Seismic Retrofitting for School Buildings in Japan Nonstructual Seismic Retrofitting
|
|
- Melvyn Hopkins
- 8 years ago
- Views:
Transcription
1 Seismic Retrofitting for School Buildings in Japan Nonstructual Seismic Retrofitting for School Buildings in Japan 8 January 2009 Koichi Shinpo Director, Educational Facilities Research Center National Institute for Educational Policy Research(NIER)
2 National Institute for Educational Policy Research The National Institute for Educational Policy Research (NIER) is a national institute dedicated to the broad study of educational policy in Japan Established in 1949 Total staff 158 persons Annual appropriation is approximately 4,100 million yen Organization Director General, Duputy Director General(2) 6 Departments for research 5 Research centers Department of general affairs
3 Educational Facilities Research Center Established in 2004 The latest research center in NIER Objective Implementation of fundamental and special research on educational facilities Collection and analysis of information about educational facilities Recent major research themes Seismic retrofitting for existing school buildings Environmentally friendly renovation for existing school buildings Safety and crime prevention of school buildings Barrier free of school buildings
4 Reference Book on Seismic Retrofitting for School Building Seismic Retrofitting Quick Reference School Facilities that Withstand Earthquakes Examples of Seismic Retrofitting What are the types of seismic retrofitting? Structural slits Is value How much does seismic retrofitting cost? Installing seismic shear walls Published by MEXT in September 2006 Contents - Examples of school buildings damaged by recent major earthquakes - Background information of seismic retrofitting - 8 examples of retrofitted school buildings - Other 14 simple description of seismic retrofitting cases How long does it take to retrofit? Steel bracings Website: What effects does seismic retrofitting have? Ministry of Education, Culture, Sports, Science and Technology
5 Seismic Resistance Capacity Evaluation of Existing Buildings Is (Seismic Capacity Index of Structure) : an index that defines the seismic capacity of existing reinforced concrete buildings Is Eo S T Eo basic structural seismic capacity index calculated by the product of Strength index (C), Ductility index (F) and Story Index ( ) Eo= C F S : reduction factor to modify Eo index due to the difference in structural balance in plan and elevation T : reduction factor allowed for time-dependent deterioration grade Evaluation of seismic capacity by Is When a large scale earthquake occurs Is 0.3 There is high risk of collapsing 0.3 Is 0.6 There is risk of collapsing 0.6 Is There is low risk of collapsing
6
7 [BEFORE] Floor Plan of Model Case (Ground Floor) [AFTER SFB Steel Frame Brace Reinforced Concrete Wall SP Column Reinforcement by Steel Plate SP SP SFB SP SFB SFB SFB SFB SFB SFB
8 [SOUTH] Section of Model Case SFB SFB SFB SFB SFB SP [NORTH] SFB Steel Frame Brace Reinforced Concrete Wall SP Column Reinforcement by Steel Plate ( Is index increased from 0.44 to 0.74 )
9 Earthquake resistant Method (1) Steel Frame Brace A construction method to attach steel frame braces to columns and beams Steel frame braces can be installed outside or inside the building Work at the construction site is comparatively easy Users can utilize the building even under construction
10 Earthquake resistant Method (2) Reinforced Concrete Wall A construction method to add reinforced concrete walls inside the building Construction period is comparatively longer Ventilation and lighting might be disturbed Construction cost is comparatively lower
11 Earthquake resistant Method (3) Column Reinforcement by Steel Plate or Carbon Fiber A construction method to attach steel plate or carbon fiber to columns Construction cost is comparatively higher Ventilation and lighting are not disturbed
12 Earthquake resistant Method (4) Out Frame A construction method to add reinforced components outside the building Ventilation and lighting are less-disturbed Construction inside the building is unnecessary Construction cost is comparatively higher
13 S lower secondary school (Shizuoka Pref.) 3,600 sqm / 4 stories SFB(outside) "Is" About 150 million yen About 41,100yen/sqm (only seismic retrofitting)
14 S elementary school (Chiba Pref.) 2,900 sqm / 4 stories SFB(outside) + "Is" About 455 million yen About 155,000yen/sqm (with improvement in quality)
15 T upper secondary school (Niigata Pref.) 3,200 sqm / 3 stories SFB(inner side) + "Is" About 174 million yen About 54,300yen/sqm (only seismic retrofitting)
16 S elementary school gymnasium (Tokyo) 610 sqm Addition of steel braces "Is" About 14 million yen About 22,000yen/sqm (only seismic retrofitting)
17 Reference Book on Non-structural Seismic Retrofitting for School Building - Published by NIER in December (NIER: National Institute for Educational Policy Research) Non-structural members can cause significant harm to children and others when a large earthquake occurs - Ceiling material, equipment and various fixtures can fall or topple - 19 case studies of non-structural members 1. Ceiling material 2. Window and windowpane 3. Exterior wall and siding 4. Lighting fixture 5. Outdoor unit (air conditioner and heating unit) 6. Elevated water tank and cooling tower 7. Chimney 8. Refrigerator 9. Bookshelf and locker 10. TV and computer 11. Piano 12. Machine tool 13. Storage shelves in special classes 14. Gymnasium equipment and facility 15. Shoe locker 16. Wall and gate post 17. External staircase and surroundings 18. Retaining wall 19. Others Website:
18 Ceiling Material Damage Falling ceiling materials at a special classroom Chuetsu Earthquake, Niigata Pref. - Fallen auditorium ceiling Hokkaido Southwest Offshore Earthquake Walls and columns Retrofitting Tie brace Provide space (gap) Daily inspection Confirm that tie braces are installed Confirm that intervals between hanging bolts are sufficient, and the bolts are tightened. Confirm that ceiling boards are not moved, cracked or deformed, and fasteners are not loosened or rusted. Retrofitting Provide sufficient space between ceiling materials and wall or column. When hanging bolts are long ( 1500 mm) due to the wide space between the roof and the ceiling, horizontal and diagonal tie braces should be installed to prevent the ceiling from moving.
19 Lightning Fixture Damage Retrofitting Fallen 2004 lighting Chuetsu fixture Earthquake, (chain pendant Niigata type) Daily inspection Confirm that lamp brackets and shades are not loose. Confirm that there is no rust or deterioration on brackets and shades. Hanging bolts 2004 Chuetsu Earthquake, Niigata Fallen lighting fixture (pipe hung type) Confirm that sway preventative braces are installed Fluorescent lamp Sway preventative braces Retrofitting Install modified hooks on brackets. Cover lamp chains with plastic tubes. Install sway preventative braces. Fix electrical raceways to columns or walls. Stainless steel wire Example of sway preventative brace
20 Bookshelf and Locker Damage Retrofitting 2004 Chuetsu Earthquake, Niigata Overturned bookshelves and lockers 2004 Chuetsu Earthquake, Niigata Fix and secure bookshelves and lockers Fix bookshelves and lockers to sturdy wall, beam or ceiling with metal brackets. Interconnect the tops among tall or shallow bookshelves. Fix stacked bookshelves or lockers at the base or the joint. Install a latch at the front opening door of the bookshelf or locker Chuetsu Earthquake, Niigata
21 Window and windowpane Damage Damaged windowpane hit by braces. Buckled bracing members stuck out in lateral direction and hit the windowpane. Other Damages - Damages attributed to the windowpane installation method - Damages caused by derailed windows and doors Retrofitting 1993 Hokkaido Southwest Offshore earthquake Prevent windowpanes from falling Apply anti-shattering film on sheet glasses to prevent them from shattering and falling. Confirm the loosening of windows. Adjust fixtures if necessary 2004 Chuetsu Earthquake Niigata Pref. Secure deformation of window members Stop using hard sealants to fix sheet glass to the window frame. Install windowpanes in accordance to the current design provision. Use bracing connections that prevent buckling of tie braces in lateral direction (Right photo).
22 Exterior Sidings (Concrete Block and ALC Walls) Damage Collapsed concrete block sidings Collapsed ALC and precast panel sidings 1995 South Hyogo Prefecture Earthquake Retrofitting 2005 Fukuoka Prefecture West Offshore Earthquake Internal view of the roof directly hit by collapsed block sidings Chuetsu Earthquake, Niigata Collapsed concrete block sidings Daily inspection Confirm that exterior sidings have not decayed such as loosening, uplifting, spalling or cracking Confirm that the shape and dimensions of fasteners are appropriate Prevent sidings from falling Repair spalling and cracked sidings by injecting resin Replace fasteners Reinforce or refurbish with other building methods
23 Piano Damage 2004 Mid-Niigata Prefecture Earthquake Retrofitting Grand piano The wheel restrainer was effective in restraining horizontal movement. Deeper seismic restrainers are more effective. Install a support frame to prevent the grand piano from overturning. Skidded grand piano Roller wheel Rubber seismic restrainer Upright piano Set upright pianos against the wall. Fix the piano on a board to prevent overturning.
24 Thank you for your attention!
Case Studies of Seismic Nonstructural Retrofitting in. School Facilities
Case Studies of Seismic Nonstructural in School Facilities December 2005 Educational Facilities Research Center, National Institute for Educational Policy Research, Study Group Report on the "Investigative
More informationSeismic Retrofitting Quick Reference School Facilities that Withstand Earthquakes Examples of Seismic Retrofitting
Seismic Retrofitting Quick Reference School Facilities that Withstand Earthquakes Examples of Seismic Retrofitting What are the types of seismic retrofitting? Is value How much does seismic retrofitting
More informationCurrent Status of Seismic Retrofitting Technology
CONTENTS Current Status of Seismic Retrofitting Technology Damages of Past Earthquakes Seismic Diagnosis Method Building Control Section Urban Building Division Bureau of Urban Development, TMG Seismic
More informationEARTHQUAKE DESIGN OF BUILDINGS
GAP.2.0.9 A Publication of Global Asset Protection Services LLC EARTHQUAKE DESIGN OF BUILDINGS INTRODUCTION Buildings in many areas of the world are susceptible to damage from moderate to severe earthquakes.
More information3. Observed Damage in Railway Viaducts
Structural Damage of Tohoku Shinkansen Viaducts by the Off the Pacific Tohoku Earthquake First Report on March 16, 2011 Dr. Yoshikazu Takahashi, Associate Professor Disaster Prevention Research Institute,
More informationWhat is Seismic Retrofitting?
What is Seismic Retrofitting? SEISMIC RETROFITTING A Seismic Retrofit provides existing structures with more resistance to seismic activity due to earthquakes. In buildings, this process typically includes
More informationSTRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA
STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA College of Marin c/o Swinerton Management & Consulting P.O. Box 144003 835 College Avenue, Building MS-3 Kentfield, California
More informationEAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
More informationGuidelines for Promotion of Earthquake-resistance School Building July 2003
Guidelines for Promotion of Earthquake-resistance School Building July 2003 Department of Facilities Planning and Administration, Ministry of Education, Culture, Sports, Science and Technology JAPAN Preface
More informationChapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE
Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE To satisfy the performance goals of the NEHRP Recommended Seismic Provisions, a number of characteristics are important to the
More informationEXAMPLES OF SEISMIC RETROFITTING IN JAPAN
09-031 The 2005 World Sustainable Building Conference, EXAMPLES OF SEISMIC RETROFITTING IN JAPAN Hiroshi YAMAMOTO 1 Yasuhiro TSUNEKI 2 Toshihiko KOHNO 3 1 Senior Structural Engineer, Structural Engineering
More informationSECTION 7 Engineered Buildings Field Investigation
SECTION 7 Engineered Buildings Field Investigation Types of Data to Be Collected and Recorded A field investigator looking at engineered buildings is expected to assess the type of damage to buildings.
More informationBuilding Condition Assessment: 215-219 West Lexington Street Baltimore, Maryland
KPA The Joint Venture of EBA Engineering, Inc. and Kennedy Porter & Associates, Inc. 4813 Seton Drive, Baltimore, MD 21215 Phone: (410-358-7171) Fax: (410)358-7213 Building Condition Assessment: Baltimore,
More informationExpected Performance Rating System
Expected Performance Rating System In researching seismic rating systems to determine how to best classify the facilities within the Portland Public School system, we searched out what was used by other
More informationEARTHQUAKE SAFETY IN THE WORK PLACE
EARTHQUAKE SAFETY IN THE WORK PLACE COMPANY PLANS All companies have an obligation to their employees to maintain a disaster plan. An emergency evacuation area must be designed, a nearby safe area, preferably
More informationINSTALLATION. General. Important Note. Design. Transport
General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected
More informationMark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
More informationElevating Your House. Introduction CHAPTER 5
CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More informationSTRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA
STRUCTURAL ASSESSMENT FOR Full Metal Jacket Building 0 Prince Street, Prepared by: ALPHA CORPORATION (Alpha) 1850 S. Loudoun Street, Suite 200 Winchester, VA 22601 540-723-0704 September 22, 2010 J. Michael
More informationStructural Failures Cost Lives and Time
Structural Failures Cost Lives and Time Recent failures of storage bins, silos and other structures highlight the need to increase awareness of hazards associated with these structures. Since 2010, one
More informationExcerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
More informationFacility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components
Infrastructure Facility Condition Summary Weighted Avg Condition Score Facility Components Systems Surveyor/ Date Done Comments G Sitework.9 Site Improvements Parking Pedestrian Paving Site Development
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationDiscussion on Products under the Scope of EN 1090-1 and proposed CEN/TR to clarify the scope
CEN/TC 135 N 686 European Committee for Standardization Comité Européen de Normalisation Europäisches Komitee für Normung CEN/TC 135 Execution of steel structures and aluminium structures N 686 Secretariat:
More information6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
More informationVOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10
VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1
More information48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.
Classification: Cluster: Location: Total Area: No. of Stories Aquarium Acreage Owned: Acquired: 1904 Most Recent Improvements: THE AQUARIUM Close to junction of Inselrhue and Loiter Way, Belle Isle Two
More informationPOST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
More informationSECTION 3 ONM & J STRUCTURAL ANALYSIS
Historic Boynton Beach High School Existing Building Assessment City of Boynton Beach February 10, 2011 SECTION 3 ONM & J STRUCTURAL ANALYSIS STRUCTURAL ENGINEERS SPECIAL INSPECTORS STRUCTURAL CONDITION
More informationProject Report. Structural Investigations Hotel del Sol Yuma, Arizona
Project Report Structural Investigations Yuma, Arizona Prepared by: 2619 Spruce Street Boulder, CO 80302 303-444-3620 Prepared for: Principle Engineering Group, Inc. 833 East Plaza Circle, Suite 100 Yuma,
More informationTitle: Attic Keyword: Structure Description: roof framing rafters and decking File Name: P1030062
Title: Attic Description: Roof Structure framing File Name: P1030060 Title: Attic Description: roof framing rafters and decking File Name: P1030062 Title: Bathroom Keyword: Plumbing Description: Aged fixtures
More informationHunter College school of Social Work Thesis Proposal
Fall 2009 Hunter College school of Social Work Thesis Proposal To analyze how energy efficiency can be implemented using facade and green roof redesign. It ties structural engineering concepts with existing
More informationStructural Audit of Buildings
International Journal of Civil Engineering Research. ISSN 2278-3652 Volume 5, Number 4 (2014), pp. 411-416 Research India Publications http://www.ripublication.com/ijcer.htm Structural Audit of Buildings
More informationREVISION OF GUIDELINE FOR POST- EARTHQUAKE DAMAGE EVALUATION OF RC BUILDINGS IN JAPAN
10NCEE Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 21-25, 2014 Anchorage, Alaska REVISION OF GUIDELINE FOR POST- EARTHQUAKE DAMAGE EVALUATION OF RC
More informationManufactured Home Inspection Checklist
Where building safety research leads to real-world solutions. Manufactured Home Inspection Checklist Nearly eight percent of the U.S. population lives in a manufactured home, according to the U.S. Census
More informationBuilding Condition Assessment: 109-111 North Howard Street Baltimore, Maryland
KPA The Joint Venture of EBA Engineering, Inc. and Kennedy Porter & Associates, Inc. 4813 Seton Drive, Baltimore, MD 21215 Phone: (410-358-7171) Fax: (410)358-7213 Building Condition Assessment: Baltimore,
More informationwww.citiesinspection.com October 5, 2015 Dear Client,
www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.
More informationSECTION 8 Industrial Facilities Field Investigation
SECTION 8 Industrial Facilities Field Investigation Types of Data to Be Collected and Recorded Warehouses, manufacturing facilities, energy-producing facilities, and factories should be inspected for performance
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationSEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS
Fracture Mechanics of Concrete Structures Proceedings FRAMCOS-3 AEDIFICA TIO Publishers, D-79104 Freiburg, Germany SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS H.
More informationHamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year
Hamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year Printed On: 2003/04/03 St Patrick CES, 7932 Study [03.3-050 Plumbing Piping Systems] Study condition, remaining service
More informationScope of EN 1090-1 Clarification Document
Scope of EN 1090-1 Clarification Document This document has been submitted to the European Commission as the UK view on the scope of EN 1090-1. After discussions, including with the European Technical
More informationGUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY
GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY July 2008 1.0 SCOPE These guidelines describe the way in which air conditioning units shall be installed or replaced
More informationFoundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training
Foundations 65 5 FOUNDATIONS by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. 66 Foundations Foundations 67 FOUNDATIONS Let's assume that the retrofit has been done correctly from the roofline
More informationSTRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
More informationSINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS
CITY OF BEAVERTON Community Development Department Building Division 12725 SW Millikan Way / PO Box 4755, Beaverton, OR 97076 Phone: (503) 526-2493 Fax: (503) 526-2550 General Information (503) 526-2222
More informationUNIVERSITY OF CALIFORNIA, SAN DIEGO
UNIVERSITY OF CALIFORNIA, SAN DIEGO UCSD BERKELEY DAVIS IRVINE LOS ANGELES MERCED RIVERSIDE SAN DIEGO SAN FRANCISCO SANTA BARBARA SANTA CRUZ UNIVERSITY CENTERS - 0076 PHONE: (858) 822-4987 9500 GILMAN
More information4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.
Shear Walls Buildings that use shear walls as the lateral force-resisting system can be designed to provide a safe, serviceable, and economical solution for wind and earthquake resistance. Shear walls
More informationStructural Assessment Report
Report Dallas Township Elementary School Dallas, Pennsylvania (JBCI Project No. 144911) 1655 Suburban Station Building 1617 John F. Kennedy Boulevard Philadelphia PA 19103 215 665 0497 5 Sandwood Drive
More informationChapter. Restoration of Damaged Structures
5 Chapter Restoration of Damaged Structures Bringing back a damaged structure to its pre-earthquake state and original strength is called restoration. This is the first step of building rehabilitation.
More informationSECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request
SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table
More informationProperty Condition Assessment
Property Condition Assessment Business, Wisconsin Inspection Date: 8/2009 Prepared For: Business Owner Report Number: TD999909 Prepared By: Shamrock Building Inspection Consultants LLC N29 W29951 Shel-Mar
More informationThe Federal Alliance for Safe Homes, Inc. (FLASH) has prepared the QuakeSmart Community Resilience Program for informational and educational purposes
The Federal Alliance for Safe Homes, Inc. (FLASH) has prepared the QuakeSmart Community Resilience Program for informational and educational purposes only. Although the information and recommendations
More information(1) Minami Nagamachi and Naka Nagamachi viaducts between Shiraishi Zao and Sendai Stations on the Tohoku Shinkansen line
Report by the First Joint Survey Team of the JSCE Concrete and Structural Engineering Committees on the damage caused by the Great East Japan Earthquake April 5, 2011 (First Report) 1. Survey team members
More informationImportant Points: Timing: Timing Evaluation Methodology Example Immediate First announcement of building damage
3.3. Evaluation of Building Foundation Damage Basic Terminology: Damage: Destruction, deformation, inclination and settlement of a building foundation caused by an earthquake. Damage grade: Degree of danger
More informationBasement & Foundation Damage
Basement & Foundation Damage Please note-this presentation is only intended to be used as a basic educational tool and is by no means all encompassing. Each property should be treated on a case by case
More informationPrepared For San Francisco Community College District 33 Gough Street San Francisco, California 94103. Prepared By
Project Structural Conditions Survey and Seismic Vulnerability Assessment For SFCC Civic Center Campus 750 Eddy Street San Francisco, California 94109 Prepared For San Francisco Community College District
More informationSODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST
SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST SODA SPRINGS HIGH SCHOOL REPAIRS AND UPGRADES SITE Construction Estimate = $100,000
More informationMiss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,
Volume, Special Issue, ICSTSD Behaviour of Steel Bracing as a Global Retrofitting Technique Miss S. S. Nibhorkar M. E (Structure) Scholar, Civil Engineering Department, G. H. Raisoni College of Engineering
More informationDRAPER ELEMENTARY SCHOOL
INITIAL YEAR BUILT 1953 BUILDING AREA 54,000 SF CURRENT PROGRAM CAPACITY 250 ENROLLMENT 2008 84 WARD 8 PROPOSED PROGRAM CAPACITY 325 Site Plan DRAPER - 1 PROPOSED PROGRAM PROFILE GRADE CONFIGURATION PK-5
More informationPost Earthquake Quick Damage Inspection of Buildings in Nepal
Post Earthquake Quick Damage Inspection of Buildings in Nepal Collaborative Research and Development (R&D) Project for Disaster Mitigation in Earthquake Prone Areas in Asia (Sep 27, 2007) Presented By
More informationArchitectural Condition Survey
Architectural Condition Survey Santa Fe Railroad / AMTRAK Depot, Lawrence. Kansas for the City of Lawrence, 2002 Survey: (student) PI: William Carswell, Associate Dean, School of Architecture, University
More informationDESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT
DESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT Troy Oliver 1, Mark Rea 2 ABSTRACT: This paper provides an overview of the work undertaken in the design of multiple buildings for one of
More informationPrelease Schedule of Condition and Want of Repairs at Milton Keynes for May
Prelease Schedule of Condition and Want of Repairs at Milton Keynes for May Instruction To carry out Inspection of the Industrial Unit, to identify areas of repair to the Unit at commencement of the Lease.
More informationENTRY FORM. DVASE 2013 Excellence in Structural Engineering Awards Program
ENTRY FORM DVASE 2013 Excellence in Structural Engineering Awards Program PROJECT CATEGORY (check one): Buildings under $2M Buildings Over $100M Buildings $2M-$10M Other Structures Under $5M Buildings
More informationBUNKER HILL ELEMENTARY SCHOOL
INITIAL YEAR BUILT 1970 BUILDING AREA 98,200 SF CURRENT PROGRAM CAPACITY 332 ENROLLMENT 2008 387 WARD 5 PROPOSED PROGRAM CAPACITY 750 Site Plan BUNKER HILL - 1 PROPOSED PROGRAM PROFILE GRADE CONFIGURATION
More informationThis report presents the findings and recommendations of the assessment of energy use and
This report presents the findings and recommendations of the assessment of energy use and environmental stewardship of Arlington Street Church, Boston, MA. As stewards of the earth it is important that
More informationRepairs, Remodeling, Additions, and Retrofitting
Repairs, Remodeling, Additions, and Retrofitting HOME BUILDER S GUIDE TO COASTAL CONSTRUCTION FEMA 499/August 2005 Technical Fact Sheet No. 30 Purpose: To outline National Flood Insurance Program (NFIP)
More informationCLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.
CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front
More informationBROWNSVILLE STRUCTURES STUDY. July 2012. Prepared by. LDA ARCHITECTS 33 Terminal Way, Suite 317 Pittsburgh, Pennsylvania 15219 1208
BROWNSVILLE STRUCTURES STUDY July 2012 Prepared by LDA ARCHITECTS 33 Terminal Way, Suite 317 Pittsburgh, Pennsylvania 15219 1208 TABLE OF CONTENTS I. SUMMARY OF BUILDING ANALYSIS.. 1 II. INDIVIDUAL BUILDING
More informationPage & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
More informationPROFESSIONAL ENGINEERING INSPECTIONS, INC.
PROFESSIONAL ENGINEERING INSPECTIONS, INC. P. O. BOX 271492 HOUSTON, TEXAS 77277 Registered Engineering Firm #1503 http://www.profengineering.com (713) 664-1264 July 8, 2004 Mr. Simple Samson 2831 Octoberfest
More informationLeaky Homes Financial Assistance Package (FAP) Repair plan example
LEAKY HOMES FINANCIAL ASSISTANCE PACKAGE FACT SHEET Repair Plan Example - June 2014 Page 1 Leaky Homes Financial Assistance Package (FAP) Repair plan example Introduction This repair plan example is intended
More informationGuernsey s Structural Engineering Experience
Guernsey s Structural Engineering Experience Foundation Settlement Issues: Trinity Valley Electric Cooperative, Kaufman, TX: Analyzed their headquarters facility for issues with soil movement that was
More informationPersonal Information. Professional Education
Jose Antonio Flores Ruiz Structural Engineer Personal Information Telephone + (52) 1 322 108 41 12 e mail Place of birth Toluca, Mexico Date of birth October 6th 1978 Marital Status Married Nationality
More informationJames M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
More informationSeismic Isolation Retrofitting of Japanese Wooden Buildings
Seismic Isolation Retrofitting of Japanese Wooden Buildings Summary Junko Suga Building Design Department Takenaka Corporation, Osaka Main Office Osaka, Japan Hiroyuki Ueda Building Design Department Takenaka
More informationSEISMIC CAPACITY OF EXISTING RC SCHOOL BUILDINGS IN OTA CITY, TOKYO, JAPAN
SEISMIC CAPACITY OF EXISTING RC SCHOOL BUILDINGS IN OTA CITY, TOKYO, JAPAN Toshio OHBA, Shigeru TAKADA, Yoshiaki NAKANO, Hideo KIMURA 4, Yoshimasa OWADA 5 And Tsuneo OKADA 6 SUMMARY The 995 Hyogoken-nambu
More informationFixed Access Ladders. Table of Contents. 1. Legislative Requirements
Fixed Access Ladders Engineering Data Sheet 2-04 Revised: January 1997 Table of Contents 1. Legislative Requirements 2. General 3. Rungs 4. Side Rails 5. Safety Cages 6. Attachment & Anchoring 7. Platforms
More informationAcumen Enterprises, Inc.
Hourly rates Discount w/o Rebate Electrician $78.00 10% $70.20 $70.73 HVAC Technician $78.00 10% $70.20 $70.73 Insulator $42.00 10% $37.80 $38.08 Sheet Metal Worker $74.00 10% $66.60 $67.10 Plumber/Pipefitter
More informationBuilding Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
More informationProtecting YOUR NEW HOME FROM Wind Damage
Protecting YOUR NEW HOME FROM Wind Damage Blueprint for Safety... A Blueprint for Life When severe weather threatens, protecting life and property automatically becomes top priority for millions of Florida
More informationSuperform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
More informationHow To Protect Your Home Or Business From Hurricane Damage
Introduction Wind can tear the roofs from buildings, rip siding from exterior walls, and throw debris through windows. Falling trees can crush roofs and walls. Of course, hurricanes and tornadoes generate
More informationThe Collapse of Building 7 by Arthur Scheuerman December 8, 06
The Collapse of Building 7 by Arthur Scheuerman December 8, 06 WTC s Building 7 was a 47-story office building completed in 1987 by Silverstein Properties on land owned by the Port Authority. It was built
More informationEASY WAYS TO QUAKE SAFE YOUR HOME
EASY WAYS TO QUAKE SAFE YOUR HOME A handy guide to help you prevent earthquake damage to your home AFTER AN EARTHQUAKE YOUR HOME MAY BE A MESS, YOU COULD BE WITHOUT A WATER SUPPLY, AND SOMEONE IN YOUR
More informationTHE DESIGN OF BUILDING SERVICES FOR EARTHQUAKE RESISTANCE
THE DESIGN OF BUILDING SERVICES FOR EARTHQUAKE RESISTANCE Graeme J BEATTIE 1 SUMMARY The design of seismic restraints for building services equipment is often a matter that is overlooked because there
More informationSEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE
International Journal of Advanced Research in Biology Engineering Science and Technology (IJARBEST) Vol., Issue, April 1 SEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE M.R.NAVANEETHA KRISHNAN 1,
More informationWEBSTER ELEMENTARY SCHOOL New Rochelle, New York Evaluation of Collapsed Ceiling Room 204
WEBSTER ELEMENTARY SCHOOL New Rochelle, New York Evaluation of Collapsed Ceiling Room 204 Structural Inspection Report Client: CSArch Architecture Engineering Construction Management 19 Front Street, Newburgh,
More informationTENANT AND LANDLORD REPAIR RESPONSIBILITIES
TENANT AND LANDLORD REPAIR RESPONSIBILITIES REPAIR LANDLORD TENANT Notifying Repairs Any alteration or improvement you have carried out to the property Permission required Water damage caused by push-on
More informationRetrofitting of Existing RCC Buildings by Method of Jacketing
Retrofitting of Existing RCC Buildings by Method of Jacketing BHAVAR DADASAHEB O. Assistant Professor, Sandip Institute of Engineering & Managemnt, At Post Mahiravani, Trimbak Road, Nashik. Maharashtra
More informationINSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT
VISCMA 412/August 2014 INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT August 2014 Developed originally by the Vibration Isolation and Seismic Control Manufacturers Association under a cooperative
More informationSafety Inspections and Sample Safety Inspection Checklists
Safety Inspections and Sample Safety Inspection Checklists Even if safety inspections were not strongly recommended, they are an excellent way for the department to reference the commitment to safe work
More informationIntroduction. How Great Is Your Risk of Earthquake Damage?
Introduction After an earthquake hits, it s too late to protect your home or business from damage. But you can limit future earthquake damage. Sometimes, a little time and a few dollars are all you need.
More informationWASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
More informationBasement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
More informationChapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
More information2. What building projects are exempted? (permit not required)
BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and
More information