Seismic Isolation Retrofitting of Japanese Wooden Buildings

Similar documents
6 RETROFITTING POST & PIER HOUSES

SEISMIC RETROFITTING OF STRUCTURES

Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories

EXAMPLES OF SEISMIC RETROFITTING IN JAPAN

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE

Important Points: Timing: Timing Evaluation Methodology Example Immediate First announcement of building damage

Rehabilitation of a 1985 Steel Moment- Frame Building

Page & Turnbull imagining change in historic environments through design, research, and technology

PERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

Breakaway Walls

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Project Report. Structural Investigations Hotel del Sol Yuma, Arizona

STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA

Chapter 6 ROOF-CEILING SYSTEMS

Numerical Analysis of the Moving Formwork Bracket Stress during Construction of a Curved Continuous Box Girder Bridge with Variable Width

SEISMIC DESIGN OF HIGHWAY BRIDGES

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

Seismic Isolated Hospital Design Practice in Turkey: Erzurum Medical Campus

CH. 2 LOADS ON BUILDINGS

3. Observed Damage in Railway Viaducts

Methods for Seismic Retrofitting of Structures

Residential Deck Safety, Construction, and Repair

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

DESIGN SPECIFICATIONS FOR HIGHWAY BRIDGES PART V SEISMIC DESIGN

REVISION OF GUIDELINE FOR POST- EARTHQUAKE DAMAGE EVALUATION OF RC BUILDINGS IN JAPAN

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

Hunter College school of Social Work Thesis Proposal

SEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE

STRUCTURAL DAMAGE OF A 5-STOREY BUILDING: DIFFERENTIAL SETTLEMENT DUE TO CONSTRUCTION OF AN ADJACENT BUILDING OR BECAUSE OF CONSTRUCTION DEFECTS?

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California Prepared By

Technical Notes 3B - Brick Masonry Section Properties May 1993

Seismic Risk Prioritization of RC Public Buildings

THE REPORT ON THE INVESTIGATION OF THE REACTORS AT FUKUSHIMA DAIICHI NUCLEAR POWER STATION (NO. 1)

What is Seismic Retrofitting?

Guidelines for Promotion of Earthquake-resistance School Building July 2003

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

HOUSE BUILDING DIGEST

REPAIR AND RETROFIT OF BRIDGES DAMAGED BY THE 2010 CHILE MAULE EARTHQUAKE

The Original Carbon Fiber Reinforced Polymer System

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

Formwork for Concrete

Seismic Retrofitting for School Buildings in Japan Nonstructual Seismic Retrofitting

Expected Performance Rating System

ASHULIA APPARELS LTD. Client Summary Report

Current Status of Seismic Retrofitting Technology

Performance-based Evaluation of the Seismic Response of Bridges with Foundations Designed to Uplift

How To Design A Post Tensioned Deck For A Building

Seismic Risk Evaluation of a Building Stock and Retrofit Prioritization

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

SECTION 7 Engineered Buildings Field Investigation

Development of Seismic-induced Fire Risk Assessment Method for a Building

In this study analytical investigation of effect of retrofit application using carbon fiber (CFRP) on seismic behavior of a monumental building at

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Optimum proportions for the design of suspension bridge

Elevating Your House. Introduction CHAPTER 5

Chapter 2 Basis of design and materials

Detailing of Reinforcment in Concrete Structures

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

Analysis of the Response Under Live Loads of Two New Cable Stayed Bridges Built in Mexico

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

Chapter 3 Pre-Installation, Foundations and Piers

DAMAGE TO WOOD BUILDINGS DURING THE GREAT TOHOKU EARTHQUAKE PART2- DAMAGE DUE TO GROUND MOTION

Measuring the Condition of Prestressed Concrete Cylinder Pipe

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

Rehabilitation of Existing Foundation Building to Resist Lateral and Vertical Loads

Chapter. Earthquake Damage: Types, Process, Categories

Seismic Retrofit of Bridges - A Short Course

Retrofitting By Means Of Post Tensioning. Khaled Nahlawi 1

SEISMIC RETROFIT DESIGN CRITERIA

SIKA AT WORK THE KAENG KRACHAN ELEPHANT HOUSE AT ZURICH ZOO

Vibration Isolation in Data Centers

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

Photo 2. View showing flour mill, machine shed, veranda and saw mill + storage shed.

POST AND FRAME STRUCTURES (Pole Barns)

COMMONLY USED RESIDENTIAL BUILDING CODES

Lighthouse Engineering, L.L.C.

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE

SEISMIC CAPACITY OF EXISTING RC SCHOOL BUILDINGS IN OTA CITY, TOKYO, JAPAN

Seismic performance evaluation of an existing school building in Turkey

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

CONTRIBUTION TO THE IAEA SOIL-STRUCTURE INTERACTION KARISMA BENCHMARK

Cover page. Introduction to the Earthquake Resistance Capacity Assessment and Reinforcement of Taipei Water Department Office Building.

Buildings Construction Procurement Strategy

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

Design and Construction of Cantilevered Reinforced Concrete Structures

Engineers at Liftech designed the structure of the first container crane and have designed and reviewed thousands of container cranes since.

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

Transcription:

Seismic Isolation Retrofitting of Japanese Wooden Buildings Summary Junko Suga Building Design Department Takenaka Corporation, Osaka Main Office Osaka, Japan Hiroyuki Ueda Building Design Department Takenaka Corporation, Osaka Main Office Osaka, Japan Base-isolation retrofitting for a pair of 145-year-old wood shrines, with Japanese traditional architectural style, is introduced. In the renovation, lateral stiffness and strength of the superstructures are increased by traditional wood works such as wood piecewise-walls and beamcolumn joints. Additionally high endurance concrete and epoxy resin coated reinforcing bars are used for the newly constructed structure. Existing shrine buildings were lifted up 2m and set on a temporary pedestal to construct isolation system under it. 1. Introduction Fig. 1 Exterior view Takebe-taisya Shrine locates at southeast of Lake Biwa in Shiga Prefecture, Japan and has a long and distinguished history. Its historical records tell the place was hit by a big earthquake in 1627 and most of the shrines collapsed. The existing Honden and Gonden, which are main buildings in the shrine, were built in parallel and in the same shape in 1861 after a long absence. Their exterior view is shown in Fig. 1. Honden and Gonden enshrine Yamatotakeru-nomikoto and Oonamuchi-no-mikoto respectively. The former and the latter are a hero and a god respectively in Japanese myths. But they believe the former is an existed prince lived around the 2 nd century. Base-isolation retrofitting has been applied to the two buildings. 2. Japanese Structural Design of Seismic Isolated Structure One of major methods to design seismic isolated structure in Japan is to determine static earthquake loads by the maximum response values of earthquake response analysis. The analyzed loads are used in static stress analysis and each element is designed by design method. Based on the above method, in this building design, earthquake response analysis is done on the following 2 levels. 1. Rare earthquake motion: level 1 earthquake motion 2. Extremely rare earthquake motion: level 2 earthquake motion The earthquake motions for each level are scaled three observed motions and three motions compatible to spectra defined by Japanese seismic code. Motions compatible to spectra are made based on the following method. First, surface ground model above engineering bed rock is defined. Here, engineering bed rock is chosen from ground, which has more than 400m/sec shear wave velocity. Second, acceleration at the engineering bed rock is convolved to the surface ground considering nonlinear characteristics of the soil layers. The resulted earthquake motions are to be input at the foundation of the building model of earthquake response analysis. Here, these earthquake motions are called code spectra compatible motions.

3. Outline of the Building Outline of the buildings is described below. The 28,000m 2 lot has more than 20 buildings with variety of sizes as shown in Fig. 2. Worshippers come from the west and turn to the north along the main street, and go through the gate toward Honden and Gonden. The buildings are surrounded by holy fences with a grove of the shrine on their right backs. Fig.3 shows architectural plan, Fig.4 and Fig.5 show cross section and south elevation view. OUTLINE Building name: Takebe-taisha shrine / Honden and Gonden Building site: Otsu City, Shiga Prefecture, Japan Completion: March, 2006 (retrofitting work) Building area: 21.38m 2 Floor area: 6.54m 2 Building height: 6.62m Superstructure: Japanese traditional wooden structure Base isolation system: Ball Bearings, Oil Dampers Foundation: Mat foundation, Soil improvement CHINA NORTH KOREA SOUTH KOREA Lake Biwa RUSSIA JAPAN Takebe-taisha shrine Honden Gonden Grove of the shrine Kidan Honden Gonden Office Gate 5,882 Parking lot Main street 10,492 Fig. 2 Layout plan 50m Holly Fence Fig. 3 Plan (unit mm) Fence Kidan Kidan FL GL 300 5,924 1,667 1,61 3,279 Fence Existing New Fig. 4 Cross section (unit mm) Fig. 5 South elevation

4. Structural Planning 4.1 Structural outline Fig. 6 and Fig. 7 show isolation device layout and Kidan floor level framing plan respectively. Fig. 8 describes applied structural methods on a framing elevation drawing. Ball bearing isolators and oil dampers are installed underneath a reinforced concrete floor slab, which is newly constructed to support the shrines. Fig. 9 is a photo of the isolation devices set in the pit during construction. Ball bearing isolators have isolating and restoring function, and oil dampers give appropriate damping force. One of strengthening concepts for the superstructures is to keep traditional structural methods as much as possible. Based on this, weathered wood piecewise-walls, OTOSHIKOMI-ITAKABE and beam-column joints are improved. High endurance concrete and epoxy resin coated reinforcing bars are applied to the all new structure to cover the long life span of cypress used for the superstructures. Furthermore, to prevent liquefaction, Grid-Form Ground Improvement work has been adopted. It also supports the whole building weight at the base slab. 1,612 2,117 Ball Bearing BB2N-2 (2 inch ball) BB3N-2 (3 inch ball) Oil Damper C=30kN s/m 1,985 4,196 1,985 Fig.6 Isolation device layout (unit mm) Access opening 1,985 4,196 1,985 Fig. 7 Kidan floor level framing plan (unit mm) Ball Bearing isolator Oil Damper 1,000 @800 Replace Fig. 8 Framing elevation Wood piecewise-walls, OTOSHIKOMI-ITAKABE Beam, KOSHINUKI Kidan Isolation pit High endurance concrete Epoxy resin coated reinforcing bars Foundation Grid-Form Ground Improvement Fig.9 Isolation device layout in the pit (under construction)

4.2 Input earthquake motion In this project Level 1 and Level 2 earthquake motions are applied according to the Japanese code. Additionally to confirm seismic safety margin, LakeBiwaWestBankFaultEarthquakeMotion has been simulated as a site motion and applied, which is considered one of the largest earthquake with relatively high event probability at the site. Maximum velocity and maximum acceleration of each motion are illustrated in Table 1. Table 1 Input earthquake motion Code spectra compatible motion Earthquake Motion Motion A Hachinohe 1968 NS phase Motion B Kobe marine observatory 1995 NS phase Motion C Random phase Rare earthquake LEVEL 1 V cm/s A cm/s 2 Extremely rare earthquake LEVEL 2 V cm/s A cm/s 2 Site motion V cm/s A cm/s 2 13.1 116 73.4 544 12.2 113 71.8 511 11.0 116 55.4 501 Observed motion Simulated motion El Centro 1940 NS 25.0 256 50.0 511 Taft 1952 EW 25.0 249 50.0 497 Hachinohe 1968 NS 25.0 167 50.0 334 Biwa West Bank Fault Earthquake Motion 81.2 849 V: Velocity A: Acceleration 4.3 Restoring force characteristic of the superstructure The existing buildings did not have enough lateral stiffness and strength because they had less aseismatic elements. In this kind of case, a wooden building is reinforced by modern aseismatic methods like metal bracings or structural plywood in the past. However, like many Japanese shrines, their traditional structural members are finishing materials as they are. Therefore, traditional wooden works, which work as structural members, are chosen as reinforcement elements to keep their traditional external appearance as same as the original. The following two methods are applied to gain enough stiffness and strength. 196mm Before reinforcement After reinforcement Shear connector Wood piecewise -walls t=18mm 196mm Wood piecewise -walls t=30mm 196mm Little lateral stiffness Shear connectors transmit lateral load. Fig. 10 Structure of wood piecewise-walls 1. Wood piecewise-walls, OTOSHIKOMI- ITAKABE, are improved. Each wall consists of plural wooden boards connected each other by wooden shear connectors, DABOs, filled in a frame. Weathered 18 mm thick wallboards without DABOs are replaced by 30 mm thick wallboards with DABOs as shown in Fig. 10. 2. Beams, KOSHINUKI, are processed to penetrate the columns at its both ends as shown in Fig. 11. The joints are evaluated as semi-rigid joints.

beam column Fig. 11 Joint of beam and column Restoring force characteristics of the superstructures are evaluated and modelled for seismic response analysis referring to experimented studies. It evaluates boards compressive strain inclined to the grain of columns or girders, boards shearing deformation, slip between boards, and boards partial collapse by compression. Since there are no nail work used at any joints and small clearances exist between wood materials, restoring force of the superstructure shows slip from original point like dot-lines plotted in Fig. 12. Here, elastic nonlinear equivalent shear stiffness, which is plotted in solid line in Fig. 12, is defined and applied to models for earthquake response analysis. Additionally analysis is done also with a half of the initial stiffness K 1 and double of K 1. This variation of the initial stiffness is caused expansion and shrinkage of wooden elements caused by mainly fluctuant humidity of surrounded air. Damping ratio of the superstructures is set at 3% to critical, considering material shrinkage with age. 4.4 Isolation devices 608 Movable range: 270mm Ball diameter: 2inch θ1.5 Shear force F 1 F 2 -F 2 -F 1 Fig. 13 Ball Bearing isolator Shear force Equivalent shear stiffness used to in response analysis M g Restoring force Fr = Mg Displacement F 1 : Upbound intercept load F 2 : Downbound intercept load Displacement Elastic nonlinear Fig. 12 Restoring force characteristics of the superstructure Ball bearing devices illustrated in Fig. 13 and oil dampers are applied for the buildings to get appropriate isolation effect. This combination of devices has the following advantages besides the high performance. 1. [High reliability] already used in hundreds of houses in Japan 2. [Easy maintenance] less residual displacement after earthquake makes maintenance relatively easy for the owner. It can be said that materials have to behave prescribed performance with easy maintenance as well as they have to have high performance. 4.5 Result of the seismic response analysis 0 5 10 15 20 25 30 (cm) Fig. 14 Maximum response displacement (Level 2 and Site Motion) Generally a Japanese traditional building has very large and heavy roof. In this kind of building, when story displacement increases, a building itself collapse by P-delta effect, which made by the lateral displacement and the weight of the roof. Maximum displacement responses of the building are plotted in Fig. 14. Results show that maximum story drift is 1/93, by Lake Biwa West Bank Fault Earthquake Motion, which is less than the collapse limit of 1/30. Results of seismic response analysis are illustrated in Table 2. Stress of each element is less than to confirm high isolation effect.

Table 2 Criteria and result of earthquake response analysis Level 2 Lake Biwa West Bank Fault Earthquake Motion Criteria Result Criteria Result Wooden Superstructure Isolation level Foundation Story drift 1/60 1/131 1/30 1/93 Element stress Allowable stress Element strength Displacement 27cm 22.2cm 27cm 26.7cm Element stress Bearing capacity Allowable stress Allowable stress Ultimate stress Ultimate stress 5. High durable materials The existing superstructure is made of cypress. The material life span is more than several hundred years. To make the whole buildings life span long, high endurance concrete and epoxy resin coated reinforcing bars are used for the all newly built General structure, such as concrete foundation slab, concrete retaining walls and so on. Minimum covering depth (cm) 89 yrs W/C=55.0% In-serve Period (year) 6. Construction scheme Takebe-taisha W/C=44.1 Durability improving additives 8kg/m 3 768 yrs Fig. 15 Neutralization speed of concrete In high endurance concrete, neutralization is controlled because neutralization of concrete is one of dominant factors, which shortens the material life span. Neutralization is promoted by air included in the concrete itself and also in water led along cracks. To prevent concrete from neutralization, water-cement ration is restricted lower, and air in the concrete is reduced by adding durability improving additives. Relation between neutralization speed and covering depth is described in Fig. 15. More than 500 years of life span is expected for the concrete used in this project. Construction had to be done in very limited space because a grove of trees exist right behind on the north side of the buildings and also holy fences surround the buildings. To set isolation system, the fence on the north side was removed and the existing buildings were lifted up 2m with chain hoists as shown in Fig. 16 and Fig. 17. Each building was fixed on temporary steel pedestal set over the site and construction works were done under it. It enabled to use small size heavy machineries to excavate and carry soil out of the site. However, machineries for general ground soil improvement were still too tall to be operated under 2m high pedestal. To solve it, High Pressure Jet Agitation method is selected instead of general agitation method. In the method, big machineries were not necessary on the ground because soil is agitated by jet pressure of fixation agent in the ground. Additionally simple construction was achieved by a flat slab foundation without beams. It also reduces the amount of soil excavation and makes the concrete work simple.

2,000 Small size backhoe High pressure agitation method Temporary steel pedeltal aisle Bracing wall Fig. 16 Temporary steel pedestal plan 7. Conclusion Grid-Form Ground Improvement 1000800 Fig. 17 Temporary steel pedestal elevation Base-isolation retrofitting for Japanese traditional shrines is introduced. In the seismic renovation, Lateral stiffness and strength of the superstructures are given by traditional wood works such as piecewise-walls and beam-column semi-rigid joints. Use of metal elements for reinforcement is minimized. High endurance concrete and epoxy resin coated reinforcing bars are used to the newly constructed structure for base isolation, because the cypress of superstructure has more than hundreds year lifelong. Existing shrines are lifted up 2m and set on a temporary pedestal to make construction work enable under it. Only a few base-isolation retrofitting designs for traditional buildings are seen in Japan yet. This project will be one of the first examples of seismic isolation retrofitting for Japanese traditional buildings reinforced only by traditional wood works. It is expected that retrofitting by combinations of modern technology and traditional structural are developed more and get more popular. Additionally it is longed that, knowledge about damping effect of traditional wooden works increases in the future to design them more rationally.