Robust Adaptive Topology Control

Similar documents
REAL-TIME MONITORING AND ASSESSMENT OF CIRCUIT BREAKER OPERATIONS FOR DIAGNOSTICS AND CONTROL APPLICATIONS

Generation Interconnection Feasibility Study Report-Web Version. PJM Generation Interconnection Request Queue Position Z1-055

Improving Market Clearing Software Performance to Meet Existing and Future Challenges MISO s Perspective

Dynamic Thermal Ratings in Real-time Dispatch Market Systems

PJM Seams Update: Day-Ahead M2M Revisions to MISO- PJM Joint Operating Agreement

Dynamic Security Assessment in the Future Grid. Vijay Vittal Ira A. Fulton Chair Professor Arizona State University

Energy Management System (EMS) Model Updates and Quality Assurance (QA)

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

Evolution of Control for the Smart Transmission Grid

Northport - Norwalk Harbor Cable (NNC) Tie line

2013 Ventyx, an ABB company

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

PowerWorld Simulator

How To Operate The Williston Uvls

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

PJM Overview of Markets. Georgian Delegation PUCO Office April 11, 2013

Achieving Operational Efficiencies through On-Line Substation Monitoring. Vince Polsoni Powerstream Inc. Manager Station Sustainment EDIST 2016

Final for ECE374 05/06/13 Solution!!

Generator Interconnection and Deliverability Study Methodology Technical Paper

Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114.

EL PASO ELECTRIC COMPANY (EPE) GENERATOR INTERCONNECTION FEASIBILITY STUDY FOR PROPOSED XXXXXXXX GENERATION ON THE SIERRA BLANCA-FARMER 69 KV LINE

FRCC Coordination Procedure. Title: FRCC Reliability Coordinator Contingency Analysis Monitoring Criteria

This document should be reviewed at least every two years.

The EMSX Platform. A Modular, Scalable, Efficient, Adaptable Platform to Manage Multi-technology Networks. A White Paper.

EARLY EXPERIENCE WITH CLOUD COMPUTING AT ISO NEW ENGLAND

THE COMMISSIONING PROCESS FOR NEW SUBSTATION EQUIPMENT & PROTECTION SCHEMES ON THE BULK ELECTRIC SYSTEM. Lawrence P. Hayes FirstEnergy Corp.

16 West Coast Regional Plan

INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012

Item 8: Houston Import RPG Project

Mladen Kezunovic Texas A&M University

What You Will Learn About. Computers Are Your Future. Chapter 8. Networks: Communicating and Sharing Resources. Network Fundamentals

N-1-1 Contingency Analysis using PowerWorld Simulator

Updated SYSTEM IMPACT STUDY OF NEW ENGLAND AREA

Introduction to PowerWorld Simulator: Interface and Common Tools

Underground vs. Overhead Transmission and Distribution

Voltage Stability Improvement using Static Var Compensator in Power Systems

A. 5MWp SPV Plant at Khimsar, Rajasthan. B. 5MWp SPV Plant Installed Technologies. D. 5MWp SPV Plant Challenges. E. 5MWp SPV Plant - Performance

Wide Area Networks. Learning Objectives. LAN and WAN. School of Business Eastern Illinois University. (Week 11, Thursday 3/22/2007)

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Gi-Joon Nam, IBM Research - Austin Sani R. Nassif, Radyalis. Opportunities in Power Distribution Network System Optimization (from EDA Perspective)

Transmission Planning Standards for the Baltimore Gas & Electric Company Transmission System

data integration/exchange part 2: future technical and business opportunities

TDI's NYC Merchant CHPE Transmission Project with POI at Astoria (NYISO Queue #305) Deliverability Analysis

N.J.A.C. 14:8-4 NET METERING FOR CLASS I RENEWABLE ENERGY SYSTEMS

REQUIREMENTS FOR AUTOMATED FAULT AND DISTURBANCE DATA ANALYSIS

Integration Capacity Analysis Workshop 11/10/15 California IOU s Approach

A progressive method to solve large-scale AC Optimal Power Flow with discrete variables and control of the feasibility

ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe

Safety technique. Emergency stop module BO 5988 safemaster

Energy Management Systems (EMS)

Design of electrical power system for a 1000MW nuclear power generating station

COMMENTS OF THE SOLAR ALLIANCE NEW JERSEY INTERCONNECTION RULES APRIL 29 TH, 2011

Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template

Power transformers. Phase shifting transformers Reliable and efficient power flow control

Integrated Distribution Management System in Alabama

ERCOT Monthly Operational Overview (March 2014) ERCOT Public April 15, 2014

DMS - Breakthrough Technology for the Smart Grid

6. The estimated costs here do not include any applicable ITCC tax

Washington DC Power Sector Overview

IESO Supply Deliverability Guidelines

Bill is the author of 15 papers and lectures on transmission lines and other power system topics.

ECE 358: Computer Networks. Solutions to Homework #4. Chapter 4 - The Network Layer

Cost Benefit Methodology for Optimal Design of Offshore Transmission Systems

HTS Cables: Pitfalls and Potential LIPA Cable Project. J. Maguire American Superconductor. DOE Wire Workshop January, 2007 Panama City, FL

Transmissão em Corrente Contínua em Ultra-Alta Tensão

Record Specification and File Format for Specifying Contingency Definitions and Remedial Actions Schemes

ECE 358: Computer Networks. Homework #3. Chapter 5 and 6 Review Questions 1

Indian Institute of Technology Kharagpur. TCP/IP Part I. Prof Indranil Sengupta Computer Science and Engineering Indian Institute of Technology

Section 4: Scheduling Philosophy & Tools

A Fuzzy Based Solution for Improving Power Quality in Electric Railway Networks

Strategic Microgrid Development for Maximum Value. Allen Freifeld SVP, Law & Public Policy Viridity Energy

Making Ethernet Over SONET Fit a Transport Network Operations Model

Enterprise Approach to OSIsoft PI System

Smart Grid and Renewable Energy Grid Integration. Jian Sun, Professor and Director Department of ECSE & Center for Future Energy Systems

Grid of the Future. Integration of Renewables Energy Storage Smart Grid. Presentation by David Hawkins Lead Renewables Power Engineer Grid Operations

Integrated Power Systems for Data Centers

Note! The problem set consists of two parts: Part I: The problem specifications pages Part II: The answer pages

Voltage Source HVDC Overview Mike Barnes Tony Beddard

Oncor s Pioneering Transmission Dynamic Line Rating (DLR) Demonstration Lays Foundation for Follow-On Deployments

AE64 TELECOMMUNICATION SWITCHING SYSTEMS

Actuator-Sensor-Interface

IEEE Smart Grid Series of Standards IEEE 2030 TM (Interoperability) and IEEE 1547 TM (Interconnection) Status. #GridInterop

Transmission Function Employees Job Titles and Descriptions 18 C.F.R 358.7(f)(1)

Advanced Protection of Distribution Networks with Distributed Generators

SIMULATING HYBRID ENERGY GRIDS IN SMART CITIES FOCUS ON ELECTRIC ENERGY SYSTEMS

Engineering innovation

ASSET MANAGEMENT LCNI 2014 Wednesday 22 nd October. Jennifer Woodruff Innovation & Low Carbon Networks Engineer

The Lagopus SDN Software Switch. 3.1 SDN and OpenFlow. 3. Cloud Computing Technology

PSS E. High-Performance Transmission Planning Application for the Power Industry. Answers for energy.

Development of 10 Gbits/s Traffic Shaper

Standards in Marine Power Systems. APEC 2014 Session IS2.1 Power Electronic Standards Roger Dougal University of South Carolina Columbia, SC 29208

Transcription:

Robust Adaptive Topology Control Mladen Kezunovic, PI Texas A&M University Kory W. Hedman, Co-PI Arizona State University January 14-15, 2015

System Integration Robust Adaptive Topology Control (RATC) adds flexibility to system operations and can be used for a variety of purposes Power Grid Information Technology Optimization RATC Solution Integrated Infrastructure 1

Outline Background - Phase II: Reliability Focus - Objectives and Demonstration - RATC Support Functions, Data Layer and Communications - Learning more about RATC Key Takeaway Points - Corrective RATC and Tool Development - Post-Contingency Corrective Transmission Switching Examples - Results: PJM Test Case - Results: ISONE 2

Phase II: Corrective RATC Post-contingency corrective transmission switching Shortly after a contingency, take a line out of service (as a corrective action) Implement at most 1 corrective switching action But: identify multiple potential switching actions, in advance, per contingency to provide operators choice Perform stability studies to confirm switching actions 3

Objectives Use demonstration example to compare current needs and RATC benefits: AC based HPC multi-core, multi-thread capable Open source Assure topology control: Stability Monitor breaker reliability and associated switching risk Adjust relay settings Have reliable indicators for a need to switch lines Analyze communication requirements 4

Demonstration Example RATC Demonstration Uses PowerData s generic Cascadia model within the PowerSimulator Demonstrates RATC within the Contingency Analysis process using IncSys Training Scenarios 5

RATC Support Functions Relay Mis-operation Detection Fault confirmation Mis-operation detection Circuit Breaker Operation Evaluation Circuit breaker health assessment Relay Setting Coordination Check Relay settings evaluation Relay coordination check 6

RATC Data Layer Supports data flows between RATC components and external data sources Provides reliable data storage and retrieval services Provides API to RATC components to obtain data Based on the Apache Camel Framework RATC Data Layer

Communication Environment Cross-traffic (varied from 0% to 75% of Fractional T-1 capacity) Eth0: 10.10.2.4 H2 Cross Traffic Source H1 Ethernet switch 10.10.2.0 network R1 Ethernet switch 10.10.3.0 network Eth0: 10.10.2.1 Eth1: 10.10.3.1 Test file transfer flow (file size varied from 64KB to 2MB) DummyNet Bridge em0 ep0 Ethernet switch 10.10.3.0 network R2 Eth2: 10.10.3.2 Ethernet switch 10.10.4.0 network Eth0: 10.10.4.1 H6 Cross Traffic - Destination Eth0: 10.10.4.7 Eth0: 10.10.4.6 H3 H4 H5 Eth0: 10.10.2.5 SFTP Source Substation Fractional T-1 experiments rates varied as follows: 64, 128, 256, 384 and 512Kbps Delay: 2 msec Queue size: 100 slots SFTP Data Concentrator RATC Utility File Center RATC Data Layer ActiveMQ Broker Eth0: 10.10.4.8 RATC Component Eth0: 10.10.4.9 Model of RATC system elements: H1 Substation, H3 Control Center (CC) Data Concentrator (RATC Utility File Center), H4 RATC Data Layer, and H5 RATC Component.

Learning more about RATC RATC Learning Opportunities Full RATC Demonstration ARPA-E Technology Showcase Feb 10-11, 2015, Booth 528 RATC User Forum: The ISONE Experience March 12, 2015 @ FERC - 888 First Street, NE, Washington, DC 20426 Full RATC Demonstration Report of RATC performance at ISONE 9

How do I get RATC details? smartgridcenter.tamu.edu/ratc 10

Key Takeaway Points Limited modeling of flexible transmission assets (lines, transformers, FACTS) within EMS & MMS Future EMS and MMS will co-optimize flexible transmission with generation This presentation focuses on postcontingency corrective transmission topology control Future goal: expand to capture FACTS 11

RTCA Tool Development Multi-threaded HPC base AC Power Flow Real-Time Contingency Analysis Package (RTCA) with Corrective Switching Open Source Expanded Dr. Robin Podmore s Open Source AC Power Flow tool to create multi-threaded RTCA package 12

Corrective Switching with Real- Overview Time Contingency Analysis Deliverability test Operator Review Data inputs (AC base case power flow) Perform contingency analysis Corrective RATC Potential violations w/ RATC Yes Potential network violations? No Choose constraints and RATC actions SCED Cost w/ RATC RT approval Repeat Corrective RATC determines corrective transmission switching actions Constraints sent to SCED are reduced; operational costs decrease; reliability maintained 13 13

Example: Pre-Contingency State Subsection of an actual large-scale system All 500 kv buses 14

Post-Contingency State Over voltage situation Contingency All 500 kv buses 15

Post-Contingency State with RATC Topology control solution Over voltage situation eliminated Contingency All 500 kv buses 16

Test Data Source: PJM Tool takes PSS/E.RAW files as inputs 167 PSS/E.RAW input files based on PJM data for testing (7 days) Actual real-time operational snapshots from PJM Network ~15,000 buses; ~20,500 branches; ~2,700 gen; ~1,600 switchable shunts; ~8,900 contingencies 17

Corrective Overview RATC Benefits Tolerance: V violation > 0.005 pu or MVA violation > 5MVA For single corrective switching actions: Number of contingencies with violations outside of tolerance: 4726 (contingencies with violations that are evaluated) # of contingencies where there is NO beneficial corrective switching action: 10 cases: ~0.2% 18 18

(%) RATC-Based Overview RTCA for PJM # of contingencies with violation: 4726 Out of 4726 contingencies with violations (passed to corrective RATC), 52% (2476) of contingencies have no violation with corrective RATC (2nd best candidate: 43%) Out of 4726 contingencies with violations (passed to corrective RATC), 67% (3190) of contingencies have violations within the specified tolerance with corrective RATC Average Statistics 100 80 60 40 Flow Viol. Reduction Volt. Viol. Reduction 20 0 Cand. 1 Cand. 2 Cand. 3 Cand. 4 Cand. 5 Pareto Improvement 19 19

Cost savings ($/hr) Collaboration Overview with ISO-NE Ongoing investigation with ISONE For cases where congestion exists, there has always been a transmission switching action that provides a benefit $140,000 $120,000 $100,000 $80,000 Corrective Switching Savings from removing constraint Savings from corrective switching $60,000 $40,000 $20,000 $- 1 2 3 4 5 6 7 8 9 10 Historical market case 20 20

Questions Contact: Mladen Kezunovic kezunov@ece.tamu.edu, 979-845-7509 Kory W. Hedman khedman@asu.edu, 480-965-1276 21