An Innovative, portable MCA based on Digital Signal Processing. R.D. Bingham, R.M. Keyser, T.R. Twomey



Similar documents
Performance of a portable, Digital-Signal-Processing MCA with Safeguards Germanium Detectors

MAESTRO 7. Multichannel Analyzer (MCA) Application Software

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

Characteristics of an Integrated Germanium Detector Based Gamma-Ray Spectrometer for Monitoring Systems

GammaVision 8. Gamma Spectroscopy Software. Compatible, Efficient, and Defendable Results for Gamma Spectroscopy Applications.

IDM-200 -V. Interchangeable HPGe Detector Module (IDM) for Systems Integrators

ORTEC. Micro-trans-SPEC. Ultra-Light, Battery-Powered, Portable, LN 2 -Free, HPGe Gamma Spectrometer

Reconfigurable System-on-Chip Design


Networks and Connections in the Counting Room

Automated Laboratory Quality Assurance Program: Using the ORTEC GammaVision -32 Software

AlphaVision. Alpha Spectrometry Management Software

LLRF. Digital RF Stabilization System

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Global Value 7. Productivity Suite for GammaVision. Optimizing Gamma Spectrometry Processes through Secure Data Management and Measurement Automation.

S2000 Spectrometer Data Sheet

A Comparison of an HPGe-based and NaI-based Radionuclide Identifier (RID) for Radioactive Materials

Stuart Gillen. Principal Marketing Manger. National Instruments ni.com

REAL-TIME DUST AND AEROSOL MONITORING

Sigma Control PC INSIDE. 97 psi 187 F R on load

RF Measurements Using a Modular Digitizer

Temperature & Humidity SMS Alert Controller

Scalar Network Analyzer

Description: Multiparameter System (4 or 8 channels)

ORTEC DET-SW-UPG. Latest Software Features. Ease of Use. Source Location with the Detective V3 Software

POCKET SCOPE 2. The idea 2. Design criteria 3

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

Frequency selective monitoring and logging of environmental electromagnetic fields

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Measurement solutions for nuclear safety and security. software customization services. Nuclear MeasureMeNts BusiNess unit of areva

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Electronics GRETINA Project

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

WIRELESS INSTRUMENTATION TECHNOLOGY

RADIATION DETECTION & ANALYSIS SYSTEMS FOR WATER

Security & Chip Card ICs SLE 44R35S / Mifare

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Measuring electric and magnetic fields

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

Digital Single Axis Controller

EVAL-UFDC-1/UFDC-1M-16

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

ACR880 GPRS Portable Smart Card Terminal

ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Appendix 5 Overview of requirements in English

thyroid uptake systems

Transmitter Interface Program

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

NIM High Voltage Power Supplies

Hand-held thermometer Model CTH7000

Simple SDR Receiver. Looking for some hardware to learn about SDR? This project may be just what you need to explore this hot topic!

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

A Digital Spectrometer Approach to Obtaining Multiple Time-Resolved Gamma-Ray. Spectra for Pulsed Spectroscopy. W. K. Warburton a

Cronos -1 Gamma Object / Tool Monitors

ELEC 5260/6260/6266 Embedded Computing Systems

Lecture N -1- PHYS Microcontrollers

How To Use An Ionsonic Microscope

Optimizing VCO PLL Evaluations & PLL Synthesizer Designs

ATLAS Tile Calorimeter Readout Electronics Upgrade Program for the High Luminosity LHC

Nuclear applications at the Hellenic Centre for Marine Research (HCMR): Radioactivity in the marine environment

Captus 3000 Thyroid Uptake And Well System

Wahl C50 Calibrator FEATURES

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

DC Electronic Loads 8500 series

Remote RadEye Product Family

Fingerprint Based Biometric Attendance System

Open Architecture Design for GPS Applications Yves Théroux, BAE Systems Canada

Duct Humidity Transmitter

Rapid Audio Prototyping

STM32L. Ultra-low-power Cortex -M3 devices

High Power Programmable DC Power Supplies PVS Series

Embest DSO2300 USB Oscilloscope

Multi-Range Programmable DC Power Supplies 9115 Series

W a d i a D i g i t a l

Flexible Counter Series in DIN size 24 x 48 mm

T0118 T2118 T3118. Instruction Manual

Dual Laser InfraRed (IR) Thermometer

Chlorophyll Content Meter. CCM-200 plus

PowerGem Pro Uninterruptible Power Supply

Everything you need for protection scheme testing

Arun Veeramani. Principal Marketing Manger. National Instruments. ni.com

Design And Implementation Of Bank Locker Security System Based On Fingerprint Sensing Circuit And RFID Reader

USB-500 Series Low-Cost Data Loggers and Accessories

Application Note. Monitoring the Release of Radioactive Noble Gases Through the Stack of a Nuclear Power Plant (NPP): Stack Monitor System

Field Service Application

Web Streamed SDR s in Service at GB2RHQ Hack Green Bunker

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

DS1104 R&D Controller Board

Kit Highlights and Key Features

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

MH - Gesellschaft für Hardware/Software mbh

Thyroid Uptake Systems The Ultimate... User Friendly... Intuitive Captus 3000 Thyroid Uptake And Well System

Multi-Range Programmable DC Power Supplies 9115 Series

Network analyzer and spectrum analyzer two in one

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

LEVERAGING FPGA AND CPLD DIGITAL LOGIC TO IMPLEMENT ANALOG TO DIGITAL CONVERTERS

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Transcription:

An Innovative, portable MCA based on Digital Signal Processing R.D. Bingham, R.M. Keyser, T.R. Twomey ORTEC, PerkinElmer Instruments, Inc Oak Ridge TN 37831-0895 USA Abstract Digital Signal Processing is being applied more and more to measurements in the field of nuclear spectroscopy. In all applications it offers greater stability, improved resolution and greater throughput at high count rates. All of these improve the quality of the spectrum and the analysis results. Recently, this technology has been incorporated in portable instruments. A new portable instrument will be described which offers all the digital benefits of DSP and adds features for additional functionality: a local display and keypad, significantly reducing the need for a PC in many field applications and an associated intelligent HPGe detector system, providing overall system state of health and allowing for the authentication of the entire system and its data. Performance data using a Safeguards-type HPGe detector are presented. Introduction The first, mains-powered, fully integrated highresolution gamma-ray spectrometer (DSPEC) was introduced commercially several years ago. It has been used extensively in difficult measurement situations such as those encountered in nuclear safeguards and nondestructive assay 1. For portable spectroscopy applications the LANL-developed Davidson PMCA 2 with onboard cassette tape storage, local display and limited smart capabilities has been the instrument of choice for safeguards inspectors across the world for routine measurements such as uranium enrichment. The recent-generation of small portable MCAs, having no on-board bulk storage, display, keypad or computing power are blind peripherals, and have required the use of an associated small computer. Whereas this approach is perfectly acceptable in a laboratory situation, where a desk top computer can provide excellent display, storage and analysis capabilities at low cost, in a portable instrument, the necessity to always carry a computer can be a strong disadvantage. The new instrument reported here, with the trade-name digidart TM is being produced by PerkinElmer Instruments (ORTEC). It combines the high performance attributes of the digital signal processing in a small, batteryoperated package. For the first time since the days of the PMCA, the instrument includes an on-board display and the ability to store multiple spectra without the need for an accompanying PC. In addition, digidart introduces new SMART-1 HPGe detector technology, which can monitor the system state of health and provide authentication of spectral data. Circuit Description The digidart hardware is shown schematically in Figure 1. The high voltage supply and detector monitoring are provided in a separate detector interface module (DIM). Following the front-end amplifier, a 14-bit, 10 MHz flash ADC samples the incoming pulse stream and converts each pulse into a string of digital numbers. This is then filtered directly by a proprietary digital filter algorithm, implemented in a field-programmable gate array

(FPGA). This also provides the functions of digital baseline restorer, fine gain, peak qualification, conversion gain, digital upper and lower discriminators, and spectrum stabilization. System control, keypad communications, spectral display and control of USB and/or RS232 communication is provided by the microprocessor. The microprocessor also controls the detector high voltage and provides the detector monitoring function. The battery-backed histogram memory provides up to 16000 channels of non-volatile data storage with optional 32000 channels. A flash memory provides for non-volatile storage of multiple spectra. Over 600 512-channel spectra may be stored. A digital version of the Gedcke-Hale live-time clock is implemented. circuitry is built into the instrument. Any 12V DC external supply will trickle charge the battery and operate the instrument. The battery may be replaced without loss of spectral data and the instrument restarted in seconds, to extend the operation beyond 12 hours. This single battery is more reliable and weighs less than the two battery hot swap design, where two batteries are attached but only one is in use at a time. Physical The instrument is packaged in an impactresistant, ABS plastic enclosure, with rubberized overmolding, as shown in Figure 2. The outside overmold is a shock-absorbing, easy grip, stay clean coating. The display and sealed membrane keypad are recessed to protect them if the instrument is dropped. The easy-to-grip enclosure will fit in a box 20 cm x 12.7 cm x 7.7 cm and the weight including battery is <850 gm. Figure 1 Portable MCA Schematic Block Diagram The digital trapezoidal filter provides 99 risetime and 16 flat top choices in the ranges 0.8 S to 20 S and 0.5 S to 2 S respectively. This wider range of choices allows precise optimization of detector settings. A digital Automatic Pole Zero circuit 3 is provided, along with an optimize function which automatically optimizes the flat top tilt as well as Pole Zero across the range of rise time/flat top combinations. Battery and Power Management The instrument is powered by a single Sony NP-F960 camcorder battery, which will operate for up to 12 hours including supplying the detector power. The battery management Figure 2 The portable MCA in hand-held use HPGe Detector Support SMART-1 technology improves the integrity of data and the chain of custody integrity as well

as overall detector management practice. A SMART-1 detector is intelligent. It is capable of monitoring and reporting back state of health (SOH) information. Moreover, it can be queried for its own identification serial number 4 and can have authentication codes written to it and later read from it to ensure authenticity of data. Because digidart is part of the CONNECTIONS architecture, these operations may be carried out remotely over a network, which is of interest for unattended monitoring applications. During data acquisition, the SMART-1 detector monitors all of its own vital functions; preamplifier supply voltages, detector temperature, high voltage, overload state, HV shutdown state, serial number, and authentication code. Should any of the monitored functions fall outside a specified range of values (even if they subsequently return to normal), the condition is registered. At the end of the acquisition, the digidart checks the SOH and will display a warning message. The SOH status is saved with the spectral data for QA purposes. Userdeveloped packages may query SOH register in the digidart for QA purposes. At the start of the acquisition, the SMART-1 detector is queried for its serial number. A random number (authentication code) is written to the SMART-1 detector by the digidart. At the end of the acquisition, both numbers are read from the SMART-1 detector and compared to the original values. An exact match assures data integrity. A separate HV module, known as a DIM (detector interface module), is available for support of non-smart detectors. Display and Built-in Analysis functions The 240 x 160 pixel backlit LCD (Figure 3) provides live spectral display, status information and analysis results. It features full display, display of multiple ROIs and Zoom modes. A Status line provides parameter display; with the user able to choose any two from: cursor energy, location, live time, live time remaining, real time remaining, battery life remaining, Count rate, Count rate in ROI, or counts. A real time Peak Information function reports centroid, FWHM, Net and Gross area for the ROI where the cursor is positioned. Figure 3 The portable MCA spectral display A two-point energy calibration of channel and FWHM can be done at any time from the keypad. The user can define from 1 to 9 regions for the Nuclide activity display. The activity with uncertainty is calculated and reported in real time. Multiple acquisition presets are provided: live time, real time, integral peak count, peak area, MDA and uncertainty. Associated Software The unit is supported by the ORTEC standard MAESTRO TM MCA Emulator, which has been extended to support easy set up of all the instrument functions via the USB hardware interface. The philosophy is that it is easier, in general to set the instrument up for use back at base using a large-screen PC, but that if necessary, settings changes may be made in the field, with no PC present. The settings can be protected by password, so that they can not be inadvertently changed. Two levels of passwords are used to allow some functions to be changed and not others. If a password is

set, the password must be entered when the digidart is powered on. The instrument is compatible with all of the ORTEC analysis packages, including versions of MGA++ and PC/FRAM Isotopic ratio packages, and products for the ISOTOPIC analysis of soils and containers as well as general purpose gamma-analysis packages. To aid developers, programmer s toolkits are available. Comparative performance data In a recent LANL evaluation 4, the latest ORTEC digital laboratory spectrometer, the DSPEC Plus was evaluated and considered to be highly recommended. It may therefore be considered as a suitable benchmark for comparison purposes. The new portable MCA was compared to the DSPEC Plus under conditions which are similar to those pertaining to many safeguards measurements. The data were taken with a 500mm 2 planar geometry detector. Figure 4 shows the 122 kev resolution at low count rate as a function of filter rise time. It shows the familiar degradation in resolution as the filter rise time gets very short. Figure 5 System Throughput, comparative data Figure 6 shows that in terms of 122 kev resolution, once again, the two systems are very close. Figure 6 Comparative resolution data Figure 7 shows that the portable instrument exhibits slightly superior peak count-rate stability to the DSPEC plus system. Figure 4 Portable MCA 122 kev resolution as a function of filter rise time Figure 5 shows comparative system throughput at 2.2 S filter rise time. The performance from the portable instrument is very similar to that of the benchmark DSPEC plus; if anything it is slightly superior. Figure 7 Comparative peak count rate stability data Conclusion A new and innovative digital high performance portable MCA has been developed and tested.

A new and innovative digital high performance portable MCA has been developed and tested. It has been shown to provide performance at least equivalent to the best laboratory grade, digital spectrometer. Its package and display provide superior ergonomic features to other portable spectrometers and its built-in display, spectral storage and analysis capabilities extend the usefulness of handheld MCAs. Refs: 1. D.T. Vo, P.A. Russo and T.E. Sampson, Comparisons between Digital GAMMA-Ray spectrometer (DSPEC) and Standard Nuclear Instrumentation Methods (NIM) Systems, Los Alamos report LA-13393- MS (October 1997) 2. J.K. Halbig and S. Klosterbuer The Mini-MCA: An Intelligent Inspection Instrument. Presented at the International Symposium on Recent Advances in Nuclear Material Safeguards, Vienna Austria 1982. 3. Twomey, T. R., Bingham, R. D., Keyser, R. M. Authentication and data quality monitoring with Safeguards HPGe detector systems, to be published 4. D.T Vo, Comparions of the DSPEC and DSPEC plus Spectrometer Systems, Los Alamos report LA- 13671-MS, 1999