Secure Keypads for access control



Similar documents
How To Program An Autodialer

Digital Keypad Use s Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

9452/9453 Installation and User Guide

TS510 & TS500. Installation & User Guide. Compatible Equipment

FIREDEX Conventional Fire Panels

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

AC-115 Compact Networked Single Door Controller. Installation and User Manual

CONTENTS 4. HOW TO UNSET THE PANEL...7

ACTIVE 5 ENGINEERING MANUAL

HARDWIRED CONTROL PANELS

Automatic Telephone Dialer TD-101(W)

Matrix 424/832/832+ ICON & LCD User Manual. Software Version 5 RINS EN Security Grade 2 Environmental Class 2

GSM Autodialer Professional GJD700 Speech & Text Autodialer

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

NESS D Zone Control Panel and Dialler OWNER S MANUAL

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

STAND-ALONE PROXIMITY ACCESS CONTROL SYSTEM

How To Set A Timer On A Gg System

SYSTEM 7000 IRIS+ USER MANUAL

Solution 862 Operators Manual. Issue 1.00

SCORPION. micron security products

Using your LED Plus keypad

GERONIMO ANALOGUE HEAVY DUTY TELEPHONE

IMPORTANT USER INFORMATION

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

User s Information Guide R1A

User Manual Wireless Alarm System RINS PIEZO WARNING The wireless system contains a loud siren, please be aware of this after an activation

WIRELESS HOME ALARM SYSTEM (WHA1)

500r+ Installation and User Guide

Solution-16 Operators Manual ISSUE 1.60

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

MANUAL GSM CONTROLLER

9448 Installation and User Guide

Users Guide to Keypad Functions

Control/Communicator Installation Manual

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

Business/Home GSM Alarm System. Installation and User Manual

Quick Installation Guide LCD GSM ALARM SYSTEM LH

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

AD-01 Slave Auto Dialer. Owner s Manual

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

IDS X-Series User Manual D Issued July 2012

Diamond + User Manual. Wireless Alarm System. Default codes: User code: 1234 Master Manager Code: 2222

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

PAC1 Door Access Controller

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

Intruder alarm system Operating Instructions

User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up

Security System User Guide

AUTODIALLER / QUICKDIALLER - SA132

ACP10 10 Zone Intruder Alarm System

SELECTION, APPLICATION AND MAINTENANCE

Emergency Dialer DIAL-ALERT MODEL: AD

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

Microprocessor Home Security System

Auto Dialer. Manual E-921APQ E-921GPQ

Business/Home GSM. Alarm System(III) Installation and Users guide

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

User Manual. Wireless Alarm System. PIEZO WARNING: This wireless alarm system contains a 100dBA siren, please be aware of this after activation.

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

TS590. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT 0 ESC

User Guide Veritas 8/Veritas 8Compact/Veritas R8 INS036-5

PROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL

WD-AMX Water Detection Controllers

OPERATING INSTRUCTIONS

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T.

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

Solution-16 Operators Manual ISSUE 1.40

Operating Instructions. Keypad

Master User Guide Premier Elite 24/48/88/168/640

D200+ Auto-Dialler Installation/Operators Manual

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

User Manual. Before installation and use, please read the user manual carefully.

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation.

DC-8706K Auto Dial Alarm System

Business/Home. GSM Alarm system

ATS Control Panel. User s Manual

The RIDZ 8x2 Audio Switcher

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

WITURA CORPORATION SDN BHD

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

CAD-05 Kit GSM Auto Dialer. Owner s Manual

User Guide Premier Elite 24/48/88/168/640

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

MODEL DK-26 DIGITAL KEYPAD SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Solution 16 plus. User Guide Security System

Wireless Home Security Alarm System AM 500

Speech Dialler Engineering Information

Control Box Wiring For PRSstandard Tool

Transcription:

torm Secure Keypads for access control Strike Master Read this manual carefully before attempting to install, program or operate the STORM AXS Strike Master Keypad. After installation the Command Summary Chart at the back of this manual can be used as a quick reference to programming and operating s. Page Section Contents 1 i) Introduction and Factory Defaults 2 ii) Installation Instructions iii) Electrical and Data Connections; Circuit Schematic 3 iv) Code Entry Mode v) Programming Mode 4 vi) Adding and Removing Codes 5 vii) Changing Door Strike Times viii) Setting the Invalid Code Penalty Time 6 ix) Other Features. Remote Exit, Alarms, Relay 2, Door Monitoring, Entry Under Duress, Alarm Signals 7 x) Code Index Directory 8 xi) Command Summary Chart i) INTRODUCTION AND FACTORY DEFAULTS Storm AXS Strike Master Keypads provide comprehensive access control for all outdoor and indoor locations. Door / system status is indicated by a high intensity LED light source and an audible sounder. Storm AXS Strike Master Keypads are specified to survive in different service environments, ranging from exposed unsupervised public locations to general service indoor applications. Keypads in the Storm AXS Strike Master range are dimensionally and electrically interchangeable. This allows users, entering codes at both outdoor or indoor access points, to establish and maintain familiarity with the keypad features. Up to 50 user programmable entry codes Entry Code indexing system provides a directory of authorised code holders and permits secure allocation and re-allocation of entry codes 4, 5, or 6 digit entry codes One or two door control Anti-tamper alarm Entry code entered under duress alarm Hidden entry code feature Forced door alarm Timed strike or latching door operation Timed lock out for repeated invalid code input Remote switch exit facility Fail (open) Fail (closed) option All weather resistant Two protection levels anti vandal keypad for unsupervised public, outdoor locations robust keypad for regular outdoor / indoor locations The STORM AXS Strike Master Keypad is supplied with the following factory configured defaults. Default settings FEATURE Engineer s code Door 1 Strike Time Door 2 Strike Time Invalid code Penalty time Relay 2 output Relay 2 Configuration Door Sensor FACTORY SET DEFAULT 111111 (For security, change default engineer s code on installation) 5 seconds 5 seconds 15 seconds Set in Alarms Mode Relay Output set normally open Bridged. Remove wire bridge to enable this feature

2 ii) INSTALLATION INSTRUCTIONS Fixing Instructions (Please read carefully before attempting installation.) Rear Casing 1. Select a suitable location with a sound flat surface. Using the case as a template, mark the position of the four fixing holes (A) on the surface. 2. Drill and plug the fixing holes to suit fixing screws (E) as supplied. 3. Locate the anti-tamper switch actuator plate (F) on the rear face of the case in the position as shown. The fixing screws (E) may be positioned in the case to assist in the accurate location of the plate. 4. Locate the thicker (6mm) sealing gasket (B) on the rear face of the case before positioning the case over the fixing holes (A). (Be sure to run the cable through the hole in the gasket prior to securing the case.) 5. Secure the case to the surface using the fixing screws (E) as supplied. Keypad to Casing 6. When making the electrical connections to the connector block care should be taken not to damage the thin sealing gasket (C) fixed to the front face of the rear case. [For connection details see section iii) of this manual.] 7. Fix the keypad to the rear case using the thread forming security screws (D) as supplied. (Please ensure the nylon sealing washers are located beneath the head of the security screws (D). Please note a special bit is provided for tightening these screws. 8. Check the installation to ensure gaskets are in place and compressed evenly around the perimeter of the case. Note: On rough or uneven surfaces it may be necessary to apply a bead of silicone sealant around the inner face of the case at the point where it meets the mounting surface. Where this method of sealing is necessary the thicker sealing gasket (B) must not be fitted. D 1 2 3 4 5 6 7 8 9 0 C E F B A iii) ELECTRICAL AND DATA CONNECTIONS Door Sensor Remote/ Exit Switch Door Strike Door/call Bell Alarm Bell/ Klaxon 10. Remote Switch - To open door 1 from within secure area 9. Door Sensor - Used to monitor door 1 condition (open/closed) 8. Door/Call Bell - Open collector gate 7. Alarm/Door 2 Release Relay - Fully floating (volts free contact) 6. Alarm/Door 2 Release Relay - Fully floating (volts free contact) 5. Door 1 Release Relay - Relay output (normally closed) 4. Common - Relay common 3. Door 1 Release Relay - Relay output (normally open) 2. Supply - Range 11 to 28 volts dc or 9 to 20 volts ac. 1. Return - Zero volts Power Supply +V 0V Note: When making connection to the door strike, select relay normally open or relay normally closed to suit the intended application and locking mechanism. Note: To achieve maximum protection against EMC, RFI, or damage from Electro-static Discharge it is recommended that the keypad casing is earthed (grounded) via the screw terminal attached to the metal shield on the rear face of the keypad.this terminal is identified by a symbol. It is recommended that a regulated, fully isolated power supply is used to power the StrikeMaster keypad. (Keymat Technology part no. DEPS0101 or DEPS0201 or equivalent). Bifular wound supplies are not recommended.

iv) CODE ENTRY MODE During everyday operation the keypad will be in code entry mode or logged off. This is also the mode that the keypad is in when it is first powered up. When the keypad is in code entry mode the LED will light red to signify that the keypad is waiting for either an entry code or the engineer s code to be entered. 3 When entering a code, spurious digits may be entered before and after the valid code to help disguise it from onlookers or other surveilance (maximum 20 characters to be entered at any one time). [Care should be taken not to activate the Operator Under Duress alarm by prefixing a valid entry code with the numbers 9 1. [see section ix) - Activating the Operator Under Duress Alarm]. Entry codes should not begin with the numbers 9 or 1 as this can also lead to non intentional triggering of the Operator Under Duress Alarm. [see section vi) - Adding and Removing Codes].] When a valid entry code has been entered the door strike will release for the period of the strike time [see section vii) - Setting the Door Strike Time] or latch open, depending on what type of code was entered [see section vi) - Adding and Removing Codes]. The LED will light green to signify that the door lock is in a released (or open) condition. v) PROGRAMMING MODE RE-ALLOCATE ENGINEER'S CODE To enter programming mode it is required that the operator logs on by entering the engineer s code. When logging on the engineer s code must be preceded by the # key. If the code is correct the LED will start flashing (red and green alternately) to signify that the operator has logged on and that the keypad is in programming mode ready to accept commands. For security reasons it is essential that the default engineer s code is replaced with your own six digit code. Please ensure a record of the code is kept in a secure place. If code is not known 'Power Down' then Power Up 7 2 5 to log on If the engineer s code is not known, power down the keypad for a period of not less than three seconds. Power up the keypad and within a two minute period enter the code 725. Do not enter any other digits before entering this code. The keypad s LED will then begin flashing to indicate that the keypad is in programming mode. Install a new engineer s code; (Refer to the chart on this page) Once in programming mode the operator can use the commands, as summarised in Sections v) - viii) to set up the keypad. After each segment of a is entered the keypad will give a rising tone bleep to indicate that it has accepted the data and is ready for the next segment of the command. If at any stage the keypad gives an error bleep (decreasing pitch) then the data entered is invalid. The keypad will remain in programming mode but you must re-enter the whole of the within which the error bleep occurred. 1 to 8d NO # To select new 4d d0 0 new 6 digit d0

4 vi) ADDING AND REMOVING CODES To add or remove entry codes log on, then follow the appropriate detailed below. Notes: a). Entry Codes should not start with numbers 9 or 1. b). Each entry code recognised by the keypad is stored under a two digit reference known as the Code Index Number. The code index number allows an authorised holder of the engineer s code to remove entry codes by keying in the code index number without having knowledge of the actual entry code. It also means that a written record of valid code holders can be kept without recording the actual entry codes. [see section x) - Code Index Directory]. c). Prior to operation of a second door, relay 2 must be set for door control. [see section ix) - Contolling a Second Door]. REMOVING CODES There are 2 options for removing codes - remove a single code or remove all codes Index allocated - delete fields ADDING CODES To add an entry code d1 the 2 digit index number (max 50) dx X Index allocated - try another Index No. Remove an Index Field d Remove all Index Fields d 2 3 Select door and mode of entry required for this entry code Index number from which code is to be removed X X d0 0 Door 1 Timed Door 1 Latched Door 2 Timed 1 2 3 4 Door 2 Latched 4,5 or 6 to correspond to no. of digits in code (4) 4 or (5) 5 or (6) 6 new code 1 to 8d NO d0

vii) CHANGING DOOR STRIKE TIMES 5 I) Setting the Door 1 Strike Time The door strike time is the number of seconds for which the door lock remains released (or open) when a valid entry code is entered. To set the Door 1 strike time, log on, then enter 5 to select the Door 1 Strike Time Set Up function. Listen for the accept bleep Then enter a two-digit number to set the duration of the strike time in seconds (00-99) Listen for the accept bleep ii) Setting the Door 2 Strike Time To set the Door 2 strike time, log on, then enter 6 to select the Door 2 Strike Time Set Up function. Listen for the accept bleep Then enter a two-digit number to set the duration of the strike time in seconds (00-99) Listen for the accept bleep. 1 to 8d To re-allocate door strike times Door 1 Door 2 d5 Strike Time in seconds dx X d0 d6 viii) SETTING THE INVALID CODE PENALTY TIME When in Code Entry mode, if after twenty key presses a valid code has not been entered, the keypad will be disabled for a pre-set period of time. This feature is intended to deter any attempt to gain unauthorised access by guessing the format of a valid code. To set the Invalid Code Penalty Time, log on, then enter 7 to select the Invalid Code Penalty Time function. Listen for the accept bleep. Then enter a two-digit number to set the duration of the Penalty Time in seconds (00-99) Listen for the accept bleep. 1 to 8d To reset Invalid Penalty Time d7 Penalty Time in seconds dx X d0

6 ix) OTHER FEATURES a) The Remote Exit / Egress Switch Making a connection (via a suitable momentary contact switch) between connector terminals 10 and 1 (return) will release (or open) the door lock for a pre-set period of time (the door strike time). This feature can be used to provide a remote exit facility, allowing personnel to exit from a secure area by pressing a button located near or adjacent to the door (on the secure side only). [see sections vii) and viii) for information about setting the door strike time]. Please note, in 2 door operation the connection of a remote egress switch to control the second door is not possible. b) Alarms An alarm bell or klaxon can be activated via connector terminals 6 and 7. When the keypad enters an alarm state (door forced or operator under duress or anti-tamper), these two terminals will provide an alarm signal (2 Amps max. at 30 Volts DC). The alarm bell or klaxon should be connected as shown in section iii) - Electrical & Data Connections. Please note that the alarm bell or klaxon is not powered from the keypad and so must have an independent power supply. An alarm signal can be cancelled by keying in any valid entry code or the engineer s code. If the cause of the alarm can be rectified (i.e.the Anti-Tamper switch can be re-closed, or a forced door can be closed), then keying in a valid Entry Code will silence and reset the alarm. If for any reason the cause of the alarm can not be rectified (e.g. The keypad has been forced away from the wall, or the door has been damaged and can not be closed), then the alarm can be silenced by keying in a valid Entry Code twice (2 times). When the alarms have been silenced in this way, the keypad must be isolated from the power for a minimum of 3 seconds to reset the alarm feature. Note if the alarm function is used to indicate operator under duress then the alarm should be discreet, i.e., situated in a remote location beyond the audible or visual range of an attacker or intruder. The alarm feature can be used to interface with a centralised alarm system or to trigger a synthesised or pre-recorded auto dial telephone message to a chosen monitoring station. Alternatively, terminals (6 and 7) can be used to control a second door. [Refer to section ix) c) - Controlling a Second Door]. c) Controlling a Second Door (one keypad controls access through two doors) Connector terminals 6 and 7 can be used as a relay output to control a second door. When the keypad is used for second door control the Alarms feature will be disabled. To configure the keypad for second door control, log on, then enter 8 to select Relay 2 Set Function. Listen for the accept bleep. Then enter 1 to configure the relay for second door control, or enter 0 to re-configure the relay as an alarm output. Listen for the accept bleep. (Refer to chart opposite) d) Door Monitoring (Door 1 only) In its factory fitted format, the door sensor is disabled. This is because the hard wire bridge is connected between terminals 9 and 1 (0V Return and the Door Sensor). This disables the door forced alarm feature. To utilise the door sensor, remove the hard wire bridge and connect the door sensor to terminals 1 and 9. 1 to 8d e) Activating the Operator Under Duress Alarm The Operator Under Duress Alarm can be activated at any time by prefixing a valid entry code with the numbers 9 1. Note: if there is any possibility that this feature will be used, any visible or audible alarm indicators must be located out of audible and visual range of any attacker or intruder. [Refer to section ix) b) - Alarms]. f) Alarm Output Signal SETTING THE ALARM / SECOND DOOR OPTION To select Alarm or Second Door option d8 Alarm d0 d0 Second Door Control d1 FEATURE SIGNAL COMMENTS Duress Relay does not oscilate; stays silent so as not to alert intruder Door Forced Anti Tamper 0 1 2 3 4 5 6 7 time (secs)

x) CODE INDEX DIRECTORY CODE INDEX NO. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 CODE HOLDER NAME OF PERSON/DEPARTMENT DOOR TYPE OF CODE 1 2 LATCHED TIMED 7 FEATURE Engineer s Code Door 1 Strike Time Door 2 Strike Time Invalid Code Penalty Time Relay 2 Output Relay 2 Configuration FACTORY SET DEFAULT 111111 (change on installation) 5 seconds 5 seconds 15 seconds Alarms Mode Normally Open OWNER SET CODES (record separately in safe location)

8 (Detailed xi) COMMAND SUMMARY CHART explanation of s are located in sections v) to ix). v) RE-ALLOCATE ENGINEER'S CODE To select new d4 d0 0 new 6 digit # If unkown refer to Programming Mode / Section v) vi) REMOVING CODES vi) ADDING CODES vii) CHANGING DOOR STRIKE TIMES There are 2 options for To add an To re-allocate removing codes - remove a single Entry Code door code or remove all codes d1 stike times Index allocated - try another Index Index No. the 2 digit allocated index number (max 50) - delete fields X d X Door 1 Door 2 d5 d6 Remove an Remove all Index Field Index Fields Select door and mode of entry required 2 d 3 d for this entry code Strike Time Index in seconds d0 0 number from dx X which code is to be removed Door 1 Door 1 Door 2 Door 2 Timed Latched Timed Latched X X 1 2 3 4 4,5 or 6 to correspond to no. of digits in code (4) 4 or (5) 5 or (6) 6 new code 1 8 d to NO d0 viii) SETTING THE INVALID PENALTY TIME To reset Invalid Penalty Time d7 Penalty Time in seconds dx X ix) SETTING THE ALARM/ SECOND DOOR OPTION To select Alarm or Second Door option d8 Second Door Alarm Control d0 d1 Whilst every effort is made to ensure that information given in this document is correct at time of print, Keymat Technology Ltd. can not be held responsible for any errors contained within. STORM, AXS, STRIKE MASTER & CODE MASTER are trademarks of Keymat Technology Ltd, England.