference 50.1 May 2013. Condensation. Some causes, some advice.

Advice to consumer Reference 50.1 May 2013. Condensation. Some causes, some advice. Advice to consumer Reference 50.1 May 2013 Condensation Some causes, some advice. 03 Contents The issue 04 What is condensation 06 The factors governing condensation 09 How double or triple glazing helps

More information

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs. Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs. Fuel for thought Choosing the right heating system for

More information

Information for the Supply Chain on Green Deal Measures. Version 1

Information for the Supply Chain on Green Deal Measures. Version 1 Information for the Supply Chain on Green Deal Measures Version 1 January 2013 Contents Introduction... 3 Introduction to the links between Green Deal measures and the Green Deal assessment tools... 4

More information

Guidance on loft conversions in two-storey houses

Guidance on loft conversions in two-storey houses Guidance on loft conversions in two-storey houses Technical guidance for building control surveyors, designers and installers 01 Guidance on loft conversions in two-storey houses Technical guidance for

More information

Key energy-efficient features of your new home

Key energy-efficient features of your new home Key energy-efficient features of your new home Your thermal envelope The thermal envelope, or shell, of your home (walls, roof and floor) is designed to keep you dry and comfortable. It protects you from

More information

extending your home home extensions design guide draft

extending your home home extensions design guide draft extending your home home extensions design guide draft september2004 extending your home home extensions design guide draft september2004 foreword Welcome to Birmingham City Council s guide to help you

More information

windows doors conservatories

windows doors conservatories windows doors - conservatories Enhance your home and enrich your life with home improvement products from BBH windows doors conservatories Designed, made and expertly installed for your beautiful home

More information

A guide to the compilation of Registers of Scotland statistics

A guide to the compilation of Registers of Scotland statistics A guide to the compilation of Registers of Scotland statistics Contents 1. Introduction and background... 1 1.1 UK House Price Index... 1 1.2 Quarterly statistical release... 2 2. Administrative procedures

More information

GREEN DEAL Saving money by understanding the Energy Agenda. Dave Princep BSc LLB MCIEH

GREEN DEAL Saving money by understanding the Energy Agenda. Dave Princep BSc LLB MCIEH GREEN DEAL Saving money by understanding the Energy Agenda Dave Princep BSc LLB MCIEH Energy Efficiency Energy Efficiency What a difference a years makes! Energy Efficiency 2010 Energy Efficiency 2011

More information

First Time Home Buyers Energy Efficiency Workshop Guide

First Time Home Buyers Energy Efficiency Workshop Guide First Time Home Buyers Energy Efficiency Workshop Guide Why is efficiency important when buying a home? Affordability: lower utility bills Environmental responsibility: reduces your carbon footprint and

More information

The Effects Of Fuel Poverty. Pauline Sandell Fuel Poverty Advisor

The Effects Of Fuel Poverty. Pauline Sandell Fuel Poverty Advisor The Effects Of Fuel Poverty Pauline Sandell Fuel Poverty Advisor Who we are Centre for Sustainable Energy Set up 1979 Over 45 staff Energy Saving Trust Advice Line Funded by the Energy Saving Trust Free,

More information

Exempted Development - Frequently Asked Questions

Exempted Development - Frequently Asked Questions Exempted Development - Frequently Asked Questions Important Pre-Conditions Please note all exempted development is subject to certain restrictions as set out in Articles 6, 7, 8, 9 and 10 of the Regulations.

More information

Building Condition Assessment Report

Building Condition Assessment Report Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.

More information

Minimum Housing and Health Standards

Minimum Housing and Health Standards APPENDIX M.O. 57/2012 Minimum Housing and Health Standards Original version July 20, 1999. Revisions to Part lll, Housing Premises, sections 3 and 4, June 30, 2012 (all revisions are bolded and underlined).

More information

SIP (STRUCTURAL INSULATED PANEL)

SIP (STRUCTURAL INSULATED PANEL) SIP (STRUCTURAL INSULATED PANEL) KINGSPAN TEK ACORN SIP ABSTRACT BUILDING SERVICES Ltd Kingspan TEK is the manufacturer and supplier of the panels and components. Acorn SIP are the Architects who individually

More information

Walsall Council Validation Guide for submitting a Householder Planning Application

Walsall Council Validation Guide for submitting a Householder Planning Application Walsall Council Validation Guide for submitting a Householder Planning Application Householder Planning Application Guide Introduction This guide offers help to people who are submitting a Householder

More information

Dorchester Dorset. Guide Price 410,000

Dorchester Dorset. Guide Price 410,000 Dorchester, Dorset Dorchester Dorset A detached 4 bedroom chalet style house on a corner plot with views towards open countryside in a favoured location on the edge of Dorchester. EPC Band D Guide Price

More information

Condensation. Some Causes, Some Advice

Condensation. Some Causes, Some Advice Condensation Some Causes, Some Advice The Problem Condensation on windows and in conservatories, and the damage it does to paintwork, curtains, wall coverings and window fittings, are problems frequently

More information

Property Accreditation Standards 2014/2015

Property Accreditation Standards 2014/2015 Property Accreditation Standards 2014/2015 Promoting responsible renting of student housing in the city of Southampton Letting period 1st July 2014 to 30th June 2015 Version 1, 10/12/2013 All properties

More information

CONTENTS 1 INTRODUCTION 2 POSSIBLE INSTALLATION DIFFICULTIES 3 OUTLINE OF THE ASSESSMENT PROCEDURE 4 PURPOSE OF THE ASSESSMENT PROCEDURE

CONTENTS 1 INTRODUCTION 2 POSSIBLE INSTALLATION DIFFICULTIES 3 OUTLINE OF THE ASSESSMENT PROCEDURE 4 PURPOSE OF THE ASSESSMENT PROCEDURE 1 Guide to the Condensing Boiler Installation Assessment Procedure for Dwellings CONTENTS 1 INTRODUCTION 2 POSSIBLE INSTALLATION DIFFICULTIES 3 OUTLINE OF THE ASSESSMENT PROCEDURE 4 PURPOSE OF THE ASSESSMENT

More information

Part L1B & What you need to know to get your building to pass. Mike Andrews DipNDEA, DipDEC, DipOCDEA, DipHI

Part L1B & What you need to know to get your building to pass. Mike Andrews DipNDEA, DipDEC, DipOCDEA, DipHI Part L1B & What you need to know to get your building to pass. Mike Andrews DipNDEA, DipDEC, DipOCDEA, DipHI The Building Regulations Part L1B what they are, how they affect your building design, and what

More information

7 Temple Close Dorchester, Dorset

7 Temple Close Dorchester, Dorset 7 Temple Close Dorchester, Dorset 7 Temple Close, Dorchester, Dorset DT1 2QL A Modern Detached Four Bedroom House within the popular Castle Park residential part of Dorchester, close to Thomas Hardy School

More information

Home Inspection Report

Home Inspection Report 4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 tripleainspections@gmail.com Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:

More information

Does Wall Township require an inspection by the building department on resale of a home?

Does Wall Township require an inspection by the building department on resale of a home? Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,

More information

Fall in love with your heating again. Reduce your heating bills with

Fall in love with your heating again. Reduce your heating bills with Fall in love with your heating again Reduce your heating bills with Worried about your energy bills? We re here to help! With energy prices rising and great pressure on household budgets, it s sensible

More information

Delivering exceptional performance and Ecovalue. Ecocent

Delivering exceptional performance and Ecovalue. Ecocent 1 Delivering exceptional performance and Ecovalue. Ecocent 2 The Ecocent Hot Water System As the cost of providing heating and hot water continues to increase, homes and businesses are seeking out more

More information

Guidance on Householder permitted development rights

Guidance on Householder permitted development rights FORWARD CONTENTS CLOSE Guidance on Householder permitted development rights Circular 1/2012 CONTENTS BACK FORWARD CLOSE 1. INTRODUCTION 04 2. BEFORE STARTING 05 3. MAIN CONCEPTS 07 Principal elevation

More information

Case Study Family Room Renovation 3br family home, Melbourne

Case Study Family Room Renovation 3br family home, Melbourne Family Room Renovation 3br family home, Melbourne In a Nutshell With time and budget constraints we often renovate just one room at a time. This case study looks at a family room renovation where the key

More information

4 Redland Road, Malvern, Worcestershire, WR14 1LY. 165,000 Guide Price. www.platinum-property.co.uk

4 Redland Road, Malvern, Worcestershire, WR14 1LY. 165,000 Guide Price. www.platinum-property.co.uk 4 Redland Road, Malvern, Worcestershire, WR14 1LY TWO BEDROOM DETACHED BUNGALOW in Malvern Link close to amenities. Accommodation comprises Entrance Hall, Living Room, Kitchen/ Diner, Two Bedrooms and

More information

52 Ways To Save. 3. Ask for feedback. Ask about the pros and cons of different elements of your design and how each will affect your budget.

52 Ways To Save. 3. Ask for feedback. Ask about the pros and cons of different elements of your design and how each will affect your budget. 52 Ways To Save As you may know, building a new house can get expensive if you are unaware of ways to keep your costs down. First-time home buyers, along with high-end luxury buyers, all want to know how

More information

Building Control Guidance Note

Building Control Guidance Note Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you

More information