Description. Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers

Similar documents
High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Velomitor Piezo-velocity Sensor

and Accelerometers

Low Frequency Velocity Sensor

9000 Series Accelerometers Specifications

Proximity Transmitters and Seismic Vibration Transmitters

3500/62 Process Variable Monitor

1701/22 FieldMonitor Management Interface Module

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Description. Specifications and Ordering Information 3300 Proximity Transducer System Patents: 5,016,343; 5,126,664; 5,351,388; and 5,685,884

Dynamic Pressure Charge Amplifier

2100 Eddy Current Probe Systems Specifications

3500/40M Proximitor* Monitor

3300 XL 8mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring

3300 XL NSv* Proximity Transducer System Bently Nevada* Asset Condition Monitoring

IMVIB. Online vibration monitoring for Ariel compressors

3500/25 Enhanced Keyphasor*Module

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

How To Power A Schen

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

PROXPAC XL Proximity Transducer Assembly

Troubleshooting accelerometer installations

Combustion Dynamics Instrumentation

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

SEISMIC VELOCITY TRANSDUCER T1-40

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Vibration Sensors. SKF Condition Monitoring

DS 600. A contact free flux gate based current measurement sensor 600A rms

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Torque Transducers MEASURING ELECTRONIC

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

3500/93 System Display

Givare NC-SRS 280 och 880

Telephone- and leased line modem for industrial applications TD-36

3500/22M Transient Data Interface

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Description. Dimensions. Features. precision works better

Power Supplies 3. SDN-P DIN Rail Series

SKF Microlog Analyzer Accessories Catalog

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

QR12 (1.22 ) Diameter Optical Encoder

VIBRATION SWITCHES SOLID STATE

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

STRATO LED Drivers 70W, Single output

Analog signal converters CC-E I/I Current / current isolators

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Differential-Hall-Effect based Sensors Series A5S

Inductive sensor NI10-M18-Y1X-H1141

Product Overview 9100D

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Differential-Hall-Effect based Sensors Series A5S Overview

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Product Data. Brüel & Kjær B. DeltaTron Range

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Decoding an Accelerometer Specification. What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc.

Redundancy Module QUINT-DIODE/40

Fiber Optic High Density ACC Sensor System Faser Optisches Beschleunigungs-Messsystem

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Rack mounted telephone- and leased line modem for industrial applications

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

Features. Picture. Specifications

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

PRODUCT DATA 4397A/ 8A/ 9A. Description. Miniature DeltaTron Accelerometer Type 4397A DeltaTron Accelerometers Types 4398A, 4399A FEATURES USES

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Pressure transmitter For general industrial applications Model A-10

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Series 6000 Torque measured metal bellow coupling

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Series 7500 Torque Sensor

Times Microwave Systems Hermetically Sealed Assemblies

Electronic Pressure Switch EDS 3000

PRODUCT INFORMATION. Range of HUMS and Engine-monitoring Accelerometers Type , , 4523, 8345 and 8347-C.

3DLevelScanner II TECHNICAL DATA SHEET

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

MCR1900 Media Converter 19-Slot Chassis

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

Speed sensor MiniCoder GEL 247

I-PEX MHF4 Micro Coaxial Connector

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

How To Use A Flowmeter

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

The Do s and Don ts of Pressure Transducers

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

ABSOLUTE ROTARY ENCODER ETHERNET/IP

Mounting Instructions. Torque Transducer. A en

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Transcription:

Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers R Description These accelerometers are intended for critical machinery applications where casing acceleration measurements are required, such as gear mesh monitoring. The 330400 is designed to address the requirements of American Petroleum Institute Standard 670 for accelerometers. It provides an amplitude range of 50 g peak and a sensitivity of 100 mv/g. The 330425 is identical except it provides a larger amplitude range (75 g peak) and a sensitivity of 25 mv/g. Caution If housing measurements are being made for overall protection of the machine, thought should be given to the usefulness of the measurement for each application. Most common machine malfunctions (imbalance, misalignment, etc.) originate at the rotor and cause an increase (or at least a change) in rotor vibration. In order for any housing measurement alone to be effective for overall machine protection, a significant amount of rotor vibration must be faithfully transmitted to the bearing housing or machine casing, or more specifically, to the mounting location of the transducer. In addition, care should be exercised in the physical installation of the transducer. Improper installation can result in a degradation of the transducer s performance, and/or the generation of signals which do not represent actual machine vibration. Upon request, Bently Nevada can provide engineering services to determine the appropriateness of housing measurements for the machine in question and/or to provide installation assistance. Specifications Parameters are specified at +25±5 C (+77±9 F) unless otherwise indicated. Note: Operation outside the specified limits will result in false readings or loss of machine monitoring. Electrical 330400 Sensitivity: Acceleration range: 10.2 mv/m/s 2 (100 mv/g) ±5% at 100 Hz 490 m/s 2 (50g) peak overall acceleration within the 1 Hz to 20 khz frequency span. Vibration at frequencies above 20 khz, especially at the transducer s resonance, will significantly decrease this range. BNC Part Number 141638-01 Page 1 of 5

Amplitude linearity Noise floor: 330425 Sensitivity: Acceleration range: Amplitude linearity: Noise floor: Both Units Frequency response: Mounted resonant frequency: ±1% to 490 m/ s 2 (50 g) peak 0.004 g rms 10 Hz to 20 khz 2.5 mv/m/s 2 (25 mv/g) ±5% at 100 Hz 735 m/s 2 (75 g) peak overall acceleration within the 1 Hz to 20 khz frequency span. Vibration at frequencies above 20 khz, especially at the transducer s resonance, will significantly decrease this range. ±1% to 735 m/s 2 (75 g) peak 0.01 g rms 10 Hz to 20 khz 10 Hz to 15 khz (600 cpm to 900,000 cpm) ±3dB; 30 Hz to 10 khz (1800 cpm to 600,000 cpm) ±10% 30 khz minimum 33 khz typical Electromagnetic Compatibility: Hazardous Area Classification: CSA/NRTL / C: EUROPEAN: Mechanical Mounting Surface: Mounting torque: Meets all European EMC directives. Multiple approvals for hazardous areas certified by Canadian Standards Association (CSA/NRTL/C) in North America and by LCIE/CENELEC in Europe. Exia for Class I, Division 1, Groups A, B, C and D; Class II, Division 1, Groups E, F and G; Class III, Division 1, when installed with an approved zener barrier or galvanic isolator per drawing 132525. T3C @ Ta=100ºC, T5 @ Ta=40ºC Non-incendive for Class I, Division 2 when installed per drawing 132524. EEx ia for Zone 0, Group IIC, LCIE certificate number LCIE 98 ATEX6013 X, when installed with an approved zener barrier or galvanic isolator. T4 @ Ta=100ºC, T5 @ Ta=40ºC 32 µinch rms 3.4 N m (30 in lb.) Amplitude of resonant peak: 20 db max Case material: 300 Series stainless steel Transverse sensitivity: Less than 5% of the Sensitivity at 100 Hz Connector: Weight (no cable): 3-pin MIL-C-5015 Receptacle 80 g (2.5 oz), typical Base strain sensitivity : Power requirements dc voltage: 0.100 g/µstrain 0.0005 g/µstrain with 37439-01 Mounting Base -24 Vdc Mounting angle: Environmental Limits Operating and storage temperature: Any orientation -55 C to +121 C (-67 F to +250 F) Bias current: Output bias voltage: 2 ma nominal -8.5 Vdc nominal Relative humidity: 100% condensing, non-submerged. Case is hermetically sealed. Grounding: Case isolated Maximum cable length: 305 metres (1000 ft) with no degradation of signal Electromagnetic Compatibility BNC Part Number 141638-01 Page 2 of 5

Electrostatic discharge: Electrical fast transients: Radio frequency interference (radiated): Radio frequency interference (conducted): Ordering Information 330400 Accelerometer 330400-AXX-BXX 330425 Accelerometer 330425-AXX-BXX Option Descriptions A: Mounting Thread Option B: Agency Approval Option Accessories Standard Cables EN 61000-4-2 (1991), Criteria B EN 61000-4-4 (1988), Criteria B EN 50140 (1993), Criteria A EN 50141 (1993), Criteria A 0 1 1/4-28 UNF integral stud 0 2 M8 X 1 integral stud 0 0 None 0 5 Multiple Approvals Note: (CSA/NRTL/C) in North America and by LCIE / CENELEC in Europe 16925 (22 AWG) cable with 3-socket plug at one end, terminal ring lugs at the other end. 16710 3-conductor shielded 0.5 mm 2 (22 AWG) armored cable with 3-socket plug at one end, terminal ring lugs at the other end. Part Number-AXX Cable Length Option in feet. 127088-01 User Guide. 00531080 37439-01 Order in increments of 1.0 foot Minimum length (armored): 3.0 ft (0.9 m) Minimum length (unarmored): 2.0 ft (0.6 m) Maximum length (armored): 99 ft (21 m) Maximum length (unarmored): 99 ft (30 m) Examples: 1 5 = 15 ft (4.57 m) 2 0 = 20 ft (6.10 m) Mating connector for 330400 Accelerometer. Mounting Base, ¼-28 to ¼-28. Reduces base strain sensitivity. 43217 Accelerometer Mounting Kit used with extension part number 108576-01 and O-ring part number 04290422 to allow room for the 330400 or 330425 accelerometer. (See separate datasheet.) 130539-XX 3-conductor shielded 1.0 mm 2 (18 AWG) cable with 3-socket plug and fluorosilicone elastomer boot at one end, terminal lugs at the other end. Cable length can be ordered in 1 foot increments. Maximum length 99 feet. A manual is available to assist with installation of this cable (part number 133080-01). 2001 Bently Nevada Corporation used in this document are registered marks of Bently Nevada Corporation BNC Part Number 141638-01 Page 3 of 5

R Dimensional drawing 3 Pin, Mil - C - 5015 Receptacle BENTLY NEVADA MADE IN U.S.A. PN 330400 100 mv/g 2 (10.2 mv/m/s ) 52.1 (2.05) 61.0 (2.40) Mounting Stud 1/4-28 (A01) M8 X 1 (A02) 15/16" Hex (A01), 24 mm Hex (A02) 25.4 (1.00) Diameter Figure 1: Acceleration Transducer dimensional drawing Dimensions are in millimetres (inches) BNC Part Number 141638-01 Page 4 of 5

25 20 db referenced to 100 Hz 15 10 5 0-5 10 100 1000 10000 100000 Frequency (Hz) Figure 2: Typical Amplitude Response 1 0.5 db referenced to 100 Hz 0-0.5-1 -1.5-2 10 100 1000 10000 Frequency (Hz) Figure 3: 10 10,000 Hz Typical Amplitude Response Detail BNC Part Number 141638-01 Page 5 of 5