ENTERPRISE FIBER OPTIC CABLE. Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore

Similar documents
Fiber Optic Cable

Fibre optic cables MDIC LSZH

Industry solutions: Broad cast

DATA CENTER PRODUCTS. Fiber Optic Cable Optical Connectivity Fiber Management Test & Inspection Fusion Splicers

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

Fibre Optic Cable. Catalogue.

Fiber Optics in Harsh Environment Applications

Fiber Optic Cordage. Interconnect A Furukawa Company. Product Description. Why OFS Interconnect Cordage?

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Fibre Optic Indoor/Outdoor Cable

Reliable, Consistent, Quality

Optical Fibers Fiber Optic Cables Indoor/Outdoor

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

288 Fiber Ultra-High Fiber Density Micro-Duct Cable with Extreme Operating Performance

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

KGP Logistics Outside Plant Catalog

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

home site map help ECMS Project: Standard / Federal Oversight Advertised

Plug & Play Universal Systems

ESPECIFICACIÓN DE PRODUCTO

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Procedure for Cutting and Respooling Fiber Optic Cable

fiberopt Whirlwind Fiber Optic Solutions product guide Ling Rd. Rochester, NY whirlwindusa. com

GOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

FIBER OPTIC Cables. Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables

Patch Cords for Data Center Applications

GOSN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

OPTICAL FIBRE CABLE APPLICATIONS GUIDELINES

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

Corning Cable Systems is EXPANDING OPPORTUNITIES

Outside Telephone Cable

Cable Assemblies. Corning Cable Systems

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment

part number number Description B96551 M96551 Tactical, All Dielectric Cable, Tight Buffer, Oudoor, Multimode OM1, 62.5 µm, 4 fibers B96566 M96566

New Wiring Technology for Cost-effective Construction of FTTH Networks Using Free Branch Cable

CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES

ALL-DIELECTRIC LOOSE TUBE FIBER OPTIC CABLE

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

SPECIALTY FIBER OPTIC CABLE. Downhole Sensing Subsea

SECTION FIBER OPTIC CABLE AND ACCESSORIES

Fiber Optic Cable Products. Leading Solution

P URCHASING D IVISION

FIBER-OPTIC CABLES LWL-KABEL

SINGLE MODE OPTICAL FIBER FTTH CABLE

hot products guide people. passion. expertise. gocsc.com

Communication, Signal & Data Cables

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

The following terms are defined within the context of the fiber optic industry

P URCHASING D IVISION

APR 2016 Rev M

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

industry solutions: Security

OPTICAL FIBER CABLES

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

Sumitomo. Data Center. Carrier Hotel. 4 th Level Network Solutions. DataCom. networks. Optical Fiber Infrastructure Guide

EXAMPLE OF RELEVANT STANDARDS

Fiber Optic Specifications

SECURE Fiber Optic Products

Indoor/Outdoor Tight-Buffered Cable Lowers Installation Costs, Reduces Time, and Increases Reliability

Cable Preparation and Pulling Procedure Best Practices for Fiber Optic Indoor Tight-Buffered Cable

QuickSpecs. HPE OfficeConnect 1410 Switch Series. Overview. HPE OfficeConnect 1410 Switch Series. Models. Key features.

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

LANscape Solutions Fiber Optic Products Catalog

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

SPECIALTY FIBER OPTIC CABLE. Downhole Subsea Sensing Equipment

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

Gulf Cable & Electrical Ind. Co.

AERIAL FIBER OPTIC CABLE PLACEMENT

FTTx Optical Fiber Cable for Easy Mid-Span Access ( EZremove )

Polymer Coated Fiber Cable (PCF)

Broadcast and Commercial AV Cabling MASTER CATALOG

SINGLE MODE OPTICAL FIBER CABLE

LANscape Solutions for Xcelerated Bandwidth Applications LANscape Xcelerate and Xcelerate Plus Solutions

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

200-Micron Single-Mode Fiber Enables New Cable Designs Copyright 2014 OFS FITEL, LLC

Types of Optic Cable andApplications

7.4 3M No Polish Connector

Guidelines for Installation of Fiber Optic Cables

Pretium EDGE HD Solutions

MarineTuff Offshore and Marine Cable Solutions

Fiber-to-the-Home/FTTH

BICSInews. plus. Show Issue. september/october 2012 volume 33, number 5. + Migration to High-Speed Ethernet

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

Guide to Patch Cords. and Pigtails.

Specification SFTP CAT6 Network Cable 23AWG CU

ETHERLINE Ethernet Cable, Connectors & Tools

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

Cable Assembly Solutions at the Speed of Light

FIBER OPTIC CABLE PRODUCTS. CommScope Fiber Optic Cable Products

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

2014 Fiber Optic Cable for the Nuclear Power Industry

Section kv Power Cables

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

Uniprise Solutions. Information Security Network Solutions

SPECIFICATION STANDARD OPTICAL FIBER BACKBONE CABLING

Transcription:

ENTERPRISE FIBER OPTIC CABLE Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore

Founded in 1984, AFL is a global leader providing fiber optic products, equipment, and engineering services to the telecommunications, electric utility, wireless, energy, private network and OEM markets. AFL also serves a diverse mix of industry segments that include service providers, military and defense, mining, oil and gas, and biomedical. AFL brings years of experience in developing solutions for customers, fostering a creative culture to drive and deploy innovative technologies that will improve communications for years to come. Our product line consists of fiber optic cable, transmission and substation accessories, outside plant equipment, connectors, fusion splicers, test equipment and training. AFL s service portfolio includes market-leading positions with the foremost communications companies supporting inside plant central office, EF&I, outside plant, enterprise and wireless areas. AFL is dedicated to bringing our customers a quality product as well as delivering superior value.

Table of Contents Specifying AFL Premise Optical Cables.... 3 OSP Loose Tube Cable Gel-Filled Non-Armored OSP Loose Tube (LE Series SJ)... 4 Non-Armored Loose Tube Cable Double Jacket (LE Series DJ)... 6 Single-Jacket Single-Armor OSP Loose Tube (LE Series SASJ)... 8 Double-Jacket Single-Armor OSP Loose Tube (LE Series SADJ)... 10 All-Dielectric Armored Rodent-Resistant OSP Loose Tube (LN Series).... 12 Uniflex Non-Armored Loose Tube Cable.... 14 Uniflex Armored Loose Tube Cable... 15 Heavy Duty Uniflex Loose Tube Cable... 16 OSP Loose Tube Cable Gel-Free Wrapping Tube Cable (WTC) with SWR... 17 Gel-Free Non-Armored OSP Loose Tube (LE Series Gel-Free SJ)... 19 Gel-Free Single-Jacket Single-Armor OSP Loose Tube (LE Series Gel-Free SASJ).... 21 Gel-Free Double-Jacket Single-Armor OSP Loose Tube (LE Series Gel-Free SADJ)... 23 Indoor/Outdoor Loose Tube Cable Gel-Filled Riser Single-Jacket I/O Loose Tube (LV Series SJ).... 25 Indoor/Outdoor Loose Tube Cable Gel-Free Gel-Free Riser Non-Armored Loose Tube (LV Series Gel-Free SJ)... 27 Gel-Free Riser Single-Jacket Single-Armor Loose Tube (LV Series Gel-Free SASJ).... 29 LSZH Single-Armor Single-Jacket I/O Loose Tube (LL Series SASJ)...31 Listed Gel-Free, LSZH, Loose Tube Cable (LL Series).... 33 Extreme Low Temp LSZH Double Jacket I/O Loose Tube (LA Series)... 35 Gel-Free Extreme Low Temp LSZH Double Jacket I/O Loose Tube (LA Series Gel-Free)... 37 XLPO LSZH Double-Jacket I/O Loose Tube (LX Series).... 39 MicroCore Cable OSP MicroCore Telcordia GR-20 Micro-Technology Air-Blown Loose Tube Cable.... 41 FTTx MicroDrop Cable... 43 OSP MicroCore Composite Cable eabf Solutions... 44 eabf Products... 45 Interconnect Premise MicroCore Cable... 46 Simplex Cable... 48 Zipcord, Dual-link and Micro-Dual Cable.... 50 250 µm Fan-out (Furcation) Tubing... 52 RIBBON-Link Cable... 54 Indoor Cable Fiber-In-A-Box... 56 QUAD-link and Circular Premise Cable... 57 Multi-Unit Circular Premise Cable... 59 Low Smoke Zero Halogen Distribution Cable.... 61 Interlocking Armor Technology... 63 Armored Tight Buffered Circular Premise Cable... 65 Sub-unitized Premise MicroCore Cable... 67 12-144F Sub-unitized Premise MicroCore 2.0...............69 Sub-unitized Premise MicroCore 3.0 with SpiderWeb Ribbon Technology.... 71 Breakout Cable... 73 Indoor/Outdoor Cable Indoor/Outdoor Low Smoke Zero Halogen Breakout Cable... 75 Indoor/Outdoor Riser Tight Buffered Cable... 77 Indoor/Outdoor Multi-unit Riser Tight Buffered Cable... 79 Indoor/Outdoor Plenum Distribution Cable... 81 Indoor/Outdoor Breakout Cable... 83 Ruggedized Indoor/Outdoor Breakout Cable.... 85 continued on the next page 3.8.16 1

Tactical Cable Tactical Tight Buffered Cable... 87 Broadcast Deployable Tight Buffered Cable.... 89 Composite Cable Copper/Fiber Composite Cable.... 90 All-Dielectric Self Supporting (ADSS) Cable Mini-Span ADSS Cable... 92 Flex-Span ADSS Fiber Optic Cable... 98 All-Dielectric Self Supporting Cable Accessories Mini-Dead Ends.... 102 Mini-Bracket.... 103 Mini Formed Wire Tangent Support (FTS)... 103 Wedge Dead End.... 104 Limited Tension Formed Wire Dead End for ADSS Cable... 105 Medium Tension Dead End for ADSS Cable... 106 Semi-High Tension Dead End for ADSS Cable.... 107 Trunnion Assemblies.... 108 ADSS Suspension Unit.... 109 Formed Wire Suspension for ADSS Cable.... 110 Wood Pole Guide Clamp for ADSS Cable.... 111 Spiral Vibration Damper for ADSS or OPGW Cable.... 113 Fiber Storage Units for ADSS Fiber Optic Cable.... 114 Fiber Optic Training Light Brigade Fiber Optic Training... 115 Certification Options... 116 Custom Fiber Optic Training... 117 3.8.16 2

Specifying AFL Premise Optical Cables Cable Type Jacket Type Fiber Count Fiber Type* Unit Jacket Diameter Print Jacket Color Tight Buffer Color Tight Buffer Type Additional Information* C R 012 5 55 1 0 0 1 AIA B = Breakout C = Circular Premise Cable D = Dual-link G = Sub-unitized Microcore K = Indoor/Outdoor S = Simplex U = Quad-link W = Ribbon X = Tactical Z = Zipcord R = Riser P = Plenum E = LSZH U = Polyurethane F = Furcation B = Bare 004 = 4 fiber 006 = 6 fiber 012 = 12 fiber etc. 5 = 50 µm MM 6 = 62.5 µm MM 9 = Single-mode L = 10G 300 m K = Bend-Insensitive SM * more available 55 = 5.5 mm 1 = AFL standard 2 = Non-standard U = Unprinted 0 = Standard 1 = Blue 2 = Orange 3 = Green 4 = Brown 5 = Slate 6 = White 7 = Red 8 = Black 9 = Yellow A = Violet B = Rose C = Aqua 0 = Standard 1 = Standard Strip 3 = EZ strip 6 = 600 µm Tight Buffer 8 = Medium Strip B = Bare G = Elastomer over 250 µm H = Elastomer over 500 µm U = 500 µm Bare Fiber AIA = Aluminum Interlocking Armor AIAR = Aluminum Interlocking Armor/Riser Jacket AIAP = Aluminum Interlocking Armor/Plenum Jacket or other customer specific information * * Different configurations, fiber types, etc. may be available. Please consult your AFL representative for more details. Cable Print Examples AFL OPTICAL CABLE 1-800-AFL-FIBER AFL Standard Print AFL OPTICAL CABLE 1-800-AFL-FIBER 50/125 12 FIBER (UL) TYPE OFNR c(ul) RoHS MM/YY OOOOOO METERS REEL NUMBER Generic Print OPTICAL FIBER CABLE 50/125 12 FIBER E121250 TYPE OFNR (UL) c(ul) RoHS-COMPLIANT MM/YY OOOOOO METERS REEL NUMBER * Custom print is available. Icon Legend A AFL can add Interlocking Armor to any type of fiber optic cable. Fiber optic cable that is approved for mining applications. AFL stocks many of our most popular cables for your convenience. Please contact us at 800-AFL-FIBER or AFLPremiseStock@AFLGlobal.com for more details. A 3 2008, AFL, all rights reserved. PP-1-00064, Revision 2, 12.14.15

Non-Armored OSP Loose Tube (LE Series SJ) Acting as the backbone for most of today s fiber based systems, stranded fiber optic cables play a critical role in the high speed network. AFL s Non-Armored Loose Tube fiber optic cables are designed to provide high fiber counts with the flexibility and versatility required for today s most demanding installations. With fiber counts up to 576 and S-Z strand designs for easy mid-span access, AFL s cables comply with EIA/TIA, REA/RUS PE-90 and GR-20. Industry standard designs combined with innovative technologies, such as a dry core product, yield a world class cable that will support today s and tomorrow s technological needs. Cable Components Product Applications Long Haul Networking Building Interconnections (Campus LAN) Trunking Lines Direct to Telecommunications Closet Local Loop Distance Learning Distribution Intrabuilding Backbones Temperature Specifications TEMPERATURE RANGE INSTALLATION -30ºC to +70ºC OPERATING -40ºC to +70ºC STORAGE -40ºC to +75ºC Typical Lengths MAXIMUM LENGTHS* FIBER SINGLE-MODE MULTIMODE COUNT FEET METERS FEET METERS 6-60 22,900 7,000 22,900 7,000 72-96 22,900 7,000 22,900 7,000 108-120 22,900 7,000 22,900 7,000 132-144 22,900 7,000 22,900 7,000 146-216 22,900 7,000 22,900 7,000 218-288 16,400 5,000 16,400 5,000 290-432 14,100 4,300 14,000 4,300 434-576 10,800 3,300 11,000 3,300 * Longer lengths may be available upon request. Fiber Specifications MAXIMUM ATTENUATION (DB/KM) OVERFILL LAUNCH MIN. BANDWIDTH (MHZ KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM (6) 62.5/125 GIGA-Link 300 3.5 1.2 N/A N/A 200 600 300 550 (5) 50/125 GIGA-Link 600 2.9 0.9 N/A N/A 500 500 600 600 (L) 50/125 Laser-Link 300 2.9 0.9 N/A N/A 1500 500 900 550 (9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 (Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A (K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 Gigabit Ethernet Minimum Link Distances are based on bandwidth /modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. 4 2002, AFL, all rights reserved. PP-1-00016, Revision 6, 12.14.15

Non-Armored OSP Loose Tube (LE Series SJ) Ordering Information NOMINAL NOMINAL MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS FIBER NUMBER OF DIAMETER WEIGHT LBS (N) INCHES (CM) AFL NO. COUNT TUBES/FIBERS INCHES MM LBS/1,000FT KG/KM SHORT TERM LONG TERM SHORT TERM LONG TERM LE006 C5101N1 6 1w/6 (4 fillers) 0.41 10.5 56 83 600 (2670) 200 (890) 8.2 (21) 4.1 (11) LE012 C5101N1 12 1w/12 (4 fillers) 0.41 10.5 56 84 600 (2670) 200 (890) 8.2 (21) 4.1 (11) LE018 C5101N1 18 1w/12,1w/6 (3 fillers) 0.41 10.5 57 85 600 (2670) 200 (890) 8.2 (21) 4.1 (11) LE024 C5101N1 24 2w/12 (3 fillers) 0.41 10.5 57 85 600 (2670) 200 (890) 8.2 (21) 4.1 (11) LE030 C5101N1 30 2w/12,1w/6 (2 fillers) 0.41 10.5 58 86 600 (2670) 200 (890) 8.2 (21) 4.1 (11) LE036 C5101N1 36 3w/12 (2 fillers) 0.41 10.5 58 86 600 (2670) 200 (890) 8.2 (21) 4.1 (11) LE048 C5101N1 48 4w/12 (1 filler) 0.41 10.5 59 87 600 (2670) 200 (890) 8.2 (21) 4.1 (11) LE060 C5101N1 60 5w/12 (no fillers) 0.41 10.5 60 89 600 (2670) 200 (890) 8.2 (21) 4.1 (11) LE072 C6101N1 72 6w/12 (no fillers) 0.45 11.5 71 106 600 (2670) 200 (890) 9.0 (22) 4.5 (11.5) LE084 C8101N1 84 7w/12 (1 filler) 0.52 13.3 90 135 600 (2670) 200 (890) 10.4 (27) 5.2 (14) LE096 C8101N1 96 8w/12 (no fillers) 0.52 13.3 91 136 600 (2670) 200 (890) 10.4 (27) 5.2 (14) LE108 CA101N1 108 9w/12 (1 filler) 0.59 15.1 117 174 600 (2670) 200 (890) 11.8 (31) 5.9 (16) LE120 CA101N1 120 l0w/12 (no fillers) 0.59 15.1 118 175 600 (2670) 200 (890) 11.8 (31) 5.9 (16) LE132 CC101N1 132 11w/12 (1 filler) 0.67 17.0 147 219 600 (2670) 200 (890) 13.4 (34) 6.7 (17) LE144 CC101N1 144 12w/12 (no fillers) 0.67 17.0 148 220 600 (2670) 200 (890) 13.4 (34) 6.7 (17) LE216 CI301N1 216 18w/12 (no fillers) 0.69 17.4 150 224 600 (2670) 200 (890) 14.0 (35) 6.9 (18) LE288 CO301N1 288 24w/12 (no fillers) 0.79 20.1 202 301 600 (2670) 200 (890) 17.3 (41) 7.9 (21) LE432 IO301N1 432 24w/18 (no fillers) 0.87 22.0 242 360 600 (2670) 200 (890) 17.4 (44) 8.7 (22) LE576 OO301N1 576 24w/24 (no fillers) 1.00 25.3 319 475 600 (2670) 200 (890) 20.1 (51) 10.2 (26) Note: Diameter and weight subject to change without notice Fiber Types Replace asterisk ( ) in AFL number with number in the Fiber Specifications table on previous page. Reel Information REEL A REEL B REEL C REEL D REEL E ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4 Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6 Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4 Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9 Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9 Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request. Larger reel sizes may be required to accomodate long cable lengths. 5 2002, AFL, all rights reserved. PP-1-00016, Revision 6, 12.14.15

Product Applications Long Haul Networking Building Interconnections (Campus LAN) Trunking Lines Direct to Telecommunications Closet Local Loop Distance Learning Distribution Intrabuilding Backbones Non-Armored Loose Tube Cable Double Jacket (LE Series DJ) Acting as the backbone for most of today s fiber based systems, stranded fiber optic cables play a critical role in the high speed network. AFL s Non-Armored Double Jacket Loose Tube fiber optic cables are designed to provide high fiber counts with the flexibility and versatility required for today s most demanding installations while incorporating a second jacket when extra mechanical protection is desired. With fiber counts up to 576 and S-Z strand designs for easy mid-span access, AFL s cables comply with EIA/TIA, REA/RUS PE-90 and GR-20. Industry standard designs combined with innovative technologies, such as a dry core product, yield a world class cable that will support today s and tomorrow s technological needs. Cable Components Temperature Specifications TEMPERATURE RANGE INSTALLATION -30ºC to +70ºC OPERATING -40ºC to +70ºC STORAGE -40ºC to +75ºC Typical Lengths MAXIMUM LENGTHS* FIBER SINGLE-MODE MULTIMODE COUNT FEET METERS FEET METERS 6-60 22,900 7,000 22,900 7,000 72-96 22,900 7,000 22,900 7,000 108-120 22,900 7,000 22,900 7,000 132-144 22,900 7,000 22,900 7,000 146-216 17,000 5,200 17,000 5,200 218-288 15,000 4,600 15,000 4,600 290-432 10,800 3,300 10,800 3,300 434-576 6,500 2,000 6,500 2,000 * Longer lengths may be available upon request. Fiber Specifications MAXIMUM ATTENUATION (DB/KM) OVERFILL LAUNCH MIN. BANDWIDTH (MHZ KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM (6) 62.5/125 GIGA-Link 300 3.5 1.2 N/A N/A 200 600 300 550 (5) 50/125 GIGA-Link 600 2.9 0.9 N/A N/A 500 500 600 600 (L) 50/125 Laser-Link 300 2.9 0.9 N/A N/A 1500 500 900 550 (9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 (Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A (K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 Gigabit Ethernet Minimum Link Distances are based on bandwidth /modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. 6 2002, AFL, all rights reserved. PP-1-00015, Revision 5, 12.14.15

Non-Armored Loose Tube Cable Double Jacket (LE Series DJ) Ordering Information NOMINAL NOMINAL MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS FIBER NUMBER OF DIAMETER WEIGHT LBS (N) INCHES (CM) AFL NO. COUNT TUBES/FIBERS INCHES MM LBS/1,000FT KG/KM SHORT TERM LONG TERM SHORT TERM LONG TERM LE006 C5111N1 6 1w/6 (4 fillers) 0.49 12.5 79 118 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LE012 C5111N1 12 1w/12 (4 fillers) 0.49 12.5 80 119 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LE018 C5111N1 18 1w/12,1w/6 (3 fillers) 0.49 12.5 81 120 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LE024 C5111N1 24 2w/12 (3 fillers) 0.49 12.5 81 120 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LE030 C5111N1 30 2w/12,1w/6 (2 fillers) 0.49 12.5 82 121 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LE036 C5111N1 36 3w/12 (2 fillers) 0.49 12.5 82 121 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LE048 C5111N1 48 4w/12 (1 filler) 0.49 12.5 83 123 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LE060 C5111N1 60 5w/12 (no fillers) 0.49 12.5 84 125 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LE072 C6111N1 72 6w/12 (no fillers) 0.53 13.4 97 144 600 (2670) 200 (890) 10.6 (27) 5.3 (14) LE084 C8111N1 84 7w/12 (1 filler) 0.60 15.2 120 178 600 (2670) 200 (890) 12.0 (31) 6.0 (16) LE096 C8111N1 96 8w/12 (no fillers) 0.60 15.2 121 180 600 (2670) 200 (890) 12.0 (31) 6.0 (16) LE108 CA111N1 108 9w/12 (1 filler) 0.67 17.1 150 222 600 (2670) 200 (890) 13.4 (34) 6.7 (17) LE120 CA111N1 120 10w/12 (no fillers) 0.67 17.1 151 224 600 (2670) 200 (890) 13.4 (34) 6.7 (17) LE132 CC111N1 132 11w/12 (1 filler) 0.75 19.0 184 273 600 (2670) 200 (890) 15.0 (38) 7.5 (19) LE144 CC111N1 144 12w/12 (no fillers) 0.75 19.0 185 275 600 (2670) 200 (890) 15.0 (38) 7.5 (19) LE216 CI311N1 216 18w/12 (no fillers) 0.76 19.3 188 280 600 (2670) 200 (890) 15.2 (39) 7.6 (20) LE288 CO311N1 288 24w/12 (no fillers) 0.87 22.0 245 365 600 (2670) 200 (890) 17.4 (44) 8.7 (22) LE432 IO311N1 432 24w/18 (no fillers) 0.94 23.9 289 430 600 (2670) 200 (890) 18.8 (48) 9.4 (24) LE576 OO311N1 576 24w/24 (no fillers) 1.08 27.3 372 554 600 (2670) 200 (890) 21.4 (55) 10.7 (28) Note: Diameter and weight subject to change without notice Fiber Types Replace asterisk ( ) in AFL number with number in the Fiber Specifications table on previous page. Reel Information REEL A REEL B REEL C REEL D REEL E ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4 Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6 Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4 Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9 Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9 Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request. Larger reel sizes may be required to accomodate long cable lengths. 7 2002, AFL, all rights reserved. PP-1-00015, Revision 5, 12.14.15

Single-Jacket Single-Armor OSP Loose Tube (LE Series SASJ) Acting as the backbone for most of today s fiber based systems, stranded fiber optic cables play a critical role in the high speed network. AFL s Armored Loose Tube Single Jacket/Single Armor fiber optic cables are designed to provide high fiber counts with the flexibility and versatility required for today s most demanding installations, including direct buried. With fiber counts up to 288 and S-Z strand designs for easy mid-span access, AFL s cables comply with EIA/TIA, REA/RUS PE-90 and GR-20. Industry standard designs combined with innovative technologies, such as a dry core product, yield a world class cable that will support today s and tomorrow s technological needs. Product Applications Long Haul Networking Building Interconnections (Campus LAN) Trunking Lines Direct to Telecommunications Closet Local Loop Distance Learning Distribution Intrabuilding Backbones Cable Components Polyethylene outer jacket Optical fiber Gel-filled loose buffer tube Corrugated steel armoring FRP central member Ripcord Water-blocking system Temperature Specifications TEMPERATURE RANGE INSTALLATION -30ºC to +70ºC OPERATING -40ºC to +70ºC STORAGE -40ºC to +75ºC Typical Lengths MAXIMUM LENGTHS* SINGLE-MODE MULTIMODE FIBER COUNT FEET METERS FEET METERS 6-288 19,686 6,000 19,686 6,000 * Longer lengths may be available upon request. Fiber Specifications MAXIMUM ATTENUATION (DB/KM) OVERFILL LAUNCH MIN. BANDWIDTH (MHZ KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM (6) 62.5/125 GIGA-Link 300 3.5 1.2 N/A N/A 200 600 300 550 (5) 50/125 GIGA-Link 600 2.9 0.9 N/A N/A 500 500 600 600 (L) 50/125 Laser-Link 300 2.9 0.9 N/A N/A 1500 500 900 550 (9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 (Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A (K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 Gigabit Ethernet Minimum Link Distances are based on bandwidth /modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. 2002, AFL, all rights reserved. PP-1-00004, Revision 8, 12.14.15 8

Single-Jacket Single-Armor OSP Loose Tube (LE Series SASJ) Ordering Information NOMINAL NOMINAL MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS DIAMETER WEIGHT LBS (N) INCHES (CM) AFL NO. FIBER COUNT NUMBER OF TUBES/FIBERS INCHES MM LBS/1,000FT KG/KM SHORT TERM LONG TERM SHORT TERM LONG TERM LE006 C5201S1 6 1w/6 (4 fillers) 0.52 13.3 102 152 600 (2670) 200 (890) 10.7 (28) 5.4 (14) LE012 C5201S1 12 1w/12 (4 fillers) 0.52 13.3 102 152 600 (2670) 200 (890) 10.7 (28) 5.4 (14) LE018 C5201S1 18 1w/12,1w/6 (3 fillers) 0.52 13.3 103 153 600 (2670) 200 (890) 10.7 (28) 5.4 (14) LE024 C5201S1 24 2w/12 (3 fillers) 0.52 13.3 103 154 600 (2670) 200 (890) 10.7 (28) 5.4 (14) LE030 C5201S1 30 2w/12,1w/6 (2 fillers) 0.52 13.3 104 155 600 (2670) 200 (890) 10.7 (28) 5.4 (14) LE036 C5201S1 36 3w/12 (2 fillers) 0.52 13.3 104 155 600 (2670) 200 (890) 10.7 (28) 5.4 (14) LE048 C5201S1 48 4w/12 (1 filler) 0.52 13.3 105 157 600 (2670) 200 (890) 10.7 (28) 5.4 (14) LE060 C5201S1 60 5w/12 (no fillers) 0.52 13.3 106 158 600 (2670) 200 (890) 10.7 (28) 5.4 (14) LE072 C6201S1 72 6w/12 (no fillers) 0.56 14.2 120 179 600 (2670) 200 (890) 11.4 (29) 5.7 (15) LE084 C8201S1 84 7w/12 (1 filler) 0.63 16.0 146 218 600 (2670) 200 (890) 12.8 (33) 6.4 (16.3) LE096 C8201S1 96 8w/12 (no fillers) 0.63 16.0 147 219 600 (2670) 200 (890) 12.8 (33) 6.4 (16.3) LE108 CA201S1 108 9w/12 (1 filler) 0. 70 17.8 176 262 600 (2670) 200 (890) 14.2 (37) 7.1 (18) LE120 CA201S1 120 10w/12 (no fillers) 0. 70 17.8 177 264 600 (2670) 200 (890) 14.2 (37) 7.1 (18) LE132 CC201S1 132 11w/12 (1 filler) 0. 78 19.7 213 317 600 (2670) 200 (890) 15.7 (40) 7.9 (20) LE144 CC201S1 144 12w/12 (no fillers) 0. 78 19.7 214 319 600 (2670) 200 (890) 15.7 (40) 7.9 (20) LE192 O8201S1 192 8 w/24 (no fillers) 0.63 16.0 152 226 600 (2670) 200 (890) 12.8 (33) 6.4 (163) LE288 OC201S1 288 12 w/24 (no fillers) 0.78 19.7 219 326 600 (2670) 200 (890) 15.7 (40) 7.9 (20) Note: Diameter and weight subject to change without notice Fiber Types Replace asterisk ( ) in AFL number with number in the Fiber Specifications table on previous page. Reel Information REEL A REEL B REEL C REEL D REEL E ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4 Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6 Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4 Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9 Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9 Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request. Larger reel sizes may be required to accomodate long cable lengths. 2002, AFL, all rights reserved. PP-1-00004, Revision 8, 12.14.15 9

Double-Jacket Single-Armor OSP Loose Tube (LE Series SADJ) Acting as the backbone for most of today s fiber based systems, stranded fiber optic cables play a critical role in the high speed network. AFL s Armored Loose Tube Double Jacket/Single Armor fiber optic cables are designed to provide high fiber counts with the flexibility and versatility required for today s most demanding installations, including direct buried. With fiber counts up to 312 and S-Z strand designs for easy mid-span access, AFL cables comply with EIA/TIA, REA/RUS PE-90 and GR-20. Industry standard designs combined with innovative technologies, such as a dry core product, yield a world class cable that will support today s and tomorrow s technological needs. Product Applications Long Haul Networking Building Interconnections (Campus LAN) Trunking Lines Direct to Telecommunications Closet Local Loop Distance Learning Distribution Intrabuilding Backbones Cable Components Temperature Specifications TEMPERATURE RANGE INSTALLATION -30ºC to +70ºC OPERATING -40ºC to +70ºC STORAGE -40ºC to +75ºC Typical Lengths MAXIMUM LENGTHS* SINGLE-MODE MULTIMODE FIBER COUNT FEET METERS FEET METERS 6-72 20,000 6,000 20,000 6,000 84-96 14,700 4,500 14,700 4,500 108-120 13,000 4,000 13,000 4,000 132-144 11,100 3,400 11,100 3,400 146-312 10,000 3,000 10,000 3,000 * Longer lengths may be available upon request. Fiber Specifications MAXIMUM ATTENUATION (DB/KM) OVERFILL LAUNCH MIN. BANDWIDTH (MHZ KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM (6) 62.5/125 GIGA-Link 300 3.5 1.2 N/A N/A 200 600 300 550 (5) 50/125 GIGA-Link 600 2.9 0.9 N/A N/A 500 500 600 600 (L) 50/125 Laser-Link 300 2.9 0.9 N/A N/A 1500 500 900 550 (9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 (Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A (K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 Gigabit Ethernet Minimum Link Distances are based on bandwidth /modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. 10 2002, AFL, all rights reserved. PP-1-00003, Revision 6, 12.14.15

Double-Jacket Single-Armor OSP Loose Tube (LE Series SADJ) Ordering Information AFL NO. FIBER COUNT NUMBER OF TUBES/FIBERS NOMINAL DIAMETER NOMINAL WEIGHT INCHES MM LBS/1,000FT KG/KM MAXIMUM TENSILE LOAD SHORT TERM LBS (N) LONG TERM MINIMUM BEND RADIUS SHORT TERM INCHES (CM) LONG TERM LE006 C5111S1 6 1w/6 (4 fillers) 0.59 15.0 128 190 600 (2670) 180 (800) 12.4 (32.0) 5.9 (15.0) LE012 C5111S1 12 1w/12 (4 fillers) 0.59 15.0 128 190 600 (2670) 180 (800) 12.4 (32.0) 5.9 (15.0) LE018 C5111S1 18 1w/12,1w/6 (3 fillers) 0.59 15.0 128 190 600 (2670) 180 (800) 12.4 (32.0) 5.9 (15.0) LE024 C5111S1 24 2w/12 (3 fillers) 0.59 15.0 128 190 600 (2670) 180 (800) 12.4 (32.0) 5.9 (15.0) LE030 C5111S1 30 2w/12,1w/6 (2 fillers) 0.59 15.0 128 190 600 (2670) 180 (800) 12.4 (32.0) 5.9 (15.0) LE036 C5111S1 36 3w/12 (2 fillers) 0.59 15.0 128 190 600 (2670) 180 (800) 12.4 (32.0) 5.9 (15.0) LE048 C5111S1 48 4w/12 (1 filler) 0.59 15.0 128 190 600 (2670) 180 (800) 12.4 (32.0) 5.9 (15.0) LE060 C5111S1 60 5w/12 (no fillers) 0.62 15.0 128 190 600 (2670) 180 (800) 12.4 (32.0) 5.9 (15.0) LE072 C6111S1 72 6w/12 (no fillers) 0.62 15.9 143 212 600 (2670) 180 (800) 13.0 (33.0) 6.5 (16.4) LE084 C8111S1 84 7w/12 (1 filler) 0.69 17.6 169 252 600 (2670) 180 (800) 14.4 (36.4) 7.2 (18.2) LE096 C8111S1 96 8w/12 (no fillers) 0.69 17.6 169 252 600 (2670) 180 (800) 14.4 (36.4) 7.2 (18.2) LE108 CA111S1 108 9w/12 (1 filler) 0.76 19.3 201 299 600 (2670) 180 (800) 15.8 (40.2) 7.9 (20.1) LE120 CA111S1 120 10w/12 (no fillers) 0.76 19.3 201 299 600 (2670) 180 (800) 15.8 (40.2) 7.9 (20.1) LE132 CC111S1 132 11w/12 (1 filler) 0.83 21.2 234 348 600 (2670) 180 (800) 18.0 (46.0) 9.0 (22.9) LE144 CC111S1 144 12w/12 (no fillers) 0.83 21.2 234 348 600 (2670) 180 (800) 18.0 (46.0) 9.0 (22.9) Note: Diameter and weight subject to change without notice Fiber Types Replace asterisk ( ) in AFL number with number in the Fiber Specifications table on previous page. 11 2002, AFL, all rights reserved. PP-1-00003, Revision 6, 12.14.15

All-Dielectric Armored Rodent-Resistant OSP Loose Tube (LN Series) AFL s All-dielectric Rodent-Resistant cable is designed specifically for environments that have an increased risk of rodent infestation and disturbance. The LN-series product line covers the range of fiber-counts of up to 576 fibers. The ultra-hard, non-metallic outer polymer shell reduces risk of transmission interruptions in vital OSP network interconnections. In addition, the cable line meets all applicable RUS, GR-20 and IEC and TIA related design and performance guidelines. Applications Long Haul Networking Building Interconnections (Campus LAN) Steam-tunnel Substreet Drainage Networks Local Loop Airport (FAA-E-2761c, Type B) Cable Components rodent-resistant, low-friction, outer jacket polyethylene inner jacket optical fibers FRP central member ripcords water-blocking system gel-filled loose buffer tube Temperature Specifications TEMPERATURE RANGE INSTALLATION -30ºC to +70ºC OPERATING -40ºC to +70ºC STORAGE -40ºC to +75ºC Typical Lengths MAXIMUM LENGTHS* SINGLE-MODE MULTIMODE FIBER COUNT FEET METERS FEET METERS 6-60 22,900 7,000 22,900 8,000 72-96 22,900 7,000 22,900 7,000 108-120 22,900 7,000 22,900 7,000 132-144 22,600 6,900 22,600 6,900 146-216 17,000 5,200 17,000 5,200 218-288 15,000 4,600 15,000 4,600 290-432 10,800 3,300 10,800 3,300 434-576 6,500 2,000 6,500 2,000 * Longer lengths may be available upon request. Fiber Specifications MAXIMUM ATTENUATION (DB/KM) OVERFILL LAUNCH MIN. BANDWIDTH (MHZ KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM (6) 62.5/125 GIGA-Link 300 3.5 1.2 N/A N/A 200 600 300 550 (5) 50/125 GIGA-Link 600 2.9 0.9 N/A N/A 500 500 600 600 (L) 50/125 Laser-Link 300 2.9 0.9 N/A N/A 1500 500 900 550 (9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 (Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A (K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 Gigabit Ethernet Minimum Link Distances are based on bandwidth /modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. 12 2009, AFL, all rights reserved. PP-1-00019, Revision 5, 12.14.15

All-Dielectric Armored Rodent-Resistant OSP Loose Tube (LN Series) Ordering Information NOMINAL MAXIMUM TENSILN LOAD MINIMUM BEND RADIUS FIBER NUMBER OF DIAMETER NOMINAL WEIGHT LBS (N) INCHES (CM) AFL NO. COUNT TUBES/FIBERS INCHES MM LBS/1,000FT KG/KM SHORT TERM LONG TERM SHORT TERM LONG TERM LN006 C5101N1 6 1w/6 (4 fillers) 0.49 12.5 56 84 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LN012 C5101N1 12 1w/12 (4 fillers) 0.49 12.5 56 84 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LN018 C5101N1 18 1w/12,1w/6 (3 fillers) 0.49 12.5 56 84 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LN024 C5101N1 24 2w/12 (3 fillers) 0.49 12.5 56 84 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LN030 C5101N1 30 2w/12,1w/6 (2 fillers) 0.49 12.5 56 84 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LN036 C5101N1 36 3w/12 (2 fillers) 0.49 12.5 56 84 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LN048 C5101N1 48 4w/12 (1 filler) 0.49 12.5 56 84 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LN060 C5101N1 60 5w/12 (no fillers) 0.49 12.5 56 84 600 (2670) 200 (890) 9.8 (25) 4.9 (13) LN072 C6101N1 72 6w/12 (no fillers) 0.53 13.4 65 97 600 (2670) 200 (890) 10.6 (27) 5.3 (14) LN084 C8101N1 84 7w/12 (1 filler) 0.60 15.2 81 121 600 (2670) 200 (890) 12.0 (31) 6.0 (16) LN096 C8101N1 96 8w/12 (no fillers) 0.60 15.2 81 121 600 (2670) 200 (890) 12.0 (31) 6.0 (16) LN108 CA101N1 108 9w/12 (1 filler) 0.67 17.1 101 151 600 (2670) 200 (890) 13.4 (34) 6.7 (17) LN120 CA101N1 120 10w/12 (no fillers) 0.67 17.1 101 151 600 (2670) 200 (890) 13.4 (34) 6.7 (17) LN132 CC101N1 132 11w/12 (1 filler) 0.75 19.0 123 184 600 (2670) 200 (890) 15.0 (38) 7.5 (19) LN144 CC101N1 144 12w/12 (no fillers) 0.75 19.0 123 184 600 (2670) 200 (890) 15.0 (38) 7.5 (19) LN216 CI301N1 216 18w/12 (no fillers) 0.76 19.3 125 187 600 (2670) 200 (890) 15.2 (39) 7.6 (20) LN288 CO301N1 288 24w/12 (no fillers) 0.87 22.0 156 234 600 (2670) 200 (890) 17.4 (44) 8.7 (22) LN432 IO301N1 432 24w/18 (no fillers) 0.94 23.9 183 273 600 (2670) 200 (890) 18.8 (48) 9.4 (24) LN576 OO301N1 576 24w/24 (no fillers) 1.07 27.3 243 303 600 (2670) 200 (890) 21.4 (55) 10.7 (28) Note: Diameter and weight subject to change without notice Fiber Types Replace asterisk ( ) in AFL number with number in the Fiber Specifications table on previous page. Reel Information REEL A REEL B REEL C REEL D REEL E ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4 Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6 Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4 Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9 Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9 Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request. Larger reel sizes may be required to accomodate long cable lengths. 13 2009, AFL, all rights reserved. PP-1-00019, Revision 5, 12.14.15

Uniflex Non-Armored Loose Tube Cable AFL s non-armored Uniflex is a central loose tube cable used for duct and low fiber drop applications. Product Applications Service (Drop) Cables Building Interconnections (Campus LAN) Connectorized Trunking Cables Distance Learning Distribution Temperature Specifications TEMPERATURE RANGE INSTALLATION -30ºC to +70ºC OPERATING -40ºC to +70ºC STORAGE -40ºC to +75ºC Cable Components Maximum Lengths outer jacket strength elements buffer tube optical fiber water blocking gel ripcord NOMINAL DIAMETER REEL A (42 x 32 x 23) REEL B (58 x 32 x 28) MM FEET METERS FEET METERS 7.8 19,000 5,790 27,500 8,400 Fiber Specifications MAXIMUM ATTENUATION (DB/KM) OVERFILL LAUNCH MIN. BANDWIDTH (MHZ KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM (6) 62.5/125 GIGA-Link 300 3.5 1.2 N/A N/A 200 600 300 550 (5) 50/125 GIGA-Link 600 2.9 0.9 N/A N/A 500 500 600 600 (L) 50/125 Laser-Link 300 2.9 0.9 N/A N/A 1500 500 900 550 (9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 (Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A (K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 Gigabit Ethernet Minimum Link Distances are based on bandwidth /modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. Ordering Information FIBER AFL NO. COUNT LE002 21100N1 2 LE004 41100N1 4 LE006 61100N1 6 LE008 81100N1 8 LE010 A1100N1 10 LE012 C1100N1 12 Note: Diameter and weight subject to change without notice MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS NOMINAL DIAMETER NOMINAL WEIGHT LBS (N) INCHES (CM) INCHES (MM) LBS/1,000FT (KG/KM) SHORT TERM LONG TERM SHORT TERM LONG TERM 0.31 (7.8) 34 (50) 600 (2670) 200 (890) 6.3 (16.0) 3.1 (8.0) Fiber Types Replace asterisk ( ) in AFL number with number in the Fiber Specifications table above. 14 2002, AFL, all rights reserved. PP-1-00026, Revision 3, 12.14.15

Uniflex Armored Loose Tube Cable AFL s Armored Uniflex cable is a central loose tube product used in various outside plant applications. Its compact design holds up to 12 fibers. The corrugated steel armor provides additional mechanical protection and also serves as toneable element within the cable. Temperature Specifications TEMPERATURE RANGE INSTALLATION -30ºC to +70ºC OPERATING -40ºC to +70ºC STORAGE -40ºC to +75ºC Product Applications Service (Drop) Cables Building Interconnections (Campus LAN) Connectorized Trunking Cables Cable Components Maximum Lengths Distance Learning Distribution outer jacket strength elements buffer tube optical fiber water blocking gel ripcord corrugated steel armoring Fiber Specifications NOMINAL DIAMETER REEL A (42 x 32 x 23) REEL B (58 x 32 x 28) REEL C (66 x 36 x 36) MM FEET METERS FEET METERS FEET METERS 12.2 7,700 2,345 18,250 5,560 24,400 7,435 * Maximum lengthof 27,500 feet available on larger reels. MAXIMUM ATTENUATION (DB/KM) OVERFILL LAUNCH MIN. BANDWIDTH (MHZ KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM (6) 62.5/125 GIGA-Link 300 3.5 1.2 N/A N/A 200 600 300 550 (5) 50/125 GIGA-Link 600 2.9 0.9 N/A N/A 500 500 600 600 (L) 50/125 Laser-Link 300 2.9 0.9 N/A N/A 1500 500 900 550 (9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 (Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A (K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 Gigabit Ethernet Minimum Link Distances are based on bandwidth /modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. Ordering Information FIBER AFL NO. COUNT LE002 21200S1 2 LE004 41200S1 4 LE006 61200S1 6 LE008 81200S1 8 LE010 A1200S1 10 LE012 C1200S1 12 MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS NOMINAL DIAMETER NOMINAL WEIGHT LBS (N) INCHES (CM) INCHES (MM) LBS/1,000FT (KG/KM) SHORT TERM LONG TERM SHORT TERM LONG TERM 0.48 (12.2) 95 (140) 600 (2670) 200 (890) 9.6 (25.0) 4.8 (13.0) Note: Diameter and weight subject to change without notice Fiber Types Replace asterisk ( ) in AFL number with number in the Fiber Specifications table above. 15 2002, AFL, all rights reserved. PP-1-00024, Revision 3, 12.14.15

Heavy Duty Uniflex Loose Tube Cable AFL s Heavy Duty Uniflex loose tube cable features a central tube design and thickerwalled jacket. Often used in connectorized cable assemblies, it holds up to 12 fibers. Product Applications Service (Drop) Cables Building Interconnections (Campus LAN) Connectorized Trunking Cables Distance Learning Distribution Temperature Specifications TEMPERATURE RANGE INSTALLATION -30ºC to +70ºC OPERATING -40ºC to +70ºC STORAGE -40ºC to +75ºC Cable Components Maximum Lengths polyn outer jacket strength elements buffer tube optical fiber ripcord water blocking gel NOMINAL DIAMETER REEL A (42 x 36 x 23) REEL B (58 x 36 x 28) MM FEET METERS FEET METERS 7.8 19,000 5,790 27,500 8,400 9.3 13,300 4,050 27,500 8,400 Fiber Specifications MAXIMUM ATTENUATION (DB/KM) OVERFILL LAUNCH MIN. BANDWIDTH (MHZ KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM (6) 62.5/125 GIGA-Link 300 3.5 1.2 N/A N/A 200 600 300 550 (5) 50/125 GIGA-Link 600 2.9 0.9 N/A N/A 500 500 600 600 (L) 50/125 Laser-Link 300 2.9 0.9 N/A N/A 1500 500 900 550 (9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 (Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A (K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 Gigabit Ethernet Minimum Link Distances are based on bandwidth /modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. Ordering Information FIBER AFL NO. COUNT LU002 21200N1 2 LU004 41200N1 4 LU006 61200N1 6 LU008 81200N1 8 LU010 A1200N1 10 LU012 C1200N1 12 NOMINAL NOMINAL MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS DIAMETER WEIGHT LBS. (N) INCHES (CM) INCHES (MM) LBS/1,000 FT (KG/KM) SHORT TERM LONG TERM SHORT TERM LONG TERM 0.366 (9.3) 40 (65) 600 (2670) 200 (890) 7.5 (19.0) 3.7 (9.5) Note: Diameter and weight subject to change without notice Fiber Types Replace asterisk ( ) in AFL number with number in the Fiber Specifications table above. 16 2002, AFL, all rights reserved. PP-1-00008, Revision 3, 12.14.15

Wrapping Tube Cable (WTC) with SWR Wrapping Tube Cable (WTC), with SpiderWeb Ribbon (SWR), is an ultra-high density outside plant cable designed specifically for fiber-to-the-home (FTTH) or access markets. It is compliant with the latest issue of the outside plant cable standard, Telcordia GR-20. With an ultra-high density and a new ribbon technology called SpiderWeb Ribbon, WTC provides the smallest cable diameter and lowest weight, high-fiber count ribbon cable in the industry. With fiber counts from 144 fibers to 1,728 fibers, the cable is available in dielectric or double jacket single armor. SWR is a bonded fiber ribbon design allowing for either a highly efficient ribbon splicing or an individual fiber breakout splicing process. This flexibility allows for a single cable design to cover a diverse set of applications from access networks to high-fiber count mass fusion splicing. With the ability to roll and conform, the SWR provides for ultra-high density packaging in the WTC. Features Access Ready Construction (ARC) Completely gel-free construction with easy-to-access and identify optical fiber circuits. Spider Web Ribbon (SWR) optical fiber technology Easily ribbonized for mass fusion splicing. SWR is compacted and routed like individual fibers. Ideal for organizing slack loops in splice enclosures as there is no preferential bending of ribbon. Significantly higher fiber density compared to traditional ribbon cables Offers ability to expand capacity of existing pathways and allows use of smaller, lower cost duct systems. Smaller cable diameters and cable weights Means longer reel lengths that allow for lower scrap rates, easier handling of reels at the site and reduced transportation costs. Completely dry water-blocking technology Reduces time required to prep cable-end and mid-span access resulting in labor savings. Compact ribbon bundles Reduces enclosure/splice tray size requirements allowing for smaller telecommunications space allocation. Armored and non-armored packages Supports all the standard cable deployment options typically found in the OSP environment including, duct, direct buried and aerial. Fully qualified to Telcordia GR-20 Provides assurance that the cable will support optical fiber network transport functions now and into the future. ARC SWR Technology Rip cord Water blocking tape Armor Strength member SWR Sheath 12F SWR 72F SWR bundle Armored Non-armored 17 2015, AFL, all rights reserved. PP-1-00128, Revision 1, 3.8.16

Wrapping Tube Cable (WTC) with SWR Temperature Specifications TEMPERATURE RANGE INSTALLATION -30C to+70c OPERATING -40C to+70c STORAGE -40C to+70c Mechanical Data Non-Armored DESCRIPTION FIBER COUNT NOMINAL DIAMETER WEIGHT MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS INCHES (MM) LBS/1,000 FT SHORT TERM LONG TERM SHORT TERM (KG/KM) LBS (N) LBS (N) INCHES (CM) LWSE-144-9-C-144-1-00N1D 144 0.406 (10.3) 54 (80) 600 (2700) 182 (810) 8 (20) 4 (10) LWSE-288-9-C-72-4-00N1D 288 0.461 (11.7) 68 (101) 600 (2700) 182 (810) 10 (24) 5 (12) LWSE-432-9-C-72-6-00N1D 432 0.524 (13.3) 88 (130) 600 (2700) 182 (810) 10 (27) 6 (14) LWSE-576-9-C-72-8-00N1D 576 0.583 (14.8) 108 (160) 600 (2700) 182 (810) 12 (30) 7 (15) LWSE-864-9-C-72-12-00N1D 864 0.677 (17.2) 145 (217) 600 (2700) 182 (810) 14 (35) 8 (18) LWSE-1152-9-C-96-12-00N1D 1152 0.720 (18.3) 161 (239) 600 (2700) 182 (810) 15 (38) 8 (19) LWSE-1728-9-C-144-12-00N1D 1728 0.870 (22.1) 228 (330) 600 (2700) 182 (810) 18 (46) 9 (22) LONG TERM INCHES (CM) Mechanical Data Double Jacket Single Armor DESCRIPTION FIBER COUNT NOMINAL DIAMETER WEIGHT MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS INCHES (MM) LBS/1,000 FT SHORT TERM LONG TERM SHORT TERM (KG/KM) LBS (N) LBS (N) INCHES (CM) LWSE-144-9-C-144-1-10S1D 144 0.583 (14.8) 134 (198) 600 (2700) 182 (810) 12 (30) 7 (15) LWSE-288-9-C-72-4-10S1D 288 0.669 (17.0) 168 (248) 600 (2700) 182 (810) 14 (36) 7 (17) LWSE-432-9-C-72-6-10S1D 432 0.732 (18.6) 198 (292) 600 (2700) 182 (810) 16 (38) 8 (19) LWSE-576-9-C-72-8-10S1D 576 0.767 (19.5) 225 (333) 600 (2700) 182 (810) 18 (40) 9 (20) LWSE-864-9-C-72-12-10S10D 864 0.886 (22.5) 275 (408) 600 (2700) 182 (810) 18 (46) 9 (23) LWSE-1152-9-C-96-12-10S1D 1152 0.909 (24.7) 304 (478) 600 (2700) 182 (810) 18 (46) 10 (25) LWSE-1728-9-C-144-12-10S1D 1728 1.094 (27.8) 400 (595) 600 (2700) 182 (810) 22 (57) 11 (28) LONG TERM INCHES (CM) Optical Fiber FIBER TYPE ISO MAXIMUM ATTENUATION (DB/KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) 10 GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM Single-mode ITU-T G.652/G.657.A1 OS2 N/A 0.35 0.25 N/A 5000 N/A 10000 18 2015, AFL, all rights reserved. PP-1-00128, Revision 1, 3.8.16

Gel-Free Non-Armored OSP Loose Tube (LE Series Gel-Free SJ) AFL LE-Series Gel-Free Single Jacket fiber optic cables are designed for outside plant applications and intended for use in communication network connects requiring cable to be installed within duct systems or lashed to aerial messenger wire structures. The product line incorporates the latest dry water-absorption technology within the fibercontaining buffer tubes which results in user-friendly handling of fibers during routing and termination within the slice enclosures. Cable Components Features Gel-free buffer tubes reduce fiber prep termination time SZ-stranded cable core for easy mid-span access of fibers UV-stabilized outer jacket for long-term performance in aerial applications 6 to 288 fibers allow for specific cable choices for multiple applications Standards compliance: - ANSI/ICEA S-87-640 - Telcordia GR-20 - RDUP PE-90 Temperature Specifications TEMPERATURE RANGE INSTALLATION -30ºC to +70ºC OPERATING -40ºC to +70ºC STORAGE -40ºC to +75ºC Typical Lengths Polyethylene jacket Polyester tape Optical fiber FRP central member Rip cord Water-blocking system Gel-free loose buffer tube MAXIMUM LENGTHS* FIBER SINGLE-MODE MULTIMODE COUNT FEET METERS FEET METERS 6-60 22,900 7,000 22,900 7,000 72-96 22,900 7,000 22,900 7,000 108-120 22,900 7,000 22,900 7,000 132-144 22,900 7,000 22,900 7,000 146-216 22,900 7,000 22,900 7,000 218-288 16,400 5,000 16,400 5,000 290-432 14,100 4,300 14,000 4,300 434-576 10,800 3,300 11,000 3,300 * Longer lengths may be available upon request. Fiber Specifications MAXIMUM ATTENUATION (DB/KM) OVERFILL LAUNCH MIN. BANDWIDTH (MHZ KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM (6) 62.5/125 GIGA-Link 300 3.5 1.2 N/A N/A 200 600 300 550 (5) 50/125 GIGA-Link 600 2.9 0.9 N/A N/A 500 500 600 600 (L) 50/125 Laser-Link 300 2.9 0.9 N/A N/A 1500 500 900 550 (9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 (Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A (K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 Gigabit Ethernet Minimum Link Distances are based on bandwidth /modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. 19 2014, AFL, all rights reserved. PP-1-00101, Revision 2, 12.14.15

Gel-Free Non-Armored OSP Loose Tube (LE Series Gel-Free SJ) Mechanical Data NOMINAL NOMINAL MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS NO. OF TUBES DIAMETER WEIGHT LBS (N) INCHES (CM) AFL NO. FIBER COUNT FIBERS/ TUBE INCHES (MM) LBS/1,000FT (KG/KM) SHORT TERM LONG TERM SHORT TERM LONG TERM LE012 C5101N1D 12 1/12 (4 fillers) 0.39 (9.8) 49 (73) 600 (2670) 180 (800) 7.8 (20) 3.9 (10) LE024 C5101N1D 24 2/12 (3 fillers) 0.39 (9.8) 49 (72) 600 (2670) 180 (800) 7.8 (20) 3.9 (10) LE036 C5101N1D 36 3/12 (2 fillers) 0.39 (9.8) 48 (72) 600 (2670) 180 (800) 7.8 (20) 3.9 (10) LE048 C5101N1D 48 4/12 (1 filler) 0.39 (9.8) 48 (71) 600 (2670) 180 (800) 7.8 (20) 3.9 (10) LE060 C5101N1D 60 5/12 (no fillers) 0.39 (9.8) 48 (71) 600 (2670) 180 (800) 7.8 (20) 3.9 (10) LE072 C6101N1D 72 6/12 (no fillers) 0.42 (10.6) 55 (82) 600 (2670) 180 (800) 8.4 (21) 4.2 (11) LE096 C8101N1D 96 8/12 (no fillers) 0.48 (12.3) 75 (118) 600 (2670) 180 (800) 9.6 (25) 4.8 (12) LE144 CC101N1D 144 12/12 (no fillers) 0.62 (15.8) 119 (178) 600 (2670) 180 (800) 12.4 (32) 6.2 (16) LE216 CI301N1D 216 18/12 (no fillers) 0.62 (15.8) 110 (163) 600 (2670) 180 (800) 12.4 (32) 6.2 (16) LE288 CO301N1D 288 24/12 (no fillers) 0.75 (19.1) 148 (220) 600 (2670) 180 (800) 15.0 (38) 7.5 (19) Note: Diameter and weight subject to change without notice Fiber Types Replace asterisk ( ) in AFL number with number in the Fiber Specifications table on previous page. Reel Information REEL A REEL B REEL C REEL D REEL E ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4 Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6 Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4 Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9 Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9 Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request. Larger reel sizes may be required to accomodate long cable lengths. 20 2014, AFL, all rights reserved. PP-1-00101, Revision 2, 12.14.15

Gel-Free Single-Jacket Single-Armor OSP Loose Tube (LE Series Gel-Free SASJ) AFL LE-Series Gel-Free Single Jacket Single Armor fiber optic cables are designed for direct bury, duct and aerial lashed installations outside plant communications infrastructure applications. The corrugated steel armor layer adds additional crush and cut-through resistance making this product line a good choice for campus network applications. The product line incorporates the latest dry water-absorption technology within the fiber-containing buffer tubes which results in user-friendly handling of fibers during routing and termination within the slice enclosures. Features Gel-free buffer tubes reduce fiber prep termination time SZ-stranded cable core for easy mid-span access of fibers Corrugated Steel Armor for improved crush and rodent resistance in direct-bury installations UV-stabilized outer jacket for long-term performance in aerial applications 6 to 288 fibers allow for specific cable choices for multiple applications Standards compliance: - ANSI/ICEA S-87-640 - Telcordia GR-20 - RDUP PE-90 Temperature Specifications TEMPERATURE RANGE INSTALLATION -30ºC to +70ºC OPERATING -40ºC to +70ºC STORAGE -40ºC to +75ºC Cable Components polyethylene jacket optical fiber gel-free loose buffer tube corrugated steel armoring FRP central member rip cord water-blocking system Typical Lengths MAXIMUM LENGTHS* SINGLE-MODE MULTIMODE FIBER COUNT FEET METERS FEET METERS 6-144 19,686 6,000 19,686 6,000 * Longer lengths may be available upon request. Fiber Specifications MAXIMUM ATTENUATION (DB/KM) OVERFILL LAUNCH MIN. BANDWIDTH (MHZ KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM (6) 62.5/125 GIGA-Link 300 3.5 1.2 N/A N/A 200 600 300 550 (5) 50/125 GIGA-Link 600 2.9 0.9 N/A N/A 500 500 600 600 (L) 50/125 Laser-Link 300 2.9 0.9 N/A N/A 1500 500 900 550 (9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 (Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A (K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000 Gigabit Ethernet Minimum Link Distances are based on bandwidth /modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. 21 2014, AFL, all rights reserved. PP-1-00100, Revision 2, 12.14.15

Gel-Free Single-Jacket Single-Armor OSP Loose Tube (LE Series Gel-Free SASJ) Mechanical Data NOMINAL NOMINAL MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS NO. OF TUBES DIAMETER WEIGHT LBS (N) INCHES (CM) AFL NO. FIBER COUNT FIBERS/ TUBE INCHES (MM) LBS/1,000FT (KG/KM) SHORT TERM LONG TERM SHORT TERM LONG TERM LE012 C5201S1D 12 1/12 (4 fillers) 0.50 (12.6) 95 (141) 600 (2670) 180 (800) 10.0 (25) 5.0 (13) LE024 C5201S1D 24 2/12 (3 fillers) 0.50 (12.6) 95 (141) 600 (2670) 180 (800) 10.0 (25) 5.0 (13) LE036 C5201S1D 36 3/12 (2 fillers) 0.50 (12.6) 94 (140) 600 (2670) 180 (800) 10.0 (25) 5.0 (13) LE048 C5201S1D 48 4/12 (1 filler) 0.50 (12.6) 94 (140) 600 (2670) 180 (800) 10.0 (25) 5.0 (13) LE060 C5201S1D 60 5/12 (no fillers) 0.50 (12.6) 94 (139) 600 (2670) 180 (800) 10.0 (25) 5.0 (13) LE072 C6201S1D 72 6/12 (no fillers) 0.53 (13.4) 105 (156) 600 (2670) 180 (800) 10.6 (27) 5.3 (13) LE096 C8201S1D 96 8/12 (no fillers) 0.59 (15.0) 127 (189) 600 (2670) 180 (800) 11.8 (30) 5.9 (15) LE144 CC201S1D 144 12/12 (no fillers) 0.73 (18.5) 182 (271) 600 (2670) 180 (800) 14.6 (37) 7.3 (19) Note: Diameter and weight subject to change without notice Fiber Types Replace asterisk ( ) in AFL number with number in the Fiber Specifications table on previous page. Reel Information REEL A REEL B REEL C REEL D REEL E ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4 Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6 Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4 Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9 Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9 Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request. Larger reel sizes may be required to accomodate long cable lengths. 22 2014, AFL, all rights reserved. PP-1-00100, Revision 2, 12.14.15