in.k600 TechBook Giving full control to wet fingers! series of full-function keypads with streamlined interfaces

Similar documents
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Operation Guide 3M-22

Water Priming Mode Purge air from plumbing system. How do I solve ER-3 WATER PRIME: TIPS ON FILLING SPA IMPORTANT NOTE WARNING

EK908FHL - Thermostat for floor heating

SWIMMING POOL HEAT PUMP Owners Manual

STERILIZERS, LABORATORY DRYING OVENS

Drayton Digistat +2RF/+3RF

TechBook. Y seriestm whatever the spa, this is your control system. Total Flexibility Total Compatibility Total Satisfaction

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more.

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Microwave Meter. Instruction Manual

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

INSTALLATION AND OPERATING INSTRUCTIONS

LCD5500Z / PKP-LCD v3.x Installation Instructions

Powers Controls TH 192 S Single Temperature Room Thermostat

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Digital Photo Picture Frame. Operation Manual

Threaded Inline Air Heaters

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

4-Channel Thermometer / Datalogger

TIG INVERTER INSTRUCTION MANUAL

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

FTXS. Wall Mount Heat Pump or Cooling Only

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

CARING FOR YOUR WATER HEATER

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

NEC SIP Conference Max Conferencing Phone USER S GUIDE

Manual for Fire Suppression & Methane Detection System

DAB+ / FM Tuner Model: TU-201

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Digital inductive conductivity transmitter

Failure code manual. content

Use and Care Manual. Model CPA12KH AIR CONDITIONER

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

User Manual. Video Doorphone CDV-1020AQ

Online UPS. PowerWalker VFI 1000R/1U

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

My home Mobile phone application

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Thermo Top - Troubleshooting Tree

Greenline Industrial Monitors IMD-C Series. User Manual

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

How To Use A Power Supply Unit (Upu)

Mode Switch. Fan Switch Menu button Program button

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

Owner s Manual

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

INSTRUCTION FOR THE USER

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

EPSON USB/Parallel Adapter User s Guide

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

INSTALLER S & OWNER S MANUAL

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

EBDSPIR-PRM, EBDSPIR-PRM-IP

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CE6500 Energy Recovery Ventilator

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

Installation, operation and maintenance manual TX 35A

FT-100 Fire Training Fog Machine User Manual English

HOOK-3x DSI. Operation manual. lowrance.com ENGLISH. HOOK-3x DSI

Mold Alert... Operation Manual P0270

User s Manual AURORA 1.2K/2.2K

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

Smart Touch. Owners Manual. By INNOVATIVE POOL PRODUCTS LLC. For more information look us up on the web at

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Installation & Maintenance Instructions Joystick- single Joystick - double Touch panel Wireless remote control

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

LED MOTION ACTIVATED FLOOD LIGHT

Installation and Operation Back-UPS 1250, 1300, 1500

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

SMD Rework Station TABLE OF CONTENTS

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Thermistor Thermometer MODEL NO

Installation Instructions

SunMaxx Solar Filling Station Operating Instructions

PORTABLE AIR CONDITIONER

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

IPTV STB QUICK GUIDE. Detailed user manual download from

Nokia Bluetooth Headset BH-102. Issue 1

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

SMARTOUCH DIGITAL. Series 1000 & 2000 USER & PROGRAMMING MANUAL

TC-9102 Series Surface Mount Temperature Controllers

WildFire EVO For Xbox 360

Transcription:

in.k600 series of full-function keypads with streamlined interfaces TechBook Giving full control to wet fingers!

in.k600 table of contents Table of contents overview... 3 warning...4 function description... 5 icon description... 7 installation - low profile...10 - drilling templates...11 connections...12 functions...13 specifications... 18 1

in.k600 overview in.k600 Advance series of full-function keypads that gives complete control to wet fingers! With its stunning design, Aeware s in.k600 series of advanced keypads are in.xm s ultimate user interface. They feature a low profile with a large LCD displays, streamlined interfaces that let users easily control all in.xm functions and programming directly from spa side, creating a true and unique Aeware user experience directly from spa side. 3

warning in.k600 WARNINGS: Before installing or connecting the unit, please read the following. FAILURE TO COMPLY WITH THE FOLLOWING WARNINGS MAY SIGNIFICANTLY SHORTEN THE PRODUCT S LIFE TIME, AND LEAD TO FAILURES AS WELL AS HAZARDOUS CONDITIONS*. COMMON SENSE MUST ALWAYS PREVAIL WHEN EVALUATING THE INSTALLATION AND/OR USE OF ANY ELECTRONIC CONTROL IN A FINAL APPLICATION. The maximum ambient conditions this PRODUCT is subjected to (temperature, humidity, etc.) are not to be exceeded. This PRODUCT must be installed by qualified personnel. Only qualified personnel are to service this PRODUCT. There are no user serviceable parts inside. The gasket on the back of the unit will prevent water infiltration inside, behind the mounted surface. If the gasket is damaged, the user must seal the back of the unit with silicone to avoid any leakage behind the mounted surface. * HAZARDOUS CONDITION: A condition that is potentially damaging and/or dangerous to its operator or surroundings. This includes, but is not limited to: fire, flooding or other water damage, dielectric breakdowns (presence of high voltage), etc. This PRODUCT is only compatible with Aeware s in.pac line of products. This PRODUCT should be installed on a clean flat surface. 4

in.k600 function description "Light" Key "Ok" Key "Plus" Key "Program" Key "Right" Key "Pump" Keys "Economy Mode" Key "Left" Key "Minus" Key "On/Off" Key 5

function description in.k600 "Light" Key "Ok" Key "Plus" Key "Program" Key "Pump"/ "Right" Key "Pump" Keys "Pump"/ "Left" Key "Minus" Key "On/Off" Key 6

in.k600 icon description Light icon Pump icons Blower icon Time, temperature & message digits AM/PM ( F/ C) Set point icon Progress bar icon Service icon Program icon Heating icon Filtering icon Economy mode icon Smart winter mode icon 7

icon description in.k600 Icon Description Light icon The "Light" icon lights up when the light is on. The icon's number of rays is proportional to the light's intensity. Pumps icons The "Pump" indicator numbers light up and their icons become fast animated when pumps are in high speed, slower animated icons when pumps are in low speed. Blower icon The "Blower" indicator icon become animated when blower is on. Service icon A problem has been detected. Do not enter the water! Spa service is required. Smart winter mode icon The "SWM" icon automatically turns on when freeze protection is active.. It flashes while system purges the spa plumbing. Economy mode icon The "Economy" icon lights up when filter cycle is on Filter Cycle icon The "Filter Cycle" icon lights up when filter cycle is on. It flashes when filtering is suspended. 8

in.k600 icon description Icon description Heater icon The "Heater" icon lights up when the heater is on. Progress bar A visual indication of the time remaining before an equipment is turned off or before the end of the standby mode. Set Point icon The "Set Point" icon automatically turns on when set point setting menu is activated. (SP message on display). It flashes when: 1- there is a call for heat and heater has not started yet, 2- heater has just turned off and element is cooling down or 3 - if system is performing a check flow. Program icon The "Program" icon lights up when Programming. 9

installation in.k600 Installation in.k600 low profile Gasket with or without adhesive 7.250" 3.750" Optional wing nuts and spacers To install the in.k600 low profile, use the drilling template provided in this section. Determine the mounting location and stick the template on chosen location. The user must cut out a rectangular shape opening of 7.250" by 3.750" according to the template (see illustration). Clean the installation surface and peel the adhesive gasket from the back of the keypad. Insert keypad and align it correctly, then ensure it's properly glued by gently pressing evenly on the entire surface. 10

in.k600 driling template low profile 184.15 mm 7.250" 90.49 mm 3.563" 15.88 mm ø 0.625" TYP. 2X 180.98 mm 7.125" 95.25 mm 3.750" 92.08 mm 3.625" 47.63 mm 1.875" 4.76 mm R 0.188" TYP. 4x

connections in.k600 Connecting in.k600 keypad to in.xm 12

in.k600 functions On/Off key Pump 1 key Pump 2 key Depending on the spa manufacturer, this key may have different functions: On/Off, Standby mode or quick enable of the Economy mode. Standby Mode : Use On/Off key to pause all pumps*. Progress bar will display the remaining time before the system automatically exits Standby mode (user can also exit Standby mode at any time by pressing again on On/Off key). In order to warn the user, the spa light will flash for a few seconds before the exit of Standby mode and restart the pumps. The "Stby" message is also displayed during Standby mode. * Pump will stay turned on if there is a request for more heat. Press Pump 1 key to turn Pump 1 on at low speed. Press a second time to turn pump to high speed (with a dual-speed pump). A third time turns pump off. A built-in timer automatically turns pump off after 20 minutes, unless pump has been manually deactivated first. Press Pump 2 key to turn Pump 2 on at low speed. Press a second time to turn pump to high speed (with a dual-speed pump). A third time turns pump off. A built-in timer automatically turns pump off after 20 minutes, unless pump has been manually deactivated first. 13

functions in.k600 Pump 3/Blower key Light key +/- keys Program key Press Pump 3/Blower key to turn Pump 3/Blower on. Press a second time to turn pump off. A built-in timer automatically turns pump off after 20 minutes, unless pump has been manually deactivated first. Note: depending on spa manufacturer's requirements the number of outputs may vary. Press Light key to turn light on at high intensity. Subsequent presses change light intensity. A last press turns light off. A built-in timer automatically turns light off after 2 hours, unless it has been manually deactivated first. Use (+) or (-) key to set desired water temperature. The temperature setting will be displayed for 5 seconds to confirm your new selection. The "Set Point" icon indicates that the display shows the desired temperature, NOT the current water temperature! Use Program key to display time or enter Programming menu by pressing and holding key. In Programming mode,. the following parameters can be set: time, filter cycle's start time, duration and frequency, also, Economy mode's start time as well as its duration and finally the choice of temperature display unit. 14

in.k600 functions Setting the time Setting filter cycle start time Setting filter cycle duration Filter cycle frequency Enter Programming mode by holding Prog. key pressed down for 3 sec. The display will show the current time setting. Setting the hour: Use (+) or (-) key to change hour setting (AM/PM). To program the filter cycle, you must enter these parameters: the start time, duration and frequency. During a filter cycle, pumps run for one minute to purge the plumbing, then Pump 1 runs for the programmed number of hours. Press Prog. key a fourth time. The display will show Fdxx, with "xx" representing the duration in hours. Use (+) or (-) key to change setting. Press Prog. key a fifth time. The display will show FFxx, with "xx" representing the number of filter cycles per day (up to 4). Use (+) or (-) key to change setting. Setting the minutes: Press Prog. key a second time. Use (+) or (-) key to change. hour setting. Press Prog. key a third time. The display will show FSxx, with "xx" representing the starting hour. Use (+) or (-) key to change setting (0:00 h - 23:00h). 15

functions in.k600 Setting Economy mode Setting Economy start time Setting Economy duration The Economy mode allows you to lower the temperature set point of the spa by 20 F (11 C) during a certain period of the day. Press Prog. key a sixth time. Use (+) key to enable the economy mode, the display will show EP 1. Use (-) key to disable economy mode, the display will show EP 0. To program the Economy mode, you must enter two parameters: the start time and the duration. Press Prog. key a seventh time. The display will show ESxx, with "xx" representing the starting hour. Use (+) or (-) key to change setting (0:00 h - 23:00h). Press Prog. key an eighth time. The display will show Edxx, with "xx" representing the duration in hours. Use (+) or (-) key to change setting. If the Economy mode is not required the duration must be set to "0". If continuous activation of the Economy mode is required the duration must be set to "24". When in Economy mode, the Econ message is displayed. 16

in.k600 functions Setting temperature unit Water temperature regulation Cooldown Smart Winter Mode Water temperature can be displayed in either Fahrenheit ( F) or Celsius ( C). Press Prog. key an nineth time. The display will show either F or C. In a regulation cycle, the system first generates water flow through the heater housing and the plumbing, in order to ensure accurate water temperature readings as well as avoiding heater activation in dry conditions. While performing these tasks, the heater is not allowed to turn on and its icon flashes. The heater is not allowed also to come on throughout the cool down period of the heater element. Our Smart Winter Mode protects your system from the cold by turning pumps on several times a day to prevent water from freezing in pipes. Use (+) or (-) key to change setting. Press Prog. key a last time to go back to normal mode. After verifying pump activation and taking a water temperature reading if required, the system automatically turns the heater on to reach and maintain water temperature at Set Point. 17

specifications in.k600 General specifications: Environmentals: Storage temperature: Operating temperature: Humidity: 85 C (185 F) to -30 C (-22 F) 65 C (149 F) to -20 C (-68 F) up to 95% condensing Mechanical Specs: Weight: 0.4763 Kg (1.05 lbs) Dimensions (W x H x D): Front panel Low Profile: 8.726" x 4.227" x 0.200" Standars:.. IP ratings IPX6 Specifications and design are subject to change without prior notice. 18

100%

Advanced electronics! Water resistance! Printed in Canada 9919-100665 Rev. 12/10 2010 Groupe Gecko Alliance Inc. TM trade-marks of/marques de commerce de Groupe Gecko Alliance Inc. Gecko Alliance 450 des Canetons, Quebec City (QC) G2E 5W6 Canada, 1.800.78.GECKO 9225 Stellar Court, Corona, CA 92883 USA, 951.667.2000 www.geckoalliance.com