Re-defining the utility-scale inverter

Similar documents
The Intelligent, Reliable Cloud-Connected Inverter for Utility-Scale Renewable Power

ABB central inverters PVS to 1000 kw

Fronius IG Plus. The next generation grid-connected PV inverter

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

SolarMax P series The power package for residential solar plants

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

Galaxy VM. Three-phase power protection. schneider-electric.com

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Solutions for Photovoltaic Systems. Large buildings and power plants

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

User s Manual Before using the inverter, you need to read and save the safety instructions.

Satcon Solstice 100 kw System Solution

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Off-grid solar and backup power installations

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

INVERTER SYSTEM PRODUCT BROCHURE

MAJORSINE Power Inverter

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

BB800 Off-Grid Solar System

Grid-tie, off-grid solar and backup power solutions. For residential and commercial installations

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Thyristor-controlled power supplies and battery chargers

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Power Electronics Testings

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Application Note: String sizing Conext CL Series

JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL

HYBRID POWER SYSTEMS for TELECOM applications

Uninterruptible Power Supply

CompactLogix Power Supplies Specifications

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Your own power station: For continuous power

Green Energy Solutions

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

SUNNY TRIPOWER 5000TL 12000TL

Power Station Photovoltaic Energy

Technical Information POWER PLANT CONTROLLER

Safety technique. Emergency stop module BO 5988 safemaster

MIDNITE SOLAR AND SOLAR WASHINGTON

Schneider Electric renewable energies catalog

Power Supplies 3. SDN-P DIN Rail Series

How To Make A Fronius Cl Power Inverter

ADDENDUM #1(BID PACKAGE # 3)

Easily connect your switchboards to facility management solutions

Utility Ready Solar PV Inverters

Liebert NXC from 10 to 200 kva

32VFD Variable Frequency Drives for Centrifugal Chillers

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

YSmart Technology Co.,Ltd

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

AC Coupling of Inverters for Grid Tied PV Systems

Permissible ambient temperature Operation Storage, transport

Innovation Powers Efficiency

When Do Solar Electric & Utility Back-Up Systems Make Sense?

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

ABB PSPS Erich Steinmann; Generator control-2013

ABB turnkey stations ULTRA-MVC-S 770 to 3110 kw

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

PCS100 ESS. 2UCD190000E002 Rev C. Grid Connect Interface for Energy Storage Systems 100kVA to 10MVA Technical Catalogue

Three-phase monitoring relay CM-PFE

MCR1900 Media Converter 19-Slot Chassis

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

STRATO LED Drivers 70W, Single output

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Fronius IG Plus. The next generation grid-connectedpvinverter.

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

RM4TG20 three-phase network control relay RM4-T - range V

UPS system for emergency lighting and smoke extraction

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide

Table of Contents. TransformerIQ FAQs 1

QuickSpecs. HP 480/277 Volt Solutions. Overview

Foxboro Evo Process Automation System

Battery Power Inverters

Redundancy Module QUINT-DIODE/40

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Schneider Electric Solar Business Catalog 2013 / 2014

Transcription:

Re-defining the utility-scale inverter We believe in green energy in the ability to meet and contribute to growing power demands while supporting a smart grid that serves a smart society. Solution at a glance Far more than a new inverter, the is the new paradigm for large-scale renewable power installations. It provides greater efficiency in power generation with lower short-term and long-term costs, and a far longer service life. Key Benefits: More power generation and a longer service life: 30+ year service life and conversion efficiency of 98.5% Peak, 98.3% CEC Lower CAPEX: 1500VDC system with fewer inverter stations, less equipment and less wiring Lower OPEX: True Design for Service TM and cloud connectivity for fewer service calls Everywhere: designed and tested for any environment and application PV and Energy Storage, on-grid, off-grid or microgrid Secure: backed by a bankable company with 180 years of history Global specialist in energy management 160,000+ total workforce in 100+ countries 180 years of history True Bankability with Schneider Electric 27 billion in consolidated revenue 7 GW More than 7GW of Schneider Electric s utility scale inverters installed worldwide 5% of Group revenues devoted to annual R&D spend 2.1 billion adjusted net income 2016 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. All information is preliminary and will need to be confirmed at the time of order. DS20160617_ConextSmartGen

Reliable and cloud-connected solar.schneider-electric.com 2 Lifetime reliability Through the most stringent selection and qualification of components, the Conext SmartGen is designed to have a 30 year lifespan with just one major preventive maintenance at mid-life in worst case conditions. The most demanding reliability and environmental testing methodology, developed over 15 years experience in the PV industry, has been applied to ensure that the SmartGen maintains adequate operating margins over its entire lifetime, in even the most severe environments. Built to last in the most severe environments (desert, tropical, continental, sea shore, high seismic) Greater uptime for increased power generation Desert Ocean Continental Tropical True Design for Service TM Ease of service was the driving force behind big and small decisions that shaped the Conext SmartGen. From a comprehensive suite of diagnostics, troubleshooting and maintenance tools to quickly replaceable sub-assemblies, every step of servicing has been meticulously optimized to minimize operating expenses. Designed for one hour mean time to repair and first time fix rate >97% Advanced configuration and service tool with full local and remote functionality Immediate access to all field replaceable systems and components Predictive maintenance Advanced Predictive Maintenance algorithms running in the Power Cloud enable remaining lifetime estimation of major components, as well as failure prediction. JUN 2025 Predict when components or systems may fail, ensuring they can be replaced just in time (not too early, and not too late) Enhanced Predictive Maintenance functionality for network connected inverters through advanced Cloud Computing Advanced configuration and service tool Conext Viewer is a powerful software utility that connects to the inverter locally (via Wi-Fi or wired Ethernet), and remotely allowing for easy and intuitive interaction with the inverter. Advanced troubleshooting, high resolution oscillography, lifetime service logging, remote firmware upgrades, online service documentation and help files all the power and capabilities of the digital world supporting your Conext SmartGen inverter. Reduced learning curve that increases user satisfaction and minimizes risks Incorporated help mechanism that enables service personnel to do fast and accurate troubleshooting See True Design for Service and Power of Data brochures

Part of a complete solution Power EcoSystem by Schneider Electric solar.schneider-electric.com 3 MASKED PRODUCT IMAGE The Conext SmartGen is at the center of Schneider Electric s Power EcoSystem a suite of integrated applications that provide remote control, visibility, and analytics for owners, operators and service staff. In addition to the Conext SmartGen, our full ecosystem of products and solutions work together to secure your return on investment. Grid Operator Power Plant Controller String Combiners Plant Operator Weather Station MV Protection Relay MV Breaker Conext SmartGen TM Advisor 2 Power Cloud Owner/ Investor Battery Management System Viewer Schneider Electric Expert Power Plant Controller: ensures that requests and compliance requirements from the utility are met. Conext Advisor 2: webbased software for control-room administration and performance management of PV power plants. Schneider Electric Field Services O&M Company Field Services Conext Power Cloud: data mining and data collection tool for advanced predictive maintenance and better remote service support. Conext Viewer: configuration and service software, including diagnostics, troubleshooting tools, and contextualized help.

Product specifications solar.schneider-electric.com 4 Device short name CS 1670 CS 1800 CS 2000 Electrical specifications AC Nominal output power at 45 C 1670 kva 1791 kva 2000 kva Nominal output power at 50 C 1570 kva 1684 kva 1880 kva Nominal output voltage 480 V 515 V 575 V Nominal frequency 50/60 Hz 50/60 Hz 50/60 Hz Maximum output current at 45 C 2008 A 2008 A 2008 A Maximum output current at 50 C 1888 A 1888 A 1888 A Continuous operation output voltage range +/- 20% (384-576 V) +/- 20% (412-618 V) +/- 20% (460-690 V) Continuous operation frequency range 50 / 60 Hz +/- 10% 50 / 60 Hz +/- 10% 50 / 60 Hz +/- 10% Power factor 0 to 1 lead/lag 0 to 1 lead/lag 0 to 1 lead/lag Harmonic distortion (THDI) < 3% at rated power < 3% at rated power < 3% at rated power Peak efficiency 2 98.6% (Target) 98.6% (Target) 98.6% (Target) Weighted efficiency (CEC weightings) 2 98.3% (Target) 98.3% (Target) 98.4% (Target) Weighted efficiency (EU weightings) 2 98.2% (Target) 98.2% (Target) 98.4% (Target) DC Nominal input voltage range, MPPT 1 750 V - 1500 V 800 V - 1500 V 890 V - 1500 V Nominal input voltage range, operating 750 V - 1500 V 800 V - 1500 V 890 V - 1500 V Max. input voltage, open circuit 1500 V 1500 V 1500 V Max. input operating current at 45 C 2272 A 2285 A 2293 A Max. input operating current at 50 C 2136 A 2148 A 2156 A Max. input short-circuit current 6000 A 6000 A 6000 A Max. input short-circuit current at STC conditions 4480 A for UL models / 5600 A for IEC models DC combiner Integrated Integrated Integrated Number of DC inputs 10 to 14 10 to 14 10 to 14 DC fuse rating General specifications 160A to 400A Service life 30 years 3 30 years 3 30 years 3 Power consumption, night time < 156 W (Target) 4 < 156 W (Target) 4 < 156 W (Target) 4 Degree of protection Outdoor (Type 4X / IP65) 5 Outdoor (Type 4X / IP65) 5 Outdoor (Type 4X / IP65) 5 Enclosure Seismic rating Product weight (estimate only) Product dimensions (H x W x D) Ambient air temperature for operation Operating altitude Relative humidity Features Type of cooling Aluminum IEEE 693-2005 qualification to high seismic performance levels (ZPA = 1.0g 2% damping) IBC ICC-ES AC156-2012 certification to a SDS equal to 1.78g and with a z/h equal to 0 and IP=1.5U BC Zone 4 2800 kg (6160 lb) 220 x 300 x 130 cm (86.6 x 118.1 x 51.2 in) -40 C to 60 C (-40 F to 140 F) -40 C to -25 C (-40 F to -13 F) requires optional heaters 2,000 m without derating, up to 4,000 m with derating 5% to 100% condensing Temperature-dependent low pressure closed-loop liquid cooling Graphic user interface Viewer application for mobile, tablet and PC External communication interface RS485/Modbus standard, Modbus over TCP/IP, and Ethernet/IP TM optional AC/DC disconnect Ground fault detection/interruption Options Standards Safety standards Integrated load-break-rated DC and AC circuit breaker standard Isolation monitoring relay and pre-connection isolation monitoring relay with GFDI and RCD Grounding (floating, positive grounding, negative grounding), string current monitoring, class I surge arresters, AC insulation monitoring, cold environment option (-40 C, -40 F) IEC version: IEC62109-1, -2 / NA version: UL1741 EMC standards IEC61000-2-2, -2-4 ; FCC Class B ; CiSPR 11 Ed. 6 Grid interconnection IEEE1547, California Rule 21, BDEW, CEI, French Decree, IEC61727, PEA, South Korea, CPC and more 1 MPPT for Power Factor 0 to 1 lead/lag. Applicable up to 40 C. Contact Schneider Electric for derating information. 2 Target numbers don t include auxiliary losses. 3 Designed for a service life of 30 years with preventative maintenance. 4 Estimated 312W on a SmartGen Power System with two inverters. Average of 156W per inverter (312W/2). 5 Except heat exchanger section and DC wiring compartment. 2016 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. All information is preliminary and will need to be confirmed at the time of order. DS20160617_ConextSmartGen

PRELIMINARY solar.schneider-electric.com 5 Product options Conext SmartGen TM Extreme Cold Option IEC and UL versions Multiple grounding options Cold start ability down to -40ºC UL version includes NEC compliant DC Floating with permanent isolation monitoring (-40ºF) Secure operation in the harshest environmental conditions Negative or positive grounding with pre-connection insulation check, RCD, and GFDI protection disconnect switches Optional AC insulation monitoring Reduced footprint Easier fuse servicing Enhanced personnel and equipment safety Class I surge arrestors Selectable on DC mains, AC mains and AC auxiliary inputs Enhanced protection against lightning Integrated Communications and Control Panel Modbus / TCP or Ethernet / IP gateway Conext Advisor 2 communications hub for all skid mounted and field equipment Conext Advisor 2 Programmable Logic Controller for fast controls of PV and ES inverters Copper or fiber optic switch for your Conext Advisor 2 communications hub Auxiliary Power Distribution Panel Selection of auxiliary AC voltage (100/110/120/200/220/230/240V) Input circuit breaker with under voltage release Auxiliary consumption metering 10 to 14 inputs with 160 to 400A fusing Input channel current monitoring Power supply to string combiners Wide range of communication protocols Fully integrated monitoring and control hardware Varied DC Input Configurations Elimination of external low voltage panel 2016 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. All information is preliminary and will need to be confirmed at the time of order. DS20160617_ConextSmartGen Wide range of overpaneling ratio