Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Similar documents
Commercial Boiler Systems and Controls

Commercial Gas Water Heaters

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc.

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

G234X-55 Conventional Gas Boiler

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

presents Hydraulic Separation Beyond Primary / Secondary Piping

NAVIEN AMERICA INC FITCH AVENUE

Better Boilers.

GAS CONVERSION PROJECT ˆAn Alternative to Oil

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

Condensing Boiler Efficiency

Commercial Semi-Instantaneous Water Heaters

Boiler Manual. Installation Startup Maintenance Parts WARNING

FILLING AND PURGING THE SYSTEM

Morrison Bros. Co. General Product Specifications

Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs

High efficiency, cast-iron gas boiler

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

TANKLESS DURABILITY Tankless Product Guide

SOLI TANKLESS PRODUCT GUIDE

DESIGNER S HIGH EFFICIENCY GUIDE SYNC COMMERCIAL BOILERS. Up to 98% Thermal Efficiency.

REGULATORS 175/153 Series

Commercial Gas Water Heaters

Principals of Condensing Boiler System Design

High Efficiency Heating

Steam System Best Practices Condensate System Piping

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Mini-HYDRO TM Installation Manual

THERM Tankless Water Heaters. Applications Manual

Vitodens 200, B2HA / B2HB - Product Introduction

Commercial Gas Water Heaters

APG-4R_Layout 1 9/14/11 12:01 PM Page 1 APG-4R XL X F L

Navien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

AIR LINE VALVES AND GAUGES

Installation Operation Maintenance

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

Applications manual. For tankless and point-of-use water heaters

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

PMI-IF-H High Efficiency Gas Heat Units

PART 11: START-UP PROCEDURES FOR THE INSTALLER

ECOCIAT. Domestic hot water heat recovery unit

Nirvana. Cycling Refrigerated Dryers

ASME Packaged Indirect Fired Water Heater

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Installation & Operation Manual Models: STU

Fundamentals of Hydronic Design

RECON WATER HEATER INSTALLATION FORM

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

OTF Oil Fired Pool Heater

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Applications manual. For tankless and point-of-use water heaters

Commercial Gas Water Heater

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

Thermal Expansion and Your Water Heater. Bradford White Explains What it is and How to Protect Yourself and Your Family From it.

HYDROSTATIC TEST PUMPS

SPIDERfire: Delivers high efficiency and real savings for today s businesses

Copper Meter Resetters

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Model CFC ClearFire Condensing Boiler

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

Buderus. Flexible Energy Efficient Solutions. Comfortable. Efficient. Intelligent Heating. GB312 Series Natural Gas Condensing Boiler.

MUELLER FALLING FILM CHILLERS

Buderus. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. G315 G515 G615 Cast Iron Commercial Boilers.

DESIGNER S GUIDE EFFICIENCY+ BOILER

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY 399M COMMERCIAL BOILER

SIOUX HYBRID WATER HEATER

Installation & Operation Manual Models: SIT030 - SIT119

Indirect fired heaters

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Cooling Capacity CFM in. w.c. (125 Pa)

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

Solar Skies Stainless Tank Series Water Heater

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Product and Safety Information... 2,3 Service and Maintenance Munchkin Operation Primary Water

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

Light Duty Commercial Electric Water Heater

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Originators of the Flexible Water Tube design

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Tankless water heaters

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Nordic Heat Pump Product Guide

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Transcription:

Advanced Heating & Hot Water Systems A Trailblazing Energy Star Listed Boiler that Installs like a Mid-Efficiency Boiler with the Performance of a High-Efficiency Product Ultra High Efficiency Energy Star Listed Condensing Boiler HHTP Made In America TP Made In America Up to 96% Efficient 5:1 Turndown Ratio Single Loop Installation

The Pioneer is a trailblazing Energy Star listed boiler that installs like a mid-efficiency boiler with the performance of a high-efficiency product. FEATURES AND BENEFITS High Efficiency Up to 96% Energy Star listed AFUE, this product uses less energy to meet desired heating loads and significantly reduces energy costs. The Alternative to Mid-Efficiency Products With ample thermal mass and no primary/secondary piping required, this unit is a replacement for mid-efficiency units. Hydronic Stabilization Stored hot water, or thermal mass, in the stainless steel tank provides a buffer against cycling during low load conditions. Low Maintenance Design The advanced hybrid cupronickel/stainless steel heat exchanger eliminates scale buildup through rapid thermal expansion / contraction, and its down fire characteristics allow for rapid removal of acidic condensate. Single Loop Installation The heat exchanger, constantly surrounded by water, is protected against flashing due to low flow conditions, eliminating the need for a primary/secondary piping setup. The Pioneer s low pressure drop eliminates the expense of high head boiler circulators.

COMPETITIVE EDGE Pioneer Boiler Atmospheric Cast Iron Boilers Atmospheric Copper Fin Boilers Power Vented Non- Condensing Cast Iron Boilers Condensing Low Mass Boilers Efficiency Up To 96% 85% 85% 87% 90% Modulation YES NO NO NO YES Vent Category IV I I II or IV IV Required Vent Materials PVC or AL29-4C Stainless Steel Type "B" Materials or lined chimneys Type "B" Materials or lined chimneys AL29-4C Stainless Steel PVC or AL29-4C Stainless Steel Controls Modulating On/Off On/Off or Staged On/Off or Staged Modulating Piping Setup Single Loop Single Loop Primary/Secondary Single Loop Primary/Secondary Built in Air/Dirt Separator Thermal Mass for System Stabilization YES NO NO NO NO YES YES NO YES NO Eligible for Federal Tax Credit YES NO NO NO YES The Pioneer Boiler meets or exceeds the competition in all 9 of the categories highlighted in the chart above. The cutting-edge features, technological advancements, ease of serviceability, and energy savings make The Pioneer a superior alternative to mid-efficiency cast iron and copper fin boilers. The figures above are based on averages. Data was collected from various competitor sources. Changing the Course of Hydronics...

A Closer Look At HTP s Pioneer Boiler T&P Relief Port Low Water Cutoff Sensor Hybrid Cupronickel/ Stainless Steel Heat Exchanger Stainless Steel Tank Air/Dirt Separator Lower Temperature Tank Sensor Alternate System Return Drain Port Location Air Intake to PVC Venting UL 636 Exhaust Adaptor to PVC Venting Air Vent Dual Tank Sensor ECO High Temp. Limit High Tank Temp. Sensor State of the Art Control Board Outdoor Reset Cascading Capabilities Easily Removable Cover Modulating Combustion Stainless Steel Burner Negative Regulation Gas Valve Maintenance and Service Made Easy Low maintenance heat exchanger design: 5 diameter combustion tube which connects to 1-1/8 down firing spiral tubes. The Pioneer s combustion and control system can be accessed by removing a light, molded cover. Easy access to control board, display and field connection board without the need for tools. The gas valve/burner assembly is detached by removing 6 simple nuts and one end of the flexible gas line to the valve.

EASE OF INSTALLATION Space Heating Appliance and Buffer Tank In One No Boiler Loop Required Direct Connection to the Primary Heating Loop Low Pressure Drop PVC Venting Material - Easier Installation - Reduced Cost Simplified Retro Fitting for Cast Iron Boiler Replacements Combustion Air: Direct Vent / Room Air Intake PIONEER CENTRAL HEATING ZONE CIRCULATORS with IFC (TYP) RETURN NOTE: RECOMMENDED DRAIN FOR CLEANING EXISTING SYSTEMS BALL VALVE (TYP) AIR VENT RETURN TO SYSTEM SUPPLY MAKE-UP WATER BACKFLOW PREVENTER PRESSURE EXPANSION TANK REDUCING VALVE DRAIN TEMPERATURE AND PRESSURE GAUGE (TYP) T&P VALVE ALTERNATE LOWER RETURN CONFIGURATION NOTE: RECOM MENDED DRAIN FOR CLEANING EXISTING SYSTEMS LP-325-F 07-21-10 Advancing Hydronics Technology...

Pioneer Boiler Dimensions and Specifications SUPPLY D RETURN AIR VENT C L T&P PORT F RETURN PORT SUPPLY PORT B K E G H A DRAIN VALVE J PIONEER DIMENSIONS MODEL # GALLONS A B C D E F G H J K L PHR100-55 PHR130-55 55 23" 53" 6-1/2" 8" 22" 7-1/2" 8" 6" 34" 45" 1-1/4" PHR 160-55 PHR199-55 MODEL # MODULATION RANGE AIR INTAKE/EX HAUST VENT SIZE PHR100-55 33,000-100,000 2" PHR130-55 44,000-130,000 2" PHR 160-55 53,000-160,000 3" PIONEER SPECIFICATIONS SUPPLY/RETURN SIZES AIR VENT PHR199-55 66,000-199,000 3" All standard Pioneers are built to fire on Natural gas. LP conversion kits are included with the product.. GAS CONN SHIPPING WEIGHT. 1-1/4" NPT 1/8" NPT 3/4" 175LBS LP-325-L 07-22-10 STANDARD FEATURES - Modulating Burner - 5:1 Turndown Ratio - Venting Options - Room Air Intake - Concentric - Flexible Vent Pipe - Up to 200 combined ft. - Single Loop Installation - 12 Year Limited Warranty INCLUDED IN THE BOX - Pressure and Temperature Gauge - 30 PSI Temperature and Pressure Relief Valve - Intake PVC Tee w/ Screens - Exhaust PVC Coupling w/ Screens - Installation Manual - Outdoor Sensor OPTIONAL EQUIPMENT - System Sensor - Indirect Tank Sensor - 3, 4, 6 Stainless Steel Outside Termination Vent Kit - 3 PVC Concentric Vent Kit - U.L. 353 Compliant Low Water Cutoff w/ Manual Reset - Alarm System to Monitor Failures - PC Connection Kit - Condensate Neutralizer Pioneer Model Energy Star Listed AFUE PHR-100-55 92.4% PHR-130-55 96.2% PHR-160-55 94.4% PHR-199-55 93.7% www.htproducts.com HTP MKTLIT-16 09/2012 120 Braley Road. East Freetown, MA 02717