MapIT G2 Infrastructure Management



Similar documents
MapIT. G2 Infrastructure Management. Section Contents. MapIT G2 INFRASTRUCTURE MANAGEMENT 8.0

INTELLIGENT INFRASTRUCTURE MANAGEMENT

SIEMON Data Center Solutions.

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

SMARTen 24 UTP Patch Panels

SMARTen 24 STP Patch Panels

HARTING Ethernet Cabling 8-poles Overview

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

AMP NETCONNECT Data Center Cabling Solutions

AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM

ADC-APC Integrated Cisco Data Center Solutions

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

How To Design A Data Center Network

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

Category 6 UTP - Cabling System

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

ADC Structured Cabling Solutions

C6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A

Intelligent Infrastructure

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

3M Telecommunications. Solutions for Networks. Intelligent Management System. Technology built for business

DigiPoS Store Solutions: Retail Blade

InstaPATCH Cu Cabling Solutions for Data Centers

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

Standard Buccaneer - Ethernet

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

SignalTEK II. Save money by using a single multifunction device in place of separate copper, fiber and Power over Ethernet (PoE) testers

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

AMPTRAC CONNECTIVITY MANAGEMENT SYSTEM

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

HARTING Ethernet Cabling 4-poles Overview

Cable Assembly Solutions at the Speed of Light

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Accelerating Light. Copper Cabling Solutions. Category 6A

How To Make A Data Center More Efficient

GEU Port Gigabit Switch

Developing the Green Data Centre

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

The High Cost of a Low-Cost Cable Certification Tester

Quick Installation Guide 8-Port 10/100/1000Mbps Green Switch

Data Centre & Enterprise Solutions. RapidNet

Arista and Leviton Technology in the Data Center

Gigabit Switching Ethernet Media Converters - Product User Guide

Tools for Building a Better Network

How To Power A Bladecenter H Servers

Copper Patch Cords. Impact On Network Performance and Reliability

400 Series - Mini USB Buccaneer

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

Developing the Green Data Center

PHYSICAL INFRASTRUCTURE MANAGEMENT SYSTEM

Network Design. Yiannos Mylonas

Physical Layer Management

PE6108/PE6208/PE8108/PE8208

HARTING mcon 1000 Introduction and features

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Zone Distribution in the Data Center

Power distribution in data centres

Managing Physical Security Risk in Physical Layer Infrastructure Solutions

10GBASE-T SFP+ Transceiver Module: Get the most out of your Cat 6a Cabling

Cabcon. Data Centre Solutions. an acal group company UK +44 (0) IRE (00353)

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Innovative Connectivity Solution for Maximum Performance and Security

8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual

Hand-held thermometer Model CTH7000

CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW. Dell PowerEdge M-Series Blade Servers

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

Power & Environmental Monitoring

PROFINET Diagnostics Software and Tools

TIA-942 Data Centre Standards Overview WHITE PAPER

How to Determine the Right Fiber Optic Network Backup Switch For Your Application

6000 Series Buccaneer

CATEGORY 8: UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE

SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays

Corning Cable Systems Optical Cabling Solutions for Brocade

Cable management for rack-mounted systems

HARTING Ethernet Cabling 4-poles Overview

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

POWER OVER ETHERNET SYSTEMS

How To Set Up A Minipatch System For A Small Office Or Home Use

8-Port PoE Network Switch

THE MOLEX REAL TIME PATCHING SYSTEM. The only connectivity management solution you can trust for the long term.

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers

Copper Pre-terminated Assemblies

Panduit 28 AWG Patch Cords Installation Guideline

HP ProCurve High-Speed Transceivers Installation Guide

Nearly 60 Years of Infrastructure Leadership

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Data Center Topology Guide

Data Center Network Infrastructure The Smart Choice For Your Data Center

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Terminal and Dimension

Transcription:

MapIT G2 Infrastructure Management Introducing MapIT G2, a complete upgrade of Siemon s popular MapIT intelligent infrastructure management (IIM) solution. MapIT G2 integrates a powerful combination of innovative Smart Patch Panels, user-friendly Master Control Panels and MapIT IM software to provide real-time tracking and reporting of network-wide physical layer activity. This benchmark IIM system offers truly unparalleled capacity to manage complex networks. 28% of downtime in data centres is due to change and human error 1 Every hour of downtime costs $100K 1 49% of Fortune 1000 IT managers listed reducing cost as a top priority 2 1-2007 Symantec Survey 2 - mvalent 2008 Market Survey SECTION CONTENTS MapIT G2 Control Panels..................... 8.1 8.2 Optional Accessories..............................8.2 MapIT G2 Copper Systems.................... 8.3 8.4 MapIT G2 Fibre Systems..................... 8.5 8.6 www.siemon.com 8.0

MapIT G2 Master and Distribution Control Panels The MapIT G2 Master Control Panel (MCP) collects all network infrastructure data provided by the Smart Patch Panels and Fibre Enclosures, monitoring up to 2880 ports in just 1 rack space (1U). The MCP and DCP feature an integrated LCD display and keypad, which provides technicians with access to critical network architecture and diagnostic information. By providing this interface locally within the patching zone, the MapIT G2 virtually eliminates the need for technicians to carry PDAs or directly access the MapIT software server. This interface allows full end-to-end graphic circuit traces for any channel in the system and can perform extensive diagnostic tasks on any component or port. Superior Density Low profile 1U design increases density and reduces usage of costly rack and cabinet space in data centres and telecommunication rooms Scalable MCP can monitor as few as 48 ports and up to 65,000 ports to cost effectively monitor small remote offices, large data centres or office/campus environments Simple, Multi-Functional User Interface Large graphic LCD and keypad enables technicians to view circuit traces, patch cord traces, perform diagnostics and more, improving efficiency in maintenance and MAC work Ease of Implementation Simple design and straightforward implementation and setup reduces the time and technician skill required to design and install the system Reduced Power Consumption 75% lower power consumption compared to traditional intelligent patching systems for monitoring equipment. This power saving decreases operating expenses and provides a more environmentally friendly solution High Resiliency Redundant power and Ethernet connectivity provides increased reliability, reduces downtime Excellent Thermal Efficiency The MCP and DCP s combination of ultra low heat generation and a low profile design limits airflow impedance, helping to maximise cooling efficiency in data centre environments MCP Graphic LCD Redundant power and Ethernet Field-terminated control connections (RJ-45 Front or S310 Rear) 8.1 www.siemon.com

MapIT G2 Master and Distribution Control Panels M-MCP.................... MapIT Master Control Panel, 1U, black* M-DCP.................... MapIT Distribution Control Panel, 1U, black* *Includes (1) probe pen, rear cable manager, cable ties, S310 termination caps and ground lug Note: 1U = 44.5mm Optional Accessories Power Supply M-PS...................... 6v, 3amp power supply for MCP or DCP Replacement Probe Pen M-PEN.................... MapIT probe pen, 7.62m cord Category 5e Shielded Cable for Control Connections 9A5M4-E2.................. PVC (CM, IEC 60332-1), Grey jacket, 305m Reel-in-Box 9A5L4-E2.................. LS0H (IEC 60332-1), Violet jacket, 305m Reel-in-Box PS8-8 Shielded RJ-45 Plugs PS-8-8..................... 8-position shielded modular plug with 8 contacts (compatible with Siemon PT-908 and Tyco crimp tools) 110 Patch Plugs S110P4.................... 4-pair, field-terminated S110 patch plug (coloured icons not included) LockIT RJ-45 Outlet Lock LL-05...................... LockIT Outlet Lock, bag of 10, includes 1 LockIT Universal Key LL-LC-05................... LockIT LC Adapter Lock, bag of 10, includes LockIT Universal Key LKEY-05................... LockIT Universal Key, bag of 10 www.siemon.com 8.2

MapIT G2 Copper Systems MapIT G2 Smart Patch Panels The MapIT G2 Smart Patch Panel (SPP) is an industry first in intelligent infrastructure management. The panel features on-panel intelligence and a combination of LEDs and a backlit graphic LCD to guide technicians. The LCD can be used to display patch cord trace and diagnostic information. It can also be used to troubleshoot network issues, which can drastically reduce downtime and increase productivity. Since it is actively connected to your database, you could even use it as a virtual label, dynamically displaying panel and port information directly from the MapIT database. On Panel Intelligence Port monitoring capability is built into each patch panel - Increases density and reduces cost. High Reliability Redundant power and communications to each smart patch panel. Self Diagnostics If a SPP is disconnected from the system, the MCP will report it to the MapIT software, which can trigger an alert to an IT manager or technician to fix the problem. Scalable Equally cost effective solution for monitoring small remote offices, large data centers or office/campus environments. Patch Panels M-SPP-K24E............... MapIT 24-port modular Smart Patch Panel, accepts Siemon UTP or shielded keystone outlets (sold separately) Includes (4) S110 termination caps, 24 cable ties and panel ground lug 24 MapIT IM software port licenses included with each panel Siemon Keystone Outlets Z6A-SK01.................. Keystone shielded Z-MAX 6A outlet, black*, T568A/B Z6A-K01................... Keystone UTP Z-MAX 6A outlet, black*, T568A/B Z6-K01.................... Keystone UTP Z-MAX 6 outlet, black*, T568A/B MX6-K01................... Keystone UTP MAX 6 outlet, black*, T568A/B (not shown) *Other colours available Keystone Z-MAX Shielded Outlet Keystone Z-MAX UTP Outlet MapIT IM Software This robust program manages, monitors and documents your network infrastructure through Siemon s MapIT G2 connectivity. For more information on MapIT IM software, including features, capabilities and system requirements, please contact your local Siemon representative, or visit www.siemon.com. 8.3 www.siemon.com

MapIT G2 Copper Systems MapIT G2 Patch Cords These advanced cords also feature a 9th wire and sensor pin contained in a robust over-moulded boot. This embedded sensor technology enables tracking of connections between Smart Patch Panel ports. Supports Siemon s High-Performance Systems Category 6A shielded, category 6A UTP and category 6 UTP Reliable Integrated Sensor Connections Sensor pins feature 50 microinches gold plating for long-term contact reliability and resistance to corrosion Simple Testing Features Sensor pin is accessible at the rear of the boot for test and mapping purposes Robust Strain Relief Over-moulded boots provide plug to cable strain relief and retention of sensor pin. 100% transmission testing ensures component and channel performance M-10GMCS-(XX)M(XX)L...... MapIT G2 Category 6A shielded, double-ended, stranded modular cord, colour-matching boot, T568A/B, LS0H 01 = 1 m 02 = 2 m 03 = 3 m 05 = 5 m Jacket Colour 02 = White 04 = Grey 06 = Blue M-10GMC-(XX)-(XX).......... MapIT G2 Category 6A UTP, double-ended, stranded modular cord, colour-matching boot, T568A/B, CMG M-MC6-(XX)-(XX)............ MapIT G2 Category 6 UTP, double-ended, stranded modular cord, colour-matching boot, T568A/B, CMG Jacket Colour 03 = 0.91 m 05 = 1.52 m 07 = 2.13 m 10 = 3.05 m 15 = 4.57 m 20 = 6.10 m 02 = White 04 = Grey 06 = Blue 03 = 0.91 m 05 = 1.52 m 07 = 2.13 m 10 = 3.05 m 15 = 4.57 m 20 = 6.10 m Jacket Colour 02 = White 04 = Grey 06 = Blue www.siemon.com 8.4

MapIT G2 Fibre Systems MapIT G2 Smart Fibre Enclosures The MapIT G2 Smart Fibre Enclosure (SFE) combines on-panel intelligence with robust connectivity and fibre management features for a best in-class intelligent fibre patching solution. An on-board LCD can be used to display patch cord traces and connectivity diagnostic information as well as troubleshoot network issues, which can reduce downtime and increase productivity by remotely guiding onsite technicians. On Panel Intelligence Port monitoring capability is built into each SFE - Increases density and reduces cost. High Reliability Redundant power and communications to SFE s. Self Diagnostics If an SFE is disconnected from the system, the MCP will report it to the MapIT software, which can trigger an alert to an IT manager or technician to fix the problem. Scalable Equally cost effective solution for monitoring small remote offices, large data centres or office/campus environments. Simple Installation Easy to understand and configure with no need to manually map or test each port - reduces the time required to design and install the system. MapIT G2 Smart Fibre Enclosure M-SFE-LC48-01............. MapIT G2 LC 48-fibre Smart Fibre Enclosure, 1U black, multimode and singlemode cable compatible. Cable ties, ground lug, fibre management clips, label holder and printable labels included 24 MapIT IM software port licenses included with each panel Note: 1U = 44.5mm 8.5 www.siemon.com

MapIT G2 Fibre Systems MapIT G2 XGLO Jumpers XGLO MapIT G2 jumpers are built to be the best. These assemblies are constructed with premium fibre that meets IEEE, IEC and TIA specifications for 10 Gigabit Ethernet serial transmission. These advanced cords feature patented MapIT sensor technology gold-plated sensor pins retained in robust moulded connector clips. These jumpers enable tracking of port connections between MapIT G2 fibre enclosures and LAN equipment. XGLO Laser Bandwidth Optimised Cable Reduces impurities in the core of fibre, ensuring robust 10 Gigabit Ethernet transmission Reliable Integrated Sensor Connections 1 sensor pin and copper wire per each duplex connector tracks connectivity status High Quality, High Performance Connectors Jumpers exceed TIA and ISO/IEC requirements for aging, exposure to humidity, temperature extremes, impact, vibration, coupling strength, and cable resistance to stress and strain MapIT G2 XGLO Multimode Duplex Jumpers: M-J2-LCLC5L-(XX)........... LC-LC duplex jumper, MapIT G2 XGLO 50/125 laser optimised multimode fibre, aqua jacket MapIT G2 XGLO Singlemode Duplex Jumpers: M-J2-LCULCUL-(XX)......... LC-LC duplex jumper, MapIT G2 XGLO singlemode fibre, yellow jacket 01 = 1 m 03 = 3 m 05 = 5 m 01 = 1 m 03 = 3 m 05 = 5 m www.siemon.com 8.6