DETECTION. Professional. Who s Gas Is It? SENSIT IRED Has the Answer

Similar documents
Propane and Natural Gas Safety

Natural Gas Emergencies

SENSIT PRODUCT GUIDE MUNICIPAL SERVICES

The Basics of Natural Gas

EzFlex Combustible Gas Leak Detector Model EZ40

Natural Gas Information Contents

MATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence

GAS LEAKAGE DETECTION & AUTO ON-OFF GAS SYSTEM

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Gas Detection for Refining. HA University

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

Nonrenewable Natural Gas. Natural Gas Basics. How Was Natural Gas Formed?

PIPELINE EMERGENCIES. Chapter 5 Gas Pipeline Operations. Michael Callan

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

Combustible Gas Leak Detector 720b

BIOMASS: BIOGAS GENERATOR. Curriculum: Biomass Power (organic chemistry, chemical/carbon cycles, plants, energy resources/transformations)

Thermal Mass Flow Meters

Incident Reporting Requirements

Natural Gas and Transportation

THE DETECTION OF GREENHOUSE GASES

N O T E S. Environmental Forensics. Identification of Natural Gas Sources using Geochemical Forensic Tools. Dispute Scenarios

CHAPTER X GAS LEAKAGE CONTROL GUIDELINES FOR PETROLEUM GAS SYSTEMS

Questar Safety Data Sheet

Natural Gas Safety. What You Need to Know

Natural Gas Safety What You Need To Know

ANALYZING ENERGY. Time and Student Grouping Energy Source Analysis and Consequence Wheel: One class period. Grade Levels: 6-12

GREENHOUSE GAS EMISSIONS INVENTORY

S 0417 S T A T E O F R H O D E I S L A N D

This fact sheet provides an overview of options for managing solid

How to Select a Flame Detector

UCLA - Compressed Gas Cylinder Storage and Handling

Biomethane in Vehicles. October 2008

RECON-4 Portable Multi-gas Detector Software Manual

How To Stop A Gas Leak

Manual for Fire Suppression & Methane Detection System

Tomorrow s Fuel, Delivered Today. Company Profile

Renewable Choice Energy

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

THE GAS UTILITIES S AND THE JAPAN GAS ASSOCIATION S EFFORTS TO IMPROVE SAFETY

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Global Warming and Greenhouse Gases Reading Assignment

NSPS Subpart OOOO: Applicability and Compliance Basics

GEORGIA DEPARTMENT OF COMMUNITY AFFAIRS (DCA) STATE CODES ADVISORY COMMITTEE (SCAC) CARBON MONOXIDE DETECTORS FOR SCHOOLS TASK FORCE

Evaluation of portable flue gas analysers for monitoring carbon dioxide in ambient workplace air HSL/2006/42. Project Leader: Peter Walsh.

Guidance for Those Who Use and Store Gas Cylinders

An inventory of hazardous materials used in your workplace will prove useful.

Methane to Markets Oil and Natural Gas Technology Transfer Workshop

Emergency Response Guide

White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen

Alternative fuels. The way forward

ABSTRACT INTRODUCTION

Green Guide for Businesses Strategy: Energy

[]n. Craving energy. Oil and gas formation. Oil and gas formation. Resources: Fossil Fuels. Supplying our energy needs: Source of energy in the US

Fiscal Measurement Natural Gas

READING COMPREHENSION I SIR ISAAC NEWTON

Section Ambulance Service Charge. Effective July 1, 2014, the following bundled ambulance service charges shall apply:

CAT CG132. Series Gas Generator Sets

Appendices. Average Electricity Costs Newfoundland and Labrador

PIPELINE FUNDAMENTALS. texaspipelines.com

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

SAMPLE CHAPTERS UNESCO EOLSS NATURAL GAS PROCESSING. H. K. Abdel-Aal National Research Center (NRC), Cairo, Egypt

Renewable Energy and Energy Efficiency Portfolio Standard (REPS).

Municipal Solid Waste (MSW) A Source of Biomethane Transport Fuel for New Jersey

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

A Green Idea. Reclaiming Urban Wood Waste And Urban Forest Debris. For Fuel/Combustion & Renewable Energy

The California Environmental Protection Agency works to restore, protect,

Biomass Renewable Energy from Plants and Animals

Solid Waste: Opportunities for Greenhouse Gas Emission Reduction in Sonoma County. Community Climate Action Plan

Residential & Commercial Sectors Overview CLIMATE

Compressed Gas Cylinder Storage and Handling Guide

Biogas. Biology Teams of 2 or 3. Grade LEARNING OUTCOMES DESCRIPTION MATERIALS READINESS ACTIVITIES. Science

OPTIONS FOR COMMERCIAL GAS DEVELOPMENT OF MARGINAL FIELDS

Balancing chemical reaction equations (stoichiometry)

Sounding the Call Carbon Monoxide What You Need to Know

FORD COMMERCIAL TRUCK ALT FUEL CHOICES AT A GLANCE

Chapter 4. Chemical Energy

ICC CODE CORNER 2012 IFC Code & Commentary

Automotive Air Quality Sensors: industrial innovations to protect people s health

Australian Pipeline Industry Association

INFORMATION BULLETIN Bulletin No Bureau of Fire Prevention Date: June 10, 2005 Revised: March 8, 2007

Can Gases Act Like a Greenhouse?

The Ambient Air Monitoring System

SEATTLE STEAM COMPANY FREQUENTLY ASKED QUESTIONS

Regulator Performance Data

A Job Safety Execution Plan is required. mixtures of the above called, natural gas liquids (NGL's) refined products and their components

Characterization of Greenhouse Gas Emissions Involved in Oil and Gas Exploration and Production Operations

Boiler Tune-up Guide

Renewable Energy and Energy Efficiency Portfolio Standard in North Carolina. Sam Watson, Senior Staff Attorney North Carolina Utilities Commission

Wood Pellet Stove 101

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Module 7 Forms of energy generation

Transcription:

Issue 1 August 1, 2015 A publication of SENSIT Technologies DETECTION Professional Who s Gas Is It? SENSIT IRED Has the Answer

President s Message I am very excited to introduce the inaugural edition of Detection Professional. We will use this forum to share product news, case studies from the field, customer and employee profiles, product usage tips, and other information that we hope you ll find useful. This first edition (sure to be a collector s item) features an article about our newest product, the SENSIT IRED. You ll also find a case study about an incident investigation and a Frequently Asked Questions segment list from our Service Department. J. Scott Kleppe President and Chief Executive Officer 2015 has been a very busy year so far for Sensit Technologies. Representatives from gas utilities around the globe visited us at the World Gas Conference in Paris in June where we featured the Ultra-Trac APL, Sensit VMD, as well as our numerous ATEX approved products for sale in the European Union. In May, we were proud to unveil our leak truck featuring the SENSIT VMD at the American Gas Association Conference in Grapevine, Texas. Also at this conference, I presented a white paper that described our collaboration with the Gas Technology Institute to create the SENSIT IRED (infrared ethane detector) utilizing GTI s Infrared Absorption Spectroscopy technology. We welcome your ideas to help create a well-balanced and useful publication. Feel free to forward your ideas, thoughts, and contributions to marketing@gasleaksensors.com Best regards, J. Scott Kleppe President and Chief Executive Officer 3

Feature Article Whose Gas is it? When a utility worker or emergency responder is called to a house because of a gas smell, one of the things at the forefront of their mind is finding the source. Methane is the primary component in natural gas. When methane is present, it is critical to determine if it is naturally occurring (like sewer gas), or if it is from a natural gas pipeline. Without an immediate and accurate determination of the source, workers often shut down affected portions of the system while the gas is analysed a costly proposition. The Problem: Methane is combustible and presents a hazard to the environment and people. Oil and gas explorers, producers, and distributors strive to detect natural gas leaks. Recently, a utility company found a Class 1 gas reading during a gas leak survey, but they had no way of determining onsite if the methane was from their utility system. They collected a sample of the gas and sent it to a lab for analysis. Two days later they got their answer, but in the interim they were forced to monitor the Until now, there hasn t been a portable, cost effective and accurate way of determining if a methane source is from a gas line or if it is naturally occurring. SENSIT Technologies recently introduced the revolutionary IRED Infrared Ethane Detector. What is methane? Methane is the primary constituent of natural gas. It is also the second most widespread potent greenhouse gas in the United States, behind carbon dioxide. Even though methane does not stay in the atmosphere as long as CO2, it is 120 times more potent than carbon dioxide. Where does methane come from? While one of the primary sources of methane is fossil fuels like natural gas, other anthropogenic sources include landfills, sewer gas, waste, ruminants, rice cultivation, and burning biomass. There are also numerous naturally occurring sources such as wetlands, termites, oceans, geological sources, wild animals, and wildfires. leak around-the-clock, which was very expensive. As it turned out, the gas was not theirs yet they shouldered the expense of monitoring it. Situations like these often occur. While leak detection technologies readily exist to detect methane, it has been a challenge for companies to offer detection equipment that is portable, costeffective, and able to discriminate between pipeline natural gas versus other methane sources. 4 DETECTION PROFESSIONAL Issue 1

The Solution: Ethane as the Fingerprint Natural gas typically consists of approximately 80-95% methane (CH4) with the balance coming from other gases, including butane (C4H10), propane (C3H8) and ethane (C2H6). This combination and the percentage of each of these gases makes up a fingerprint that can determine if the methane s source is natural gas from a particular gas utility s system or from a natural gas production site or from biogas or sewer gas. Ethane is only present in natural gas. It is not present in methane produced as the result of organic decomposition (swamp gas, sewer gas, compost, etc.). The bottom line is that if ethane is present at all, the methane source is pipeline grade natural gas. SENSIT Technologies IRED Ethane Detector In a development project sponsored by the Gas Technology Institute and SENSIT Technologies, the leading manufacturer of gas leak detection equipment, the IRED Ethane Detector was recently released. SENSIT s IRED detects and accurately measures only ethane allowing the user to quickly determine if the methane in the area is coming from the pipeline versus some other source. Accurate results are immediately available to the user, saving time and expense versus traditional methods of gas analysis. Additionally, because ethane concentrations can differ between gas distribution systems and, for example, production sites, the IRED can quickly and reliably identify the source. The IRED uses a technology called infrared absorption spectroscopy to detect ethane in a sample of methane. It can detect as little as 250 parts per billion ethane in a sample as small as 50 parts per million methane. The fast results allow the user to make quick and accurate judgements to make the area safe and determine the actual source of the leak. IRED is portable (6 pounds), and features simple 3-button operation, a user-friendly interface, data recording, and a rechargeable Lithium ion Battery. The instrument comes with Bluetooth communication and is available with an optional GPS data recording and mapping feature. 5

Case Study Incident Investigation Non-Standard Combustible Found Using SENSIT GOLD G2 The Client A municipally owned gas utility system in North Carolina serving more than 30,000 residential customers. The Challenge The gas utility needed to determine if an explosion and resulting fire at a residence within its jurisdiction was caused by a natural gas leak. The explosion blew the garage doors off of the home and the gas line going to the water heater was on fire. The structure did not appear to have damage at the roof line, which is more typical of a natural gas explosion because of its lighter than air attribute. SENSIT Solution Utility workers used the SENSIT Gold G2 to survey the area in and around the structure. The most significant readings were found around the garage foundation. The SENSIT display read NSC, the abbreviation for Non-Standard Combustible. This provided a critical piece of evidence to the investigation. The NSC reading told the utility worker that while there was a combustible gas present, it was likely a heavier hydrocarbon than natural gas. Results & Impact The NSC reading alerted the utility workers to the possibility of another ignition source for the explosion and fire. Further investigation revealed an overturned can and a trail of gasoline, most likely tipped by the homeowner s dog. The gasoline ran into the foundation area and the fumes eventually built to an explosive level. The SENSIT G2 s ability to the NSC reading helped the utility prove that natural gas was not the source of the explosion and fire, mitigating their liability and saving them untold costs. 6 DETECTION PROFESSIONAL Issue 1

Frequently Asked Questions Service Department Q: My instrument (SENSIT HXG-3P and SENSIT Gold Series including G2) displays, LEL Fail. Has the sensor failed? A: LEL Fail may indicate a failed sensor. However, LEL Fail often means that the sensor was removed and then incorrectly re-installed. Correct orientation of the tab is essential. See the picture for proper installation. Tab on the Sensor must align with the mark on the sensor board. Q: My instrument (SENSIT G2, Gold CGI, Trak-It III, and Trak-It IIIa) displays NSC or NSR. What does this mean? A: NSR or NSC are displayed when the instrument encounters a gas to which it is not calibrated. NSR (nonstandard response) and NSC (non-standard combustible) readings may occur on the G2 and Trak-It IIIa instruments. The Gold CGI and Trak-It III are only capable of NSR readings. If the G2 or Trak-It IIIa is set to Natural Gas, NSR indicates the presence of a non-combustible gas (such as CO2 or pure nitrogen). If set to Propane, an NSR reading indicates the presence of a gas lighter than air that is most likely not combustible (such as helium). If the G2 or Trak-It IIIa is set to Natural Gas, an NSC reading indicates the presence of a gas heavier than air (such as Propane or Gasoline). If set to Propane, NSC indicates the presence of a gas lighter than air like methane, hydrogen or natural gas. For Gold CGI s and the Trak-It III NSR indicates a non-standard reading of a gas which may or may not be combustible. Q: How do I calibrate my instrument? A: Refer to the user manual included in the instrument s case for calibration instructions. Instructions are also available at www.gasleaksensors.com/resources. Additionally, our service technicians can provide support via telephone at 219-465-2700. Q: My SENSIT Gold (CGI or G2) will not calibrate or display Flow Block. A: Check for cracks in the sensor cap and replace the cap if cracked or damaged. Also, ensure that the senor cap is seated correctly in the gland with one O-ring. Replace O-ring if damaged. A spare sensor cap and O-rings are supplied with each instrument. Q: My SENSIT Gold (CGI/G2) shows O2 fail. What does that mean? A: If the instruments displays O2 fail at the work display but not during auto-zero, an O2 test needs to be performed. If the instrument displays O2 fail at both auto-zero and at the work display, the sensor needs to be replaced. Call the SENSIT service department before returning your instrument for repair, service, or calibration. Many issues can be resolved via telephone. If the instrument needs to be returned for service, our service techs will provide a form (via email, website or fax) that must be completed prior to return. The form requests specific information regarding the problem and complete contact information. Please return the instrument in the case provided to provide adequate protection during shipping. SENSIT Technologies 851 Transport Drive Valparaiso, IN 46383 Attn: Service Dept. 7

percent gas / percent lel conversion chart % GAS METHANE / NATURAL GAS 0 1 2 3 4 5.5 1.5 2.5 3.5 4.5 % LEL 0 10 20 30 40 50 60 70 80 90 100 % GAS PROPANE 0.44.88 1.32 1.76 2.2.22.66 1.1 1.54 1.98 % LEL 0 10 20 30 40 50 60 70 80 90 100 2015 Trade Show Dates Aug. 3-6 Appalachian Short Course Moon Township, PA Aug. 12-14 MEA Operations Conference Rochester, MN Sept. 23-24 CH4 Connections The Woodlands, TX