RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features



Similar documents
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

CADB and CADT-D / DI / DC Series

CE6500 Energy Recovery Ventilator

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

type UTA Technical information manual

york air-conditioning products Residential & VRF News 2015

squrboxbox heat recovery squrboxbox I technical information

Cool Design for Homes and Offices

ECOCIAT. Domestic hot water heat recovery unit

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Product catalog UNT-PRC011-E4

eq Top/TopMaster Air Magic by Fläkt Woods

Operation and Installation Manual. Max Series

RPV - RP - RA air handling units

Condensing unit type EPSILON-ECHOS LE Technical information manual

KONRAD. Hybrid Fancoil Series

Bring the fresh in. Dedicated Outside Air Systems

Installation and maintenance instructions. Danfoss Vent

FULL DC INVERTER SYSTEMS

Split System Cooling Product Data

TWE+TTA TWE+TWA T.R.

Product catalog UNT-PRC017-E4

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Commercial Gas Furnace Upflow

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Under sill units. Type FSL-B-ZAS

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range


HEAVY DUTY STORAGE GAS

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR

Lesson 36 Selection Of Air Conditioning Systems

SWIMMING POOL HEAT PUMP Owners Manual

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Unico Inverter. Unique and efficient.

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

We have been working in an ideal climate for thirty years.

EC medium pressure axial fans. The effi cient system solution.

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Freezers - Ultrafreezers. Platilab & Irilab Series

DUCTED AIR CONDITIONING SOLUTIONS

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

HVAC Processes. Lecture 7

COMMISSIONING OF HVAC SYSTEMS

Chilled Water Precision Air Conditioner For Critical Application

PLUG and PLAY VRV Connection

Zehnder Focus 200. Ventilation device

FAN COIL. Technibel is a trademark of Nibe Energy System France used under license

Adsorption air dryers ADS 1 215

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Split System Heat Pump Product Data

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Innovent LASER Packaged Fresh Air Conditioning Units

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

SECTION MORTUARY REFRIGERATORS

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Cooking at the Speed of light!

The compact unit series

Inverter Air Conditioning for Light Commercial Use

Controls for fan coil units and cassettes

Installation Instructions

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

TFSR & TFSK Roof Fans

FLAT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving ENERGY CLASS B A A B A A UNIT

Installation, operation and maintenance manual TX 35A

Element D Services Heating, Ventilating, and Air Conditioning

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Flexit air handling unit K2 R

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Delivering exceptional performance and Ecovalue. Ecocent

HDA

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Energy Efficiency HOSPITALITY.

UDSA - UDSBD unit heater

Cooling kw Heating kw

FTQ. Daikin Inverter Ducted Heat Pump

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

PFT Two stage axial fan The high pressure fan for modern boiler plants

EcoStar Professional warewashing with integrated effi ciency and hygienic reliability

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Operators manual Basic water heater

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Split System Cooling Product Data

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

CF HORIZONTAL WATER RECESSED DUCTABLE TERMINAL UNIT

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

T5000 T000 LCD Digital Fan Coil Thermostat

Transcription:

RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants, by using an aluminium plated crossfl ow heat exchanger, able to transfer more than 50% of heat which otherwise would be lost with air exhaust. These units may be integrated with traditional heating and cooling systems (such as fan-coils, water heaters, etc.) and can operate both in summer and winter seasons. RKE series consists of 10 models, with airfl ow rate from 200 m³/h to 6800 m³/h; all the units are particularly suitable for false ceiling installation and may be appropriately ducted allowing air supply and air suction directly in the room. RKE units are available in the following base versions: RKE horizontal unit RKE/V vertical unit Mechanical features Fully removable panels (sandwich type). Acoustic and thermal panel insulation (thickness 10 mm for RKE03-06-10 models and 20mm for bigger models). High effi ciency aluminium plated heat recovery - EUROVENT certifi cated - with airfl ows separated by special seals. G4 effi ciency class air fi lters, easily removable everywhere (bottom, side, top) allowing their periodic cleaning; as an option, F6-F7-F8 effi ciency class soft bag fi lters. Fans mounted on a easy removable support. Double inlet centrifugal fans, with multispeed direct driven motor. The unit is complete of electrical terminal box fi tted with relay board, to aid the electrical connections and fan control. Galvanized steel condensate drain tray, with lower drainage. > Internal water heating coil > Electric heater > Water cooling coil external section > Adiabatic cooling/umidifier section > Round adapter for circular duct > 3-damper mixing box > Damper connection lever > F6 compact fi lter > F6 soft bag fi lter > F7 soft bag fi lter > F8 soft bag fi lter > Frequency converter fan-motors > Roof cover > Adjusting damper > Antivibrating fl exible joint > Casing with bird net > Supports legs H 90 (kit 4 p) > Supports legs H 200 (kit 4 p) Controls Accessories SKW SKE SAF HCP BCC MS3 LCS FC6 FT6 FT7 FT8 DDE* TPR SKR GAT CFA PD PDX heat recovery unit RKE * not available on RKE03 and 06 STEEL FRAME AND INSULATED PANEL CEILING FIXING SYSTEM OF THE UNIT ELECTRIC BOARD WITH RELAYS THE BEST POIBILITY OF INSPECTION, MAINTENANCE AND REPLACEMENT OF ALL THE INTERNAL COMPONENTS, ALSO IF THE UNIT IS ALREADY INSTALLED CONDENSATE DRAIN TRAY MOVABLE FOR CLEANING AND MAINTENANCE 3

heat recovery unit RKE RKE Model 03 06 10 14 19 25 30 40 50 60 Airfl ow rate Max 300 500 1000 1400 1900 2500 3200 4000 5000 6000 Med m 3 /h 200 300 900 1250 1570 1830 2500 - - - Min 100 150 800 850 1340 1100 1800 3000 4000 5000 Max 100 100 90 145 120 110 170 170 120 190 External static pressure Med Pa 160 129 70 133 121 112 159 - - - Min 167 127 47 113 119 112 144 147 221 226 Max 51,1 51,1 52,2 62,3 58,4 56,0 58,8 62,1 63,7 64,5 1 m sound pressure level Med db(a) 49,7 47,4 48,8 56,9 53,7 51,0 53,5 - - - Min 44,3 41,0 45,3 45,6 42,1 44,6 51,1 54,9 59,1 62,0 Shaft power W 2x60 2x60 2x147 2x350 2x350 2x350 2x550 2x750 2x1500 2x1500 Maximum current A 1,2 1,4 3,0 5,8 6,2 6,0 11,4 6,2 11,2 11,2 Fan speeds n 3 3 3 3 3 3 3 2 2 2 Poles n 2 2 4 4 4 4 4 4 4 4 Protection degree - minimum - IP 20 Temperature class - minimum - B Electrical power supply V/ph/Hz 230/1/50 400/3/50 Max 52,0 56,1 53,4 52,1 51,8 57,6 56 55,7 54,6 54,5 Recovery efficiency (1) Med % 57,0 62,5 54,8 53,5 54,1 61,5 59,0 - - - Min 66,4 71,1 56,3 58,4 56,1 67,7 63,1 59,2 57,3 56,8 Max 1,4 2,6 4,9 6,7 9,0 13,2 16,4 20,3 24,9 29,9 Saved power (1) Med kw 1,0 1,7 4,5 6,1 7,8 10,3 13,5 - - - Min 0,6 1,0 4,1 4,5 6,9 8,6 10,4 16,2 20,9 25,9 Max 8,0 9,0 8,4 8,0 7,9 9,4 9,0 8,9 8,6 8,6 Supply temperature (1) Med C 9,3 10,6 8,7 8,4 8,5 10,4 9,8 - - - Min 11,6 12,8 9,1 9,6 9,0 11,9 10,8 9,8 9,3 9,2 (1) At the following conditions: room air temperature 20 C db 50% RH; fresh air temperature -5 C. MAX SPEED AIR PERFORMANCES 400 ext. static pressure (Pa) 350 300 250 200 150 100 50 RKE 30 RKE 06 RKE 19 RKE 14 RKE 25 55,8 db(a) 57,3 db(a) RKE 10 RKE 03 51,9 db(a) 62,3 db(a) 58,4 db(a) 52,2 db(a) 51,1 db(a) 56,0 db(a) 56,0 db(a) RKE 40 RKE 50 61,4 db(a) 58,8 db(a) 59,0 db(a) 60,5 db(a) 62,1 db(a) RKE 60 63,7 db(a) 65,5 db(a) 64,5 db(a) 64,9 db(a) 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 airfl ow rate (m 3 /h) 4

RKE Accessories 03 06 10 14 19 25 30 40 50 60 Water heating coil SKW Heating capacity (at max fan speed) (1) kw 11,3 16,3 20,4 29,7 35,1 44,3 46,6 53,8 temperature C 40,5 41,5 39,0 42,2 39,6 39,9 34,9 33,8 Air side pressure drop Pa 66 63 85 61 85 90 95 115 Coil rows n 3 3 3 3 3 3 3 3 Water side pressure drop kpa 13 31 18 20 27 49 22 24 Water fl ow rate m 3 /h 0,99 1,43 1,80 2,61 3,09 3,90 4,10 4,70 Electric heater SKE Heating capacity kw 2 4 4,5 6 9 12 12 12 18 24 Air side T (at max fan speed) C 20 24 13 13 14 14 11 9 11 12 Electrical power supply V/ph/Hz 230/1/50 400/3/50 Air side pressure drop Pa 5 5 6 6 8 6 9 13 11 13 Water cooling coil SAF Total cooling capacity (at max fan speed) kw 2,6 3,8 7,4 9,8 13,1 20,3 24,2 30,7 31,6 37,9 temperature C 15 17 17 18 18 17 17 17 18 18 Air side pressure drop Pa 23 67 74 82 90 66 100 98 66 69 Coil rows n 3 3 3 3 3 3 3 3 3 3 Water side pressure drop kpa 8 15 18 13 14 27 38 51 33 43 High efficiency filter (at max fan speed) F6 Compact filter FC6 pressure drop Pa - - - 40 40 40 40 40 40 40 F6 Bag filter FT6 pressure drop Pa - - - 140 160 160 160 180 175 160 F7 Bag filter FT7 pressure drop Pa - - - 165 185 185 185 215 205 185 F8 Bag filter FT8 pressure drop Pa - - - 207 225 225 225 260 248 225 heat recovery unit RKE Round adapter for circular duct BCC Diameter Ø mm 200 200 315 315 315 355 400 450 600 600 (1) Inlet air temperature 8 C - Water temperature 70 /60 C. (2) Inlet air conditions 29 C db 60% RH - Water temperature 7 /12 C. DIMENSIONS SKR O RxT RxT RxT P Q d SAF RKE MS3 5

heat recovery unit RKE Dimensions 03 06 10 14 19 25 30 40 50 60 A (mm) 990 990 1150 1350 1450 1700 1700 1700 1700 1900 B (mm) 750 750 860 900 900 1230 1230 1230 1350 1450 C (mm) 270 270 385 410 470 490 530 630 705 755 D (mm) - - 230 230 280 305 305 405 480 530 Ø ( ) - - ¾ ¾ ¾ ¾ ¾ ¾ 1 1 E (mm) 195 195 245 241 241 323 308 308 353 (278) 379 (334) F (mm) 170 170 238 224 284 290 331 377 427 (353) 419 (379) G (mm) 197 197 225 241 241 323 323 323 353 379 H (mm) 100 100 218 270 270 270 297 297 297 (339) 350 (403) H1 (mm) 153 153 267 267 327 347 387 487 555 615 L (mm) 162 162 240 240 240 306 339 339 339 (297) 403 (350) L1 (mm) 275 275 330 337 337 502 502 502 555 615 M (mm) -- (119) -- (119) -- (81) -- (81) -- (81) -- (131) -- (101) -- (101) -- (101) -- (101) weight kg 39 41 68 91 99 140 155 179 235 273 O (mm) 375 375 430 450 450 615 615 615 675 725 P (mm) 400 400 400 700 700 700 700 800 850 900 Q (mm) - - 450 480 480 650 650 650 707 757 R (mm) 210 210 310 310 410 410 410 510 610 610 T (mm) 280 280 330 330 330 500 500 500 600 600 d ('') ¾ ¾ ¾ ¾ ¾ 1 1 1 1 ½ 1 ½ Where different, within brackets, dimensions of vertical version A G E H L L1 Filter VERTICAL UNIT H A Possible post-heating F G L1 L C D B E B F H1 HORIZONTAL UNIT ø C ½" M 90 H1 6

OUTSIDE RKE POIBLE INSTALLATIONS (horizontal version) TYPE A TYPE B INSIDE OUTSIDE TYPE C INSIDE OUTSIDE TYPE D INSIDE OUTSIDE INSIDE heat recovery unit RKE RKE/V POIBLE INSTALLATIONS (vertical version) Vertical confi guration (with re-heating system - only type B or C) TYPE A TYPE B TYPE C TYPE D 7

8heat recovery unit RKE SPEED CONTROL Control panel CVU: manual 3 step fan speed regulator (min/med/max). 3 POINT CONTROL CONTROLS It is mainly composed of a control panel and valves that allow a modulating regulation on 3 points and a manual or automatic control of the fan speeds. Control panel PCR: command panel with manual or automatic regulation of the fan speeds by 3 steps, manual or automatic mode summer/winter, room thermostat (remotable by NTC 4,7 sensor, optional), handling of two water coils for heating/cooling or coil (cold or promiscuous) and electric heater. Accessories controlled by PCR V33: 3 way valve with electric servocontrol, power supply 230V NTC4,7: remotable temperature sensor Accessories not controlled TEG: antifreeze thermostat E: on/off damper servocontrol power supply 230 V PSTD: air filter pressure switch MODULATING CONTROL It is composed by an electronic kit, an hydronic kit and a range of accessories used for the control services. The modulating regulation allows to optimize the unit work handling carefully the air fl ow rate and the water fl ow rate to satisfy the request (set point). Electronic Kit RQU: temperature analogical regulator complete by n. 3 NTC sensor and electric board Regulator services Heating/cooling/free-cooling automatic mode (2/4 pipe plant) antifreeze electric heater on/off mode winter heating speed-up heat recovery defrost manual or automatic fan speed selection (by CO 2 or pressure sensor) dirty filter alarm (by PSTD) missing ventilation alarm (by pressure switch) Timer Prearrangement for BMS (via MODBUS protocol) Hydronic Kit V33: 3 way valve with electric servocontrol, power supply 230V Accessory E: on/off damper servocontrol power supply 230 V PSTD: air filter pressure switch AIRFLOW CONTROL AQS is the ductable CO 2 sensor, it must be connected to the RQU control KAQ is the Air Quality control system; it includes: ductable CO 2 sensor modulating regulator 24V transformer DPS is a sensor for constant pressure working mode P KAQ TR AQS SV SV TM P RQU