Application program usage. Functional description. Note. Note. instabus EIB Application Program Description. August 2009. 12 CO IP-Interface 720001



Similar documents
Application software. IP/KNX Interface Electrical / Mechanical characteristics : see product information. Order number. TP device RF devices

KNX IP INTERFACE IN00A02IPI. Operating and installation manual

KNX IP Interface. Operating and installation manual

IN00A01IPI. Hardware specification KNX IP INTERFACE IN00A02IPISH IN00A02IPISH Specifica N. Progetto N. Titolo del progetto

EIB/KNX IP Interface with Power over Ethernet (PoE)

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ABB i-bus KNX IP Router IPR/S 2.1

instabus EIB Manual February 2004 Table of Contents

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Follow these steps to prepare the module and evaluation board for testing.

ethernet connection For more information about the printer's ethernet feature, click the topic below: ethernet lights network configuration page

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Application & Quick-Start Guide

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

User Manual Network Interface

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

Check Your Package Contents. CD-ROM containing Manual and Warranty

BROADBAND INTERNET ROUTER USER S MANUAL. Version Page 1 of 13 -

Wireless Router Setup Manual

STATIC IP SET UP GUIDE VERIZON 7500 WIRELESS ROUTER/MODEM

1. Hardware Installation

LAN TCP/IP and DHCP Setup

EMG Ethernet Modbus Gateway User Manual

Chapter 4 Management. Viewing the Activity Log

Internet for Everyone In-Room Instructions January 2011 Version 1.3

Appendix C. Network Requirements. The Browser Interface. For Windows

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

DSL Installation Guide

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

The PostBase Connectivity Wizard

Multi-Homing Dual WAN Firewall Router

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

UPS Network Interface. Quick InstallationGuide

3.5 LAN HDD Enclosure User s Manual

Firewall VPN Router. Quick Installation Guide M73-APO09-380

(1) Network Camera

IP Power Stone 4000 User Manual

Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version /2004

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo

3.5 EXTERNAL NETWORK HDD. User s Manual

DI-634M. Check Your Package Contents. This product can be set up using any current web browser, i.e., Internet Explorer 6 or Netscape Navigator 7.

AXIS 205 Network Camera Quick Installation Guide

Victoria Combo Remote Control

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

IDDERO HOME SERVER. Quick start guide

Broadband Router ALL1294B

Preparing the Computers for TCP/IP Networking

c. Securely insert the Ethernet cable from your cable or DSL modem into the Internet port (B) on the WGT634U. Broadband modem

SNMP Web Management. User s Manual For SNMP Web Card/Box

NETVIGATOR Wireless Modem Setup Guide. (TG789Pvn)

Chapter 3 Management. Remote Management

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Chapter 2 Connecting the FVX538 to the Internet

Wireless LAN g USB Adapter

Linksys Gateway SPA2100-SU Manual

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

EZ-View Network Communications Guide

IntesisBox KNX Modbus TCP master

Connecting the DG-102S VoIP Gateway to your network

LevelOne. User Manual. FBR-1430 VPN Broadband Router, 1W 4L V1.0

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

User s Manual. Copyright 2010 Vantec Thermal Technologies. All Rights Reserved.

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

1 Serial RS232 to Ethernet Adapter Installation Guide

User Manual. EtherUSB

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer.

IP SERIAL DEVICE SERVER

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

TR-7W Configuration Guide. Before You Start

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

Chapter 7 Troubleshooting

OUTDOOR IR NETWORK CAMERA Series

DSL- G604T Frequently asked Questions.

SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

Chapter 10 Troubleshooting

UIP1868P User Interface Guide

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

HWg-STE HWg-STE PoE MANUAL

Chapter 6 Using Network Monitoring Tools

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

ProSAFE 8-Port and 16-Port Gigabit Click Switch

ABB solar inverters. User s manual ABB Remote monitoring portal

HC Products ILF-100WD User Manual

1. MOXA NPort Express TCP/IP to RS-232 server

AXIS 205 Network Camera Goes anywhere your network goes

IS SERIES. QuikStart Programming Guide. IP Network Direct System. Programming Videos

Fronius Datalogger Web

CPEi 800/825 Series. User Manual. * Please see the Introduction Section

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

ADSL MODEM. User Manual V1.0

TW100-BRV204 VPN Firewall Router

Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version

Transcription:

Application program usage Product family: Product type: Manufacturer: System devices IP-Interface Siemens Name: IP Interface N148/21 Order-No.: 5WG1 148-1AB21 Name: IP Interface N148/22 Order-No.: 5WG1 148-1AB22 Functional description In the following description the name IP Interface is used when the description applies to IP Interface N148/21 and IP Interface N148/22. The IP Interface is a DIN rail mounted device. This device utilizes the KNXnet/IP standard and enables communication connections to KNX/EIB lines or systems via data networks using the Internet Protocol (IP). PC s or other data processing equipment can exchange data with KNX/EIB devices through this communication link. The physical connection to the KNX/EIB bus is established via a bus connector terminal block. For connection to the data network (IP via 10BaseT) the device contains an RJ45 socket. By using a LAN modem a KNX/EIB installation can be remotely accessed even if there is no direct data network connection between a PC and an IP Interface. LAN modems are available on the market for standard telephone, ISDN or DSL connections. The IP Interface requires additional operating power for its operation. The IP Interface N148/21 sources the operating power via a second terminal block (white-yellow terminals) from a safety extra low voltage (SELV) power supply AC/DC 24 V. The IP Interface N148/22 can source this operating power via the network connection from Power over Ethernet according to IEEE 802.3af. Alternatively, the operating power can be provided via a second terminal block (white-yellow terminals) by a safety extra low voltage (SELV) power supply AC/DC 24 V or by a bus power supply (unchoked power, DC 29V). When a SELV power supply is connected the operating power is sourced from it. The IP Interface has these characteristics: Simple connection to hierarchically superimposed systems via Internet Protocol (IP) Direct access to the KNX/EIB installation from any access point to the IP network (KNXnet/IP Tunneling) Communication between buildings and facilities LED display of - operation - KNX/EIB communication - IP communication Simple configuration with standard ETS Easy connection to SCADA and Facility Management systems (see: Supported Software) KNXnet/IP Tunneling interface to the bus A direct connection between a networked PC and the bus can be established via a data network and the IP Interface N 148/22. This allows for accessing the bus from any access point in the data network. The IP Interface N148/21 provides one KNXnet/IP Tunneling connection. The IP Interface N148/22 provides up to five KNXnet/IP Tunneling connections, allowing for e.g. simultaneous configuration with ETS3 and operation of a visualization. For stable communication via KNXnet/IP Tunneling the IP Interface must use a separate individual address for each KNXnet/IP Tunneling connection. These additional individual addresses must be different from the individual address of the device and must not be used by any other bus device. In ETS these individual addresses should be reserved by proxy devices. ObjectServer interface to the bus (N148/22) A direct connection between a networked PC and the bus can also be established via a data network and the IP Interface N148/22 using ObjectServer. ObjectServer compared with KNXnet/IP Tunneling provides the advantage that the communication can be maintained even over network connections with a transmission time for the datagrams of over one second (e.g. satellite connections). Assignment of additional individual address(es) (IP Interface N148/21) The additional individual address is assigned with ETS (see: Setting the additional individual address of the IP Interface with ETS3). Siemens AG 720001, 6 pages Technical manual Business Sector Electrical Installation Technology Siemens AG 2009 Update: http://www.siemens.com/gamma 3.10.1.5.1/1

(IP Router N146/02) Additional individual addresses are either assigned with ETS (see: Setting the additional individual address of the IP Interface with ETS3) or alternatively without a tool automatically by the device itself. The automatic address assignment for KNXnet/IP Tunneling and ObjectServer is started when the learning button is pressed during normal operation for more than 5 seconds but less than 10 seconds. The programming LED flashes during the address assignment process. The device checks which individual addresses are already used by other bus devices connected to the bus line. These addresses are not used for the address assignment. By adding additional bus devices at a later time one or more of the additional individual addresses could be assigned twice. When during normal operation the learning button is pressed for more than 10 seconds all additional individual addresses in the IP Interface N148/22 are reset to the default value (15.15.255) and the programming LED is turned off. The IP Interface can be reset to the default factory settings by pressing the learning button for more than six seconds when the operation voltage is turned on. The transition to the default state is indicated by a blinking programming LED. All parameter settings are deleted by this reset action. IP address assignment Please consult your network administrator regarding configuration of the parameters device IP address, subnet mask, and DHCP. The IP address of the IP Interface N148/22 is assigned manually using ETS, automatically by a DHCP server in the IP network, or by the device itself (AutoIP). Assignment of the IP address by a DHCP server allows for changes of the device IP address without using ETS. Configuration of the DHCP server may require the MAC address, which is printed on the device. If a DHCP server is not available the device assigns itself an IP address (AutoIP). Default factory settings The IP Interface ships with these default factory settings: Physical address of the IP Interface: 15.15.15 (= FFFF hex) IP address assignment via DHCP Configuration with ETS The IP Interface N 148/21 can be configured with ETS2 V1.2 and later versions. Technical manual 720001, 6 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2009 Business Sector Electrical Installation Technology 3.10.1.5.1/2

Communication objects The application program does not contain any communication objects. General Device name (max. 30 char) IP Interface N148 This parameter determines the name (max. 30 characters) of the IP Interface, which is used for easy recognition of the device when searched by an KNXnet/IP visualisation or the ETS. IP Address Assignment by DHCP Server manual input This parameter determines the type of IP address assignment. By default the parameter is set for automatic assignment of the IP address by a DHCP server. If manual input is selected two additional tabs appear for manual input of the IP address, subnet mask, and the default gateway address. IP Konfiguration IP Config 1 Interface. The factory default setting for the IP address is 0.0.0.0. This default value must be replaced by a valid IP address. Each byte of the four byte IP Routing Multicast Address is set separately, with a value range of 0...255 for each byte. IP Subnet Mask 0.0.0.0 Byte 1, Byte 2, Byte 3, Byte 4 This parameter is only visible if manual input was chosen for IP Address Assignment. It determines the IP subnet mask used by the IP Interface. The factory default value is 0.0.0.0. This default value must be replaced by a valid subnet mask. Valid subnet mask values are e.g. 255.255.255.0 or 255.255.240.0. Each byte of the four byte IP Routing Multicast Address is set separately, with a value range of 0...255 for each byte. IP Config 2 IP Standard Gateway 0.0.0.0 Byte 1, Byte 2, Byte 3, Byte 4 This parameter is only visible if manual input was chosen for IP Address Assignment. It determines the IP address of the IP Standard Gateway. The factory default value is 0.0.0.0. This default value may be replaced by a valid IP address. Each byte of the four byte IP Routing Multicast Address is set separately, with a value range of 0...255 for each byte. The Standard Gateway transmits IP datagrams to IP devices with IP addresses outside of the local network. Use the predefined (invalid) IP address (0.0.0.0) if the device shall be configured without a Standard Gateway. IP Address Byte 1, Byte 2, Byte 3, Byte 4 0.0.0.0 This parameter is only visible if manual input was chosen for IP Address Assignment. It determines the IP address of the IP Siemens AG 720001, 6 pages Technical manual Business Sector Electrical Installation Technology Siemens AG 2009 Update: http://www.siemens.com/gamma 3.10.1.5.1/3

Supported Software Here is a list of software supporting the IP Interface. ComBridge Studio IPAS GmbH Grabenstr 149 a 47057 Duisburg [http://www.ipas-products.com] Visualization, Database interface, Notification via email, OPC Server ComBridge Studio is a visualization software that can use the IP Interfaces N148/21 and N148/22, the IP Routers N146 and N146/02, the IP Controller N350E and the IP Viewer N151 as interface to KNX/EIB. Find more information in the GAMMA catalog or at the above listed web site. ETS3 KNX Association De Kleetlaan 5, Bus 11 B-1831 Brussels-Diegem Belgium [http://www.knx.org] Configuration of bus installations via existing data net works (ETS 3.0c or higher) A KNXnet/IP driver is available for ETS3. When this driver is installed ETS3 may use the IP Interfaces N148/21 and N148/22, the IP Routers N146 and N146/02, the IP Controller N350E and the IP Viewer N151 as interfaces to the bus just like a standard RS232 or USB serial interface. This function includes download of device configuration via the bus and the group monitor function of ETS3. When an IP Interface is unloaded this unloading process may fail with the error message An internal error occurred. Subsequently, no other device can be configured and ETS displays the error message An internal error occurred.. When attempting to check the in menu Extras Options Communication the error message Severe error appears. The problem is solved by either selecting a different interface or by closing and restarting ETS. If the communication to the KNX bus fails when a KNXnet/IP Tunneling connection exists then, even if the KNX bus is reconnected, a connection to the bus cannot be established and a download fails. The problem is solved by either selecting a different interface or by closing and restarting ETS. Then a connection to the previously used IP device (IPInterface N148/21 resp. N148/22 or IP Router N146 resp. N146/02) can be established. The same behavior shows if the power to the IP device fails. If the IP Interface N148/22 is used as an interface to the bus and its own configuration is downloaded via the bus then ETS displays the error message The device with the individual address %1 cannot be found.. The download is not executed. The problem is solved by either selecting a different interface or by closing and restarting ETS. Then a connection to the IP Interface N148/22 can be established. The ETS3 driver currently does not support local download. When attempting a local download to the IP Interface N148/22 this message appears: "incompatible BCU version $091A (required $0012)". After installing the ETS3 driver and selecting the IP Interface N148/22 or the IP Router N146/02 as communication interface a windows message may pop up announcing that a "Class" is unknown. In this case install the Microsoft.Net Framework that you can download from the Microsoft software update site (file size: approx. 25MB). Technical manual 720001, 6 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2009 Business Sector Electrical Installation Technology 3.10.1.5.1/4

Setting the communication interface in ETS3 In ETS3 select Extras Options. In the Options window select the Communication tab. Click on Configure Interfaces. (1) Select an IP Interface from the list. (2) Assign a name to this new interface. The result could look like this. Generate a new interface and select the type KNXnet/IP. ETS3 automatically searches for all reachable IP Interfaces. Siemens AG 720001, 6 pages Technical manual Business Sector Electrical Installation Technology Siemens AG 2009 Update: http://www.siemens.com/gamma 3.10.1.5.1/5

Setting the additional individual address of the IP Interface with ETS3 For a stable communication with the IP Interface via KNXnet/IP Tunneling a additional individual address must be set using ETS3. General s The operating instructions must be handed over to the client. A faulty device shall be sent with a Return Good for Service provided by the appropriate Siemens sales office to the following address: SIEMENS AG, Siemensstr. 10, D-93055 Regensburg If you have further questions concerning the product please contact our technical support: +49 (0) 180 50 50-222 (0,14 /min. from the German landline network, deviating mobile communications prices are possible) +49 (0) 180 50 50-223 E-Mail: support.automation@siemens.com www.siemens.com/automation/support-request Click on. ETS3 fetches the current setting of the additional individual address from the IP Interface. The factory setting of the additional individual address of the IP Interface is 15.15.255. Enter the desired additional individual address and acknowledge this entry by clicking on OK. ETS3 sets the value in the IP Interface and closes the window. When entering the additional individual address take care that this individual address is not used by another bus device. A Dummy device with this individual address should be inserted in the ETS project. Technical manual 720001, 6 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2009 Business Sector Electrical Installation Technology 3.10.1.5.1/6