Master & Amplifier For ModuSat Communal Heating



Similar documents
Metering, Billing & Remote Surveillance. Solutions for Communal Heating Systems - Including SmartTalk Two-Way Communication

OZW30. Central Unit SYNERGYR

Using installed Fieldbus Wiring to carry Ethernet Communications

Temperature & Humidity SMS Alert Controller

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Smile. The All-In-One Heating Controller

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Project Breakdown - Remote Monitoring

Industrial Control Solutions

Electric Flow Boiler

Power Feeding Equipment for Optical Submarine Cable Systems

Aerona Air Source Heat Pumps

For business, corporate and public sector security. Protected premises, protected network

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Metering for today s systems

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

FIREDEX Conventional Fire Panels

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

WEB log. Device connection plans

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Product Information Fire alarm panel 8000 C

JAWAHARLAL NEHRU UNIVERSITY

ABB PSPS Erich Steinmann; Generator control-2013

Voltage Regulator SPAU 341 C. Product Guide

SL42-xx SL42: Smart lighting controllers installation in the pole

PRODUCT LIST Facility DDC Access WebXL DDC

Repeaters and Mimics Data Sheet

Phase Modular Finally the benefits of Modular ups are for all

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Control and Remote Supervision of Sewage Pump Station. AutoLog GSM-RTU and AutoLog ControlMan Web-SCADA Service. Specification V1.

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Bluetooth Web Enabler

Power & Environmental Monitoring

ENAiKOON ultrasonic fuel-level sensor

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Always on the Lookout Perfect Protection against Burglary

Heating Controller. Building Technologies HVAC Products

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

MPR-Systems. Mini Power Racks 1200 W W

Schneider Electric and Energy Efficiency

Permissible ambient temperature Operation Storage, transport

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Vitosoft 200 Vitodata 300 Vitocom 300 Vitocom 100

Standard WIRED Installation Guide

THERMAL MANAGEMENT SOLUTIONS

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

ETL Systems. RSCC Dubna July Global Leaders in Satellite RF Engineering & Custom Build ROUTE AMPLIFY SPLIT SWITCH

API Marine. BMS Presentation. Ballast Measurement Systems

Smart Anytime, Safe Anywhere. Home Passport Gateway-G Series. The Epitome of Smart Living

Table of Contents. TransformerIQ FAQs 1

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Service & Maintenance Packages. Service & After-Sales. A Strong Company

Vehicle IOT Gateway Family Datasheet

Disturbance Recoder SPCR 8C27. Product Guide

Setting Up and Testing the MAX Hardware

SECTION DETECTION AND ALARM

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

User Manual PT-E-HIP

Easy and efficient asset management for your business

NEW. Solar-Log & GE Meter Residential Solar PV Monitoring & Metering Built into a Single Device

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

DSX Master Communications

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

Process Alarm Solutions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Application Briefs: Remote Office Environment

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Rack mounted telephone- and leased line modem for industrial applications

Controller Automation, Model II+

To Purchase This Item, Visit BMI Gaming Operation Manual

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f

User Manual (UDTTV01 V 1.6

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

IRIS Touch 600 Range Dialler Installation Manual. Version 1.3

3500/93 System Display

Seeing by Degrees: Programming Visualization From Sensor Networks

Improve competiveness of IDC and enterprise data centers with DCIM

IBS IP I/O Gateway. Data Sheet INTERBUS-S. Coupling Module for Two InterBus-S Lines

Bristol ControlWave Redundant Control

Square D Powerlink G3 Lighting Control Systems

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Telephone- and leased line modem for industrial applications TD-36

Advanced Transportation Management Systems

Smart House And Home Automation Technologies

Transcription:

Master The ModuSat master controller provides a convenient central point for connection of all ModuSat HIU S on a communal heating scheme. The ModuSat s and master are linked via a hard wired Modbus RS485 network or a GPRS virtual Bus network. This enables our SmartTalk two way communication system to deliver instant downloads of billing and consumption data, end user assistance including operation of individual units remotely and uploading of software upgrades. The master is available in 6 standard sizes:- 1-4 Modules 1 Connection of up to 160 ModuSat Units 2 Connection of up to 320 ModuSat Units 3 - Connection of up to 480 ModuSat Units 4 - Connection of up to 640 ModuSat Units 5-6 Modules 5 - Connection of up to 800 ModuSat Units 6 - Connection of up to 960 ModuSat Units (Details of the cabinet sizes for the above master models are detailed on the following page) Master Features & Benefits Up to 960 ModuSat HIU s / Meters can be connected to a single master panel Either Mobile GPRS or Broadband connection to central supervisor IP65 rated enclosure in 2 standard size formats. Simple screw down terminal connections Amplifier improves signal integrity for long cable runs. Enables the system in each apartment to be fully controlled remotely, including timings and settings, and provides remote diagnostic capability and client support Remote operation of each unit via master panel aids commissioning process and facilitates the fast upload and download of data Fault alarms can be checked by testing the operation of components Empty apartments can be monitored and controlled without the need to visit site for example un-sold or un-let properties can be left on frost protection and if the unit is sold or let or simply has a viewing then the heating can be turned on from the management office Online control facility allows occupiers to set heating and hot water remotely and view consumption using any web enabled device Avoids unnecessary call-outs as a result of user error Data logging of apartment temperatures Improved data integrity and upload and download speeds Amplifier ensures signal continuity is maintained within the network Amplifier simplifies the identification of any network issues by subdividing the network down in sections Amplifier Evinox Ltd T. +44 (0)1372 722277 E. technical@evinox.co.uk W. www.evinox.co.uk 2551431C 1

Master Master & Amplifier Dimensions - Master with 1-4 Modules FRONT VIEW SIDE VIEW 500 260 TOP VIEW 410 13.5 25 600 35 96 SECTION B-B Dimensions - Master with 5-6 Modules FRONT VIEW SIDE VIEW 500 260 TOP VIEW 410 13.5 700 25 35 96 Note: All units are to have a static IP address for Broadband connection. 2

Master Connection Details The master can be connected to a remote main supervisor either via a broadband connection with static IP or with an optional GPRS modem using a mobile connection with a sim card. If the master is supplied with the optional GPRS modem, this has the facility to be fitted with 2 sim cards, which the modem will switch between to ensure continuous operation on the mobile network, providing the strongest signal at any given time. The master controller also includes connections for monitoring the primary flow and return temperatures within the plantroom and features connection of an external temperatures sensor. External temperatures can be uploaded to each individual HIU to enable the units to operate with weather compensation. The master controller has provision for boiler volt free control via a 0-10 volt signal and alarm inputs / outputs, which can be programmed for a number of various requirements to suit the specific requirements of the scheme. Typical Master Control Panel (1 Controller) 3

Typical Master Control Panel (2 Controllers) 4

Typical Master Control Panel (3-6 Controllers) 5

Amplifier Master & Amplifier The amplifier ensures that the signal continuity is maintained within the network and also simplifies the identification of network issues by subdividing the network down in sections of 32 dwellings / ModuSat s. Dimensions FRONT VIEW SIDE VIEW REAR VIEW 300 120 260 200 TOP VIEW 120 160 The Amplifiers are connected to the master typically in a daisy chain format and these allow for connection of 2 legs of 16 apartments up to a total of 32 apartments / ModuSats per amplifier. Typical Wiring Detail for Amplifier 6

System Master & Amplifier Typical System Architecture Evinox Ltd T. +44 (0)1372 722277 E. technical@evinox.co.uk W. www.evinox.co.uk 2551431A 7