Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.



Similar documents
Scout Vessel Guard. A hydrogel membrane with exceptional handling characteristics.

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Technique Guide. Norian SRS Fast Set Putty. Calcium phosphate bone void filler.

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

(English) NEXUS SPINE SPACER SYSTEM

chronos BOne VOid Filler Beta-Tricalcium Phosphate (b-tcp) bone graft substitute

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Battery Power Line. Battery-driven power tool system for orthopaedics and traumatology.

ANTERIOR LUMBAR INTERBODY FUSION (ALIF) Basic Anatomical Landmarks: Anterior Lumbar Spine

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

IVALON Ophthalmic. IVALON Ophthalmic Products

OVER 45 YEARS TEXTILE GRAFT TECHNOLOGY EXPERIENCE MAQUET THE GOLD STANDARD

Histological and Qualitative Evaluation of Hydrogel Cloth in a Sheep Lumbar Spine Model

PERIPROSTHETIC IMPLANTS

Bard * PerFix * Plug. Technique Guide. A Modified Technique with the. Open Inguinal Hernia Repair

Information for the Patient About Surgical

41 Assisting with Minor Surgery

Ventral Hernia Repair

Arizona State University Institutional Animal Care and Use Committee STANDARD INSTITUTIONAL GUIDELINE RODENT SURGERY

Cranial/Neurosurgical Implants

Patient Information. Lateral Lumbar Interbody Fusion Surgery (LLIF).

Get the Facts, Be Informed, Make YOUR Best Decision. Pelvic Organ Prolapse

TREATMENT 1. Control bleeding by applying pressure over wound with Gauze Pads (Surgical Supply-4). 2. Contact Surgeon for laceration repair options.

Patient Information. Anterior Cervical Discectomy and Fusion Surgery (ACDF).

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

The information contained in this document is intended for healthcare professionals only.

Knotilus TM. Anchor Instability Repair. Technique Guide

HUNTER TENDON IMPLANTS

Open and Endoscopic Forehead Lift. Plastic Surgery. For All Brow and Forehead Lift Procedures. Revolutionizing. Soft-Tissue Fixation

Lentur Cable System. Surgical Technique

Bankart Repair using the Smith & Nephew BIORAPTOR 2.9 Suture Anchor

Hand Hygiene and Infection Control

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Achilles Tendon Repair, Operative Technique

TriLock 1.5 Implants for the Phalanges

Minimally Invasive Spine Surgery

James A. Sanfilippo, M.D. CONSENT FOR SPINAL SURGERY PATIENT: DATE:

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

Aspira* Pleural Drainage Catheter

All Suture Anchor. with IntelliBraid Technology

Chapter 33. Nerve Physiology

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine

Orthopaedic Spine Center. Anterior Cervical Discectomy and Fusion (ACDF) Normal Discs

COPYRIGHT ASPS. Breast Augmentation. The Symbol of Excellence in Plastic Surgery

Patient Guide to Lower Back Surgery

IACUC Policy on Survival Rodent Surgery

Advances In Spine Care. James D. Bruffey M.D. Scripps Clinic Division of Orthopaedic Surgery Section of Spinal Surgery

How To Become A Surgical Technologist

KnifeLight. Carpal Tunnel Ligament Release. Operative Technique

MatrixNEURO CMF Matrix

esims Web Overview. Synthes Information Management Suite.

Hip Replacement Surgery Understanding the Risks

Provide chairside support during the extraction of teeth and minor oral surgery

Open Discectomy. North American Spine Society Public Education Series

Selection & Use of Surgical Needles

PSI Patient Specific Implants. Derived from CT data for excellent reconstructive results.

Instructions for Use. Device Description The AMPLATZER Vascular Plug II is a self-expandable nitinol mesh occlusion device (see Figure 1).

Patient Guide to Neck Surgery

Plasmax Plasma Concentration System BIOLOGICS

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

Open and Endoscopic Forehead Lift. Plastic Surgery. For All Brow and Forehead Lift Procedures. Revolutionizing. Soft-Tissue Fixation

Degenerative Spine Solutions

IMPLANT MENTOR EFFECTIVE JANUARY 2012 BREAST IMPLANTS NOT FOR DISTRIBUTION IN USA APPROVED FOR EMEA REGION. Mentor Worldwide LLC Rev C

MatrixNEURO. The next generation cranial plating system.

Aspira* Peritoneal Drainage Catheter

ARTHROSCOPIC HIP SURGERY

Posterior Referencing. Surgical Technique

Placement of Epidural Catheter for Pain Management Shane Bateman DVM, DVSc, DACVECC

Minimally Invasive Spine Surgery What is it and how will it benefit patients?

Breast Augmentation. If you are dissatisfied with your breast size, augmentation surgery is a choice to consider. Breast augmentation can:

Chapter 11. Everting skin edges

CeSpace Titanium / PEEK

ONSTEP Technique. Technique Guide * Anterior Approach to a Part Preperitoneal, Part Intramuscular Inguinal Hernia Repair

Hydrogel Competence in Eye Surgery

Labral Repair. Surgical Protocol by Ronald Glousman, M.D. and Nicholas Sgaglione, M.D.

Small Battery Drive. For orthopaedic trauma applications.

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

METAL HEMI. Great Toe Implant SURGICAL TECHNIQUE

Exeter X3 RimFit. Acetabular Cup Surgical Protocol

Product Reference Guide

Prevention and control of infection in care homes. Summary for staff

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

Shoulder Restoration System

STANDARD OPERATING PROCEDURE #201 RODENT SURGERY

BRYAN. Cervical Disc System. Patient Information

Aesculap Spine activ L

DRY CLEANING PAPER DOCUMENTS

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

Shoulder Arthroscopy

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

Surgical scissors and forceps Product List

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

ZERO-P VA. Variable angle zero-profile anterior cervical interbody fusion (ACIF) device SURGICAL TECHNIQUE

Contents PACKING PRODUCTS. Nasal/Sinus Packs Bacteriostatic PVA Foam...PSS-100. Nasal Packs Rhino Rocket...PSS-105

Transcription:

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery. Technique Guide Instruments and implants approved by the AO Foundation

Table of Contents Introduction Scout Vessel Guard 2 Indications 5 Warnings 6 Surgical Technique Handling 7 Size Implant 8 Insert Implant 10 Apply Fixation 11 Final Position 12 Implant Removal 13 Product Information Implants and Instruments 14 Image intensifier control Scout Vessel Guard Technique Guide Synthes

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery. The Scout Vessel Guard is a flexible, nonabsorbable membrane, allowing it to contour to the anatomy. It is designed to be placed between the anterior spine and proximate vessels during anterior lumbar surgery. The Scout Vessel Guard is a permanent implant. In cases of revision surgery or subsequent adjacent level surgery, the presence of the vessel guard will aid the surgeon in identifying the location of the index level, and in visualizing and identifying vessels and soft tissue structures. The Scout Vessel Guard is MR Safe. The safety and effectiveness of this device for reducing the incidence, severity and extent of postoperative adhesion formation have not been established. 2 Synthes Scout Vessel Guard Technique Guide

The Scout Vessel Guard can be used over a variety of spinal implants: Total disc replacements (such as ProDisc-L) (Figure 1) Stand-alone ALIF devices (such as SynFix-LR) (Figure 2) Anterior plates (such as ATB, Antegra or Antegra-T) (Figure 3) ALIF spacers (such as FRA, ALIF or CC-ALIF) (Figure 4) 1 2 The Scout Vessel Guard is made from hydrogel (water, polyvinyl alcohol (PVA) and polyvinylpyrrolidone (PVP)) and packed wet in phosphate buffered saline (PBS). 3 4 Scout Vessel Guard Technique Guide Synthes 3

Scout Vessel Guard. Material Characteristics Maximum pore size of 0.08 microns 1 Particles larger than that cannot pass through Hydrophilic Enhances fluid transport properties of the membrane Provided hydrated Pliable Contours to anatomy Homogeneous, translucent and white in color Able to maintain visualization of primary spine implant Customizable footprint Can be trimmed intraoperatively to fit patient anatomy and application Scout Vessel Guard Hydrophilic sheet absorbing fluid Hydrophobic sheet repelling fluid 1. Test data available on file at Synthes, West Chester, PA 4 Synthes Scout Vessel Guard Technique Guide

Indications The Scout Vessel Guard is indicated as a cover for vessels during anterior vertebral surgery. Contraindications Use of the Synthes Scout Vessel Guard is contraindicated for Reconstruction of: cardiovascular defects central nervous system defects peripheral nervous system defects hernias soft tissue deficiencies Use of this product in applications other than those indicated has the potential for serious complications, such as pullout of the fixation or undesired healing to surrounding tissues. Patients with infection, e.g., inflammatory, bacterial bone diseases (posttraumatic or chronic osteomyelitis) and softtissue infections at the site of proposed implantation. Patients with demonstrated allergy or foreign body sensitivity to any of the implant materials. Scout Vessel Guard Technique Guide Synthes 5

Warnings One of the potential risks identified with any surgical procedure is death. Other potential risks associated with the use of this device which may require additional surgery, include: neurological injury vascular or visceral injury loss of fixation Discard and DO NOT USE previously opened or damaged devices. Use only devices that are packaged in unopened and undamaged packages. DO NOT USE if there is loss of sterility of the device. DO NOT USE if the device appears dehydrated or if moisture is not visible in the inner package. The Synthes Scout Vessel Guards are sterilized by gamma radiation. DO NOT RESTERILIZE. CONTENTS STERILE UNLESS INNER PACKAGE IS OPENED OR DAMAGED. Do not use the Scout Vessel Guard after the expiration date printed on the package label. Product should be stored at room temperature, 15 C 30 C (59 F 86 F). The safety and effectiveness of this device for reducing the incidence, severity and extent of postoperative adhesion formation have not been established. 6 Synthes Scout Vessel Guard Technique Guide

Handling Handling 03.650.008 Atraumatic DeBakey Forceps 1 Keep the sterile and hydrated product unopened in its protective packaging until ready to use (Figure 1). A clear retainer is included in the package to keep the vessel guard flat during transit and storage. Remove the clear retainer from package before handling vessel guard (Figure 2). To maintain flexibility of the implant, it is important to minimize dehydration, which can be caused by prolonged exposure to air. If the implant becomes dehydrated, soak it in sterile liquid (i.e., saline or water) until flexibility is restored. Sterile liquid can be added to the tray as needed to maintain hydration and keep the implant flat (Figure 3). 2 3 The vessel guard should be aseptically transferred from its tray directly to the site of application, using clean, sterile gloves and/or atraumatic instruments such as DeBakey forceps (Figure 4). Maintain strict asepsis around the surgical site and avoid skin contact during transfer into the wound. Avoid direct contact of the vessel guard with any sharp objects to protect the hydrogel material. 4 Scout Vessel Guard Technique Guide Synthes 7

Size Implant 1 Select implant size Choose the appropriate implant size based on patient anatomy and the surgical exposure. Ensure that the vessel guard will completely cover the desired area. Vessel guards are shown actual size. 110 mm 55 mm 65 mm 65 mm 8 Synthes Scout Vessel Guard Technique Guide

2 Size implant Size the material using sharp, sterile scissors, such as Mayo scissors. Important: If the vessel guard is cut too small, excessive stress may be placed on the tissue or material and fixation pullout could occur. If the material is cut too large, excessive wrinkling may occur, compromising results. Size the vessel guard appropriately for the intended area. Loose, fragmented pieces of the implant should not be used in the patient. Scout Vessel Guard Technique Guide Synthes 9

Insert Implant 3 Insert implant 1 Instrument 03.650.008 Atraumatic DeBakey Forceps Place the vessel guard over the spine in the exposed vessel area using clean, sterile gloves and/or atraumatic instruments such as DeBakey forceps (Figure 1). Important: Using sharp instruments may damage the vessel guard and compromise vessel guard function. Ensure that the implant is placed exterior to the disc space and without wrinkles (Figure 2). 2 Note: Retractor blades or other flat instruments placed near the application site may be used to facilitate smooth and even placement of the vessel guard (Figure 3). 3 10 Synthes Scout Vessel Guard Technique Guide

Apply Fixation 4 Apply fixation Fix the vessel guard in place to prevent migration. Choose nonabsorbable sutures with a noncutting needle, such as a taper or piercing point. Use the smallest needle appropriate for the application. To avoid mechanical damage and suture hole elongation, smoothly pierce the vessel guard and follow the curve of the needle through the material. Use minimal tension when pulling the suture line or when placing a knot. Secure the vessel guard to adjacent nonvascular tissue using the fewest possible sutures, with a minimum of two points of fixation. Important: Always fix the vessel guard in place to avoid implant migration. Do not stretch the vessel guard while fixing in place; the implant should be smoothly placed without wrinkles or tension. Excessive tension on the implant or sutures may damage the implant and compromise vessel guard function. Using fixation means other than those listed above is not recommended, as they may cause damage to the implant or surrounding anatomy. Scout Vessel Guard Technique Guide Synthes 11

Final Position 5 Release vessels Release retraction on the vessels so they lay in their natural position. Take care not to place excessive force on the vessel guard while the vessels move into position over the implant. 6 Verify final position The vessel guard should be positioned between the vessels and the spine. To reposition the vessel guard, remobilize the vessels, and cut and remove sutures. Adjust the position and resuture. 12 Synthes Scout Vessel Guard Technique Guide

Implant Removal In the event that the vessel guard must be removed, remobilize the vessels, cut the sutures and remove the implant and sutures. Properly discard any implant materials after removal. Important: All loose, fragmented pieces of the vessel guard should be removed and discarded. Do not resterilize or reuse the vessel guard after removal. The vessel guard should be removed in the event of unresolved infection. Scout Vessel Guard Technique Guide Synthes 13

Implants and Instruments 08.650.101S Scout Vessel Guard, 65 mm width x 55 mm height x 1 mm thick, sterile 55 mm 65 mm 08.650.102S Scout Vessel Guard, 65 mm width x 110 mm height x 1 mm thick, sterile 110 mm 65 mm 14 Synthes Scout Vessel Guard Technique Guide

03.650.008 Atraumatic DeBakey Forceps Note: For additional information, please refer to package insert. For detailed cleaning and sterilization instructions for the Atraumatic DeBakey Forceps, please refer to http://www.synthes.com/sites/na/medicalcommunity/pages/cleaning_and_sterilization.aspx or to the below listed insert, which will be included in the shipping container: Processing Synthes Reusable Medical Devices Instruments, Instrument Trays and Graphic Cases DJ1305 Scout Vessel Guard Technique Guide Synthes 15

Synthes USA 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 Fax: (610) 251-9056 Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185 www.synthes.com 2011 Synthes, Inc. or its affiliates. All rights reserved. Synthes and Scout are trademarks of Synthes, Inc. or its affiliates. Printed in U.S.A. 3/12 J9603-B