Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Similar documents
EcoTouch Insulation with PureFiber Technology

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

DEFAULT HEAT LOSS COEFFICIENTS

2014 British Columbia Building Code Changes

2009 IECC Update. Scope. Content. International Energy Conservation Code

How To Repair A Boat Landing Deck With A Boat Bed

Foundation. Foundation

INSTALLATION INSTRUCTIONS FOR MINERAL FIBER BATTS

Additions and Alterations

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

Comment Form on Proposed Gut Rehabilitation Alternatives

ROOFS, SNOW AND ICE DAMS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Heating Load Calculation

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Performance of 8 Passive House Envelopes in Cold Climates

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Housing Fact Sheets. Insulation Check-Up

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

GreenGuard Housewrap Installation Guide

Avoiding Air Barrier Pitfalls

Managing Trade Contractors for High Performance Homes. Carl Seville

Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION

Fiberglas, Exterior Wall Thermal Insulation

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

March 14, Installation of Bay, Bow and Garden Windows

Structure Survey Findings:

Best Basement Water Management Practices

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Page & Turnbull imagining change in historic environments through design, research, and technology

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Insulation R-Value Comparisons

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

CHAPTER 5: INSULATION: MATERIALS AND TECHNIQUES

) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY

CONDENSATION IN REFRIDGERATED BUILDINGS

Renovating Your Basement

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

solutions & tips six Wise Energy Guide Building envelope solutions and simple tips AIR SEALING

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Asphalt Shingle Application Requirements

HOW TO INSULATE CATHEDRAL CEILINGS

Signs of insulation problems In the winter. In the summer. conditioning system

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

R-Value and Densities Chart

State of Connecticut Department of Public Health RADON PROGRAM

PDmB, Inc. Definitions

FORM DESIGN. easy to work with, and generally available.

IECC Compliance Guide for Homes in Virginia

Chapter 2: Foundations

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

INSTALLATION OF A BAY WINDOW

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

Underwriters Laboratories Testing Information

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

Mark Cramer Inspection Services, Inc.

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Preventing Ice Dams on Roofs

United States. Why You Should Insulate Foundations. There is a science to adding value.

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.

Common Problems with Walls

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

Clad Direct Glaze Window Installation Instructions

Inspecting to a higher standard.

Insulation Products For Residential Thermal Applications ROXUL. Better Best ROXUL. Solutions For Residential Thermal Applications.

EAST LYME HIGH SCHOOL

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

CHAPTER 7: Building Systems ROOFING SYSTEMS

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

High R-Value Does Not Always Mean High Performance

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Pre-Drywall Inspection Report

BUILDING IN ALASKA HCM-00952

Engineered Wood Foundations

PANELIZED HOME INSTALLATION GUIDELINE

HomeSpec REPORT SUMMARY

LAYING BLOCK AND BRICK

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Retrofitting an Insulated Cold Roof

Zen House. A Case Study on Design, Construction and Cost/benefit Analysis of a High Performance Home. Presentation for Net Zero Networking & Exchange

Superform Products Ltd.

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

Chapter 3 Pre-Installation, Foundations and Piers

Transcription:

R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed between steel studs, there is significantly increased risk of moisture infiltration and thermal bridging. The best practice for insulating metal framing is to install rigid insulation inside the exterior wall; more detailed information can be found in the section Envelope, INSULATION RIGID / SIPS. NR-E-IB2 Pressure or Friction Fit Insulation should be cut to fit snugly against studs on all sides, and should completely fill the cavity with no air gaps. Cut lengths of insulation should be butted together with no gaps. Friction fit batts are slightly wider than the stud cavity and so held in place by friction, not stapling. Friction fit batts should not be used in walls over 8 feet tall. Face & Inset Stapling Push batt into stud cavity so that it makes contact with framing, especially at corners and sides. Then pull batt forward to full loft so that it fills the whole cavity. NR-E-IB3 (1) (1) Face Stapling: Paper flanges are stapled to stud face. This method of installation is best practice and avoids loss of performance from air gap channels created with inset stapling. (2) Inset Stapling: Insulation should be compressed only as far as is required to staple the flange to the inside of the stud. Extra compression will result in loss of performance therefore this method is NOT RECOMMENDED. NR-E-IB4 (2) NR-E-IB1: PLACEHOLDER NR-E-IB2: Sierra Building Science, Inc. NR-E-IB3: Architectural Energy Corporation NR-E-IB4: Pacific Northwest National Lab

INSULATION BATT NR-E-IF5 NR-E-IF6 NR-E-IB7 Obstructions Junction boxes that back to outside walls should have insulation cut to fit snugly around them, and behind them, to fill the cavity. Similarly, insulation should be cut to fit around ceiling exhaust fans. All holes in junction boxes whether there are wires entering the boxes there or not should be air sealed. Notes: Split, Don t Stuff Take the time to split insulation to fit snugly around electrical wires and plumbing. Do not stuff the batt in front of or behind the wire; this compresses the insulation and leaves an air gap. Proper Support Wire struts or laced wire can be used to support fiberglass to keep it in touch with the floor above. Wire should not compress the insulation but also should not let it sag. NR-E-I55: Sierra Building Science, Inc. NR-E-IF6: Building America Solutions Center NR-E-IF7: Sierra Building Science, Inc.

R-H-DI1 Envelope INSULATION BLOWN R-E-IC1 NR-E-IB2 Avoid Using Blown Insulation With Metal Framing Blown insulation should not be used with steel framing systems. The best practice for insulating metal framing is to install rigid insulation inside the exterior wall; more detailed information can be found in the section Envelope, INSULATION RIGID / SIPS. Dry Blown Dry blown cellulose can be blown into walls through holes in netting fixed to the studs. The insulation should be packed firmly but not bulging. Rolling the packed insulation helps evenly distribute the cellulose in the stud cavity and leaves it flat ready for drywall installation. NR-E-IB2 Wet Blown Wet blown cellulose is typically used in new construction or major renovations and sticks to the framing to fill the cavity. It is shaved off so that it aligns with the face of the studs. The wall should not be covered until the insulation is totally dry (follow manufacturer instructions for approximate dry times). NR-E-IB3 Spray Open-cell foam sprayed into walls fully fills the stud cavity with no voids. Properly installed foam will not shrink away from framing members. Pay attention to the rim joist area, where blocking and other obstructions, in addition to nozzles used to spray the foam, make it hard to cover the lower edge of that space. Closed cell foam has a higher R value per inch and adds shear strength to the building. Thickness of more than 1.5 inches of closed-cell foam can act as an air and moisture barrier. NR-E-IB4 NR-E-IB1: PLACEHOLDER NR-E-IB2: Baechler, Gilbride, Hefty, Cole, Love NR-E-IB3: Architectural Energy Corporation NR-E-IB4: Baechler, Gilbride, Hefty, Cole, Love

INSULATION BLOWN When Installed in an Unconditioned Space Attic blown insulation should be installed uniformly and reach the outside edge of the exterior walls. Notes:

INSULATION EXTERIOR AND RIGID/ SIPS R-H-DI1 Urea Formaldehyde Foam When using urea formaldehyde foam insulation it may only be installed in exterior side walls. A 4 mil thick plastic polyethylene vapor retarder must separate the foam from the interior space. Code Reference: 2013 Title 24, Part 6 Standards 110.8(b) Metal Framing A wall assembly consisting of exterior veneer, a reflective air space, two inches of R-8 rigid foiled faced insulation, a vapor barrier, exterior gypsum board, topped with metal framing and interior drywall provides a calculated R-value around R-22. This approach prevents the risk moisture infiltration found with fiberglass batt, and allows the stud cavity to more easily be used for electrical and communications wiring. SIPs Structural Insulated Panels sandwich rigid foam insulation between layers of sheathing. Air seal electrical wiring channels in exterior walls. Seal connections between panels, sill and top plates when assembling to reduce water vapor and air transmission. Where appropriate, use SIPs with splines, allowing insulation to remain as continuous as possible. Some panels are produced with rough sawn plywood to speed up installation for board and batt siding. Loading Dock Weather Sealing Reduce air infiltration when loading and unloading at cargo dock doors by using weather seals meant to reduce air flow.

INSULATION EXTERIOR AND RIGID/ SIPS Exterior Insulation Insulation on the exterior of a building must be protected from wind, sun, and moisture as well as maintenance or landscape activities. Brick, stucco and metal siding are examples of cladding that protect exterior wall insulation. Notes:

INSULATION WALL SYSTEMS Concrete Columns Carefully follow the specifications for connection, air sealing and insulation details where concrete columns meet interior and exterior walls. These areas often leave gaps that are difficult to access. Insulating Concrete Forms (ICF) With careful installation and proper air sealing, ICFs can create continuous insulation and an air barrier. Avoid using metal ties to connect the layers of foam to minimize heat transfer through the ICF system.

INSULATION WALL SYSTEMS Notes:

INSULATION ATTIC/ROOF DECK Direct Ceiling Contact Install insulation so that it is in direct contact with roof or ceiling that is continuous and well-sealed to limit infiltration. The insulation may be placed above or below the roof deck, or above the ceiling drywall. Code Reference: 2013 Title 24, Part 6 Standards 110.8(e)1 Roof Membrane Unless the attic insulation has a maximum water absorption of 0.3% by volume, it must be installed below the roof membrane that seals the roof from water penetration. Code Reference: 2013 Title 24, Part 6 Standards 110.8(e)4 Install Entirely Above the Roof Deck Although not a code requirement, rigid insulation installed over a metal roof deck solves several issues associated with attic insulation. It alleviates thermal bridging, creates a very even R value across the entire roof, and covers the metal that otherwise acts as a conduit for heat gain or loss. R-E-IWF3 R-E-IC4

INSULATION ATTIC/ROOF DECK Open Blown or Poured Loose Fill Insulation Loose blown attic insulation should not be installed in attics with greater than a 3:12 sloped ceiling. Otherwise it will be hard to maintain an even full depth over the vaulted area. Notes: Vent Baffles Attic baffles are required in every vented bay. The baffles protect insulation from being blown away from the exterior wall, help maintain the effectiveness of the insulation at its edge, and maintain venting space under the roof deck. Insulating Around Equipment Maintain insulation thickness around equipment installed in the attic. Make sure full insulation depth is maintained above can lights and below ducts. Can lights must be air tight and insulation contact rated. Compressing insulation will reduced effective R value.

INSULATION WALLS/ FOUNDATION More Insulation Less Frame Install wall components to allow for as much insulation coverage as possible while meeting structural requirements. Use two or three stud corners that allow insulation to reach these cavities. Metal Framing Rigid insulation installed over metal studs alleviates thermal bridging of the studs. Cavity insulation between metal studs must be in direct contact with exterior sheathing or rigid insulation if present. Slab Insulation Insulation should extend all the way to the top of the slab.

INSULATION WALLS/ FOUNDATION Notes:

INSULATION - FLOORS Heated Slab Floors A rigid shield is installed at the exposed top edge of insulation to prevent insects from penetrating the wall structure above. Any exposed insulation is protected from moisture, UV, and other damage with a solid covering. Code Reference: 2013 Title 24, Part 6 Standards 110.8(g)2 Heated Slab Insulation Perimeter insulation installed on the exterior of the foundation extends 16" down from the level of the top of the slab; greater if the frost line is deeper. However it may stop at the footing if this is reached first. If the slab is below grade, insulation shall extend from the top of the foundation wall to the bottom of the foundation wall, footing or frost line; whichever is greater. When a heated slab is insulated between the slab and outside wall, the vertical insulation extends from the top of the slab down to the horizontal insulation. The horizontal insulation extends 4' inward from the outside edge of the vertical insulation. Code Reference: 2013 Title 24, Part 6 Standards 110.8-A

INSULATION FLOORS Mass Floors Install continuous rigid insulation under a mass floor so that none of the floor is visible through the insulation.. Steel Joist Floor When insulating a steel joist floor, insulation should be in direct, continuous contact with the floor above. This is most easily achieved with spray on foam insulation. If insulation is not installed for permanent contact, it will lose effectiveness. Wood Framed Floor For full benefits of thermal insulation installed below wood framed floors, the insulation should be in direct contact with the under side of the floor deck. Cantilevers also require that the insulation be blocked in the joist bays above the exterior wall. Notes: