Predictive Maintenance



Similar documents
Predictive Maintenance in a Mission Critical Environment

SWITCHING STRATEGIES: MOVING TO CONDITION- BASED MAINTENANCE. By David Stevens, Technical Manager & Trainer, AVT Reliability

PdM Overview. Predictive Maintenance Services

ACCEPTANCE TESTING, COMMISSIONING & START UP PREDICTIVE & PREVENTATIVE ELECTRICAL TESTING SERVICES ENGINEERING SERVICES

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

AC-Synchronous Generator

Electrical Distribution Services for Mining and Metals Industries

WHAT IS INFRARED (IR) THERMOGRAPHY

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

Diesel Engine Driven Generators Page 1 of 6

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

Electrical Predictive and Preventative Maintenance

Engineering innovation

Who sets the rules for electrical testing and safety?

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

SKF Asset Management Services. Your trusted resource for life cycle support and sustainability of physical assets

A Practical Guide to Maximizing Machine Uptime

Proactive Asset Management with IIoT and Analytics

Understanding maintenance strategies

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

13 common causes of motor failure

uptimeplus.co.uk predictive maintenance strategy galileo Supported by

The Basics of Predictive / Preventive Maintenance

Statement Of Work. Data Center Thermography Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary

Increase Equipment Uptime Through Robust Enterprise Asset Management. For the Upstream, Midstream & Downstream Sectors of the Oil & Gas Industry

21 st Century Facilities

Use your troubleshooting superpowers for good Application Note

IMPLEMENTING A RELIABILITY CENTERED MAINTENANCE PROGRAM AT NASA'S KENNEDY SPACE CENTER

City Of Ottawa High Voltage Substation Inspection, Maintenance Rev July 17 and Testing, ROPEC Page 1

Appendix B Audit Forms for PdM Program Assessment

ABB PSPS Erich Steinmann; Generator control-2013

Information Needed for Effective Asset Management

Eaton s Electrical Services & Systems. Technical Training Safety Training

OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010

EVANS ENTErprises, Inc.

Asset Management 101

2012 Americas School of Mines

Specifying a Variable Frequency Drive s

Process Operators and Maintenance Staff Work Hand-in-hand with DCS-embedded Condition Monitoring

Equipment Performance Monitoring

Arc flash can kill. Arc flash can be considered as a short circuit through

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

Operations & Maintenance 201 Using online monitoring and predictive diagnostics to reduce maintenance costs

AC Electric Motors best practice

What s up with Arc Flash?

STATEMENT OF WORK FOR MAINTENANCE OF AIR CONDITIONERS

APPLICATIONS FOR MOTOR CURRENT SIGNATURE ANALYSIS

Nine Steps to Oil Analysis Success

The Costs and Risks Associated with Improper Service and Maintenance of Electrical Systems

Intelligent Vibration Monitoring

Comparison of CMS Preventive Maintenance Regulations

Vibration Analysis Survey Report

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Chapter 5 Types of Maintenance Programs

Acuren s Vision: To be a Trusted Partner by Providing Programs that clearly reduce our client s cost to operate.

HVAC System Optimization

Voltage Unbalance and Motors

Ultrasound Condition Monitoring

INSPECTION AND TESTING OF EMERGENCY GENERATORS

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

Better-performing Assets Make Companies

Solving VFD-sourced Bearing Current Problems in AC Motors.

6 Reasons Why Outsourcing Equipment Maintenance Is Your Best Hedge In A Down Economy

Reliability. The Essentials of Eliminating Downtime of your Electric Motor. Asset Management? Or, Maintenance Management, Re-branded?

Asset management systems increase reliability and efficiency

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Electrical Distribution Services from Schneider Electric

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.

Maximizing return on plant assets

Technical Electrical Field Service Support. Knowledge + Experience = Power. Field Service

Power Quality. Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost

SEE IT. SAVE IT. SHARE IT. Preventive maintenance simplified with Fluke Connect Assets.

Replacement Breakers & Retrofit Products

Vilter motor starter solutions The NEW industry standard in motor starter packages

Brochure. ABB Customer Training Program for Motors and Generators Sharing knowledge and creating value

SIEMENS Transmission and Distribution

Understanding Arc Flash

Electrical Safety in the Workplace

QAD EAM - Maintenance Demonstration Guide. August 4, 2015 EAM 2015

Features. Emerson Solutions for Abnormal Situations

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

How to Build a Safe and Effective Electrical Maintenance Program

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

PMG vs. DFIG the big generator technology debate

FaciliWorks. Desktop CMMS Software. Making Maintenance Manageable

Monitoring the Operation of Wind Turbines Alex Robertson, Vestas Northern Europe

control manual Optimal maintenance decisions for asset managers by andrew k.s. jardine and neil montgomery 44 Industrial Engineer

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

ARC FLASH HAZARD OVERVIEW. Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc.

TROUBLESHOOTING PRELIMINARY

Enhance Production in 6 Steps Using Preventive Maintenance

Evaluating Water-Damaged Electrical Equipment

Pump Maintenance - Repair

Transcription:

PART ONE of a predictive maintenance series Predictive Maintenance Overview Predictive maintenance programs come in all shapes and sizes, depending on a facility s size, equipment, regulations, and productivity goals. This overview: Outlines some of the most common predictive maintenance methods Explains how to determine the potential cost savings of maintenance improvements Walks through a predictive maintenance process Lists the relevant standards For more specific cost calculations or measurement guidelines, reference the other application notes in this series. For more information on Fluke Predictive Maintenance Products and Services go to www.fluke.com/pdm

Maintenance methods Reactive Maintenance Run-to-failure approach: letting a system run until something breaks. Maximum cost in terms of revenue lost and equipment replacement. Preventive Maintenance (PM) Maintenance repairs performed on a regular schedule to minimize component degradation and extend the life of equipment. Preventive maintenance is performed after a set amount of elapsed calendar time or machine run time, regardless of whether the repair is needed. While more cost-effective than reactive maintenance, preventive maintenance still requires substantial human resources and replacement parts inventories. Predictive Maintenance (PdM) Tracking key indicators over time to predict when equipment needs repair. Predictive maintenance programs measure equipment on a regular basis, track the measurements over time, and take corrective action when measurements are about to go outside the equipment operating limits. Repairing equipment as-needed requires fewer man-hours and parts than preventive maintenance. However, tracking the measurements requires new tools, training, and software to collect and analyze the data and predict repair cycles. Reliability-Centered Maintenance (RCM) Prioritizing maintenance efforts based on equipment s importance to operations, its downtime cost in revenue and customer loss, its impact on safety, and its cost of repair. Reliability maintenance depends on the same measurements used in predictive maintenance, but saves additional maintenance resources by spending less effort on less important machinery. RCM also requires more training and software than PdM. Maintenance software: CMMS and AMS Most facilities practicing predictive maintenance purchase or develop a specialized database, commonly referred to as either an asset management system (AMS) or a computer managed maintenance system (CMMS). To track trends, a database system should be able to store: List of critical equipment Maintenance and measurement procedures for each type of equipment Maintenance schedule A history for each measurement Limits for each measurement (maintenance alarm trigger) Many systems also track warranty status, depreciation records and purchasing information, and can generate works orders, manage schedules, and track employee training histories and related skills.

Cost analysis There is plenty of evidence that careful, well-planned maintenance prolongs the life of equipment and prevents costly downtime. Insurance data referenced in NFPA 70B indicates that roughly half of the damages associated with electrical failures alone could be prevented by regular maintenance. To determine the investments to make in your system, you need to know two things: the probability of a failure and the cost of the failure. By multiplying these two figures, you can estimate a level of investment in your infrastructure, including maintenance. Probability of failure The IEEE 493 standard contains useful data on the failure rates of electrical equipment and techniques for determining the probability of downtime for any given load. For each facility, also incorporate operator knowledge, maintenance history and manufacturers specifications, as well as the failure analysis provided by PdM software tools. FMEA: Failure Modes and Effects Analysis Used in reliability-centered maintenance, FMEA is a method for analyzing how a system can fail, the impact of the failure, the frequency of failure and the probability of the failure being hidden. The FMEA method assigns risk priority to assemblies based on: Severity of impact Probability of occurrence Probability that a failure will remain hidden For example, for a critical three-phase motor, overcurrent trip due to phase loss would be failure mode. The probability of phase loss remaining hidden can be high, since the motor may continue to run. To bring hidden failures to the surface, take measurements that are closely correlated to the failure mode. In the motor example, current monitoring will quickly uncover loss of a phase on a three-phase motor. Cost of failure Unplanned downtime cost variables: Lost revenue during downtime especially critical if the plant is running at or near capacity, or in highly competitive markets. Measured in dollars per hour. Lost revenue due to loss of customer confidence how many customers will leave you. Replacement cost of damaged electrical or production equipment Repair costs, especially labor Cost of scrap Cost to clean and restart production Insurance premium reductions To build a case for preventive maintenance, estimate the cost of failure and compare that to the cost of a maintenance program. 1. Calculate net income per hour of output for your production line or other critical process. Sample = $5,000/hr. 2. Calculate average downtime for each equipment failure and number of events per year. Sample = Failed motor repair requires avg 5 hrs; 2 motors fail annually. 3. Multiply the results of #1 by both values in #2. Sample: $5,000 x 5 x 2 = $50,000 in lost revenue. 4. Estimate labor and equipment repair cost. Sample: $50/hr x 5/motor + $3,000/motor = $6,500. 5. Add #3 and #4. This is your avoidable annual cost in lost revenue + repair. Sample: $50,000 + $6,500 = $61,500. 6. Repeat cost calculation based on planned downtown where no revenue loss is incurred. Sample: $50/hr x 5/motor + $3,000 for 1 new motor + $1,500 for 1 repaired motor = $5,000. Utilizing scheduled downtime, the maintenance cost is $5,000 annually with no revenue loss, compared to $61,500 in lost revenues and unexpected downtime costs.

Predictive maintenance program steps Setup 1. Develop a list of critical processes, applications and equipment and prioritize each item based on the impact a failure would have. High priority equipment: Directly impacts safety, the environment, revenue, or customer relations Is unique or costly to replace, or used constantly (24x7) Is difficult to find spare parts for or has a long lead time for repair 2. Determine how likely your equipment is to fail, using PdM software, operator knowledge and maintenance history. 3. Combine those two pieces of information failure probability and impact and create an inspection schedule (see sample at right). 4. Set up a database to store measurement results for each piece of equipment. Incorporate baseline data, repair histories, manufacturer recommendations and operator knowledge: when units broke/ how often, why, and what they cost to fix. Test 5. Test the equipment with the appropriate predictive technologies and record the measurements in the PdM database. Monitor 6. Analyze and monitor your measurements for signs of change in operating conditions: vibration measurements trending up, increased current draw for the same process, current lead to ground, increasing bearing temperatures, and so forth. Repair 7. Investigate any warning signs and determine if repairs are necessary. 8. Determine the length of time before failure occurs. Again, if you lack the PdM tools to determine this, rely on technician experience and manufacturer data. 9. Schedule repair before failure. One of the powerful PdM paradigms is not to repair equipment too early or too late. You don t want equipment to go down, but you also don t want to replace equipment if it will continue to run for a year or more. 10. Use your lead-time to properly align resources, check for spare parts, and choose a shutdown time that minimizes the down condition in the plant. 11. Make the repair. Document the results and if appropriate, try to determine the root cause of the failure of the equipment. 12. Take new baseline readings for the repaired/replaced equipment. Inspection schedules Frequency of inspection is based on a number of factors, including safety, the criticality of the equipment, the expense of a failure, and the frequency with which problems impact production and/or maintenance. As assets age, are heavily loaded, or are poorly maintained, inspections may become more frequent. When repairs or modifications are made to equipment, conduct a follow-up inspection. Equipment Type Transformers 440V Motor Control Centers Air conditioned Non-air conditioned or older Max. Time Between Inspections 1 year 6-12 months 4-6 months Electrical distribution equipment 4-6 months Large motors* 1 year Smaller motors 4-6 months *Assumes vibration analysis, machine circuit analysis, lube analysis and thermography are being used. General equipment list Rotating machinery/loads Motors Generators Pumps A/C units Fans Gearboxes Chillers Motor controls & adjustable speed drives Lighting systems Electrical system Switchgear Transformers Cables/wiring Switches Circuit breakers Metering Grounding systems Ground fault protection Surge arrestors Power Factor Correction Filters and reactors Outdoor bus structures Emergency systems UPS Generators Transfer Switch

Standards Reference these standards when creating safe standard work procedures for your PdM program. International Electrical and Electronic Engineers standard IEEE-90 describes the elements of an EPM program, including safety, while 1584-2002 provides a guide for arc flash hazard calculations and ANSI/IEE C2-81 National Electrical Safety Code governs heavy industrial installations. MTS-2001 Maintenance Testing Specifications for Electrical Power Distribution Equipment and Systems from the International Electrical Testing Association (NETA), www.netaworld.org, contains set of step-by-step standard procedures for inspecting, testing and evaluating system components and an appendices that recommends maintenance intervals for various components. Standard NFPA 70B Recommended Practice for Electrical Equipment Maintenance from The National Fire Protection Association provides a PdM program overview, as well as an appendix with sample tests and record forms. For each component of the electrical system, it describes how you should inspect and test each sub-element. For example, in the section on rotating machinery it covers stator and rotor windings, then goes into brushes, collector rings, commutators, and then bearings and lubrication. NFPA 70B also includes a section on test methods, including insulation testing, transformer turns-ratio testing, circuit breaker testing and ground impedance testing, and power quality issues such as harmonics, transients, unbalance, sags and swells. Also refer to NFPA 70E Standard for Electrical Safety in the Workplace for safety training, procedures, personal protective gear (PPE) requirements, and lockout/tagout procedures. Occupational Safety and Health Administration OSHA 29 CFR, 1910 Subpart S Electrical and Subpart I Personal Protective Equipment Safety standards for electrical systems, safe work practices, maintenance requirements. ISO 6781 International Standards Organization (ISO) (American National Standards Institute) discusses thermal insulation, qualitative detection of thermal irregularities in building envelopes, and infrared methodology. ASTM International http://www.astm.org ASTM E 1934, 1213, 1311, 1316, and 1256 Standard guide for examining electrical and mechanical equipment with infrared thermography, plus additional thermography references in ASTM 1060 and 1153. 2005 Fluke Corporation. All rights reserved. Printed in U.S.A. 3/2005 2435532 A-US-N Rev A