inlab SW 15 SOFTWARE FEATURES



Similar documents
CAD/CAM MATERIAL. ALL FROM ONE SOURCE.

páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí

páêçå~=aéåí~ä=`^al`^j=póëíéã qá_~ëé

páêçå~=aéåí~ä=`^al`^j=póëíéã áåi~ä=pa

New features DWOS 3.2

sets for several machines:

A complete system geared to your success.

CAD/CAM. Solutions flexible, economical, future-proof

DWOS Lava Edition 5.0 new features

Aesthetics meets CAD/CAM in the dental surgery

PRECISION, RELIABILITY, SIMPLICITY. simeda. customized. & solutions. Digital performance

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

Procedures & Products. NobelEsthetics

Implant Parts. A Radford Heath Guide 1

CEREC MUCH MORE THAN RESTORATIONS.

Simpl Implant Abutments with Atlantis CAD CAM Technology

DS6000. Advanced Dental Scanner & CAD Software. Crowns, Bridges Wax-ups Implant Bridges and Bars High Accuracy Scan & Design

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

Tizian TM Creativ RT. Abutment Designer. for the CAD-software version Instruction Manual

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

Abutment Solutions For customized implant restorations fabricated with CEREC and inlab. Digital all around.

Dental System. Product Catalog

Current All-Ceramic Systems

CEREC inlab the multifunctional CAD/CAM system for modern dental restorations.

Summary. DWOS New features. Version 1.2. May 08, Summary 1. Latest Additions 3. Orthodontic Archiving 3

Seeing CAD/CAM in a new light.

Regular C/X Prosthetics. Prosthetics

More than a fixed rehabilitation.

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

Implant Bar Overdenture Utilizing Locator Attachments

Abutment fracture in a bridge supported by natural teeth and implants

Projecting a new smile from a facial photograph:

ATLANTIS abutments as individual as your patients

procedures & products NOBELESTHETICS including Procera

CAD/CAM Anterior and Posterior Implant Restorations: Ceramics, Abutments and Design

Implant solutions. 3M True Definition Scanner. Precise. implant impressions. with incredible speed

Choosing the right type of abutment

digital dentistry solutions

Optimet 3D Dental Multi-Facet Scanner Attainable Accuracy for Dental Application Cases

What s new in Dental System 2013 WHAT S NEW IN DENTAL SYSTEM 2013

páêçå~=aéåí~ä=`^al`^j=póëíéã `bob`=pt pçñíï~êé=séêëáçå=qkp

About DENTSPLY Implants

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Implants in your Laboratory: Abutment Design

Digital impression solutions. 3M True Definition Scanner. Precise. impressions. in a jiffy

WHAT S NEW IN DENTAL SYSTEM 2015

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Milled Bar Overdentures-Protocol and Procedures

State-of-the-art for your prostheses

Procedures & Products Powered by Procera. All-on-4

IPS e.max CAD C16. Larger Size Block Low translucency Shades: A1, A2, A3, A3.5, B1, B2, C1, C2, D2, BL2 Indicated for single unit restorations

Content GENERAL INFO PRODUCT LIST SCREW SELECTION GUIDE PRODUCT TECH INFO. tech info. info ABOUT US & PRODUCTS 4 INTERNAL HEX UNIVERSAL TRILOBE

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

Renaissance of One-Piece Implants

CEREC. Made to inspire.

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

Zfx & Zimmer Dental. Joining together for high-end dental prostheses

TRIOS Digital Impression Solution

Restorative Guidelines

Press Abutment Solutions

INSPIRED BY NATURE: CHRISTIAN FERRARI FULL FUNCTIONAL AND ESTHETIC MINIMALINVASIV RESTORATION USING IPS E.MAX CERAMICS

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

Choose What Feels Right. Bridge vs. Dental Implant

FABRICATING CUSTOM ABUTMENTS

Laboratory Designed Abutment. Optimization By Design

CAD/CAM. Brain CAM V3. Instructions for Use

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

Standard Internal Hex

MEDICAL TECHNOLOGY IN IMPRESSIVE 3D

IMPLANT SYSTEM BRIDGE RESTORATIONS WITH THE CAMLOG CROWN AND. a perfect fit

WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

Enter into the world of unprecedented accuracy! IScan D104 Series

CAD/CAM Block Overview Block-Übersicht

Crown and Bridge Restorations. Straumann synocta Prosthetic System

Precise. Powerful. Pure.

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck

NARROW DIAMETER implant

Implant systems Systematically perfect

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

all digital all options The right milling option High precision and productivity

How To Use A Cresco

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

BICON DENTAL IMPLANTS

How to Achieve Shade Harmony With Different Restorations

platform shifting Nobel Biocare is shifting gingival beauty to the next level

Implant Abutments and Crowns on your CEREC. Welcome

páêçå~=aéåí~ä=`^al`^j=póëíéã `bob`=dìáçé

CEREC. Made to inspire. NEW. Now with CEREC Omnicam. CAD/CAM for the dental practice

TEPZZ 69 _ZA T EP A2 (19) (11) EP A2. (12) EUROPEAN PATENT APPLICATION published in accordance with Art.

Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw

Titanium Base for CAD/CAM For single-tooth and bridge solutions

your talent. our technology. the perfect fit.

3 shape. Dental System by. User Manual Version Copyright Shape A/S. All rights reserved

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Multi-unit abutment bar overdenture

Transcription:

inlab SW 15 SOFTWARE FEATURES This overview outlines the indications, tools, and materials according to the respective software versions starting with inlab SW 15.0. The respective changes to the previous version are listed. OCTOBER 2015

inlab SW 15 SOFTWARE FEATURES 02 inlab SW 15.0 OCTOBER 2015; CHANGES WITH RESPECT TO inlab SW 4.3 GENERAL NEW INDICATIONS The following indications can be handled starting with inlab SW 15.0: JAW-ORIENTED BIOGENERIC SETTING Starting with this version, the entire scanned jaw is used as the basis for the restoration proposals. Especially with large jobs, this results in settings that are harmonious and appropriate to the individual situation. In addition to the biogeneric setting, the user also has the option of using tooth libraries for the initial proposal. PARTIAL REMOVABLE DENTURE Partials can be designed with inlab SW 15.0 and the corresponding inlab Partial Framework plug-in. The scan is done in the inlab software and subsequently sent to the plug-in. The elements of the partial are then designed there. SCREW-RETAINED BRIDGES AND BARS With inlab SW 15.0, screw-retained bridges and bars can be designed on multi-unit abutments by Medentika and nt-trading. Scanning of the implant positions requires ineos X5. In addition, special scan bodies (inpost) were developed to acquire the implant position. A separate gingiva element can also be created for the design. The jobs can then be imported in the inlab CAM software and milled in an inlab MC X5 unit. CEREC GUIDE 2 (SURGICAL GUIDE) Surgical guides can be designed in inlab 15.0 in conjunction with the Galileos implant software. If the surgical guide is milled on an inlab MC X5 unit, it can extend over the entire jaw and include several drill holes. NEW LICENSING SYSTEM The inlab software is divided into modules that can be activated by a license. inlab SW CAI LICENSE This license includes the scanner and allows the models or impressions to be scanned and the data to be saved in the inlab data format or *.stl. inlab SW 15.0 BASIC MODULE Inlays, onlays, veneers, crowns, bridges, copings, bridge frameworks, multilayer restorations, models All design tools, virtual articulator, Smile Design Sirona Connect access NEW: J.O.B.S (jaw-oriented biogeneric setting) NEW: Tooth libraries NEW: Virtual seating NEW: Gingiva element inlab SW 15.0 IMPLANTOLOGY MODULE (OPTIONAL) Custom abutments and screw-retained crowns NEW: Screw-retained bridges and bars on a multi-unit abutment NEW: Surgical guide OPEN GALILEOS implant interface for integrated implantology

inlab SW 15 SOFTWARE FEATURES 03 inlab SW 15.0 REMOVABLES MODULE (OPTIONAL) Telescopes, bars, attachments NEW: Partial removable dentures inlab SW 15.0 INTERFACE MODULE (OPTIONAL) NEW: STL import of scan data (extraoral and intraoral scanners) STL export of inlab restoration data STL export of Sirona Connect intraoral scan data STL export of model design data inlab SW CAM LICENSE For operation of the inlab CAM software and the manufacturing machines (inlab MC XL and inlab MC X5) controlled with it. NEW OPERATING CONCEPT Several sidepanels can be opened simultaneously and positioned as desired on the screen. Using two monitors also allows the sidepanels to be moved to the second monitor. The restorations are active as soon as the mouse is moved over them. The step menu no longer includes mandatory steps, so each phase is gone through one step at a time. OK/Cancel is no longer included in the steps; changes are applied by moving to the next step. INSTALLATION REQUIREMENTS inlab 4 PC HW v1.0.1 or higher Recommended monitor resolution 1980 x 1080 SUPPORTED FILE FORMATS *.lab *.dxd *.cdt Import This format is supported if the source is an inlab 3D v3.8x. Only scan data (no images or restorations) can be imported. *.3si / *.3se These formats can be imported or exported if there is an interface module license (successor to OPEN 3Shape license). *.ssi This format can be exported if there is an OPEN GALILEOS implant license (integrated in the implantology module). *.stl (import/export) Scan data can be imported in this format. Scan data can be exported in this format. Model data (designed models) or restoration data can be exported in this format. Intraoral scan data (CEREC AC) can be exported in this format. The interface module license is required to export or import *.stl data. *.cam This format can be exported for processing the restorations in the inlab CAM software. INTERFACES See supported formats CONFIGURATION Configurable material selection Manufacturers, materials, and block sizes can be activated or deactivated. Parameter profiles Parameter profiles for materials, dentists, or machines can be created for each indication. These profiles can be selected by mouse click during the design process. Generic machine Non-Sirona manufacturing machines that can be selected for the design can be set up in the software. The number of axes, the smallest milling radius, and the milling geometry can be selected. NEW GROUPING FUNCTIONS VIA KEYBOARD SHORTCUTS Starting with this version, restorations can be grouped using the familiar Windows shortcuts SHIFT+click or CRTL+click. Administration phase

inlab SW 15 SOFTWARE FEATURES 04 ADMINISTRATION PHASE ORDER LIST The order list is separated into columns starting from the left with the dentist, order information, and case data with a preview window of the scanned models on the right. TYPES OF RESTORATIONS AND DESIGN TECHNIQUES The following restorations and design techniques can be selected for individual and bridge restorations: TYPES OF RESTORATIONS Inlays, onlays, crowns, veneers Crown copings Bridge frameworks Implant* (for TiBase abutments, screw-retained crowns, bridges, and bars on multi-unit abutments by Medentika and nt-trading) Telescopes Attachments Bars Models Partial removable dentures DESIGN TECHNIQUES Biogeneric individual, biogeneric copy, biogeneric reference (depending on the restoration) Biogeneric individual, biogeneric copy, framework, reduced Biogeneric individual, biogeneric copy, framework Biogeneric individual, biogeneric copy, biogeneric reference; multilayer Crowns Attachments Cylindrical, square, Dolder, Hader Model inlab Partial Framework plug-in * Not all of the design techniques are available for all indications. NEW DESIGN ELEMENT GINGIVA The design element gingiva is available for designing screw-retained bridges and bars. This also allows bridges to be designed with a separate gingival element.

inlab SW 15 SOFTWARE FEATURES 05 MATERIALS The following materials can be selected in the version for restorations. Depending on the type of machine, not all materials are always available: SIRONA VITA IVOCLAR VIVADENT CEREC Blocs CEREC Blocs C CEREC Blocs PC CEREC Blocs C PC CEREC Blocs C In incoris ZI incoris TZI incoris TZI C incoris CC incoris CCB incoris PMMA incoris HTZI (infinident) incoris NP (infinident) incoris NPM (infinident) incoris TI (infinident) incoris TP (infinident) incoris FI (infinident) incoris WAX (infinident) Mark II TriLuxe Triluxe Forte RealLife Enamic Suprinity Suprinity FC YZ T YT HT CAD-Waxx CAD-Temp monocolor CAD-Temp multicolor MERZ 3M ESPE GC artbloc Temp M-PM Disc Peek Bio Solution LAVA Ultimate LAVA Plus Disc IPS Empress CAD IPS Empress Multi IPS e.max CAD IPS e.max ZirCAD IPS AcrylCAD Telio CAD Cerasmart Initial Zirconia Disk ST Initial Zirconia Disk CT DENTSPLY DEGUDENT MISC Celtra Duo Cercon ht Zirconium oxide Sintered metal Wax PMMA Composite PEEK Non-precious metal Precious metal Titanium

inlab SW 15 SOFTWARE FEATURES 06 TI BASES At present, the following implant systems are supported by the software: MANUFACTURER TYPE DIAMETER Astra Tech OsseoSpeed 3.5 S / 4.0 S 4.5 / 5.0 Biomet 3i Certain 3.4 / 4.1 / 5.0 Biomet 3i Ex. Hex 3.4 / 4.1 / 5.0 Dentsply Implants (Friadent) Frialit / Xive 3.4 / 3.8 / 4.5 / 5.5 Nobel Biocare Nobel Active NP 3.5 / RP 4.3 / 5.0 Nobel Biocare Brånemark NP 3.5 / RP 4.3 / 5.0 Nobel Biocare Replace NP NP 3.5 / RP 4.3 / WP 5.0 / 6.0 Straumann Bone Level 3.3 / 4.1 / 4.8 Straumann SynOcta NN 3.5 / RN 4.8 / WN 6.5 Zimmer Tapered Screw-Vent 3.5 / 4.5 / 5.7 Medentika Implant M-Implant Tapered 3.5 / 5.0 CAMLOG CAMLOG 3.3 / 3.8 / 4.3 /5.0 / 6.0 CAMLOG Conelog 3.3 / 3.8 / 4.3 /5.0 CAMLOG isy 4.5 Thommen Medical Element / Contact 3.5 / 4.0 / 4.5 / 5.0 / 6.0 CASE DETAILS When the case is created, all the relevant information is displayed in the case details side panel. The case details can be displayed during the entire design process. SCANNING PHASE ineos X5 UND ineos Blue The software supports the ineos X5 and ineos Blue scanners. CEREC acquisition systems are not supported. BACKGROUND CALCULATION OF IMAGE CATALOGS The 3D model of the individual image catalogs are calculated in the background during scanning. TRIPLE TRAY IMPRESSION SCANNING A special scanning technique for triple tray impression trays is available for the ineos X5 system. ADDITIONAL IMAGE CATALOGS FOR SCREW-RETAINED BRIDGES A new image catalog was introduced for ineos X5 that enables scanning of the implant positions for screw-retained bridges and bars. New one-piece scan bodies (inpost) were developed for scanning screw-retained restorations. Starting with this version, screw-retained bridges and bars can be created on multi-unit abutments from Medentika and nt-trading. The implant positions are scanned with the screwed-in multi-unit abutments on the lab analogs. SCANNING WITHOUT RESTORATION It is possible to go to the scan phase and scan the model without creating a restoration, e.g., for a partial or a model to be saved as an S T Lfi l e.

inlab SW 15 SOFTWARE FEATURES 07 MODEL PHASE AUTOMATIC BUCCAL REGISTRATION The software automatically joins the upper and lower jaw models using the buccal image field. Correction tools are still available. MODEL AXIS EXTENDED The upper and lower jaws are now visible in the main window. NEW STEP: EDIT JAWLINE In this step, the main jawline of the case is set and the tooth numbers of the preparations are dragged to their positions. AUTOMATIC TRIMMING The software automatically trims the model or dies. Manual trimming is still available. AUTOMATIC PREPARATION MARGIN The software automatically proposes the preparation line. The tools for correcting the line are still available. SEATING AREA The fit of the restorations can be individually adjusted by means of the seating area option and the starting point of the spacer can be d e fi n e d. NO BASE LINE FOR PONTICS NECESSARY Pontics are automatically proposed, therefore a drawing of the base line is no longer required. NEW OPTIONS FOR SETTING THE INSERTION AXIS Starting with this version, the insertion axis can also be set via the option viewing direction. The model is rotated in the insertion axis on the screen and then confirmed. The insertion axis can also be set by touching the direction arrows. DESIGN PHASE PARAMETER PROFILES The parameter profiles created in the configuration can be selected here for the individual restorations. SEPARATE SPACER FOR OCCLUSAL AND RADIAL The spacer can be set separately for the occlusal and radial. APPLY THE PARAMETERS TO ALL This option can be selected if a parameter is to be applied to similar restoration elements. NEW PARAMETERS The following parameters were added in this version: CROWNS, INLAYS, ONLAYS, BRIDGE FRAMEWORKS PARAMETERS Occlusal and radial spacer Margin ramp angle Margin Ramp width DESCRIPTION Space configuration options for the fixation material below the restoration. Acts up to the preparation margin. Determines the angle at which the restoration rises from the margin. Determines the length of the area with which the restoration rises from the preparation margin.

inlab SW 15 SOFTWARE FEATURES 08 GINGIVA PARAMETERS Gingiva cleaning spacer Gingiva spacer Gingiva implant spacer Minimum thickness of the gingiva Gingivaedge thickness Consider instrument geometry Removing undercuts DESCRIPTION Determines the distance from the gingiva element to the gingiva. The distance is also created at the edge of the gingiva element. Determines the distance from the gingivaelement to the gingiva between the edges of the element. The edges always rest on the gingiva. Determines the space between the gingiva element and adhesive cap of the abutment. Determines the minimum wall thickness of the element. Determines the material thickness at the edge of the element. Prevents splintering of the material. Takes the instrument geometry at the bottom of the restoration into consideration. Areas of the element that are smaller than the diameter of the instrument geometry are calculated at the base of the restoration in such a way that they are enlarged with the instrument geometry. Undercuts within the preparation margin are blocked out in the restoration base. CEREC GUIDE 2 PARAMETERS Thickness Spacer DESCRIPTION Thickness of the surgical guide Distance between supporting surface on the residual teeth and inside of the guide body ABUTMENT DESIGN NEW: TOOTH LIBRARIES Starting with this version, tooth libraries can be selected for the initial proposal. The following tooth libraries are available: Candulor, Bonartic, Condyloform, Phyisoset, Physiostar VITA: Physiodens, Lingoform, Vitapan Plus Merz: Artegral NEW STEP: MORPHOLOGY In the morphology step, the tooth shape for the restoration can be selected. The following options for anterior teeth are available: Biogeneric Ovoid, square, and tapered tooth libraries The following options are available for the lateral teeth: Biogeneric tooth libraries NEW STEP: POSITIONING In this step, the restorations can be positioned and scaled independently of the preparations. Along with the option of using the biogeneric application for the restoration proposal, it is also possible to let the software calculate precisely what was positioned. NEW DESIGN TOOLS Edit base line The base lines of the automatically proposed pontics can be changed using this tool. New reduction functions Starting with this version, all the elements of a bridge can be reduced at the same time. The reduction line can be edited before the reduction without having to switch to partial reduction.

inlab SW 15 SOFTWARE FEATURES 09 PRODUCE PHASE inlab Kompakt AND inlab MC XL ARE SUPPORTED Both inlab Compact and inlab MC XL can be selected as milling machines, also the two simultaneously. OTHER PRODUCTION OPTIONS Export to inlab CAM Export to folders (*.stl, *.lab, *dxd, *.ilab), for fabrication on other production machines