FIBER OPTIC CABLE PRODUCTS. CommScope Fiber Optic Cable Products

Size: px
Start display at page:

Download "FIBER OPTIC CABLE PRODUCTS. CommScope Fiber Optic Cable Products"

Transcription

1 CommScope Fiber Optic Cable Products > Loose Tube > Central Tube > Fiber Drop > Hybrids > Tight Buffered FIBER OPTIC CABLE PRODUCTS

2 CommScope Fiber Optic Cable Fiber Optic Cable Overview... F3 Fiber Optic Catalog Numbering Key... F7 Cabled Fiber Specifications Singlemode Fiber... F8 Multimode Fiber Specifications... F11 Loose Tube Cable Designs Dry Stranded Loose Tube Armored... F13 Dry Stranded Loose Tube All-Dielectric... F14 Dry Double Jacketed/Single Armored Stranded Loose Tube... F15 Arid-Core Stranded Loose Tube Armored... F16 Arid-Core Stranded Loose Tube All-Dielectric... F17 Arid-Core Double Jacketed/Single Armored Stranded Loose Tube... F18 Arid-Core Mini Stranded Loose Tube Armored... F19 Arid-Core Mini Stranded Loose Tube Non-Armored... F20 LSZH Arid-Core Mini Stranded Loose Tube Armored... F21 LSZH Arid-Core Mini Stranded Loose Tube Non-Armored... F22 High Density Stranded Loose Tube... F23 ADSS Short Span Stranded Loose Tube... F24 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.250in)... F25 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.250in)... F26 Self-Supporting Figure-8 Arid-Core Dry Stranded Loose Tube Armored (0.250in)... F27 Self-Supporting Figure-8 Arid-Core Dry Stranded Loose Tube Non-Armored (0.250in)... F28 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.188in)... F29 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.188in)... F30 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.109in)... F31 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.109in)... F32 Riser-Rated, Indoor/Outdoor Dry Stranded Loose Tube All-Dielectric... F33 Plenum-Rated, Indoor/Outdoor Dry Stranded Loose Tube All-Dielectric... F34 Riser-Rated, Indoor/Outdoor Dry Stranded Loose Tube with Interlocking Armor... F35 Plenum-Rated, Indoor/Outdoor Dry Stranded Loose Tube with Interlocking Armor... F36 Central Tube Cable Designs Central Tube Armored... F37 Central Tube All-Dielectric... F37 Riser-Rated, Indoor/Outdoor Central Tube All-Dielectric... F38 Fiber Drop Cable Designs Drop Armored... F39 Drop All-Dielectric... F40 Messengered Drop (0.109in)... F41 Messengered Drop (0.083in)... F42 Figure-8 Mini-Drop (Solid Messenger)... F43 Flat Drop... F44 Toneable Flat Drop... F45 LSZH, Indoor/Outdoor Central Tube All-Dielectric... F46 ConQuest Fiber Optic Products... F47 Hybrid Cable Designs Fiber/Coax Designs... F51 Fiber/Twisted Pair Designs... F53 Fiber/Tone Wire Designs... F55 Tight Buffered Cable Designs Riser-Rated, Indoor/Outdoor LSZH Distribution... F58 Riser-Rated, Indoor/Outdoor LSZH Cordage... F59 Riser-Rated, Indoor Distribution... F60 Riser-Rated, Indoor Cordage... F61 Plenum Rated, Indoor Distribution... F62 Plenum-Rated, Indoor Cordage... F63 Packaging and Shipping Information... F64 33 F2

3 CommScope Proven Quality and Performance The Cable Industry s Fiber Supplier TM Better fiber equals better fiber optic cable. CommScope provides key optical and geometrical features in its standard singlemode fiber for fusion splice compatibility with other fiber manufacturers and legacy fiber. LightScope ZWP singlemode optical fiber cable continues a CommScope tradition of being a leader in manufacturing innovative and performanceenhanced products for the cable industry. LightScope ZWP optical fiber cable makes available 30% more usable transmission spectrum, which can be used for return path, enhanced video services such as video on demand (VOD) or Dedicated Wavelength Services for business or other demanding applications. CommScope has developed key families of fiber optic cables specifically to be used throughout the HFC communication hierarchy as well as an offering of fiber optic components including connectors and other passive devices that are commonly required in broadband infrastructure. Outside Plant Cables for Standard and Rugged Environments For direct buried, underground conduit and aerial installations, CommScope offers several designs, which include a variety of loose tube cables. Design options include Drop Armored, a smaller, lighter weight Central Tube cable construction; Central Tube, Flat Drop, and Stranded Loose Tube cables. Craft friendly product solutions are a foremost requirement in today s fast paced world. CommScope engineers are committed to offering evolutionary improvements and easy-to-handle constructions in our fiber product offering. For example, our Dry Loose Tube family of gel-free stranded loose tube cables uses all-dry water blocking technology and reduced diameter buffer tubes. The design is completely gel-free, yet provides full water blocking protection for outside plant applications. Any of these cables may be factory-installed in a variety of CommScope s ConQuest premium high density polyethylene TM conduit including Toneable Conduit a patented location and damage prevention solution. Indoor/Outdoor Cables for Strength and Safety - Including Low-Smoke Zero-Halogen (LSZH) Types CommScope s design for these cables offer construction and jacketing suitable for outside usage yet comply with UL and CSA riser (OFNR) or plenum (OFNP) flame standards. This design allows you to run cable through the building entrance without having to terminate and splice different cables together which results in significant savings in time and labor. Cable types include dielectric central tube designs, dielectric stranded loose tube cables and Triathlon, a specially designed low-smoke/zero halogen distribution and cordage cable construction. Premise Cables for Safety and Performance CommScope s premises cables are designed to handle the unique stresses of indoor applications. Design options include riser and plenum-rated distribution and cordage cables. 32 F3

4 Test Reports - A Higher Standard for Higher Speeds Every reel of CommScope fiber optic cable is subjected to stringent testing throughout the entire manufacturing process. Our state-of-the-art process controls and testing systems ensure that every meter of CommScope cable consistently meets or exceeds our high standards. To prove that our fiber optic cables exceed industry standards, we go to the extra step of attaching an individual cable test report to each reel. In addition to the paper copy of the test reports, we also offer WebTrak, a web program that puts cabling factory results on-line for all of our fiber optic cables. It is our understanding that sometimes this critical test information is misplaced or never makes it to the end-user. With WebTrak, it is easy to find that important paperwork; CommScope s web interface puts factory testing reports for individual cables on-line for 24 hour immediate access. The patented and trademarked WebTrak program resides on our commscope.com website for quick access from any computer. For access to the electronic test reports, all the installers need is the 11 digit serial number printed on the cable jacket and a footage or meter marker for reference. Installers can then enter this number on the WebTrak portion of the CommScope website and pull up the cable s factory test results from anywhere in the world at any time of the day or night. Provides documentation of CommScope fiber optic cable performance, allowing a convenient way to track a reel of cable and verify performance. Provides an alternative to managing paper reports. With WebTrak, you can get all the information you need on-line. Provides quick verifications to ensure the product meets or exceeds performance requirements, should there be a performance issue in the field. Provides easy 24/7 access via the internet. WebTrak is just one more example of how CommScope listens to our customers and delivers. You get proof-positive that the cable you purchase will perform to the level you require. Remember, a network is only as good as the cable that connects it. Specify the cables that make networks work fiber optic cables from CommScope. Request a FREE Broadband Applications & Construction Library CommScope s Broadband Applications & Construction Library includes a 5-piece set of valuable reference manuals plus a DVD containing essential training videos on topics such as connectorization, expansion loop formation and fiber optic splicing. These tools teach you how to protect the integrity of your broadband plant while lowering operating/installation costs. From construction and installation practices, to performance and testing of cable CommScope Construction Manuals are simply a must-have for anyone upgrading or maintaining broadband networks. Download a PDF version at our website: or request a set by phone at CommScope s TM Broadband Resource Center This repository of experience, knowledge, services and tools is provided to CommScope customers to assist installers, technicians, engineers, designers and managers of broadband service providers. Tools in various media and formats include: SpanMaster software for cable sag and tension calculations; center conductor sizing guides; attenuation slide rules; and call center spec assistance and review. Call us at BRC (3272) or [email protected] for answers to product questions or issues related to any CommScope broadband product. 33 F4

5 CommScope Outside Plant Cables Robust Dielectric and Armored Constructions All CommScope Outside Plant (OSP) cables are designed and manufactured to provide outstanding mechanical and optical performance. This cable family includes a loose tube construction to provide multiple levels of protection for the fiber strands. We manufacture all loose tube cables with appropriate Excess Fiber Length (EFL) to ensure, that when properly installed, the fiber strands will remain strain-free, which is essential to good optical performance and longevity. Our heavyduty products are engineered to withstand the rigors of environmental extremes. There are many cable choices when considering applications that require environmental protection and provide for network diversity. CommScope cable surpasses requirements in the aerial, underground and conduit applications. We offer self-support cable for aerial environments and cable-in-conduit or armored cables for extra protection in burial applications. CommScope manufactures cables that are lightweight, flexible and especially suited for aerial cable installations. Our loose tube cables are available in armored and alldielectric versions. OSP Fiber Optic Cable Design Options Include: Drop - a small, lightweight Central Tube cable designed for use when space is at a minimum; features a robust PBT buffer tube and is available in fiber counts up to 12 Central Tube - armored and dielectric construction for point-to-point installations in counts up to 96 arranged in easy-to-handle color-coded subunits of 12 fiber each Stranded Loose Tube - for direct buried, underground conduit and aerial installations; design variations range from all-dielectric to armored constructions with up to 576 fibers Dry Loose Tube Craft friendly product solutions are a foremost requirement in today s fast paced world. CommScope engineers are committed to offering evolutionary improvements and easyto-handle constructions in our fiber product offering. The latest example is our new Dry Loose Tube cable design. This family of gel-free stranded loose tube cables uses all-dry water blocking technology and reduced diameter buffer tubes. The design is completely gel-free, yet provides full water blocking protection for outside plant applications and meets all of the requirements for outside plant cable. Arid-Core Moisture Barrier CommScope defeats moisture with a unique multi-level approach. In addition to tough outer jacketing, we employ Arid-Core, a super-absorbent polymer technology. Arid-Core is applied between the jacket and the buffer tubes in stranded loose tube cables, and coats the central tubes of drop armored and central tube cables. When moisture meets Arid-Core, the polymer swells to prevent moisture migration - it acts as a mechanical block to prevent further water penetration. CommScope OSP fiber optic cables are designed to meet or exceed the requirements of Telcordia, EIA/TIA, REA/RUS, IEC and RUS industry standards. Drop Cables CommScope s Drop family of cables offer craft friendly access product solutions for Fiber to the Premise (FTTP) applications designed for use as systems develop commercial services and expand networks to non-traditional customers. The design of drop cables compliments the needs often found for the last mile of your fiber network. Drop cables offer a compact, flexible and cost-efficient configuration that provides low-loss performance when twelve fibers or less are needed. Drop cables are commonly used to branch from the main cable route to outlying distribution points or the premise. All drop cables can be pre-installed in conduit. 32 F5

6 CommScope Cable Constructions Stranded Loose Tube Available in All-Dielectric and Armored designs with up to 576 fibers For Direct Buried, Underground Conduit, and Aerial installations Available in ADSS and Figure-8 constructions Hybrid configurations that include coax or copper conductors are available Mini-Diameter Stranded Loose Tube Smaller, lightweight cable design utilizing 2.0mm buffer tubes Available with up to 144 fibers in Armored, All- Dielectric and LSZH designs Improved ease of handling and better utilization of duct space Indoor/Outdoor Stranded Loose Tube Riser, Plenum, and Low Smoke Zero Halogen (LSZH) constructions Eliminates the need for a splice point when entering a building Tough enough for the OSP environment and flame rated for indoor use Drop Cost effective, low fiber count cables for outside plant applications Wide variety of flexible, versatile, and craft-friendly products available For Direct Buried, Underground Conduit, and Aerial Drop applications Small, lightweight cable designs developed for ease of installation Hybrid Cables Flexibility and options for future growth in a single cost-effective cable run Easier material management Capable of voice transmission, cable location, and site powering Messenger Figure-8 Multiple messenger size options for increased versatility in designs with up to 60 fibers Allows easy, one-step installation resulting in cost savings Armored and Non-Armored versions with.250 messenger available with up to 288 fibers Central Tube Available in All-Dielectric and Armored designs with up to 96 fibers Effective solution for point-to-point installations Robust constructions offer excellent fiber protection Single buffer tube saves time and reduces termination costs Premise Cables Complete line of Riser and Plenum rated cables for indoor use Engineered to provide excellent mechanical and optical performance FiberGuard Aluminum Interlocking Armor available 33 F6

7 Fiber Optic Catalog Numbering Key Steps to Building the Catalog Number for the Cable You Need! CommScope Catalog Number Position CABLE STYLE (Position 1) D...Dry O...Outdoor (Arid Core Standard) S...Self-Supporting (ADSS) M...Messenger P...Plenum R...Riser Z...Zero Halogen FIBER COUNT* (Positions 2, 3, & 4) Total Fiber Count (in increments of two) *Substitute for XXX variable in catalog number. CONSTRUCTION (Positions 5 & 6) Loose Tube Cables LA...Stranded Loose Tube Armored LN...Stranded Loose Tube Non-Armored L2...Stranded Loose Tube Double Jacketed, Single Armored LZ...Indoor/Outdoor Stranded Loose Tube, Aluminum Interlocking Armor DA...Drop Armored DN...Drop Non-Armored DF...Flat Drop MN...Mini-Drop Non-Armored CA...Central Tube Armored CN...Central Tube Non-Armored, All-Dielectric Tight Buffered Cables DS...Distribution SP...Simplex IC...Interconnect ZC...Zipcord CABLE MARKING (Position 9) F...Jacket Sequentially Marked in Feet (standard) M...Jacket Sequentially Marked in Meters X...Custom Print Required CABLE CONSTRUCTION SPECIFICS (Position 10) For outdoor and indoor/outdoor loose tube cables, this value indicates the fiber content per subunit: Fiber Count Per Subunit For indoor distribution cables, this value indicates additional information pertaining to the cable construction: SU...Single Unit Construction MU...Multi-Unit Construction For cordage cables, this value indicates the outside diameter: mm Jacket Outer Diameter mm Jacket Outer Diameter mm Jacket Outer Diameter COLOR FIELD (Positions 11 & 12) For outdoor cables, this field designates the tracer/stripe requirements: NS...No Stripe (Std) WH...White BL...Blue YL...Yellow OR...Orange VI...Violet GR...Green For indoor/outdoor cables, this field designates the jacket color: BK...Black For indoor cables, this field designates jacket color: OR... Orange µm multimode and composite cables YL...Yellow - singlemode cables AQ...Aqua - 50 µm multimode LazrSPEED cables FIBER TYPE (Positions 7 & 8) Singlemode 8W...LightScope ZWP Dispersion-Unshifted, Matched-Clad, Singlemode Fiber 8F...Bend Insensitive Singlemode Fiber 8T...LightScope NZD TM Shifted, Singlemode Fiber Multimode 6F µm, FDDI Grade, Multimode Fiber 5M...LazrSPEED CM...Composite (Singlemode & Multimode) Hybrids HY...Fiber/Copper *XY variable in catalog number Note: Non-standard jacket colors are available. (minimum order required) Please contact your Customer Service Representative for additional information. ZZ variable in catalog number NOTES When Positions 7 & 8 are CM (composite cables), positions are required. Positions 14 & Singlemode fiber type Positions Singlemode fiber count (aaa variable in the catalog number) Positions 19 & Multimode fiber type Positions Multimode fiber count (bbb variable in the catalog number) Please note that positions 13 and above are often used to differentiate similar cable constructions. Please see the individual product pages for additional part number details. F7

8 Type 8W Singlemode Fiber Specifications Available in All CommScope Cable Types Zero Water Peak: Dispersion-Unshifted, Standards Compliance: ITU-T G.652.D Physical Characteristics Cladding Diameter 125 ± 0.7 µm Core/Clad Offset < 0.5 µm Coating Diameter (uncolored) 245 ± 10 µm Coating Diameter (colored) 254 ± 7 µm Coating/Cladding Concentricity Error, maximum 12 µm Clad Non-Circularity < 1% Mechanical Characteristics Proof Test 100 kpsi (.69 Gpa) Coating Strip Force lbf ( N) Fiber Curl > 4 m Dynamic Fatigue Parameter > 20 nd Macrobend mm mandrel 1310/1550 nm 0.05 db maximum Macrobend mm mandrel 1625nm 0.05 db maximum Macrobend 1 32 mm mandrel 1550 nm 0.05 db maximum Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 1310 nm 0.34 db/km 1385 nm 0.31 db/km 1550 nm 0.22 db/km Attenuation, Tight Buffer Cable 1310 nm 0.50 db/km 1385 nm 0.50 db/km 1550 nm 0.50 db/km Mode Field Diameter 1310 nm µm 1385 nm µm 1550 nm µm Group Refractive Index 1310 nm nm nm Dispersion 1310 nm 3.2 ps/(nm-km) from 1285 to 1330 nm 1550 nm 18 ps/(nm-km) Optical Characteristics, General Point Defects, maximum Cutoff Wavelength Zero Dispersion Wavelength Zero Dispersion Slope Polarization Mode Dispersion Link Design Value 0.10 db < 1260 nm nm ps/(km-nm-nm) < 0.06 ps/sqrt(km) Environmental Characteristics Temperature Dependence -60 C to +85 C Temperature Humidity Cycling -10 C to +85 C up to 95% RH Water Immersion, C Heat Aging, C < 0.05 db < 0.05 db < 0.05 db < 0.05 db F8

9 Bend Insensitive Type 8F Singlemode Fiber Specifications Available in All CommScope Cable Types Dispersion-Unshifted, Standards Compliance: ITU-T G.657.A Physical Characteristics Cladding Diameter 125 ± 0.7 µm Core/Clad Offset < 0.5 µm Coating Diameter (uncolored) 245 ± 10 µm Coating Diameter (colored) 254 ± 7 µm Coating/Cladding Concentricity Error, maximum 12 µm Clad Non-Circularity < 1% Mechanical Characteristics Proof Test 100 kpsi (.69 Gpa) Coating Strip Force lbf ( N) Fiber Curl > 4 m Dynamic Fatigue Parameter > 18 nd Macrobend mm diameter (maximum) 1550 nm 0.01 db 1625 nm 0.05 db Macrobend mm diameter (maximum) 1550 nm 0.2 db 1625 nm 0.5 db Macrobend 1 30 mm diameter (maximum) 1550 nm 0.02.dB Macrobend 1 20 mm diameter (maximum) 1550 nm 0.2 db Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 1310 nm 0.36 db/km db/km 1550 nm 0.25 db/km Attenuation, Tight Buffer Cable 1310 nm 0.50 db/km 1385 nm 0.50 db/km 1550 nm 0.50 db/km Mode Field Diameter 1310 nm µm 1550 nm µm Group Refractive Index 1310 nm nm nm Dispersion 1310 nm 3.5 ps/(nm-km) from 1285 to 1330 nm 1550 nm 18 ps/(nm-km) Optical Characteristics, General Point Defects, maximum Cutoff Wavelength Zero Dispersion Wavelength Zero Dispersion Slope Polarization Mode Dispersion Link Design Value 0.10 db < 1260 nm nm ps/(km-nm-nm) < 0.06 ps/sqrt(km) F9 Environmental Characteristics Temperature Dependence -60 C to +85 C Temperature Humidity Cycling -10 C to +85 C up to 95% RH Water Immersion, C Heat Aging, C < 0.05 db < 0.05 db < 0.05 db < 0.05 db

10 LightScope NZD TM Type 8T Singlemode Fiber Specifications Available in CommScope Outside Plant Cable Types Non-Zero Dispersion Standards Compliance: ITU-T G.655.C, D Physical Characteristics Cladding Diameter 125 ± 0.7 µm Core/Clad Offset < 0.5 µm Coating Diameter (uncolored) 245 ± 5 µm Coating Diameter (colored) 256 ± 8 µm Coating/Cladding Concentricity Error, maximum 10 µm Clad Non-Circularity < 0.7% Mechanical Characteristics Proof Test 100 kpsi (.69 Gpa) Coating Strip Force lbf ( N) Fiber Curl Dynamic Fatigue Parameter Macrobend mm mandrel > 4 m > 20 nd 1550 and 1625 nm 0.05 db maximum Macrobend 1 32mm mandrel 1550 and 1625nm 0.50 db maximum Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 1310 nm 0.45 db/km 1550 nm 0.25 db/km 1625 nm 0.34 db/km Mode Field Diameter 1550 nm µm 1625 nm µm Group Refractive Index 1310 nm nm nm Dispersion 1310 nm -8 ps/(nm-km) (typical) 1550 nm 2.6 to 6 ps/(nm-km) from nm 1625 nm 4.0 to 8.9 ps/(nm-km) from nm Optical Characteristics, General Maximum Attenuation at 1385 nm Point Defects, maximum Cutoff Wavelength Dispersion Slope Polarization Mode Dispersion Link Design Value 0.45 db/km 0.10 db < 1260 nm < 0.05 ps/(km-nm-nm) at 1550 nm < 0.04 ps/sqrt(km) Environmental Characteristics Temperature Dependence -60 C to +85 C Temperature Humidity Cycling -10 C to +85 C up to 95% RH Water Immersion, C Heat Aging, C < 0.05 db < 0.05 db < 0.05 db < 0.05 db F10

11 Type 6F Multimode Fiber Specifications Available in All CommScope Cable Types 62.5 micron, FDDI Grade Multimode Fiber Standards Compliance: TIA 492AAAA (OM1) Physical Characteristics Core Diameter 62.5 ± 2.5 µm Cladding Diameter 125 ± 1.0 µm Core/Clad Offset < 1.0 µm Coating Diameter (uncolored) 245 ± 10 µm Coating Diameter (colored) 254 ± 7 µm Coating/Cladding Concentricity Error, maximum 8 µm Clad Non-Circularity < 1% Mechanical Characteristics Proof Test 100 kpsi (.69 Gpa) Coating Strip Force lbf ( N) Dynamic Fatigue Parameter > 18 nd Macrobend mm mandrel 850 nm and 1300 nm 0.50 db maximum Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 850 nm 3.0 db/km 1300 nm 1.0 db/km Attenuation, Tight Buffer Cable 850 nm 3.4 db/km 1300 nm 1.0 db/km Bandwidth, OFL (Over-Filled Launch) 850 nm 220 MHz - km 1300 nm 500 MHz - km Group Refractive Index 850 nm nm GB Ethernet Distance 850 nm 300 m 1300 nm 550 m Optical Characteristics, General Numerical Aperature ± Point Defects, maximum 0.15 db Zero Dispersion Wavelength nm Zero Dispersion Slope, maximum ps/(km-nm-nm) Environmental Characteristics Temperature Dependence -60 C to +85 C Temperature Humidity Cycling -10 C to +85 C up to 95% RH Water Immersion, C Heat Aging, C < 0.20 db < 0.20 db < 0.20 db < 0.20 db F11

12 LazrSPEED 150 Type 5M Multimode Fiber Specifications Available in All CommScope Cable Types LazrSPEED 150, 50 micron Multimode Fiber Standards Compliance: Exceeds TIA 492AAAB (OM2+) Physical Characteristics Core Diameter 50.0 ± 2.5 µm Cladding Diameter 125 ± 1.0 µm Core/Clad Offset < 1.5 µm Coating Diameter (uncolored) 245 ± 10 µm Coating Diameter (colored) 255 ± 7 µm Coating/Cladding Concentricity Error, maximum 6 µm Clad Non-Circularity < 1% Mechanical Characteristics Proof Test 100 kpsi (.69 Gpa) Coating Strip Force lbf ( N) Dynamic Fatigue Parameter > 18 nd Macrobend mm mandrel 850 nm and 1300 nm 0.50 db maximum Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 850 nm 3.0 db/km 1300 nm 1.0 db/km Attenuation, Tight Buffer Cable 850 nm 3.0 db/km 1300 nm 1.0 db/km Bandwidth, OFL 850 nm 700 MHz - km 1300 nm 500 MHz - km Bandwidth, Laser 850 nm 950 MHz - km 1300 nm 500 MHz - km Differential Mode Delay 850 nm 0.70 ps/m 1300 nm 0.88 ps/m Group Refractive Index 850 nm nm GB Ethernet Distance 850 nm 800 m 1300 nm 600 m 10 GB Ethernet Distance 850 nm 150 m Optical Characteristics, General Numerical Aperature Point Defects, maximum 0.15 db Zero Dispersion Wavelength nm Zero Dispersion Slope ps/(km-nm-nm) Environmental Characteristics Temperature Dependence -60 C to +85 C Temperature Humidity Cycling -10 C to 85 C up to 95% RH Water Immersion, C Heat Aging, C 0.10 db 0.10 db 0.20 db 0.20 db F12

13 Outside Plant Gel-Free Stranded Loose Tube Cable Armored Jacket/Armor Combinations for Buried/Underground/Aerial Applications 100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ Single Armor D-XXX-LA-XY-F12NS / / / / / Fibers Fibers D-XXX-LA-XY-F12NS / / / / / Fibers D-XXX-LA-XY-F12NS / / / / / Fibers D-XXX-LA-XY-F12NS / / / / / Fibers D-XXX-LA-XY-F12NS / / / / / Fibers D-XXX-LA-XY-F12NS / / / / / Fibers D-XXX-LA-XY-F12NS / / / / / Singlemode/Multimode Composite (4-288 Fibers) D-XXX-LA-CM-F12NS/AAaaa/BBbbb Refer to above specifications. Buffer Tubes repeat color sequence with tracer stripe F13 Gel-Free Stranded Loose Tube Armored Cable (72 Fiber Version Shown) PE Outer Jacket Steel Tape Armoring Water Swellable Tape 2.5mm Gel-Free Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (2) Installation Temperature Operating Temperature Storage Temperature -22 to +158 F (-30 to +70 C) -40 to +158 F (-40 to +70 C) -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN ; RUS/RDUP 7 CFR RD Telecommunications Program Listed.

14 Outside Plant Gel-Free Stranded Loose Tube Cable Non-Armored, All-Dielectric For Buried/Underground/Aerial Applications 100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment Lightweight, small design is installer-preferred due to ease of handling Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ 2-60 Fibers D-XXX-LN-XY-F12NS / / / / / Fibers D-XXX-LN-XY-F12NS / / / / / Fibers D-XXX-LN-XY-F12NS / / / / / Fibers D-XXX-LN-XY-F12NS / / / / / Fibers D-XXX-LN-XY-F12NS / / / / / Fibers D-XXX-LN-XY-F12NS / / / / / Fibers D-XXX-LN-XY-F12NS / / / / / Singlemode/Multimode Composite (4-288 Fibers) D-XXX-LN-CM-F12NS/AAaaa/BBbbb Refer to above specifications. Buffer Tubes repeat color sequence with tracer stripe Gel-Free Stranded Loose Tube Non-Armored, All-Dielectric Cable (72 Fiber Version Shown) PE Outer Jacket Water Swellable Tape 2.5mm Gel-Free Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN ; RUS/RDUP 7 CFR RD Telecommunications Program Listed. F14

15 Outside Plant Gel-Free Stranded Loose Tube Cable Double Jacketed, Single Armored Double Jacket for Buried/Underground/Aerial Applications 100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment Corrugated steel tape is strong yet flexible, providing additional crush and rodent protection Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Double Jacket/ Single Armor D-XXX-L2-XY-F12NS / / / / / Fibers Fibers D-XXX-L2-XY-F12NS / / / / / Fibers D-XXX-L2-XY-F12NS / / / / / Fibers D-XXX-L2-XY-F12NS / / / / / Fibers D-XXX-L2-XY-F12NS / / / / / Fibers D-XXX-L2-XY-F12NS / / / / / Fibers D-XXX-L2-XY-F12NS / / / / / Singlemode/Multimode D-XXX-L2-CM-F12NS/AAaaa/BBbbb Composite (4-288 Fibers) Refer to above specifications. F15 Gel-Free Stranded Loose Tube Armored Cable Double Jacketed, Single Armored (72 Fiber Version Shown) PE Outer Jacket Steel Tape Armoring Water Blocking Tape 2.5mm Gel-Free Buffer Tubes PE Inner Jacket Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN ; RUS/RDUP 7 CFR RD Telecommunications Program Listed.

16 Outside Plant Arid-Core Stranded Loose Tube Cable Armored Jacket/Armor Combinations for Buried/Underground/Aerial Applications Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ Single Armor O-XXX-LA-XY-F12NS/25T / / / / / Fibers Fibers O-XXX-LA-XY-F12NS/25T / / / / / Fibers O-XXX-LA-XY-F12NS/25T / / / / / Fibers O-XXX-LA-XY-F12NS/25T / / / / / Fibers O-XXX-LA-XY-F12NS/25T / / / / / Fibers O-XXX-LA-XY-F12NS/25T / / / / / Fibers O-XXX-LA-XY-F12NS/25T / / / / / Singlemode/Multimode Composite (4-288 Fibers) O-XXX-LA-CM-F12NS/25T/AAaaa/BBbbb Refer to above specifications. Buffer Tubes repeat color sequence with tracer stripes Arid-Core Stranded Loose Tube Armored Cable (72 Fiber Version Shown) PE Outer Jacket Steel Tape Armoring Water Swellable Tape 2.5 mm Gel Filled Buffer Tubes Water Blocking Gel Dielectric Strength Member Strength Elements 250 Micron Fiber Ripcord (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F16

17 Outside Plant Arid-Core Stranded Loose Tube Cable Non-Armored, All-Dielectric For Buried/Underground/Aerial Applications Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Lightweight, small design is installer-preferred due to ease of handling Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ 2-60 Fibers O-XXX-LN-XY-F12NS/25T / / / / / Fibers O-XXX-LN-XY-F12NS/25T / / / / / Fibers O-XXX-LN-XY-F12NS/25T / / / / / Fibers O-XXX-LN-XY-F12NS/25T / / / / / Fibers O-XXX-LN-XY-F12NS/25T / / / / / Fibers O-XXX-LN-XY-F12NS/25T / / / / / Fibers O-XXX-LN-XY-F12NS/25T / / / / / Singlemode/Multimode Composite (4-288 Fibers) O-XXX-LN-CM-F12NS/25T/AAaaa/BBbbb Refer to above specifications. Buffer Tubes repeat color sequence with tracer stripes Arid-Core Stranded Loose Tube Non-Armored, All-Dielectric Cable (72 Fiber Version Shown) PE Outer Jacket Water Swellable Tape 2.5 mm Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F17

18 Multi-Jacketed Stranded Loose Tube Cable Double Jacketed, Single Armored Jacket/Armor Combinations for Buried/Underground/Aerial Applications Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Double Jacket/ Single Armor O-XXX-L2-XY-F12NS/25T / / / / / Fibers Fibers O-XXX-L2-XY-F12NS/25T / / / / / Fibers O-XXX-L2-XY-F12NS/25T / / / / / Fibers O-XXX-L2-XY-F12NS/25T / / / / / Fibers O-XXX-L2-XY-F12NS/25T / / / / / Fibers O-XXX-L2-XY-F12NS/25T / / / / / Fibers O-XXX-L2-XY-F12NS/25T / / / / / Singlemode/Multimode O-XXX-L2-CM-F12NS/25T/AAaaa/BBbbb Composite (4-288 Fibers) *Other jacket/armor configurations available upon request. Refer to above specifications. Double Jacket/Single Armor Loose Tube Cable (72 Fiber Version Shown) PE Outer Jacket Ripcord (2) Steel Tape Armoring Water Blocking Tape 2.5 mm Buffer Tubes PE Inner Jacket Dielectric Strength Member 250 Micron Fibers Water Blocking Tape Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN ; RUS/RDUP CFR RD Telecommunications Program Listed F18

19 Outside Plant Arid-Core Mini Stranded Loose Tube Cable Armored Jacket/Armor Combinations for Buried/Underground/Lashed Aerial Applications Very small 2.0 mm buffer tubes improve kink resistance and facilitate route management in closures Lightweight, small design is installer-preferred due to ease of handling Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Smaller form factor cable can be utilized for tight duct spaces Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ Single Armor 2-72 Fibers O-XXX-LA-XY-FZZNS/20T / / / / / Fibers O-XXX-LA-XY-FZZNS/20T / / / / / Fibers O-XXX-LA-XY-FZZNS/20T / / / / / Fibers O-XXX-LA-XY-FZZNS/20T / / / / / Mini-Diameter Stranded Loose Tube Cable (72 Fiber Armored Version Shown) PE Outer Jacket Steel Tape Armoring Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Water Blocking Gel Dielectric Strength Member Strength Elements 250 Micron Fiber Ripcord (2) Installation Temperature Operating Temperature Storage Temperature -22 to +158 F (-30 to +70 C) -40 to +158 F (-40 to +70 C) -40 to +167 F (-40 to +75 C) Compression (Armored) 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC , Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F19

20 Outside Plant Arid-Core Mini Stranded Loose Tube Cable Non-Armored, All-Dielectric For Buried/Underground/Lashed Aerial Applications Lightweight, small design is installer-preferred due to ease of handling Smaller form factor cable which can be utilized for tight duct space requirements Small and flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ 2-72 Fibers O-XXX-LN-XY-F12NS/20T / / / / / Fibers O-XXX-LN-XY-F12NS/20T / / / / / Fibers O-XXX-LN-XY-F12NS/20T / / / / / Fibers O-XXX-LN-XY-F12NS/20T / / / / / Arid-Core Mini Stranded Loose Tube Non-Armored, All-Dielectric Cable (72 Fiber Version Shown) PE Outer Jacket Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F20

21 Indoor/Outdoor LSZH Arid-Core Mini Stranded Loose Tube Cable Low-Smoke Zero-Halogen, Armored For Indoor/Outdoor Applications that Require a LSZH Rating Helps eliminate transition splicing at the building entrance Lightweight, small design is installer-preferred due to ease of handling Flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management UV-resistant jacket suitable for use outdoors Corrugated steel armor is strong yet flexible providing additional crush and rodent protection Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ 2-72 Fibers Z-XXX-LA-XY-F12BK/20G / / / / / Fibers Z-XXX-LA-XY-F12BK/20G / / / / / Fibers Z-XXX-LA-XY-F12BK/20G / / / / / Fibers Z-XXX-LA-XY-F12BK/20G / / / / / LSZH Arid Core Mini Stranded Loose Tube Armored Cable (72 Fiber Version Shown) LSZH Outer Jacket Steel Tape Armoring Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Flame Test Specifications Flame Test Listing NEC Type: OFNR-LS (ETL) and c(etl) Flame Test Standard UL-1666, UL-1685, IEC , IEC ; IEC , IEEE 383 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 2; EN F21

22 Indoor/Outdoor LSZH Mini Stranded Loose Tube Cable Low-Smoke Zero-Halogen, Non-Armored, All-Dielectric For Indoor/Outdoor Applications that Require a LSZH Rating Helps eliminate transition splicing at the building entrance Lightweight, small design is installer-preferred due to ease of handling Flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management UV-resistant jacket suitable for use outdoors Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ 2-72 Fibers Z-XXX-LN-XY-F12BK/20G / / / / / Fibers Z-XXX-LN-XY-F12BK/20G / / / / / Fibers Z-XXX-LN-XY-F12BK/20G / / / / / Fibers Z-XXX-LN-XY-F12BK/20G / / / / / LSZH Mini Stranded Loose Tube Non-Armored, All-Dielectric Cable (72 Fiber Version Shown) LSZH Outer Jacket Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Flame Test Specifications Flame Test Listing NEC Type: OFNR-LS (ETL) and c(etl) Flame Test Standard UL-1666, UL-1685, IEC , IEC ; IEC , IEEE 383 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 2; EN F22

23 Outside Plant Stranded Loose Tube Cable High Density Loose Tube For Buried/Underground/Aerial Applications Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Flexible buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Eliminates the need for ribbonized fibers by giving you a compact cable with up to 576 loose fibers Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Armored Fibers O-XXX-LA-XY-F24NS / / / / / Fibers O-XXX-LA-XY-F24NS / / / / / All Dielectric Fibers O-XXX-LN-XY-F24NS / / / / / Fibers O-XXX-LN-XY-F24NS / / / / / Double Jacketed Single Armored O-XXX-L2-XY-F24NS / / / / / Fibers Fibers O-XXX-L2-XY-F24NS / / / / / Buffer Tubes repeat color sequence with tracer stripe All-Dielectric High Density Loose Tube Fiber Cable (432 Fiber Version Shown) PE Outer Jacket Strength Elements 3.5 mm Gel Filled Buffer Tube Dielectric Strength Member Fiber Threads Water Swellable Tape 250 Micron Optical Fibers Ripcord (1) Subunit Detail Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression (dielectric) 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Compression (armored) 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F23

24 ADSS Short Span Loose Tube Cable All-Dielectric, Self-Supporting (ADSS) Aerial Design For Aerial Long Haul and Metro Applications Small cable diameter and bend radius for lightweight and ease of handling and installation Designed for aerial spans requiring a self-supporting, non-messengered product Single Medium Density Polyethylene (MDPE) jacket for fast convenient cable preparation Fully qualified in accordance with Telcordia Technologies, EIA/TIA and IEEE Standards Product Type/ Catalog Sub Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Units inch/mm Loaded Unloaded Short Term Long Term l bs/ kg/ inch/cm lbs/newtons kft km kft km Single Jacket 2-60 Fibers S-XXX-LN-XY-F12NS/NFB / / / / / Other ADSS designs are available upon request. Buffer Tubes repeat color sequence with tracer stripe Custom Sag & Tension Tables are available upon request. ADSS Double Jacket Loose Tube All-Dielectric Cable (60 Fiber Version Shown) PE Outer Jacket Aramid Strength Elements 3.0mm Gel-Filled Buffer Tube Dielectric Strength Member Water Swellable Tape Ripcord (1) 250 Micron Fibers Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F24

25 Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube Armored For Aerial Applications Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Uses standard figure-8 cable hardware and installation practices 100% gel-free stranded loose tube cable reduces cable prep time Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Minimum Bend Radius Weight Product Type/ Catalog Buffer Cable OD Cable Height Messenger Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm Jacket. OD inch/cm inch/cm kft km Figure-8 Armored 2-60 Fibers M-XXX-LA-XY-F12NS/ / / / / / D Figure-8 Armored Cable (60 Fiber Version Shown) MPDE Outer Jacket Stranded 0.25 Galvanized Steel Messenger Steel Tape Armoring Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F25

26 Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube Non-Armored For Aerial Applications Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Uses standard figure-8 cable hardware and installation practices 100% gel-free stranded loose tube cable reduces cable prep time Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip \ Cable Outer Messenger Minimum Bend Radius Weight Product Type/ Catalog Buffer Diameter Cable Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm inch/mm inch/cm inch/cm kft km Figure-8 Non-Armored 2-60 Fibers M-XXX-LN-XY-F12NS/ / / / / / D Figure-8 Self-Supporting Non-Armored Cable (60 Fiber Version Shown) MDPE Outer Jacket Stranded 0.25 Flooded Steel Messenger Water Swellable Tape Strength Elements 2.5 mm Gel-Free Buffer Tube Dielectric Strength Member 250 Micron Fiber Ripcord Installation Temperature Operating Temperature Storage Temperature -22 to +158 F (-30 to +70 C) -40 to +158 F (-40 to +70 C) -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F26

27 Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube Armored For Aerial Applications Figure-8 cable design allows easy, one-step installation resulting in cost savings Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Uses standard figure-8 cable hardware and installation practices Cable Outer Messenger Minimum Bend Radius Weight Product Type/ Catalog Sub Diameter Cable Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm inch/cm lbs/newtons kft km Figure-8 Armored 2-60 Fibers M-XXX-LA-XY-F12NS / / / / / Fibers M-XXX-LA-XY-F12NS / / / / / Fibers M-XXX-LA-XY-F12NS / / / / / Fibers M-XXX-LA-XY-F12NS / / / / / Fibers M-XXX-LA-XY-F12NS / / / / / Figure-8 Armored Cable (72 Fiber Version Shown) MPDE Outer Jacket Stranded 0.25 Galvanized Steel Messenger Steel Tape Armoring Water Swellable Tape 3.0 mm Gel Filled Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F27

28 Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube Non-Armored For Aerial Applications Figure-8 cable design allows easy, one-step installation resulting in cost savings Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Standard color-coding on fibers and buffer tubes helps ease installation All buffer tubes are constructed to a nominal OD of 3mm reducing the number of tools required in the field Uses standard figure-8 cable hardware and installation practices Cable Outer Messenger Minimum Bend Radius Weight Product Type/ Catalog Sub Diameter Cable Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm inch/cm lbs/newtons kft km Figure-8 Non-Armored 2-60 Fibers M-XXX-LN-XY-F12NS / / / / / Fibers M-XXX-LN-XY-F12NS / / / / / Fibers M-XXX-LN-XY-F12NS / / / / / Fibers M-XXX-LN-XY-F12NS / / / / / Fibers M-XXX-LN-XY-F12NS / / / / / Figure-8 Non-Armored Cable (72 Fiber Version Shown) MDPE Outer Jacket Stranded 0.25 Galvanized Steel Messenger Water Swellable Tape Strength Elements 3.0 mm Gel-Filled Buffer Tube Dielectric Strength Member 250 Micron Fiber Ripcord Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F28

29 Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube Armored For Aerial Applications 100% gel-free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km Figure-8 Armored 2-60 Fibers M-XXX-LA-XY-F12NS/ / / / / / D/188 Figure-8 Armored Cable (60 Fiber Version Shown) MPDE Outer Jacket Stranded 3/16 Galvanized Steel Messenger Steel Tape Armoring Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F29

30 Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube, Non-Armored For Aerial Applications 100% gel-free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km Figure-8 Non-Armored 2-60 Fibers M-XXX-LN-XY-F12NS/ / / / / / D/188 Figure-8 Non-Armored Cable (60 Fiber Version Shown) MPDE Outer Jacket Stranded 3/16 Galvanized Steel Messenger Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F30

31 Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube, Armored For Aerial Applications 100% gel-free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km Figure-8 Armored 2-60 Fibers M-XXX-LA-XY-F12NS/ / / / / / D/109 Figure-8 Armored Cable (60 Fiber Version Shown) MPDE Outer Jacket Galvanized Steel Messenger Steel Tape Armoring Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F31

32 Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube, Non-Armored For Aerial Applications 100% gel free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km Figure-8 Non-Armored 2-60 Fibers M-XXX-LN-XY-F12NS/ / / / / / D/109 Figure-8 Non-Armored Cable (60 Fiber Version Shown) MPDE Outer Jacket Galvanized Steel Messenger Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F32

33 Indoor/Outdoor Stranded Loose Tube Cable Riser-Rated For Indoor/Outdoor Applications that Require a Riser Rating All meet critical NEC/CEC riser (OFNR) safety standards, eliminating the need for splice point at building entrance 100% gel free stranded loose tube cable reduces cable prep time Lightweight, small design is installer-preferred due to ease of handling Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Single Jacket 2-60 Fibers R-XXX-LN-XY-F12BK/25D / / / / / Fibers R-XXX-LN-XY-F12BK/25D / / / / / Fibers R-XXX-LN-XY-F12BK/25D / / / / / Fibers R-XXX-LN-XY-F12BK/25D / / / / / Fibers R-XXX-LN-XY-F12BK/25D / / / / / Fibers R-XXX-LN-XY-F12BK/25D / / / / / Fibers R-XXX-LN-XY-F12BK/25D / / / / / Singlemode/Multimode Composite (4-288 Fibers) R-XXX-LN-XY-F12BK/25D/AAaaa/BBbbb Refer to above specifications. Buffer Tubes repeat color sequence with tracer stripe F33 Riser-Rated Indoor/Outdoor Stranded Loose Tube Cable (72 Fiber Version Shown) PVC Outer Jacket Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member Strength Element 250 Micron Fiber Ripcord Flame Test Specifications Flame Test Listing NEC Type OFNR (ETL) and c(etl) Flame Test Standard UL-1666 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-409-CORE Issue 2; EN

34 Indoor/Outdoor Stranded Loose Tube Cable Plenum-Rated For Indoor/Outdoor Applications that Require a Plenum Rating Combines application spaces of building interconnect and plenum in a campus environment Dielectric design is lightweight, easy to access and does not require grounding 100% gel-free stranded loose tube cable reduces cable prep time Water blocking prevents moisture migration Temperature range is fully outside plant rated Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Single Jacket 2-60 Fibers P-XXX-LN-XY-F12BK/25D / / / / / Fibers P-XXX-LN-XY-F12BK/25D / / / / / Fibers P-XXX-LN-XY-F12BK/25D / / / / / Fibers P-XXX-LN-XY-F12BK/25D / / / / / Fibers P-XXX-LN-XY-F12BK/25D / / / / / Singlemode/Multimode Composite (4-144 Fibers) P-XXX-LN-CM-F12BK/25D/AAaaa/BBbbb Refer to above specifications. Buffer Tubes repeat color sequence with tracer stripe Plenum-Rated Indoor/Outdoor Stranded Loose Tube Cable (72 Fiber Version Shown) Plenum-Rated Outer Jacket Water Swellable Tape 2.5mm Gel Free Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fiber Ripcord (1) Flame Test Specifications Flame Test Listing NEC Type OFNP (ETL) and c(etl) Flame Test Standard NFPA-262 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-409-CORE Issue 2; EN F34

35 Indoor/Outdoor FiberGuard TM Stranded Loose Tube Cable Riser-Rated For Indoor/Outdoor Applications that Require a Riser Rating Cables are protected with an interlocking armor to shield against damage Well suited for construction and renovations, heavy industry and high security area applications Aluminum interlocking armor with overall jacket NEC/CEC compliant Outstanding mechanical protection for sensitive cables combined with excellent flexibility Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Buffer Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm inch/cm Short Term Long Term kft km 2-60 Fibers R-XXX-LZ-XY-FZZBK/25D / / / / / Fibers R-XXX-LZ-XY-FZZBK/25D / / / / / Fibers R-XXX-LZ-XY-FZZBK/25D / / / / / Fibers R-XXX-LZ-XY-FZZBK/25D / / / / / Fibers R-XXX-LZ-XY-FZZBK/25D / / / / / Fibers R-XXX-LZ-XY-FZZBK/25D / / / / / Fibers R-XXX-LZ-XY-FZZBK/25D / / / / / Singlemode/Multimode Composite (4-288 Fibers) R-XXX-LZ-XY-FZZBK/25D/AAaaa/BBbbb Refer to above specifications. Buffer Tubes repeat color sequence with tracer stripe Riser-Rated Indoor/Outdoor Stranded Loose Tube Cable (72 Fiber Version Shown) Riser-Rated Outer Jacket Interlocking Aluminum Armor Riser-Rated Inner Jacket Strength Elements Water Swellable Tape Dielectric Strength Member 250 Micron Fiber 2.5 mm Gel Free Buffer Tubes Ripcord(1) Flame Test Specifications Flame Test Listing NEC Type OFCR (ETL) and c(etl) Flame Test Standard UL-1666 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 483 lbf/in (85 N/mm) FOTP-41; IEC ; Sec. 7 Flex 25 Cycles FOTP-24; IEC ; Sec. 10 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-409-CORE Issue 2; EN F35

36 Indoor/Outdoor FiberGuard TM Stranded Loose Tube Cable Plenum-Rated For Indoor/Outdoor Applications that Require a Plenum Rating Cables are protected with an interlocking armor to shield against damage Well suited for construction and renovations, heavy industry and high security area applications Aluminum interlocking armor with overall jacket 100% gel-free stranded loose tube cable reduces cable prep time Outstanding mechanical protection for sensitive cables combined with excellent flexibility Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Buffer Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm inch/cm Short Term Long Term kft km 2-60 Fibers P-XXX-LZ-XY-FZZBK/25D / / / / / Fibers P-XXX-LZ-XY-FZZBK/25D / / / / / Fibers P-XXX-LZ-XY-FZZBK/25D / / / / / Fibers P-XXX-LZ-XY-FZZBK/25D / / / / / Fibers P-XXX-LZ-XY-FZZBK/25D / / / / / Singlemode/Multimode Composite (4-288 Fibers) P-XXX-LZ-XY-FZZBK/25D/AAaaa/BBbbb Refer to above specifications. Buffer Tubes repeat color sequence with tracer stripe Plenum-Rated Indoor/Outdoor Stranded Loose Tube Cable (72 Fiber Version Shown) Plenum-Rated Outer Jacket Interlocking Aluminum Armor Plenum-Rated Inner Jacket Strength Elements Water Swellable Tape Dielectric Strength Member 250 Micron Fiber 2.5 mm Gel Free Buffer Tubes Ripcord(1) Flame Test Specifications Flame Test Listing NEC Type OFCP (ETL) and c(etl) Flame Test Standard NFPA-262 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 483 lbf/in (85 N/mm) FOTP-41; IEC ; Sec. 7 Flex 25 Cycles FOTP-24; IEC ; Sec. 10 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S ; Telcordia GR-409-CORE Issue 2; EN F36

37 Outside Plant Central Tube Cable Armored and All-Dielectric Designs For Buried/Underground/Aerial Applications Robust constructions offer excellent protection of fibers Provides easy access to the fibers Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Product Type/ Catalog Subunits Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Armored O-XXX-CA-XY-F12NS / / / / / Fibers, 4mm Tube Fibers, 6mm Tube O-XXX-CA-XY-F12NS / / / / / Fibers, 8mm Tube O-XXX-CA-XY-F12NS / / / / / All-Dielectric O-XXX-CN-XY-F12NS / / / / / Fibers, 4mm Tube Fibers, 6mm Tube O-XXX-CN-XY-F12NS / / / / / Fibers, 8mm Tube O-XXX-CN-XY-F12NS / / / / / Singlemode/Multimode O-XXX-CA-CM-F12NS/AAAaa/BBbbb Refer to above specifications. Composite (4-96 Fibers) O-XXX-CN-CM-F12NS/AAaaa/BBbbb (Tube size will vary depending on fiber count/configuration.) Central Tube Armored Cable (24 Fiber Version Shown) Steel RSM (2) Ripcord for Armor Access (2) PE Outer Jacket Gel 4.0 mm Buffer Tube Fiber Thread 250 Micron Fibers Steel Armor Ripcord for Jacket Access (2) Central Tube Non-Armored All-Dielectric Cable (36 Fiber All-Dielectric Version Shown) Rigid RSM (2) PE Outer Jacket Water-Blocking Tape Gel 6.0 mm Buffer Tube Fiber Threads 250 Micron Fibers Ripcord for Jacket Access (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression (Dielectric) 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Compression (Armored) 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +70 (+140 C) FOTP-81; IEC , Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F37

38 Indoor/Outdoor Central Tube Cables Riser-Rated For Indoor/Outdoor Applications that Require a Riser Rating All meet critical NEC/CEC riser (OFNR) safety standards eliminating the need for splice point at building entrance Arid-Core water blocking technology helps protect fibers from moisture Standard color-coding on fibers helps ease installation Robust constructions offer excellent protection of fibers Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Single Jacket 2-24 Fibers, 4mm Tube R-XXX-CN-XY-F12BK / / / / / Indoor/Outdoor Central Tube Cable (24 Fiber Version Shown) Rigid RSM (2) PVC Outer Jacket Flexible Strength Elements Gel 4.0mm Buffer Tube 250 Micron Fibers Fiber Threads Ripcord for Jacket Access (2) Flame Test Specifications Flame Test Listing NEC Type OFNR (ETL) and c(etl) Flame Test Standard UL-1666 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Strain See long & short tensile loads FOTP-33; IEC ; Sec. 5 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-409-CORE Issue 2; EN F38

39 Outside Plant Drop Cable Armored Design For Buried/Underground/Aerial Applications Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Small, lightweight cable increases ease of installation, routing and termination (no preferential bend) Cost effective, low fiber count cable for outside plant applications Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Subunits Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Armored 1-12 Fibers O-XXX-DA-XY-F12NS / / / / / Singlemode/Multimode O-XXX-DA-CM-F12NS/AAaaa/BBbbb Composite (4-12 Fibers) Refer to above specifications. *This design is also available with a ripcord for applications where mid-span access is important (O-XXX-DA-XY-F12NS/BP) 8F Bend Insensitive, Singlemode Fiber* *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter Drop Armored Cable (12 fiber version shown) MDPE Outer Jacket Steel Armor Fiberglass Strength Elements 3.0mm Buffer Tube Aramid Strength Elements Gel 250 Micron Fibers Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC ; Sec. 17 ANSI/ICEA S RUS/RDUP 7 CFR RD Telecommunications Program Listed F39

40 Outside Plant Drop Cable All-Dielectric Design For Buried/Underground/Aerial Applications Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Small, lightweight cable increases ease of installation, routing and termination Cost effective, low fiber count cable for outside plant applications An outstanding choice when space is at a premium Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km All-Dielectric 1-12 Fibers O-XXX-DN-XY-F12NS / / / / / Singlemode/Multimode Composite (4-12 Fibers) O-XXX-DN-CM-F12NS/AAaaa/BBbbb Refer to above specifications. 8F Bend-Insensitive, Singlemode Fiber* Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter All-Dielectric Drop Cable (12 fiber version shown) PE Outer Jacket Rigid RSM (2) Strength Elements 3.0 mm Buffer Tube Gel 250 Micron Fibers Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC ; Sec. 17 ANSI/ICEA S F40

41 Self-Support Non-Armor Figure-8 Outdoor Drop Cable 1-6 Fiber Arid-Core Construction For Aerial Applications Cost effective, low fiber count cable for outside plant applications Figure-8 cable designed for extended span capability Small, very flexible cable allowing for increased ease of installation, routing and termination The legs can be easily separated as needed Fiber leg was designed to function as a self-sufficient cable once separated from the messenger Product Type/ Catalog Diameter Cable Diameter Minimum Bend Radius Max Tensile Load Weight Fiber Count Number Over Messenger Height Over Fiber Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm Lbs/N Lbs/N kft km Figure-8 Drop 1-6 Fibers M-XXX-MN-XY-FZZNS/ 0.17/ / / / / / / G/109 8F Bend-Insensitive, Singlemode Fiber* Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter Figure-8 Drop Cable (6 fiber version shown) Low Density Polyethylene Outer Jacket Solid Steel Messenger Strength Elements 2.5 mm Gel Filled Buffer Tube 250 Micron Fibers Rigid Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC ; Sec. 17 ANSI/ICEA S RUS/RDUP 7 CFR RD Telecommunications Program Listed F41

42 Outside Plant Self-Supporting Figure-8 Drop Cable 1-12 Fiber Arid-Core Construction For Aerial Applications Small, lightweight cable allowing for increased ease of installation, routing and termination Cost effective, low fiber count cable for outside plant applications Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Solid steel messenger member for simplified aerial applications Flexible design allows ease of routing and placement Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Diameter Cable Diameter Minimum Bend Radius Max Tensile Load Weight Fiber Count Number Over Messenger Height Over Fiber Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm Lbs/N Lbs/N kft km Figure-8 Drop 1-12 Fibers M-XXX-DN-XY-FZZNS/ 0.13/ / / / / / / GSM/40T 8F Bend-Insensitive, Singlemode Fiber* Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter Figure-8 Drop Cable (2 fiber version shown) MDPE Outer Jacket Messenger Wire Strength Elements Ripcord (1) 4.0 mm Buffer Tube Gel 250 Micron Fibers Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC ; Sec. 17 ANSI/ICEA S RUS/RDUP 7 CFR RD Telecommunications Program Listed F42

43 Outside Plant Self-Supporting Figure-8 Mini-Drop Cable 1-6 Fiber Arid-Core Construction Copper Clad Steel Messenger For Underground/Conduit Applications Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Small, lightweight cable increases ease of installation, routing and termination Cost effective, low fiber count cable for outside plant applications Solid steel messenger member can be used for toning Flexible design allows ease of routing and placement Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Diameter Cable Diameter Minimum Bend Radius Max Tensile Load Weight Fiber Count Number Over Messenger Height Over Fiber Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm Lbs/N Lbs/N kft km Figure-8 Drop 1-12 Fibers M-XXX-MN-XY-F12NS/ 0.16/ / / / / / / CCS 8F Bend-Insensitive, Singlemode Fiber* Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter Figure-8 Mini-Drop Cable (6 fiber version shown) Linear Low Density Polyethylene Outer Jacket Solid Steel Messenger 2.5mm Gel Filled Buffer Tube 250 Micron Fibers Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC ; Sec. 17 ANSI/ICEA S RUS/RDUP 7 CFR RD Telecommunications Program Listed F43

44 Outside Plant All-Dielectric Flat Drop Cable 1-12 Fiber Arid-Core Construction Aerial Self-Support or Direct Burial For Aerial Applications All dielectric cable design, which requires no bonding or grounding Compatible with industry standard hanging hardware Cost effective, low fiber count cable for outside plant applications Small, lightweight cable increases ease of installation, routing and termination Product Type/ Catalog Cable Outer Cable Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/cm inch/cm lbs/n lbs/n kft km All-Dielectric Flat Drop 1-12 Fibers O-XXX-DF-XY-F12NS 0.32/ / / / / / Figure-8 Mini-Drop Cable (12 fiber version shown) MDPE Outer Jacket GRP Rods 2.0mm Buffer Tube 250 Micron Fibers Ripcords (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC ; Sec. 17 ANSI/ICEA S RUS/RDUP 7 CFR RD Telecommunications Program Listed F44

45 Outside Plant All-Dielectric Flat Drop Cable 1-12 Fiber Arid-Core Construction Aerial Self-Support For Underground/Conduit Applications Incorporated tone wire designed for tone locating when digging Cost effective, low fiber count cable for outside plant applications Small, lightweight cable increases ease of installation, routing and termination Tone wire can be easily separated as needed Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Product Type/ Catalog Cable Outer Cable Msg. Jkt. Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Outer Dia. Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/mm inch/cm inch/cm lbs/n kft km All-Dielectric Flat Drop 1-12 Fibers O-XXX-DF-HY-F12NS/ 0.40/ / / / / / / XYXXX/1x24AWG Figure-8 Mini-Drop Cable (12 fiber version shown) 24-awg Copper Conductor MDPE Outer Jacket GRP Rods 2.0mm Buffer Tube 250 Micron Fibers Ripcords (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC ; Sec. 17 ANSI/ICEA S RUS/RDUP 7 CFR RD Telecommunications Program Listed F45

46 LSZH Indoor/Outdoor Cable Non-Armored, All-Dielectric For Indoor/Outdoor Drop Applications that Require a LSZH Rating Black jackets are UV-stable for outdoor use yet meet critical NEC type safety standards OFNR-LS (ETL) and C(ETL) Also meets many international flame ratings such as IEC , IEC , IEC , IEC , IEC and NES 713 Riser rating eliminates splice points at the building entrance Arid-Core water blocking technology helps protect fibers from moisture Low-Smoke Zero-Halogen (LSZH) gives added protection to building occupants and equipment Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Single Jacket 1-12 Fibers Z-XXX-DN-XY-F12BK/ / / / / / G Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Single Jacket 1-24 Fibers Z-XXX-DN-XY-F12BK / / / / / LSZH All-Dielectric Indoor/Outdoor Cable (12 Fiber, 4.0 mm Tube Version Shown) FRPE Outer Jacket Fiberglass Strength Elements 4.0 mm Gel Filled Buffer Tube 250 Micron Fibers Ripcord Flame Test Specifications Flame Test Listing NEC Type OFNR-LS (ETL) and c(etl) Flame Test Standard UL-1666, UL-1685, IEC , IEC , IEC , IEEE 383 Installation Temperature -4 to +158 F (-20 to +70 C) Operating Temperature -4 to +158 F (-20 to +70 C) Storage Temperature -4 to +167 F (-20 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC ; Sec. 17 Heat Age -4 to +185 F (-20 to +85 C) N/A Low High Bend -4 to +140 F (-20 to +60 C) FOTP-28; IEC ; Sec. 28 Temperature Cycle -4 to +158 F (-20 to +70 C) 24 Hours ANSI/ICEA S F46

47 ConQuest Toneable Conduit TM Installed with Central Tube Fiber Optic Products Fiber In ConQuest Toneable Conduit Cuts Installation Effort and Costs High strength 18 gauge copper clad steel tone wire saves installation dollars Moisture resistant polymer coated tone wire accurately detectable over various depths and lengths Tone wire embedded in the wall of the HDPE conduit results in easy wire removal Internally reinforced HDPE wall works with standard conduit connections Cable Type/ Fiber Part Number & Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count Conduit Description Weight (kft) Conduit OD Thicknesses SDR 11 SDR 13.5 SCH 40 Central Tube O-XXX-CN-XY-F12NS SDR 11 or Dielectric Specify Conduit OD, 63 lbs. 1 1 / 4 SDR 11 or Fibers Wall Thickness and Color 1 1 / 2 SDR 11 or SDR 13.5 or SCH Central Tube O-XXX-CN-XY-F12NS SDR 11 or Dielectric Specify Conduit OD, 86 lbs. 1 1 / 4 SDR 11 or Fibers Wall Thickness and Color 1 1 /2 SDR 11 or SDR 13.5 or SCH Central Tube O-XXX-CN-XY-F12NS SDR 11 or Dielectric Specify Conduit OD, 110 lbs. 1 1 / 4 SDR 11 or Fibers Wall Thickness and Color 1 1 / 2 SDR 11 or SDR 13.5 or SCH Other cables and wall sizes may be available upon request. For more information, please see the Conduit section of this catalog. * Weight does not include reel. Central Tube Fiber-In-Conduit (24 Fiber Construction in Toneable Conduit Shown) Copper Clad Steel Tone Wire High-Grade Polyethylene Conduit Silicon-Based Lubricant Central Tube Cable F47

48 ConQuest Toneable Conduit TM Pre-Installed with CommScope Dry Loose Tube Fiber Optic Cable Fiber-In-Conduit All of CommScope s fiber cables can be pre-installed in conduit, including the gel free, Dry Loose Tube cable. Available in five different diameters - 3 /4, 1, 1 1 /4, 1 1 /2 and 2 and three different wall thicknesses - SDR 11, SDR 13.5 and SCH 40. For more information or specifications on Fiber Optic cables, please visit our website at Cable Type/ Fiber Part Number & Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count Conduit Description Weight (kft) Conduit OD Thicknesses SDR 11 SDR 13.5 SCH 40 Dry (gel free) D-XXX-LN-XY-F12NS /4 SDR 11 or Loose Tube Specify Conduit OD, Wall 45 lbs. 1 SDR 11 or Dielectric Thickness and Color 1 1 / 4 SDR 11 or Fibers 1 1 / 2 SDR 11 or SDR 13.5 or SCH Dry (gel free) D-XXX-LN-XY-F12NS / 4 SDR 11 or Loose Tube Specify Conduit OD, Wall 49 lbs. 1 SDR 11 or Dielectric Thickness and Color 1 1 / 4 SDR 11 or Fibers 1 1 / 2 SDR 11 or SDR 13.5 or SCH Dry (gel free) D-XXX-LN-XY-F12NS /4 SDR 11 or Loose Tube Specify Conduit OD, Wall 64 lbs. 1 SDR 11 or Dielectric Thickness and Color 1 1 / 4 SDR 11 or Fibers 1 1 / 2 SDR 11 or SDR 13.5 or SCH Dry (gel free) D-XXX-LN-XY-F12NS SDR 11 or Loose Tube Specify Conduit OD, Wall 83 lbs. 1 1 / 4 SDR 11 or Dielectric Thickness and Color 1 1 / 2 SDR 11 or Fibers 2 SDR 13.5 or SCH Dry (gel free) D-XXX-LN-XY-F12NS / 4 SDR 11 or Loose Tube Specify Conduit OD, Wall 107 lbs. 1 1 / 2 SDR 11 or Dielectric Thickness and Color 2 SDR 13.5 or SCH Fibers Dry (gel free) D-XXX-LN-XY-F12NS /4 SDR 11 or Loose Tube Specify Conduit OD, Wall 90 lbs. 1 1 / 2 SDR 11 or Dielectric Thickness and Color 2 SDR 13.5 or SCH Fibers Dry (gel free) D-XXX-LN-XY-F12NS /4 SDR 11 or Loose Tube Specify Conduit OD, Wall 122 lbs. 1 1 /2 SDR 11 or Dielectric Thickness and Color 2 SDR 13.5 or SCH Fibers Other cables and wall sizes may be available upon request. * Weight does not include reel. Dry Loose Tube Fiber-In-Conduit (72 Fiber Construction in Toneable Conduit Shown) Copper Clad Steel Tone Wire High-Grade Polyethylene Conduit Silicon-Based Lubricant Dry Loose Tube Cable * Weight does not include reel. Other cables and wall sizes may be available upon request. F48

49 ConQuest Toneable Conduit TM Pre-Installed with CommScope Arid-Core Fiber Optic Cable Fiber-In-ConQuest Toneable Conduit Cuts Installation Effort and Costs All of CommScope s fiber cables can be pre-installed in conduit, including the Arid-Core Loose Tube cable. Available in five different diameters - 3 /4, 1, 1 1 /4, 1 1 /2 and 2 and three different wall thicknesses - SDR 11, SDR 13.5 and SCH 40. For more information or specifications on Fiber Optic cables, please visit our website at Cable Type/ Fiber Part Number & Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count Conduit Description Weight (kft) Conduit OD Thicknesses SDR 11 SDR 13.5 SCH 40 Arid-Core O-XXX-LN-XY-F12NS/25T /4 SDR 11 or Loose Tube Specify Conduit OD, Wall 48 lbs. 1 SDR 11 or Dielectric Thickness and Color 1 1 / 4 SDR 11 or Fibers 1 1 / 2 SDR 11 or SDR 13.5 or SCH Arid-Core O-XXX-LN-XY-F12NS/25T /4 SDR 11 or Loose Tube Specify Conduit OD, Wall 52 lbs. 1 SDR 11 or Dielectric Thickness and Color 1 1 / 4 SDR 11 or Fibers 1 1 / 2 SDR 11 or SDR 13.5 or SCH Arid-Core O-XXX-LN-XY-F12NS/25T /4 SDR 11 or Loose Tube Specify Conduit OD, Wall 69 lbs. 1 SDR 11 or Dielectric Thickness and Color 1 1 / 4 SDR 11 or Fibers 1 1 / 2 SDR 11 or SDR 13.5 or SCH Arid-Core O-XXX-LN-XY-F12NS/25T SDR 11 or Loose Tube Specify Conduit OD, Wall 89 lbs. 1 1 / 4 SDR 11 or Dielectric Thickness and Color 1 1 / 2 SDR 11 or Fibers 2 SDR 13.5 or SCH Arid-Core O-XXX-LN-XY-F12NS/25T / 4 SDR 11 or Loose Tube Specify Conduit OD, Wall 114 lbs. 1 1 / 2 SDR 11 or Dielectric Thickness and Color 2 SDR 13.5 or SCH Fibers Arid-Core O-XXX-LN-XY-F12NS/25T / 4 SDR 11 or Loose Tube Specify Conduit OD, Wall 102 lbs. 1 1 / 2 SDR 11 or Dielectric Thickness and Color 2 SDR 13.5 or SCH Fibers Arid-Core O-XXX-LN-XY-F12NS/25T / 4 SDR11 or Loose Tube Specify Conduit OD, Wall 138 lbs. 1 1 / 2 SDR 11 or Dielectric Thickness and Color 2 SDR 13.5 or SCH Fibers Other cables and wall sizes may be available upon request. * Weight does not include reel. Arid-Core Loose Tube Fiber-In-Conduit (72 Fiber Construction in Toneable Conduit Shown) Copper Clad Steel Tone Wire High-Grade Polyethylene Conduit Silicon-Based Lubricant Arid-Core Loose Tube Cable F49 * Weight does not include reel. Other cables and wall sizes may be available upon request.

50 ConQuest Conduit Pre-Installed with CommScope Fiber Drop Cable Fiber-In-Conduit All of CommScope s fiber cables can be pre-installed in conduit, including the Fiber Drop cables. Available in 1 / 2 or 3 / 4 and two different wall thicknesses - SDR 11 or SDR For more information or specifications on Fiber Optic cables, please visit our website at Figure-8 Fiber Drop Cable In Conduit Cable Type/ Catalog Number Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count (Description) Weight (kft) Conduit OD Thickness SDR 11 SDR 13.5 Fiber Drop M-XXX-MN-XY-FZZNS/CCS 0.16 x 0.31 ½ SDR 11 or Messengered (Solid Steel Construction) 27 lbs. ¾ Fibers Specify Conduit OD, Wall Thickness and Color NOTE: The solid or stranded steel messengers can be used to pull the cable during installation, and for locating after burial. All-Dielectric Flat Drop Cable In Conduit Cable Type/ Catalog Number Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count (Description) Weight (kft) Conduit OD Thickness SDR 11 SDR 13.5 Flat Drop O-XXX-DF-XY-FZZNS 0.18 x 0.32 ½ SDR 11 or Fibers Specify Conduit OD, 30 lbs. ¾ Wall Thickness and Color *Other size conduits may be available upon request. * Weight does not include reel. Toneable Flat Drop Cable In Conduit Cable Type/ Catalog Number Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count (Description) Weight (kft) Conduit OD Thickness SDR 11 SDR 13.5 Toneable Flat Drop 1-12 Fibers O-XXX-DF-HY-FZZNS/XYZZZ/ 0.18 x 0.40 ¾ SDR 11 or X12AWG 38 lbs. 1 SDR 11 or Specify Conduit OD, Wall Thickness and Color *Other size conduits may be available upon request. * Weight does not include reel. 5M LaserCore Solid Steel Messengered Fiber Drop In ConQuest Conduit (6 Fiber Construction Shown) High-Grade Polyethylene Conduit Silicon-Based Lubricant All-Dielectric Flat Drop Cable in ConQuest Conduit (6 Fiber Construction Shown) High-Grade Polyethylene Conduit Silicon-Based Lubricant Toneable Flat Drop Cable in ConQuest Conduit (6 Fiber Construction Shown) High-Grade Polyethylene Conduit Silicon-Based Lubricant Messengered Fiber Drop Cable Flat Drop Cable Toneable Flat Drop Cable Drawings are not to scale Specifications are subject to change without notice F50

51 CommScope Hybrid Cable Fiber/6 Series Drop Cable (BrightWire ) Features & Benefits The BrightWire drop cable leg is designed to carry video The optical leg is designed to carry voice and data Only a single installation is required Small, very flexible cable allowing for increased ease of installation, routing and termination The legs can be easily separated as needed Product Type/ Catalog Cable Outer Cable Component Sub Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Jacket OD Units Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm lbs/n lbs/n kft km 1-12 Fibers O-XXX-DN-HY-F12NS/ 0.26/ / / / / / / G/XYXXX/F6SSBW Jacket Color: Black Medium Density Polyethylene Arid-Core Construction Fiber Coax Hybrid Cable (12 Fiber Version Shown) LDPE Jacket BrightWire Aluminum Braid Anti-Corrosion Tape BrightWire Aluminum Braid Anti-Corrosion Tape 18 AWG Copper Clad Steel Dielectric Fiberglass Strength Elements 4.0mm Buffer Tube Gel 250 Micron Fibers Ripcord Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S F51

52 CommScope Self-Support Figure-8 Hybrid Cable Fiber/6 Series Drop Cable (BrightWire ) Features & Benefits The BrightWire drop cable leg is designed to carry video The optical leg is designed to carry voice and data Only a single installation is required Small, very flexible cable allowing for increased ease of installation, routing and termination The legs can be easily separated as needed Product Type/ Catalog Cable Outer Cable Messenger Copper Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Jacket OD Comp./ Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm Buffer Tubes inch/cm inch/cm lbs/n lbs/n kft km 1-12 Fibers M-XXX-DN-HY-F12NS/ 0.26/ / /3.4 1/1 3.9/ / / / XYXXX/40T/F6SSBW/ GSM Jacket Color: Black Linear Low Density Polyethylene Arid-Core Construction Self-Supporting Hybrid Cable (12 Fiber Version with Messenger Shown) Galvanized Steel Messenger LDPE Jacket BrightWire Aluminum Braid Anti-Corrosion Tape BrightWire Aluminum Braid Anti-Corrosion Tape CU/Steel Dielectric 4.0mm Buffer Tube Strength Elements Gel Ripcord (1) 250 Micron Fibers Installation Temperature Operating Temperature Storage Temperature -22 to +158 F (-30 to +70 C) -40 to +158 F (-40 to +70 C) -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S F52

53 Hybrid Single Jacket Outdoor Cable Armored Features & Benefits Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection Designed for tone locating when digging and for communications Used for powering optoelectrical equipment down the line Provides line fault detection and location Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count/Pair Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km 2-48 Fibers O-XXX-LA-HY-FZZNS/ 1 Pair XYXXX/1X22UTP / / / / / Fibers O-XXX-LA-HY-FZZNS/ / / / / / Pair XYXXX/1X22UTP Fibers O-XXX-LA-HY-FZZNS/ / / / / / Pair XYXXX/1X22UTP Fibers O-XXX-LA-HY-FZZNS/ / / / / / Pair XYXXX/1X22UTP Fibers O-XXX-LA-HY-FZZNS/ / / / / / Pair XYXXX/1X22UTP Fibers O-XXX-LA-HY-FZZNS/ / / / / / Pair XYXXX/1X22UTP Fibers O-XXX-LA-HY-FZZNS/ 1 Pair XYXXX/1X22UTP / / / / / Copper Twisted Pairs are identified with standard color coding: 1/White/Blue, 2/White/Orange, 3/White/Green, 4/White/Brown, 5/White/Grey Hybrid Single Jacket Armored Cable (108 Fiber Version Shown) PE Outer Jacket 22 AWG UTP (1) Water Swellable Tape Steel Tape Armoring Strength Elements Dielectric Strength Member Central Member Upjacket 3.0mm Gel Filled Buffer Tubes 250 Micron Fibers Ripcord (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F53

54 Hybrid Single Jacket Outdoor Cable All-Dielectric Features & Benefits Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Designed for communications and tone locating when digging Used for powering optoelectrical equipment down the line Provides line fault detection and location Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count/Pair Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km 2-48 Fibers 1 Pair O-XXX-LN-HY-FZZNS/ / / / / / XYXXX/1X22UTP Fibers O-XXX-LN-HY-FZZNS/ / / / / / Pair XYXXX/1X22UTP Fibers O-XXX-LN-HY-FZZNS/ 1 Pair XYXXX/1X22UTP Fibers O-XXX-LN-HY-FZZNS/ 1 Pair XYXXX/1X22UTP Fibers O-XXX-LN-HY-FZZNS/ 1 Pair XYXXX/1X22UTP Fibers O-XXX-LN-HY-FZZNS/ 1 Pair XYXXX/1X22UTP Fibers O-XXX-LN-HY-FZZNS/ 1 Pair XYXXX/1X22UTP / / / / / / / / / / / / / / / / / / / / / / / / / Copper Twisted Pairs are identified with standard color coding: 1/White/Blue, 2/White/Orange, 3/White/Green, 4/White/Brown, 5/White/Grey Hybrid Single Jacket All-Dielectric Cable (108 Fiber Version Shown) PE Outer Jacket 22 AWG UTP (1) Water Swellable Tape Strength Elements Dielectric Strength Member Central Member Upjacket 3.0mm Gel Filled Buffer Tubes 250 Micron Fibers Ripcord Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F54

55 Hybrid Single Jacket Outdoor Cable + Conductor Armored Features & Benefits Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection Designed for tone locating when digging Provides line fault detection and location Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count/Conductor Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km 2-48 Fibers 1-4 Conductors O-XXX-LA-HY-FZZNS/ / / / / / XYXXX/NX12AWG Fibers O-XXX-LA-HY-FZZNS/ / / / / / Conductors XYXXX/NX12AWG Fibers O-XXX-LA-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG Fibers O-XXX-LA-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG Fibers O-XXX-LA-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG Fibers O-XXX-LA-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG / / / / / / / / / / / / / / / / / / / / Fibers O-XXX-LA-HY-FZZNS/ / / / / / Conductors XYXXX/NX12AWG Copper Conductors Color Coding: Specified by customer F55 Hybrid Single Jacket All-Dielectric Cable (108 Fiber Version Shown) PE Outer Jacket Steel Tape Armoring Water Swellable Tape Strength Elements 3.0mm Gel Filled Buffer Tubes Dielectric Strength Member 12 AWG Copper Conductor White (1) 250 Micron Fibers Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN

56 Hybrid Single Jacket Outdoor Cable + Conductor All-Dielectric Features & Benefits Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Designed for tone locating when digging Provides line fault detection and location Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count/Conductor Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km 2-48 Fibers 1-4 Conductors O-XXX-LN-HY-FZZNS/ / / / / / XYXXX/NX12AWG Fibers O-XXX-LN-HY-FZZNS/ / / / / / Conductors XYXXX/NX12AWG Fibers O-XXX-LN-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG Fibers O-XXX-LN-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG Fibers O-XXX-LN-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG Fibers O-XXX-LN-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG / / / / / / / / / / / / / / / / / / / / Fibers O-XXX-LN-HY-FZZNS/ / / / / / Conductors XYXXX/NX12AWG Copper Conductors are identified with a standard color coding: 1/Red, 2/Black, 3/Green, 4/Brown Hybrid Single Jacket All-Dielectric Cable (108 Fiber Version Shown) PE Outer Jacket Water Swellable Tape Strength Elements 3.0mm Gel Filled Buffer Tubes Dielectric Strength Member 12 AWG Copper Conductor White (1) 250 Micron Fibers Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN F56

57 Single Jacket Single Armor Outdoor Cable + Conductor Armored and Non-Armored, All Dielectric Features & Benefits Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Designed for tone locating when digging Provides line fault detection and location Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Armored Fibers O-XXX-LA-HY-F24NS/ / / / / / Conductors XYXXX/NX12AWG Fibers O-XXX-LA-HY-F24NS/ / / / / / Conductors XYXXX/NX12AWG All-Dielectric Fibers O-XXX-LN-HY-F24NS/ / / / / / Conductors XYXXX/NX12AWG Fibers O-XXX-LN-HY-F24NS/ / / / / / Conductors XYXXX/NX12AWG *Weights were calculated using a single 12 AWG conductor. Providing number of conductors, custom tables are available upon request. Buffer Tubes repeat color sequence with tracer stripe Copper Conductors Color Coding: Specified by customer F57 Single Jacket Single Armor Outdoor Cable + Conductor (552 Fiber Armored,1 x 12 AWG Version Shown) 12 AWG Copper Conductor (1) PE Outer Jacket Steel Tape Armor Strength Elements Water Swellable Tape 3.5mm Gel Filled Buffer Tubes 250 Micron Fibers Dielectric Strength Member Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC ; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC ; Sec. 17 ANSI/ICEA S ; Telcordia GR-20-CORE Issue 3; EN

58 Indoor/Outdoor LSZH Distribution Cable Low-Smoke Zero-Halogen, Riser-Rated LSZH Construction Permits Riser Applications as Well Black jackets are UV-stable for outdoor use yet meet critical NEC/CEC riser (OFNR and OFN-LS) safety standards Riser rating eliminates splice points at the building entrance Arid-Core water blocking technology helps protect fibers from moisture Low-Smoke Zero-Halogen (LSZH) gives added protection to building occupants and equipment Tight buffered construction reduces installation cost Fiber Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Count Number Diameter Loaded Unloaded Short term Long term lbs/kft kg/km 2 Fibers (no central member) Z-ØØ2-DS-XY-FSUBK 0.15/ / / / / Fibers (no central member) Z-ØØ4-DS-XY-FSUBK 0.20/ / / / / Fibers Z-ØØ6-DS-XY-FSUBK 0.22/ / / / / Fibers Z-ØØ8-DS-XY-FSUBK 0.25/ / / / / Fibers Z-Ø12-DS-XY-FSUBK 0.28/ / / / / Fibers Z-Ø18-DS-XY-FSUBK 0.31/ / / / / Fibers Z-Ø24-DS-XY-FSUBK 0.34/ / / / / Fibers Z-Ø36-DS-XY-FMUBK 0.70/ / / / / Fibers Z-Ø48-DS-XY-FMUBK 0.80/ / / / / Fibers Z-Ø60-DS-XY-FMUBK 0.87/ / / / / Fibers Z-Ø72-DS-XY-FMUBK 0.95/ / / / / Singlemode/Multimode Z-ØØØ-DS-CM-FSUBK/AAaaa/BBbbb Custom design - sizes/specs will vary depending on fiber count Composite (4-72 Fibers) Z-ØØØ-DS-CM-FMUBK/AAaaa/BBbbb Tight Jacket Color: UV Stabilized Black LSZH Indoor/Outdoor Riser-Rated Distribution Cable (Multi-Unit) (72 Fiber Version Shown) Low-Smoke Zero-Halogen (LSZH) Outer Jacket Triathlon Subunit with Arid-Core Central Strength Member Water Blocking Tapes Ripcord 12 Fiber Unit (Single Unit) LSZH Jacket Aramid Yarn Central Strength Member 900 Micron Tight-Buffered 250 Micron Fiber Ripcord Water Blocking Thread Mechanical Properties Description Specification Test Method Operating Temperature -40 to 158 F (-40 to 70 C) FOTP-3 Installation Temperature -22 to 158 F (-30 to 70 C) N/A Storage Temperature -40 to 167 F (-40 to 75 C) N/A Crush Resistance Exceeds 126 lbf/in (22 N/mm) FOTP-41 Impact Resistance Exceeds 4.34 lb ft (5.88 N m) FOTP-25 Flexing Exceeds 100 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premises cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. Water penetration performance meets the requirements of Telcordia GR-20-CORE, Issue 2. F58

59 Indoor/Outdoor LSZH Cordage Cable Low-Smoke Zero-Halogen, Riser-Rated LSZH Construction Permits Riser Applications as Well Black jackets are UV-stable for outdoor use yet meet critical NEC/CEC riser (OFNR and OFN-LS) safety standards Riser rating eliminates splice points at the building entrance Arid-Core water blocking technology helps protect fibers from moisture Low-Smoke Zero-Halogen gives added protection to building occupants and equipment Simplex and zipcord cables are available in a variety of sizes Designed for ease of handling and termination Cable Type/Unit Size Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./newtons kft km Simplex/1.6mm Z-ØØ1-SP-XY-F16BK 0.067/ / /3.0 35/156 11/ Simplex/2.5mm Z-ØØ1-SP-XY-F25BK 0.098/ / /3.0 60/267 18/ Simplex/2.9mm Z-ØØ1-SP-XY-F29BK 0.114/ / /3.0 60/267 18/ Zipcord/1.6mm Z-ØØ2-ZC-XY-F16BK x 0.138/ 2.0/ /3.0 70/311 21/ x 3.50 Zipcord/2.5mm Z-ØØ2-ZC-XY-F25BK x 0.201/ 2.50 x / /3.0 90/400 27/ Zipcord/2.9mm Z-ØØ2-ZC-XY-F29BK x 0.232/ 2.90 x / /3.0 90/400 27/ Interconnect/2.9mm Z-ØØ2-IC-XY-F29BK 0.114/ / /3.0 70/311 21/ Tight Buffer/Fiber Identification Colors: 1/Blue, 2/Orange Jacket Color: UV Stabilized Black Indoor/Outdoor LSZH Simplex Cable LSZH Riser Rated Outer Jacket Water Blocking System Aramid Yarn 900µm Tight Buffer 250µm Optical Fiber Indoor/Outdoor LSZH Zipcord Cable LSZH Riser Rated Outer Jacket Aramid Yarn Water Blocking System 900µm Tight Buffer 250µm Optical Fiber Indoor/Outdoor LSZH 2-Fiber Interconnect Cable LSZH Riser Rated Outer Jacket Aramid Yarn Water Blocking System 900µm Tight Buffer 250µm Optical Fibers Mechanical Properties Description Specification Test Method Operating Temperature -40 to 158 F (-40 to 70 C) FOTP-3 Installation Temperature -22 to 158 F (-30 to 70 C) N/A Storage Temperature -40 to 167 F (-40 to 75 C) N/A Crush Resistance Exceeds 57 lbf/in (10 N/mm) FOTP-41 Impact Resistance Exceeds 0.54 lbf ft (0.74 N m) FOTP-25 Flexing Exceeds 300 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premise cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. Water penetration performance meets the requirements of Telcordia GR-20-CORE, Issue 2. F59

60 Premise Riser-Rated Distribution Cable For Indoor Applications that Require a Riser Rating Meets critical NEC/CEC riser (OFNR) safety standards Colored-Coded and color-coded fibers help ease installation Outer Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Catalog Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./newtons kft km 2 Fibers R-ØØ2-DS-XY-FSUZZ 0.16/ / / / / Fibers R-ØØ4-DS-XY-FSUZZ 0.19/ / / / / Fibers R-ØØ6-DS-XY-FSUZZ 0.20/ / / / / Fibers R-ØØ8-DS-XY-FSUZZ 0.22/ / / / / Fibers R-Ø12-DS-XY-FSUZZ 0.24/ / / / / Fibers R-Ø18-DS-XY-FSUZZ 0.30/ / / / / Fibers R-Ø24-DS-XY-FSUZZ 0.33/ / / / / Fibers (3 subunits) R-Ø36-DS-XY-FMUZZ 0.58/ / / / / Fibers (4 subunits) R-Ø48-DS-XY-FMUZZ 0.63/ / / / / Fibers (5 subunits) R-Ø6Ø-DS-XY-FMUZZ 0.71/ / / / / Fibers (6 subunits) R-Ø72-DS-XY-FMUZZ 0.79/ / / / / Fibers (8 subunits) R-Ø96-DS-XY-FMUZZ 0.93/ / / / / Fibers (12 subunits) R-144-DS-XY-FMUZZ 1.03/ / / / / Singlemode/Multimode R-XXX-DS-CM-FSUOR/AAaaa/BBbbb Composite (4-144 Fibers) R-XXX-DS-CM-FMUOR/AAaaa/BBbbb Custom design - sizes/specs will vary depending on fiber count Tight Buffer/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Subunits are color-coded in the same manner. Riser Distribution Cable (Multi-Unit) (72 and 12 Fiber Versions Shown) Riser Rated Outer Jacket Core Wrap Tape Central Strength Member 12 Fiber Subunit Ripcord 12 Fiber Unit (Single Unit) Riser Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Ripcord Mechanical Properties Description Specification Test Method Operating Temperature -4 to 158 F (-20 to 70 C) FOTP-3 Installation Temperature -4 to 158 F (-20 to 70 C) N/A Storage Temperature -40 to 158 F (-40 to 70 C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 4.34 lb ft (5.88 N m) FOTP-25 Flexing Exceeds 100 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. F60

61 Premise Riser-Rated Cordage Cable Several Constructions Available for a Variety of Applications For Indoor Applications that Require a Riser Rating Meets critical NEC/CEC riser (OFNR) safety standards Simplex and zipcord cables are available in a variety of sizes Designed for ease of handling and termination Cable Type/Unit Size Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./newtons kft km Simplex/1.6mm R-ØØ1-SP-XY-F16ZZ 0.067/ / /3.0 35/156 11/ Simplex/2.0mm R-ØØ1-SP-XY-F20ZZ 0.079/ / /3.0 50/222 15/ Simplex/2.5mm R-ØØ1-SP-XY-F25ZZ 0.098/ / /3.0 60/267 18/ Simplex/2.9mm R-ØØ1-SP-XY-F29ZZ 0.114/ / /3.0 60/267 18/ Zipcord/1.6mm R-ØØ2-ZC-XY-F16ZZ x 0.138/ 2.0/ /3.0 70/311 21/ x 3.50 Zipcord/2.0mm R-ØØ2-ZC-XY-F20ZZ x 0.161/ 2.0/ /3.0 80/356 24/ x 4.10 Zipcord/2.5mm R-ØØ2-ZC-XY-F25ZZ x 0.201/ 2.0/ /3.0 90/400 27/ x 5.10 Zipcord/2.9mm R-ØØ2-ZC-XY-F29ZZ x 0.232/ 2.3/ /3.0 90/400 27/ x 5.90 Interconnect /2.9mm R-ØØ2-IC-XY-F29ZZ 0.114/ / /3.0 70/311 21/ ZZ = Standard Jacket Color YL (Yellow - Singlemode Cable) OR (Orange - Multimode or Composite Cable) AQ (Aqua - LaserCore Cable) Fiber Identification Colors: 1/Blue, 2/Orange Riser Simplex Cable Riser Rated Outer Jacket 900 µm Tight Buffer 250 µm Optical Fiber Aramid Yarn Riser Zipcord Cable Riser Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Riser 2-Fiber Interconnect Cable Riser Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Mechanical Properties Description Specification Test Method Operating Temperature -4 to 158 F (-20 to 70 C) FOTP-3 Installation Temperature -4 to 158 F (-20 to 70 C) N/A Storage Temperature -40 to 158 F (-40 to 70 C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 0.54 lb ft (0.74 N m) FOTP-25 Flexing Exceeds 300 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. F61

62 Premise Plenum-Rated Distribution Cable For Indoor Applications that Require a Plenum Rating Meets critical NEC/CEC plenum (OFNP) safety standards Color-coded subunits and color-coded fibers help ease installation Outer Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Catalog Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./newtons kft km 2 Fibers P-ØØ2-DS-XY-FSUZZ 0.15/ / / / / Fibers P-ØØ4-DS-XY-FSUZZ 0.17/ / / / / Fibers P-ØØ6-DS-XY-FSUZZ 0.19/ / / / / Fibers P-ØØ8-DS-XY-FSUZZ 0.20/ / / / / Fibers P-Ø12-DS-XY-FSUZZ 0.23/ / / / / Fibers P-Ø18-DS-XY-FSUZZ 0.31/ / / / / Fibers P-Ø24-DS-XY-FSUZZ 0.33/ / / / / Fibers (3 subunits) P-Ø36-DS-XY-FMUZZ 0.54/ / / / / Fibers (4 subunits) P-Ø48-DS-XY-FMUZZ 0.59/ / / / / Fibers (5 subunits) P-Ø6Ø-DS-XY-FMUZZ 0.68/ / / / / Fibers (6 subunits) P-Ø72-DS-XY-FMUZZ 0.75/ / / / / Fibers (8 subunits) P-Ø96-DS-XY-FMUZZ 0.91/ / / / / Fibers (12 subunits) P-144-DS-XY-FMUZZ 0.97/ / / / / Singlemode/Multimode P-XXX-DS-CM-FSUOR/AAaaa/BBbbb Composite (4-144 Fibers) P-XXX-DS-CM-FMUOR/AAaaa/BBbbb Custom design - sizes/specs will vary depending on fiber count Tight Buffer/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Subunits are color-coded for easy identification Plenum Distribution Cable (Multi-Unit) (72 and 12 Fiber Versions Shown) Plenum Rated Outer Jacket Central Strength Member 12 Fiber Subunit Ripcord 12 Fiber Unit (Single Unit) Riser Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Ripcord Mechanical Properties Description Specification Test Method Operating Temperature -4 to 158 F (-20 to 70 C) FOTP-3 Installation Temperature 32 to 158 F (0 to 70 C) N/A Storage Temperature -40 to 158 F (-40 to 70 C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 4.34 lb ft (5.88 N m) FOTP-25 Flexing Exceeds 100 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. F62

63 Premise Plenum-Rated Cordage Cable Several Constructions Available for a Variety of Uses For Indoor Applications that Require a Plenum Rating Meets critical NEC/CEC plenum (OFNP) safety standards Simplex and zipcord cables are available in a variety of sizes Designed for ease of handling and termination Cable Type/Unit Size Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./newtons kft km Simplex/1.6mm P-ØØ1-SP-XY-F16ZZ 0.067/ / /3.0 35/156 11/ Simplex/2.0mm P-ØØ1-SP-XY-F20ZZ 0.079/ / /3.0 50/222 15/ Simplex/2.5mm P-ØØ1-SP-XY-F25ZZ 0.098/ / /3.0 60/267 18/ Simplex/2.9mm P-ØØ1-SP-XY-F29ZZ 0.114/ / /3.0 60/267 18/ Zipcord/1.6mm P-ØØ2-ZC-XY-F16ZZ x 0.138/ 2.0/ /3.0 70/311 21/ x 3.50 Zipcord/2.0mm P-ØØ2-ZC-XY-F20ZZ x 0.161/ 2.0/ /3.0 80/356 24/ x 4.10 Zipcord/2.5mm P-ØØ2-ZC-XY-F25ZZ x 0.201/ 2.0/ /3.0 90/400 27/ x 5.10 Zipcord/2.9mm P-ØØ2-ZC-XY-F29ZZ x 0.232/ 2.3/ /3.0 90/400 27/ x 5.90 Interconnect/2.9mm P-ØØ2-IC-XY-F29ZZ 0.114/ / /3.0 70/311 21/ ZZ = Standard Jacket Color YL (Yellow - Singlemode Cable) OR (Orange - Multimode or Composite Cable) AQ (Aqua - LaserCore Cable) Fiber Identification Colors: 1/Blue, 2/Orange Plenum Simplex Cable Plenum Rated Outer Jacket 900 µm Tight Buffer 250 µm Optical Fiber Aramid Yarn Plenum Zipcord Cable Plenum Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Plenum 2-Fiber Interconnect Cable Plenum Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Mechanical Properties Description Specification Test Method Operating Temperature -4 to 158 F (-20 to 70 C) FOTP-3 Installation Temperature 32 to 158 F (0 to 70 C) N/A Storage Temperature -40 to 158 F (-40 to 70 C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 0.54 lb ft (0.74 N m) FOTP-25 Flexing Exceeds 300 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. F63

64 Fiber Optic Cable Packaging and Shipping Information Packaging and Shipping Fiber optic cable is packaged for shipment on wooden or composite reels. Each package contains only one continuous length of cable. The packaging is designed to prevent damage to the cable during shipping and handling. Fiber cable reels are protected with a reel wrap, the highest technology available today. This wrap is stronger, lighter and more environmentally friendly than other methods of lagging. In addition, reel wrap is simple to remove from the reel and readily disposable. All reel sizes between 35 and 78 inches will be blocked and palletized to help ensure safe arrival to the customer. Reels larger than 78 inches are placed on the rolling edge and securely fastened to the trailer during shipment. F Flange Diameter T Traverse Width D Drum Diameter Each reel is plainly marked to indicate the direction in which it should be rolled to prevent loosening of the cable on the reel. Method of Shipment CommScope s customary method of shipment of fiber optic cable from Claremont, North Carolina to the purchaser s site will vary depending on factors such as the size and number of cable reels, and the destination location. Shipper options include Federal Express, UPS, BAX, LTL motor freight carriers and CommScope s own fleet of trucks, Cable Transport. Some trucks within CommScope s fleet are equipped with Cargo Master equipment for ease in unloading cable reels on location where no loading dock is available. CommScope has red arm Cargo Masters, which can lift anything 2,500 pounds or less. CommScope also has white arm Cargo Masters which will lift anything up to 8,000 pounds that is on an 84 reel or smaller. These specially equipped trucks are available by request. International Packaging Products shipped outside the continental United States are protected with reel wrap, lagged with wood, and blocked and palletized (for reel sizes between 35 and 78 inches) or placed on the rolling edge and securely fastened to international shipping containers. F64

65 Fiber Optic Cable Packaging and Shipping Information Outside Plant Dry Stranded Loose Tube Armored (D-LA) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F F F F F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 35 x 16.5 x ,805 3,752 2,834 2,414 1,742 1,722 1, x 24 x ,706 6,008 4,988 3,838 3,101 3,101 2, x 22 x ,816 8,021 6,249 5,231 3,885 3,885 3, x 22 x ,058 13,828 10,597 8,624 6,868 6,868 5, x 24 x ,987 15,888 12,526 9,881 7,914 7,914 5, x 30 x ,681 20,988 16,528 12,973 10,548 10,548 7, x 30 x ,384 26,363 20,713 16,715 12,885 12,885 9, x 36 x ,603 34,883 27,084 21,831 17,174 17,174 13, x 36 x ,398 44,759 34,523 27,371 22,174 22,114 16, x 40 x ,951 56,558 43,978 35,569 27,634 27,634 20, x 40 x N/A 59,942 50,344 39,867 31,433 31,433 23, x 44 x 46 1,125 N/A N/A 59,910 56,045 42,748 42,748 33,491 All Units in Feet 2 Flange Clearance Outside Plant Dry Stranded Loose Tube Non-Armored (D-LN) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F F F F F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 35 x 16.5 x ,195 4,783 3,671 2,847 2,054 2,054 1, x 24 x ,572 7,784 6,029 4,566 3,683 3,683 2, x 22 x ,173 10,816 7,922 6,156 4,614 4,614 3, x 22 x ,027 17,654 12,932 10,648 7,832 7,832 6, x 24 x ,977 20,432 15,705 11,680 8,819 8,819 7, x 30 x ,256 27,346 20,773 15,736 11,903 11,903 9, x 30 x ,834 34,662 26,098 20,458 15,199 15,199 11, x 36 x ,165 45,550 34,589 26,798 20,008 20,008 15, x 36 x ,950 56,756 42,952 34,179 25,296 25,296 19, x 40 x N/A 59,942 54,434 42,065 33,135 33,135 23, x 40 x N/A N/A 59,910 48,310 37,275 37,275 27, x 44 x N/A N/A N/A 59,872 46,351 46,351 33,491 All Units in Feet 2 Flange Clearance Outside Plant Dry Loose Tube Double Jacket, Single Armor (D-L2) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F F F F F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 35 x 16.5 x ,407 2,110 1,735 1,449 1,191 1,191 N/A 42 x 24 x ,831 3,756 3,091 2,560 2,083 2,083 1, x 22 x ,328 5,145 3,963 3,289 2,684 2,684 2, x 22 x ,760 8,509 6,835 5,932 4,651 4,651 3, x 24 x ,464 9,727 7,874 6,517 5,595 5,595 4, x 30 x ,973 12,793 10,502 8,590 7,459 7,459 5, x 30 x ,505 16,490 13,106 10,960 9,034 9,034 7, x 36 x ,217 21,578 17,098 14,480 11,843 11,843 9, x 36 x ,917 27,071 22,003 19,034 15,108 15,108 11, x 40 x ,461 35,237 27,501 23,625 19,069 19,069 15, x 40 x ,206 39,508 31,272 27,115 22,231 22,231 17, x 44 x ,862 53,103 43,166 36,645 29,694 29,694 23,862 All Units in Feet 2 Flange Clearance F65 Reel Weights subject to change without notice.

66 Fiber Optic Cable Packaging and Shipping Information Outside Plant Stranded Loose Tube Armored (O-LA/25T) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F F F F F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@ x 16.5 x ,118 3,746 2,831 2,411 1,741 1,741 1, x 24 x ,832 6,121 5,097 3,836 3,099 3,099 2, x 22 x ,950 8,615 6,778 5,227 3,882 3,882 3, x 22 x ,045 14,008 10,761 8,615 6,861 6,861 5, x 24 x ,972 15,856 12,506 9,869 7,906 7,906 5, x 30 x ,663 21,265 16,786 12,960 10,539 10,539 7, x 30 x ,357 27,785 21,621 16,697 12,872 12,872 9, x 36 x ,572 36,172 28,238 21,809 17,158 17,158 12, x 36 x ,885 44,670 34,470 28,502 22,092 22,092 16, x 40 x ,951 57,121 44,507 35,530 27,607 27,607 20, x 40 x N/A 59,942 50,944 41,293 31,401 31,401 23, x 44 x N/A N/a 59,910 55,980 43,342 43,342 33,491 All Units in Feet 2 Flange Clearance Outside Plant Stranded Loose Tube Non-Armored (O-LN/25T) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F F F F F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 35 x 16.5 x ,189 4,773 3,666 2,8473 2,052 2,052 1, x 24 x ,565 7,772 6,023 4,562 3,681 3,681 2, x 22 x ,162 10,797 7,911 6,149 4,611 4,611 3, x 22 x ,002 17,847 13,878 10,633 7,825 7,825 6, x 24 x ,947 20,693 15, ,001 9,011 7, x 30 x ,221 27, ,579 11,895 11,895 9, x 30 x ,785 34,583 26,054 20,428 15,186 15,186 11, x 36 x ,108 45,458 34,537 26,762 19,992 19,992 15, x 36 x ,952 56,628 42,879 34,127 25,274 25,274 19, x 40 x N/A 59,942 54,346 44,128 33,108 33,108 23, x 40 x N/A N/A 59,910 48,896 37,242 37,242 27, x 44 x N/A N/A N/A 59,873 46,351 46,351 33,491 All Units in Feet Outside Plant Loose Tube Double Jacket, Single Armor (O-L2/25T) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F F F F F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 35 x 16.5 x ,407 2,110 1,735 1,449 1,191 1,191 N/A 42 x 24 x ,831 3,756 3,091 2,560 2,083 2,083 1, x 22 x ,328 5,145 3,963 3,289 2,684 2,684 2, x 22 x ,760 8,509 6,835 5,932 4,651 4,651 3, x 24 x ,464 9,727 7,874 6,517 5,595 5,595 4, x 30 x ,973 12,793 10,502 8,590 7,459 7,459 5, x 30 x ,505 16,490 13,106 10,960 9,034 9,034 7, x 36 x ,217 21,578 17,098 14,480 11,843 11,843 9, x 36 x ,917 27,071 22,003 19,034 15,108 15,108 11, x 40 x ,461 35,237 27,501 23,625 19,069 19,069 15, x 40 x ,206 39,508 31,272 27,115 22,231 22,231 17, x 44 x ,862 53,103 43,166 36,645 29,694 29,694 23,862 All Units in Feet 2 Flange Clearance 2 Flange Clearance Reel Weights subject to change without notice. F66

67 Fiber Optic Cable Packaging and Shipping Information Outside Plant Stranded Loose Tube Armored (O-LA), Loose Tube Non-Armored (O-LN) and Loose Tube Double Jacket, Single Armored (O-L2) High Density Cables Outside Plant Stranded Loose Tube Armored (O-LA/20T) and Loose Tube Non-Armored (O-LN/20T) Cables Armored (O-LA/20T) Non-Armored (O-LN/20T) Flange x Drum x Reel Traverse Weight (lbs) 6@1 8@1 10@1 12@1 6@1 8@1 10@1 12@1 35 x 16.5 x ,698 3,666 3,169 2,470 5,935 4,766 3,731 2, x 24 x ,678 6,023 5,178 4,313 9,786 7,901 6,609 5, x 22 x ,032 7,911 6,978 5,403 13,244 10,939 8,725 6, x 22 x ,664 13,878 11,540 9,487 21,938 17,820 14,151 11, x 24 x ,397 15,677 13,568 10,599 24,908 20,659 16,834 12, x 30 x ,033 21,056 17,818 14,131 33,282 27,612 22,501 16, x 30 x ,770 26,054 21,785 17,697 42,214 34,527 27,656 21, x 36 x ,244 34,537 28,837 23,428 55,904 45,920 36,497 28, x 36 x ,160 42,879 36,490 29,155 59,962 57,194 46,540 36, x 40 x ,962 54,346 46,879 37,670 N/A 59,945 59,333 46, x 40 x N/A 59,945 53,479 43,599 N/A N/A 59,920 52, x 44 x N/A N/A 59,920 58,733 N/A N/A N/A 59,885 All Units in Feet 2 Flange Clearance Armored (O-LA) Non-Armored (O-LN) Double Jacket, Single Armored (O-L2) Flange x Drum x Reel F F F F F Traverse Weight (lbs) 12@6@1 15@9@1 12@6@1 15@9@1 12@6@1 35 x 16.5 x N/A N/A N/A N/A N/A 42 x 24 x ,713 1,327 2,099 1,612 1, x 22 x ,270 1,713 2,709 2,104 1, x 22 x ,019 2,884 4,585 3,387 2, x 24 x ,456 3,341 5,059 3,757 3, x 30 x ,855 4,469 6,781 4,998 4, x 30 x ,472 5,902 9,145 6,483 5, x 36 x ,670 7,327 11,427 8,484 7, x 36 x ,648 9,224 13,778 10,545 9, x 40 x ,844 11,853 17,518 13,389 12, x 40 x ,740 13,489 20,545 15,143 13, x 44 x 46 1,020 24,298 18,714 27,682 20,696 19,074 All Units in Feet 2 Flange Clearance F67 Outside Plant Stranded Loose Tube Armored (Z-LA/20G) and Loose Tube Non-Armored (Z-LN/20G) Cables Armored (Z-LA/20G) Non-Armored (Z-LN/20G) Flange x Drum x Reel Traverse Weight (lbs) 6@1 8@1 10@1 12@1 6@1 8@1 10@1 12@1 35 x 16.5 x ,383 2,838 2,469 2,066 4,276 3,753 2,901 2, x 24 x ,923 4,993 4,312 3,601 7,572 6,010 5,076 4, x 22 x ,813 6,256 5,403 4,536 9,784 8,023 6,871 5, x 22 x ,784 10,612 9,485 7,727 16,317 13,832 11,578 9, x 24 x ,747 12,545 10,596 8,878 18,383 15,893 12,668 10, x 30 x ,573 16,550 14,128 11,737 24,408 20,994 16,975 14, x 30 x ,770 20,387 17,693 14,988 31,366 26,371 21,859 17, x 36 x ,930 27,120 23,423 19,773 40,990 34,892 28,503 23, x 36 x ,545 34,575 29,148 23,932 51,613 44,772 36,083 29, x 40 x ,982 44,042 37,662 31,000 59,962 56,574 46,421 37, x 40 x ,962 50,423 43,589 34,989 N/A 59,945 52,968 43, x 44 x N/A 59,945 58,719 48,345 N/A N/A 59,920 58,775 All Units in Feet 2 Flange Clearance Reel Weights subject to change without notice.

68 Fiber Optic Cable Packaging and Shipping Information Outside Plant Figure-8 Armored (M-LA) and Non-Armored (M-LN) Cables Armored (M LA) Non-Armored (M LN) Flange x Drum x Reel 5@1 6@1 12@1 12@6 15@9 5@1 6@1 12@1 12@6 15@9 Traverse Weight (lbs) x 16.5 x ,671 1, N/A 1,955 1, N/A 42 x 24 x ,807 2,498 1,359 1,359 1,082 3,358 3,036 1,605 1,605 1, x 22 x ,726 3,380 1,983 1,983 1,449 4,486 3,994 2,032 2,032 1, x 22 x ,218 5,801 2,961 2,961 2,578 7,546 6,733 3,431 3,431 2, x 24 x ,256 6,443 3,594 3,594 2,887 8,653 7,557 3,965 3,965 3, x 30 x ,604 8,569 4,751 4,751 3,862 11,364 10,302 5,417 5,417 4, x 30 x ,283 11,179 6,306 6,306 4,717 14,727 13,068 6,820 6,820 5, x 36 x ,062 14,678 8,271 8,271 6,309 19,587 17,017 8,905 8,905 6, x 36 x ,201 18,030 9,887 9,887 7,752 24,056 21,264 11,129 11,129 8, x 40 x ,345 23,153 13,036 13,036 9,878 30,211 26,957 14,509 14,509 11, x 40 x ,968 26,599 14,411 14,411 11,745 34,498 30,567 15,929 15,929 12, x 44 x 46 1,125 34,498 34,498 20,364 20,364 16,271 N/A 34,498 22,219 22,219 17,227 All Units in Feet 2 Flange Clearance Outside Plant Figure-8 Armored (M-LA/25D) and Non-Armored (M-LN/25D) Cables Armored (M LA/25D) Non-Armored (M LN/25D) Flange x Drum x Reel 5@1 1@1 5@1 5@1 5@1 5@1 Traverse Weight (lbs) x 16.5 x ,266 2,069 1,970 2,773 2,551 2, x 24 x ,719 3,359 3,239 4,633 4,088 3, x 22 x ,363 4,799 4,516 6,411 5,785 5, x 22 x ,645 7,821 7,410 10,421 9,494 8, x 24 x ,935 8,861 8,324 12,342 11,108 10, x 30 x ,124 11,874 11,249 16,146 14,711 13, x 30 x ,245 15,563 14,722 20,543 18,208 17, x 36 x ,352 20,450 19,023 26,934 24,294 22, x 36 x ,601 25,252 23,490 33,549 30,000 28, x 40 x ,498 30,000 30,215 34,498 N/A 34, x 40 x N/A N/A 34,063 N/A N/A N/A 96 x 44 x 46 1,125 N/A N/A 34,498 N/A N/A N/A All Units in Feet 2 Flange Clearance Outside Plant ADSS Loose Tube (S-LN) Cables Flange x Drum x Reel 2-60F Traverse Weight (lbs) 5@1 35 x 16.5 x , x 24 x , x 22 x , x 22 x , x 24 x , x 30 x , x 30 x , x 36 x , x 36 x , x 40 x , x 40 x , x 44 x 46 1,125 85,636 All Units in Feet 2 Flange Clearance Reel Weights subject to change without notice. F68

69 Fiber Optic Cable Packaging and Shipping Information Indoor/Outdoor Stranded Loose Tube Non-Armored (R-LN/25D) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F F F F F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6 15@ x 16.5 x ,808 3,748 2,831 2,411 1,741 1,691 1, x 24 x ,710 6,123 5,097 3,836 3,099 3,035 2, x 22 x ,822 8,619 6,778 5,227 3,882 3,825 3, x 22 x ,071 14,016 10,761 8,615 6,860 6,125 4, x 24 x ,002 15,865 12,506 9,869 7,904 7,280 5, x 30 x ,699 21,275 16,786 12,960 10,537 9,533 7, x 30 x ,410 27,380 21,621 16,697 12,870 12,025 9, x 36 x ,634 36,191 28,238 21,809 17,155 15,780 12, x 36 x ,440 44,695 34,470 28,502 22,088 20,519 15, x 40 x ,950 57,152 44,507 35,530 27,602 25,786 20, x 40 x N/A 59,942 50,944 41,293 31,394 29,456 22, x 44 x N/A N/A 59,910 55,980 43,333 40,371 31,361 All Units in Feet 2 Flange Clearance Indoor/Outdoor Stranded Loose Tube Plenum Non-Armored (P-LN/25D) Cables and Plenum/Interlocking Armor (P-LZ/25D) Cables Non-Armored (P-LN/25D) Interlocking Armor (P-LZ/25D) Flange x Drum x Reel 5@1 6@1 8@1 10@1 12@1 5@1 6@1 8@1 10@1 12@1 Traverse Weight (lbs) x 16.5 x ,466 5,297 3,821 2,901 2,343 N/A N/A N/A N/A N/A 42 x 24 x ,523 8,699 6,728 5,076 3,753 2,701 2,701 2,080 2,034 N/A 42 x 22 x ,224 11,860 8,850 6,871 5,249 3,832 3,832 N/A N/A N/A 48 x 22 x ,610 19,205 14,120 11,578 8,662 6,140 6,140 N/A N/A N/A 54 x 24 x ,795 22,219 16,794 12,668 9,714 7,118 7,118 5,581 4,936 N/A 60 x 30 x ,486 29,539 22,455 16,975 13,023 9,555 9,555 7,442 6,637 5, x 30 x ,683 37,957 28,009 21,859 16,468 10,000 10,000 9,012 8,128 6, x 36 x ,412 50,160 36,895 28,503 21,553 N/A N/A 10,000 10,000 8, x 36 x ,950 59,942 47,033 36,083 27,035 N/A N/A N/A N/A 10, x 40 x N/A N/A 59,199 46,421 35,191 N/A N/A N/A N/A N/A 88 x 40 x N/A N/A 59,910 52,968 39,453 N/A N/A N/A N/A N/A 96 x 44 x 46 1,125 N/A N/a N/A 59,872 46,351 N/A N/A N/A N/A N/A All Units in Feet 2 Flange Clearance Indoor/Outdoor and Outside Plant Central Tube Non-Armored (R-CN, O-CN) Cables Flange x Drum x Reel RCN CN CN CN Traverse Weight (lbs) x 16.5 x ,288 5,288 3,668 2, x 24 x ,687 8,687 6,026 4, x 22 x ,006 12,006 7,917 6, x 22 x ,168 19,168 12,922 9, x 24 x ,173 22,173 15,691 11, x 30 x ,487 29,487 20,757 15, x 30 x ,371 38,371 26,076 19, x 36 x ,648 48,648 34,563 25, x 36 x N/A N/A 42,915 32, x 40 x N/A N/A 48,593 33,252 All Units in Feet 2 Flange Clearance F69 Reel Weights subject to change without notice.

70 Fiber Optic Cable Packaging and Shipping Information Outside Plant Central Tube Armored (O-CA) Cables Flange x Drum x Reel CA CA CA Traverse Weight (lbs) x 16.5 x ,278 3,254 2, x 24 x ,574 5,169 3, x 22 x ,786 6,964 5, x 22 x ,322 11,700 8, x 24 x ,389 13,532 9, x 30 x ,414 18,068 13, x 30 x ,376 23,067 17, x 36 x ,002 30,430 22, x 36 x ,545 38,278 28, x 40 x N/A 46,761 33, x 40 x N/A 51,545 N/A All Units in Feet 2 Flange Clearance Outside Plant Flat Drop (O-DF, O-DF/HY) Cables Flange x Drum x Reel ODF ODF/HY Traverse Weight (lbs) x 6.75 x ,000 11, x 16.5 x ,350 19, x 24 x ,926 25, x 22 x ,728 43, x 22 x ,685 48,685 All Units in Feet 2 Flange Clearance LZSH Indoor/Outdoor (Z-DN) Cables Flange x Drum x Reel ZDN ZDN/20T Traverse Weight (lbs) x 16.5 x ,706 14, x 24 x ,980 24, x 22 x ,195 32, x 22 x ,321 48, x 24 x ,726 N/A 60 x 30 x ,439 N/A 66 x 30 x ,671 N/A All Units in Feet 2 Flange Clearance Outside Plant Drop (O-DA, O-DN, M-MN and M-DN) Cables Flange x Drum x Reel DA DN MMN MDN/109 MDN Traverse Weight (lbs) x 6.75 x N/A N/A N/A N/A N/A 35 x 16.5 x ,498 7,087 15,530 9,657 6, x 24 x ,146 11,861 26,042 16,103 11, x 22 x ,697 15,751 34,948 21,560 14, x 22 x ,251 26,446 41,001 34,498 25, x 24 x ,099 30,945 N/A N/A 28, x 30 x ,200 40,792 N/A N/A 38, x 30 x N/A 48,684 N/A N/A 48,674 All Units in Feet 2 Flange Clearance Hybrid Loose Tube Non-Armored/Coax (O-DN-HY, M-DN-HY) Cables Flange x Drum x Reel Fiber + Coax Hybrid Self Supporting Fiber + Coax Hybrid Traverse Weight (lbs) DN (1-12F) DN (1-12F) 35 x 16.5 x ,998 3, x 24 x ,476 6, x 22 x ,362 8, x 22 x ,262 14, x 24 x ,714 17, x 30 x ,842 22, x 30 x ,946 29, x 36 x ,198 37, x 36 x N/A 44,198 All Units in Feet 2 Flange Clearance Reel Weights subject to change without notice. F70

71 Fiber Optic Cable Packaging and Shipping Information Low-Smoke Zero-Halogen (LSZH) Distribution (Z-DS) Cables Fiber Construction 18x12x12 22x12x12 30x12x12 35x16.5x18 35x16.5x18 42x24x25 42x22x x22x x24x28 60x30x32 66x30x32 72x36x36 78x36x36 Type FT FT FT FT FT FT FT FT FT FT FT FT FT 2 SU 4,090 8,991 22,563 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A 4 SU 2,419 5,278 12,881 24,443 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 6 SU 1,976 4,287 10,420 19,855 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 8 SU 1,583 3,418 8,294 15,862 N/A 27,646 28,000 N/A N/A N/A N/A N/A N/A 12 SU 1,228 2,626 6,326 12,375 N/A 21,514 28,000 N/A N/A N/A N/A N/A N/A 18 SU N/A N/A N/A 10,069 N/A 17,289 23,123 28,000 N/A N/A N/A N/A N/A 24 SU N/A N/A N/A 8,393 N/A 14,595 18,966 28,000 N/A N/A N/A N/A N/A 18 MU N/A N/A N/A N/A 2,115 3,859 5,266 8,695 9,540 12,822 16,857 21,628 27, MU N/A N/A N/A N/A 1,737 3,271 4,060 6,990 7,885 10,516 13,410 17,120 22, MU N/A N/A N/A N/A 1,692 3,125 3,919 6,262 7,282 9,536 12,302 15,784 20, MU N/A N/A N/A N/A 1,365 2,220 3,197 4,750 5,732 7,619 10,116 12,865 15, MU N/A N/A N/A N/A N/A 2,043 2,655 4,085 4,547 5,963 8,176 10,536 12, MU N/A N/A N/A N/A N/A 1,669 2,162 3,466 3,864 5,122 6,639 8,431 11,188 Reel Weights subject to change without notice. Riser-Rated Distribution (R-DS) Cables Fiber Construction 18x12x12 22x12x12 30x12x12 35x16.5x18 35x16.5x18 42x24x25 42x22x x22x x24x28 60x30x32 66x30x32 72x36x36 78x36x36 Type FT FT FT FT FT FT FT FT FT FT FT FT FT 2 SU 3,553 8,168 20,028 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A 4 SU 2,522 5,802 14,170 26,713 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 6 SU 2,419 5,278 12,881 24,443 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 8 SU 1,976 4,287 10,420 19,855 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 12 SU 1,640 3,525 8,866 16,947 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 18 SU N/A N/A N/A 10,820 N/A 18,657 24,907 28,000 N/A N/A N/A N/A N/A 24 SU N/A N/A N/A 9,097 N/A 15,669 20,392 28,000 N/A N/A N/A N/A N/A 18 MU N/A N/A N/A N/A 3,673 6,273 8,058 13,136 15,714 20,784 26,930 28,000 N/A 24 MU N/A N/A N/A N/A 2,529 4,600 6,211 9,912 11,586 15,357 19,768 25,111 28, MU N/A N/A N/A N/A 2,475 4,531 5,522 9,036 10,625 14,161 18,409 23,479 28, MU N/A N/A N/A N/A 2,061 3,790 4,728 7,861 8,854 11,710 15,571 20,078 25, MU N/A N/A N/A N/A 1,699 2,785 3,840 6,154 7,135 9,576 12,361 15,541 19, MU N/A N/A N/A N/A 1,360 2,215 3,186 4,849 5,707 7,591 10,072 12,815 16, MU N/A N/A N/A N/A N/A 1,661 2,150 3,443 3,968 5,245 7,340 9,278 11, MU N/A N/A N/A N/A N/A 1,327 1, ,341 4,469 5,902 7,327 9,224 Plenum-Rated Distribution (P-DS) Cables Fiber Construction 18x12x12 22x12x12 30x12x12 35x16.5x18 35x16.5x25 42x24x25 42x22x x22x x24x28 60x30x32 66x30x32 72x36x36 78x36x36 Type FT FT FT FT FT FT FT FT FT FT FT FT FT 2 SU 4,090 8,991 22,563 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A 4 SU 3,050 6,998 17,584 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A 6 SU 2,522 5,802 14,170 26,713 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 8 SU 2,419 5,278 12,881 24,443 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 12 SU 1,696 3,899 9,444 18,048 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 18 SU N/A N/A N/A 10,069 N/A 17,289 23,123 28,000 N/A N/A N/A N/A N/A 24 SU N/A N/A N/A 9,097 N/A 15,669 20,392 28,000 N/A N/A N/A N/A N/A 18 MU N/A N/A N/A N/A 4,679 8,067 10,988 17,918 19,605 26,276 28,000 N/A N/A 24 MU N/A N/A N/A N/A 3,302 6,181 7,968 13,027 14,803 19,637 25,652 28,000 N/A 36 MU N/A N/A N/A N/A 2,845 4,772 6,385 10,820 12,337 16,589 21,158 26,779 28, MU N/A N/A N/A N/A 2,408 4,023 5,437 8,924 10,466 13,975 18,181 23,227 28, MU N/A N/A N/A N/A 1,745 3,193 3,982 6,878 7,926 10,562 13,478 16,872 20, MU N/A N/A N/A N/A 1,461 2,657 3,313 5,488 6,408 8,461 11,067 14,307 17, MU N/A N/A N/A N/A N/A 1,717 2,208 3,921 4,328 5,874 7,500 9,459 11, MU N/A N/A N/A N/A N/A 1,612 2,104 3,387 3,757 4,998 6,483 8,484 10,545 F71 Reel Weights subject to change without notice.

72 Fiber Optic Cable Packaging and Shipping Information Riser, Plenum and LSZH* Simplex (SP) Cables Fiber Size 18x12x12 22x12x12 30x12x12 FT FT FT ,602 28,000 N/A ,364 28,000 N/A ,363 20,848 28, ,897 15,824 28,000 * LSZH is only for the 2.5 and 2.9 cables. Riser, Plenum and LSZH* Zipcord (ZC) Cables Fiber Size 24 x 12 x x 16.5 x 18 FT FT ,000 N/A ,000 N/A ,983 28, ,965 28,000 * LSZH is only for the 2.5 and 2.9 cables. Riser, Plenum and LSZH* Interconnect (IC) Cables Fiber Size 18x12x12 22x12x12 30x12x12 FT FT FT ,897 15,824 28,000 All reels calculated using 2 flange clearance Reel Weights subject to change without notice. F72

73 Fiber Optic Cable Packaging and Shipping Information International Packaging - Weights and Dimensions Reel Dimensions Reels per Layer Layers Cube Size (in.) (l x w x h) Lagging Weight (lbs.) Reel Weight (lbs.) Pallet Weight (lbs.) Total Weight (lbs.) 18 x 12 x x 44 x19 N/A x 12 x x 44 x 32 N/A x 12 x x 44 x 45 N/A x 12 x x 36 x 19 N/A x 12 x x36 x 32 N/A x 12 x x 36 x 45 N/A x 12 x x 44 x N/A x 12 x x 44 x 32.5 N/A x 12 x x 44 x N/A x 12 x X 24 X 30 N/A x 12 x x 42 x N/A x 16.5 x N/A 39 X 25 X x 22 x N/A 44 X 40 X x 24 x 24 1 N/A 44 X 33 X x 22 x N/A 51 x 42 x x 24 x 28 1 N/A 57 x 42 x x 30 x 32 1 N/A 63 X 45 X x 30 x 32 1 N/A 69 X 45 X x 36 x 36 1 N/A 75 X 48 X x 36 x 36 1 N/A 81 x 48 x x 40 x 40 1 N/A 85 x 52 x x40 x 40 1 N/A 91 x 52 x x 44 x 40 1 N/A not palletized NOTE: Units per container can be limited due to product weight F73 Reel Weights subject to change without notice.

Fiber Optic Cable. www.ptsupply.com [email protected] 800-238-7514

Fiber Optic Cable. www.ptsupply.com marketing@ptsupply.com 800-238-7514 Fiber Optic Cable Optical fibers from a choice of major cable manufacturers are available in several grades to manage the bandwidth requirements of today's voice, data and video networks. Single Mode Enhanced

More information

Fiber Optic Cordage. Interconnect A Furukawa Company. Product Description. Why OFS Interconnect Cordage?

Fiber Optic Cordage. Interconnect A Furukawa Company. Product Description. Why OFS Interconnect Cordage? Fiber Optic Cordage Interconnect A Furukawa Company Durable, Flexible Cordage Surpasses Industry Strength Standards for Interconnect Cables Product Description OFS Fiber Optic Interconnect Cordage offers

More information

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS. CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS September 2006 Revision 7 Corning Cable Systems reserves the right to update

More information

Industry solutions: Broad cast

Industry solutions: Broad cast Industry solutions: Broad cast BC 2 industry solutions: Broadcast Optical Cable Corporation s broad range of Fiber Optic Broadcast Cables are specifically designed for real-time transmission of high definition

More information

Fiber Optic Specifications

Fiber Optic Specifications Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will

More information

Fibre Optic Indoor/Outdoor Cable

Fibre Optic Indoor/Outdoor Cable Volition TM Fibre Optic Indoor/Outdoor Cable Tough enough to take it. Easy to handle. The Volition Network Solutions Indoor/Outdoor Fibre Optic Cable from 3M includes horizontal and backbone cable with

More information

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Discontinued. Volition. Fiber Optic Cable. 3Innovation Volition Fiber Optic Cable Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm and 50/125 µm multimode fiber, and 9/125

More information

OFS AllWave Zero Water Peak (ZWP) single-mode

OFS AllWave Zero Water Peak (ZWP) single-mode The New Standard for Single-Mode Fiber Product Description OFS AllWave Zero Water Peak (ZWP) single-mode optical fiber is the industry s first full-spectrum fiber designed for optical transmission systems

More information

Broadband Applications & Construction Manual. Fiber Optic Cable Products

Broadband Applications & Construction Manual. Fiber Optic Cable Products Broadband Applications & Construction Manual Fiber Optic Cable Products Table of Contents 0.1 Fiber Optic Cable Applications and Construction Manual Table of Contents Section 1... Introduction Section

More information

SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING

SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete

More information

Fibre Optic Cable. Catalogue. www.fibrefab.com

Fibre Optic Cable. Catalogue. www.fibrefab.com Fibre Optic Cable Catalogue www.fibrefab.com About The FibreFab Group FibreFab Established in 1992, FibreFab is a leading provider of fibre optic connectivity products used in data communications and Telecommunication

More information

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Optical Fibers Fiber Optic Cables Indoor/Outdoor presents Optical Fibers Fiber Optic Cables Indoor/Outdoor Content Optical fiber function, types optical effects applications production of optical fibre Cable - general types Indoor Indoor / outdoor Outdoor

More information

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification. 10 Cables The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases

More information

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information. GOWN Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOWN102

More information

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned) 1 1 9.41 115 0 Patch cables are used 143 12 Fibre MTP Jumper, MTP (non-pinned) to Patch cables are used for non -permanent connections between patch panels, transmission equipment, etc. Pre -assembled

More information

ALL-DIELECTRIC LOOSE TUBE FIBER OPTIC CABLE

ALL-DIELECTRIC LOOSE TUBE FIBER OPTIC CABLE ALL-DIELECTRIC LOOSE TUBE FIBER OPTIC CABLE PRODUCT SPECIFICATIONS City of Denver March 2006 Notice: Every effort has been made to ensure that the information contained in this document is complete and

More information

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

SECTION 680 FIBER OPTIC CABLE DESCRIPTION 680 SECTION 680 FIBER OPTIC CABLE DESCRIPTION 680.01.01 GENERAL A. The work under this section shall consist of furnishing, installing, and testing all underground and outdoor fiber optic cables. B. All

More information

home site map help ECMS Project: 70197 Standard / Federal Oversight Advertised

home site map help ECMS Project: 70197 Standard / Federal Oversight Advertised Page 1 of 6 S PECIAL PROVISION home site map help ECMS BP ADMIN Project: 70197 Standard / Federal Oversight Advertised Short Description: US 422 Schuylkill River Bridge - D/B: Retaining Wall; ITS Devices;

More information

ESPECIFICACIÓN DE PRODUCTO

ESPECIFICACIÓN DE PRODUCTO ESPECIFICACIÓN DE PRODUCTO CABLE DE FIBRA ÓPTICA MONO MODO All Dielectric Self Supporting Single Mode Optical Fiber Cable Product Name: All Dielectric Self Supporting Single Mode Optical Fiber Cable Product

More information

Polymer Coated Fiber Cable (PCF)

Polymer Coated Fiber Cable (PCF) Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability

More information

288 Fiber Ultra-High Fiber Density Micro-Duct Cable with Extreme Operating Performance

288 Fiber Ultra-High Fiber Density Micro-Duct Cable with Extreme Operating Performance 288 Fiber Ultra-High Fiber Density Micro-Duct Cable with Extreme Operating Performance Justin Quinn AFL Duncan, SC +1-864-486-7073 [email protected] Olaf Storaasli Dura-Line Knoxville, TN +1-630-402-0015

More information

ENTERPRISE FIBER OPTIC CABLE. Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore

ENTERPRISE FIBER OPTIC CABLE. Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore ENTERPRISE FIBER OPTIC CABLE Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore Founded in 1984, AFL is a global leader providing fiber optic products, equipment, and engineering services to the

More information

FIBER OPTIC Cables. Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables

FIBER OPTIC Cables. Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables FIBER OPTIC Cables Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables TMC Co., Ltd has been pursuing innovation in technology and products for Ship and Information & Telecommunication industry.

More information

Fiber Optics in Harsh Environment Applications

Fiber Optics in Harsh Environment Applications Fiber Optics in Harsh Environment Applications Table of Contents Industrial Testing Comparisons 2 Fiber Optics in Harsh Environment Applications 3 Oil & Gas Products 4 Mining Products 6 Manufacturing 8

More information

GOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

GOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits GOSB Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOSB102 GOSB104 GOSB106

More information

OPTICAL FIBER CABLES

OPTICAL FIBER CABLES OPTICAL FIBER CABLES CONTENTS INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS GENERALITIES :. Advantage. General Description.. Construction.. Principle TYPICAL SPECIFICATIONS OF OPTICAL

More information

The following terms are defined within the context of the fiber optic industry

The following terms are defined within the context of the fiber optic industry The following terms are defined within the context of the fiber optic industry Adapter A mechanical media termination device designed to align and join fiber optic connectors. Often referred to as coupling,

More information

SINGLE MODE OPTICAL FIBER FTTH CABLE

SINGLE MODE OPTICAL FIBER FTTH CABLE Specification No: RE650/660-- FTTH CABLE DEC 2001 SINGLE MODE OPTICAL FIBER FTTH CABLE Renka Corporation Two Corporation Way Peabody, MA 01960 USA 1.0 INTRODUCTION TO RENKA SINGLE MODE OPTICAL FIBER FTTH

More information

200-Micron Single-Mode Fiber Enables New Cable Designs Copyright 2014 OFS FITEL, LLC

200-Micron Single-Mode Fiber Enables New Cable Designs Copyright 2014 OFS FITEL, LLC 200-Micron Single-Mode Fiber Enables New Cable Designs Copyright 2014 OFS FITEL, LLC Since single-mode optical fiber was first introduced in the early 1980 s, little has changed in its basic geometric

More information

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER 1. Applications - Be suitable for the cable of communication,communication device pigtail and the movable connection wire jumper wire - Short and medium distance,

More information

CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES

CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES AND ADVANTAGES OF OPTICAL FIBER CABLES ADVANTAGES Low attenuation. Long repeater spacings or repeaterless networks. Wide bandwidth. Large transmission capacity with simultaneous voice, data and video transmission

More information

GOSN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

GOSN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits GOSN Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOSN102 GOSN104 GOSN106

More information

Plug & Play Universal Systems

Plug & Play Universal Systems Plug & Play Universal Systems A LANscape Pretium Plug & Play Universal Systems for Data Centers and Storage Area Networks (SANs) Corning Plug & Play universal systems create a fiber optic tip-to-tip solution

More information

P URCHASING D IVISION

P URCHASING D IVISION C I T Y O F E N G L E W O O D P URCHASING D IVISION Date: March 7, 2006 Request # RFQ-06-117 GENERAL CONDITIONS SINGLE-MODE (SM) AND MULTI-MODE (MM) FIBER OPTIC CABLE The City of Englewood will receive

More information

OPTICAL FIBRE CABLE APPLICATIONS GUIDELINES

OPTICAL FIBRE CABLE APPLICATIONS GUIDELINES OPTICAL FIBRE CABLE APPLICATIONS GUIDELINES Introduction: The use and demand for optical fibre has grown up tremendously and the applications of optical-fibre are numerous. Telecommunication applications

More information

7.4 3M No Polish Connector

7.4 3M No Polish Connector Cap Fibre Splice Element Description 3M No Polish Connector (NPC) enables fast, on-site installation of 250μm and 900μm connections utilizing a one piece, pre-assembled design. The SC compatible connector

More information

KGP Logistics Outside Plant Catalog

KGP Logistics Outside Plant Catalog KGP Logistics Outside Plant Catalog Exchange Cable Fiber Optic Cable Wire and Cable Conduit and Innerduct Vaults and Pads Splice Connectors Grounding and Bonding Closures Terminal Blocks Pedestals Cabinets

More information

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks OPTICAL FIBRE CABLES for very-high bit transmission and FTTx networks OPTICAL FIBRE CABLES SILEC CABLE REFERENCES AND KNOW-HOW Since 1983, Silec Cable has successfully supplied the major telecom operators,

More information

The Conversion Technology Experts. Fiber Optics Basics

The Conversion Technology Experts. Fiber Optics Basics The Conversion Technology Experts Fiber Optics Basics Introduction Fiber optic technology is simply the use of light to transmit data. The general use of fiber optics did not begin until the 1970s. Robert

More information

fiberopt Whirlwind Fiber Optic Solutions product guide 1-800- 733-9473 99 Ling Rd. Rochester, NY 14612 whirlwindusa. com

fiberopt Whirlwind Fiber Optic Solutions product guide 1-800- 733-9473 99 Ling Rd. Rochester, NY 14612 whirlwindusa. com fiberopt Whirlwind Fiber Optic Solutions product guide 1-800- 733-9473 99 Ling Rd. Rochester, NY 14612 whirlwindusa. com OpticalCON DUO, QUAD and ADAPTER CABLES 1 2 OC-4-OQ-OQ-0-050 OC-2-M50-OD-SC-0-005

More information

Specification SFTP CAT6 Network Cable 23AWG CU

Specification SFTP CAT6 Network Cable 23AWG CU Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)

More information

Fibre optic cables MDIC LSZH

Fibre optic cables MDIC LSZH MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy

More information

P URCHASING D IVISION

P URCHASING D IVISION C I T Y O F E N G L E W O O D P URCHASING D IVISION Request # RFQ-09-106 Date: April 3, 2009 Specifications and General Conditions Single Mode Fiber Optic Cables The City of Englewood will receive online

More information

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION Fiber Single Mode Optical Fibre 144 Nos. Sterlite Fiber ITU.T - G.652 D Maximum Cabled Fibre Attenuation db/km 1310nm : 0.36 & 1550nm : 0.23 Loose Tube Filling Jelly Fiber/Tube 24 Nos. Thixotropic jelly

More information

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment INFOCOMMUNICATIONS Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment Fumiaki SATO*, Masakazu TAKAMI, Yoshiaki NAGAO, Kentaro TAKEDA and Hiroshi

More information

Fiber Optic Cable Products. Leading Solution

Fiber Optic Cable Products. Leading Solution Fiber Optic Cable Products Leading Solution Leading Solution LG Cable, LG Industrial Systems and LGNikko Copper, Gaon Cable, E1 and Yesco are starting with a new name, Leading Solution, LS. New Dream,

More information

SINGLE MODE OPTICAL FIBER CABLE

SINGLE MODE OPTICAL FIBER CABLE Specification NO: RENKA/OFC/SM-DI/AR DEC 2000 SINGLE MODE OPTICAL FIBER CABLE Renka Corporation Two Corporation Way Peabody, MA 01960 USA 1.0 INTRODUCTION TO RENKA SINGLE MODE OPTICAL FIBER CABLE This

More information

INTERNATIONAL TELECOMMUNICATION UNION #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43

INTERNATIONAL TELECOMMUNICATION UNION #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!,%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43 INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43 /04)#!, &)"2% #!",%3 &/2

More information

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future CORDS & CABLE ASSEMBLIES Standard Simplex/Duplex Patch Cords Overview: FOCONEC supplies full series of standard simplex, duplex patch cords or pigtails, designed for interconnection or cross connection

More information

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other

More information

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007 804.01 Description 804.02 General 804.03 Materials 804.04 Fan-Out Kit 804.05 Drop Cable 804.06 Fiber Optic Patch Cord 804.07 Termination Panel 804.08 Fusion Splice 804.09 Fiber Optic Connector 804.10 Splice

More information

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,

More information

Guidelines for Installation of Fiber Optic Cables

Guidelines for Installation of Fiber Optic Cables Guidelines for Installation of Fiber Optic Cables Scope The intent of the document is to provide installation guidelines for NextGen fiber optic cables to assure proper optical and mechanical performance

More information

SECTION 16121 FIBER OPTIC CABLE AND ACCESSORIES

SECTION 16121 FIBER OPTIC CABLE AND ACCESSORIES SECTION 16121 FIBER OPTIC CABLE AND ACCESSORIES PART 1 GENERAL 1.1 Summary A. This section includes the components and fiber optic cable necessary to provide a network Connection as indicated. The components

More information

Specifying an IT Cabling System

Specifying an IT Cabling System Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your

More information

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/96) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT /PTICAL

More information

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration Bill Charuk, SR Product Manager, Data Center Solutions Introduction With the advent of data centers in communication infrastructure, various

More information

Attenuation: Bending Loss

Attenuation: Bending Loss Consequences of Stress Optical Communications Systems Stress Bending Loss and Reliability in Optical Fibres Increased Loss in the Fibre Increased Probability of Failure Bending Loss in Fibres At a bend

More information

Procedure for Cutting and Respooling Fiber Optic Cable

Procedure for Cutting and Respooling Fiber Optic Cable Table of Contents 1. GENERAL 1.1 Improper use of a respooler (Figure 1) can cause damage to a cable jacket or result in wavy fiber in tight buffered cables due to cable crossovers or excessive tensile

More information

Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5

Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 BryComm, LLC -SDD-1901 Cabling Services (per pull) - Labor Only STANDARD TIME The price per cable pull represents all labor to include fishing walls, running cable through modular furniture, terminating,

More information

Tray-Rated Fiber Cables for Industrial Applications

Tray-Rated Fiber Cables for Industrial Applications LSZH Industrial Cables are all cable trayrated per IEEE-383 and ANSI/ICEA S-104-696, UL1277, UL13, UL444 and CSA C22.2 No. 230 and No. 232, a preferred tray-rating standard for industrial applications.

More information

Fiber Selection and Standards Guide for Premises Networks

Fiber Selection and Standards Guide for Premises Networks Fiber Selection and Standards Guide for Premises Networks WP1160 Issued: November 2013 Supersedes: November 2012 Authors: Carl Roberts and Dr. Russell Ellis Introduction There are several main types of

More information

Fiber-to-the-Home/FTTH

Fiber-to-the-Home/FTTH Hands-On Design, Installation, Maintenance & Troubleshooting Active and Passive Optical Networks Course Description This Hands-On 2-day course is designed to provide technicians with Hands-On practical

More information

ITU-T L.87. Optical fibre cables for drop applications

ITU-T L.87. Optical fibre cables for drop applications International Telecommunication Union ITU-T L.87 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (07/2010) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

More information

Broadcast and Commercial AV Cabling MASTER CATALOG

Broadcast and Commercial AV Cabling MASTER CATALOG Broadcast and Commercial AV Cabling MASTER CATALOG Clark Wire & Cable 408 Washington Blvd. Mundelein, IL 60060 800-222-5348 toll free 847-949-9944 local 847-949-9595 fax www.clarkwire.com Specifications

More information

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects. FC black process black LockPORT Security Patch Cables CAT5e, CAT6 and Fibre 5th black Secure network ports from unauthorized access and accidental disconnects. BLACK BOX» LockPORT cables stay locked in

More information

3200 West 22nd Street Erie, PA 16506 ph 814.835.2900 fax 814.835.2904 www.premierconduit.com

3200 West 22nd Street Erie, PA 16506 ph 814.835.2900 fax 814.835.2904 www.premierconduit.com 200 West 22nd Street Erie, PA 16506 ph 814.85.2900 fax 814.85.2904 www.premierconduit.com Premier-Plenum Duct Premier Plenum Duct is a flexible, non-metallic, corrugated raceway used for effective interior

More information

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS Features: SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS Low insertion loss < 0.2 db Excellent repeatability FC/PC, SC, ST, LC, MU, E2000 termination available Custom ferrule termination available Designed

More information

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers WP4259 Issued: January 2015 Brillouin Optical Time Domain Reflectometry The Brillouin Optical

More information

QuickSpecs. HPE OfficeConnect 1410 Switch Series. Overview. HPE OfficeConnect 1410 Switch Series. Models. Key features.

QuickSpecs. HPE OfficeConnect 1410 Switch Series. Overview. HPE OfficeConnect 1410 Switch Series. Models. Key features. Overview Models HPE OfficeConnect 1410 8G Switch HPE OfficeConnect 1410 24G R Switch HPE OfficeConnect 1410 8 Switch HPE OfficeConnect 1410 16 Switch HPE OfficeConnect 1410 24 Switch HPE OfficeConnect

More information

P R O D U C T I N F O R M A T I O N

P R O D U C T I N F O R M A T I O N PRODUCT INFORMATION LASER ULTRA-FOX CABLES AND LASER ULTRA-FOX DE CABLES PI 2 PRODUCT INFORMATION Laser Ultra-Fox Cables For the laser-based high-speed networks of today and tomorrow, Optical Cable Corporation

More information

MarineTuff Offshore and Marine Cable Solutions

MarineTuff Offshore and Marine Cable Solutions Offshore and Marine Cable Solutions Belden offers the industry s largest selection of industrial cables for offshore and marine certified applications Whether you are handling oil, natural gas or petrochemicals,

More information

Outside Telephone Cable

Outside Telephone Cable Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of

More information

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.87 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (07/2010) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

More information

Patch Cords for Data Center Applications

Patch Cords for Data Center Applications Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails

More information

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor TABLE OF CONTENTS SECTION I. SUBJECT SCOPE 2 II. APPLICABLE DOCUMENTS 2 III. CONDUCTOR 3 IV. SEPARATOR 3 V. INSULATION 3 A. 3-4 B. Electrical Properties 4 C. Flame Resistance 5 D. Smoke and Halogen Testing

More information

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE

More information

Uniprise Solutions COAX 101. White Paper. www.commscope.com

Uniprise Solutions COAX 101. White Paper. www.commscope.com Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems

More information

Reliable, Consistent, Quality

Reliable, Consistent, Quality Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic

More information

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) Abstract Fiber-to-the-Premises (FTTP) networks increasingly

More information

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations The Fiber Optic Association, Inc. 1119 S. Mission Road #355, Fallbrook, CA 92028 1-760-451-3655 Fax 1-781-207-2421 Email: [email protected] http://www.thefoa.org Technical Bulletin Guidelines For Testing

More information

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1 Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader

More information

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission

More information

SPECIALTY FIBER OPTIC CABLE. Downhole Sensing Subsea

SPECIALTY FIBER OPTIC CABLE. Downhole Sensing Subsea SPECIALTY FIBER OPTIC CABLE Specialty Fiber Optic Cable Customers around the world benefit from using AFL fiber optic cable and components for downhole sensing and subsea umbilicals. With its patented

More information

Fiber Optic Cable Installation

Fiber Optic Cable Installation Fiber Optic Cable Installation Generally speaking, fiber optic cable can be installed using many of the same techniques as conventional copper cables. General Guidelines The following contains information

More information

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables International Telecommunication Union ITU-T G.657 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (11/2009) SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and

More information

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP

More information

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS) DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS) Double Jelly Filled Stainless Steel Tube General Description This document specifies non armour sensing fiber cable with double stainless

More information

Pretium EDGE HD Solutions

Pretium EDGE HD Solutions Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Cable Systems Pretium EDGE HD Solutions create a fiber optic tip-to-tip solution for Data Centers and Storage Area

More information

part number number Description B96551 M96551 Tactical, All Dielectric Cable, Tight Buffer, Oudoor, Multimode OM1, 62.5 µm, 4 fibers B96566 M96566

part number number Description B96551 M96551 Tactical, All Dielectric Cable, Tight Buffer, Oudoor, Multimode OM1, 62.5 µm, 4 fibers B96566 M96566 part B96551 M96551 Tactical, All Dielectric Cable, Tight Buffer, Oudoor, Multimode OM1, 62.5 µm, 4 fibers B96566 M96566 Tactical, All Dielectric Cable, Tight Buffer, Oudoor, Singlemode Enhanced OS2, 2

More information

Types of Optic Cable andApplications

Types of Optic Cable andApplications STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 904 FIBER OPTIC CABLE AND COMPONENTS April 18, 2014 904.01 Fiber Optic Cable. Furnish loose-tube, single-mode, step-index dielectric

More information

Fiber Optic Technology

Fiber Optic Technology Fiber Optic Technology for Audio, Video and Data Systems " EXCEEDING EXPECTATIONS TIONS WITH PERFORMANCE " ... WHAT IS FIBER OPTICS? Transparent glass or plastic fibers which allow light to be guided from

More information

BELFLOW SERIESS FIBER DISTRIBUTION FIBER DISTRIBUTION BELFLOW IS A BOF (BLOWING OF FIBER) SYSTEM DEVELOPED FROM BELCONN. www.belconn.

BELFLOW SERIESS FIBER DISTRIBUTION FIBER DISTRIBUTION BELFLOW IS A BOF (BLOWING OF FIBER) SYSTEM DEVELOPED FROM BELCONN. www.belconn. BELFLOW SERIESS BELFLOW IS A BOF (BLOWING OF FIBER) SYSTEM DEVELOPED FROM BELCONN TO DEAL WITH OPPORTUNITIES OFFERED BY BROADBAND MARKET. BELFLOW INTRODUCES A NEW TECHNOLOGY THAT MEETS THE DEMANDS OF UTILISATION,FLEXIBILITY

More information

108-93018 05 APR 2016 Rev M

108-93018 05 APR 2016 Rev M Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The

More information

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions. www.commscope.

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions. www.commscope. SYSTIMAX Solutions GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions www.commscope.com The SYSTIMAX GigaSPEED X10D Shielded Solution provides unprecedented performance

More information