The Eco-Design Directive ErP. The Newest Requirements.



Similar documents
ECODESIGN by FLÄKT WOODS EU REGULATION 1253 AND 1254/2014 FOR RESIDENTIAL AND NON-RESIDENTIAL VENTILATION UNITS

How To Get A Passive House

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

DISCUSSION PAPER ECODESIGN FOR ENERGY RELATED PRODUCTS INTEGRATED INTO OTHER ENERGY RELATED PRODUCTS

COMPARISON OF DIFFERENT HVAC SYSTEMS IN MULTI- STOREY APARTMENT BUILDINGS IN HELSINKI

INFORMATION ABOUT IE3 AND NEMA PREMIUM- MOTOR CHANGEOVER. Blowers and side channel blowers.

Smart Cities and Sustainable Technology

Analysis of HVAC Control Strategies

DATA PD RE21.., KX..., Quick Release Valves. Product. Function. Technical Features. Range Overview

Direct Fresh Air Free Cooling of Data Centres

How To Comply With The Erp Directive For Ground Source Heat Pumps

THE ErP DIRECTIVE 2009/125/EC KEY FACTS» REGULATIONS 327/ /2009. ErP. - Version 2.0

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

Drives and motors. A guide to using variable-speed drives and motors in car parks

Air Conditioning in Green Office Buildings?

eq Top/TopMaster Air Magic by Fläkt Woods

CE Marking: Your Key to Entering the European Market

Which filter class for supply air is required in a typical HVAC system?

Scope of Work. See for resources available

Flexit air handling unit K2 R

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Drives and motors. A guide to using variable-speed drives and motors in data centres

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

i n d o o r a i r q u a l i t y I AQ EN 13779:2007 European standard Camfil Farr clean air solutions

Climate change & the insurance industry. Cheuvreux Financials Conference, London, 1 & 2 December 2009

Compact. Efficient. TROX.

ZC-24DO CANopen I/O Module: 24 Digital Outputs

lindab we simplify construction Air Handling Units Product Overview

your comfort. our world. R22 replacement A complete solution for R22 Sky Air systems

RRV934. Multi-controller. Synco living

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

CONTROL STRATEGIES FOR HVAC SYSTEMS

REPORT FROM THE COMMISSION TO THE EUROPEAN PARLIAMENT AND THE COUNCIL. on the voluntary ecodesign scheme for games consoles

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Air Handling Technology. Air Conditioning, Ventilation and Refrigeration Technology Made in Germany Efficient, Safe, Innovative and of High Quality

Duct Humidity Transmitter

All-in-One: Packaged Air Handling Units

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Ventilation for non-residential buildings Performance requirements for ventilation and room-conditioning systems

Can old buildings be just as energy-efficient as new ones?


User s Guide. Flexit MagiCAD plugin

RPV - RP - RA air handling units

Energy Efficiency Insurance. Product overview

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Siemens Hybrid Power Solutions. Cost and emission reduction by integrating renewables into diesel plants

Ecodesign Directive 2009/125/EC & Energy Labelling Directive 2010/30/EU State of Play. Eurovent General Assembly

Copyright 2013 wolfssl Inc. All rights reserved. 2

HVAC Processes. Lecture 7

Energy Consumption Increases Slightly in Renewables Continue to Grow / Advantages Due to Weather, Economic Trend, and Immigration

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

The Passenger Car (Fuel Consumption and CO 2 Emissions Information) Regulations

Uninterruptible Power Supply Product Regulations and Standardization in the European Union. By Matteo Tricarico Patents and Regulatory Engineer

Delivering exceptional performance and Ecovalue. Ecocent

Eurovent Certification

Building Energy Systems. - HVAC: Heating, Distribution -

The new Ecodesign regulation for heaters: what does it mean for heat pumps?

Working Capital Analytics Overview. SAP Business Suite Application Innovation March 2015

Supplying new machinery

B Recommended land pattern: [mm] C Stencil suggestion: SSt. SKl CHECKED DATE

product information credit confirmation risk cover march 2012

CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel.

TX OPEN RS232/485 module

ErP made easy What does it mean to merchants? What does it mean to installers?

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Model: DC-A2IO Advanced HVAC Controller

Triple M1 The new MiniVent family. The professionals choice

Intertek Testing Services 70 Codman Hill Road Boxborough, MA WORLD LAB

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

Overview of types. Technical data

ENVIRONMENTAL POLICY STATEMENT

System solution for data centres

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Instruction Manual MSC710 MSC710-U MSC710-I

How To Manage Ansap Bw System For Linxess

An overview of Euro VI for trucks over 3.5t. Brought to you by Mercedes-Benz

Daikin Altherma Hybrid Heat Pump

Digital input modules

Solar energy Solar technology in endurance testing

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Flexit SPIRIT K2R. Air handling unit with integrated kitchen hood

Transcription:

The Eco-Design Directive ErP. The Newest Requirements. Tightened Requirements of the EC-Regulation 1253/2014/EG are forcing designers and manufacturers of AHUs to adapt previous solutions.

The Eco-Design Directive ErP. The European ErP-Directive 2009/125/EG (Energy-related-Products-Directive), also called the Eco-Design Directive, defines the minimal requirements for energy-related products. The objective of the ErP-Directive is the reduction of energy consumption and the CO 2 -emission rates as well as an increase of the overall share of renewable energies. This directive applies for all products placed on the market within the European Economic Area (EEA). Exports from the European Community (EC) are not affected by the ErP-Directive. Relevant for the AHUs is the EC-Directive 1253/2014/EG that came into force on November 26th 2014. Within the framework of this directive and as of January 1st 2016, new requirements concerning the energy efficiency of AHUs will apply within the European Economic Area (EEA). With robatherm, you are always on the safe side The discussion about new requirements on Air Handling Units under the ErP-Directive is characterized by uncertainty and contrarinesses. As a premium manufacturer, robatherm feels responsibility to address the topic and to deliver comprehensive and qualified information to all queries concerning this issue. We are happy to advice you about our possible solutions. Please send your questions about the Eco-design directive ErP via e-mail to ErP@robatherm.com. Our ErP-team is always at your disposal. Page 1 robatherm 04/2016

Answers to most important questions concerning AHUs robatherm 04/2016 Page 2

The Requirements for Non-Residential Ventilation Units at a Glance Unidirectional Ventilation Unit (UVU) Bidirectional Ventilation Unit (BVU) Page 3 robatherm 04/2016

The Consequences of the ErP-Directive The tightened requirements of the ErP-Directive have far-reaching consequences for both AHUmanufacturers and designers. This is clearly illustrated by the following example. Under the same general conditions for example, an AHU that was designed for 2015 looks completely different than a solution that complies to the ErP-Stage 2016 or even the ErP-Stage 2018. General Conditions Combined supply and exhaust air unit Air flow volume: 10,000 m³/h (Supply Air) / Air flow volume: 10,000 m³/h (Exhaust Air) Filters F7 (ODA), Filters M5 (ETA) HRS-System: Run-around coils system Additional Components: 1 air-heater and 1 damper in the supply air, 1 damper in the exhaust air EC-Fans Air Conditions (DIN EN 308) Outdoor Air: 5 C, 0% relative humidity Exhaust Air: 25 C, 0% relative humidity AHUs according to the stand of 2015 Abbreviations for types of air (as specified in DIN EN 13779): ODA = outdoor air, SUP = supply air, ETA = extract air, EHA = exhaust air robatherm 04/2016 Page 4

AHUs in accordance with the requirements for 2016 (ErP-Directive) AHUs in accordance with the requirements for 2018 (ErP-Directive) Page 5 robatherm 04/2016

Comparison of the Three Unit Concepts These specific figures only refer to the designated example. However, during the course of the ErP- Directive, it can be presumed that the space required for AHUs in the future shall increase due to larger dimensions. An increase of investment costs can be anticipated, which to a large extent shall be based on the increased HRS-Systems requirements. With the help of TrueBlue Efficiency Certificate by robatherm, the three different unit solutions are combinable with each other. For the calculation, the following basic assumptions - amongst other things - applied: Location Munich Type of Usage: Group Office Operating Time: 5 Days/Week (5:00 am - 6:00 pm) Are you interested in a complete TrueBlue Efficiency Certificate? Write us an e-mail to trueblue@robatherm.com and we ll send you the complete TrueBlue Efficiency Certificate. We d be more than happy to carry out an individual TrueBlue Efficiency Certification for your project. robatherm cannot accept any guarantee or liability for the correctness and completeness of this document s contents. Illustrations and descriptions partially include accessories not included in the standard design. Subject to technical alterations. Version 04/2016 Copyright by robatherm.

robatherm Industriestrasse 26 89331 Burgau, Germany Tel. +49 8222 999-0 Fax +49 8222 999-222 info@robatherm.com www.robatherm.com