Validation and Calibration. Definitions and Terminology



Similar documents
Applying Statistics Recommended by Regulatory Documents

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA

Working Party on Control of Medicines and Inspections. Final Version of Annex 15 to the EU Guide to Good Manufacturing Practice

ASSURING THE QUALITY OF TEST RESULTS

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

Guidance for Industry

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

White paper: FDA Guidance for Industry Update Process Validation

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

Assay Development and Method Validation Essentials

Method Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory

FDA Guidance for Industry Update - Process Validation

Analytical Methods: A Statistical Perspective on the ICH Q2A and Q2B Guidelines for Validation of Analytical Methods

American Association for Laboratory Accreditation

General and statistical principles for certification of RM ISO Guide 35 and Guide 34

Guidance for Industry

USE OF REFERENCE MATERIALS IN THE LABORATORY

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

APPENDIX N. Data Validation Using Data Descriptors

QbD Approach to Assay Development and Method Validation

Ecology Quality Assurance Glossary

Design of Experiments for Analytical Method Development and Validation

SPECIFICATIONS AND CONTROL TESTS ON THE FINISHED PRODUCT

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

Methods verification. Transfer of validated methods into laboratories working routine. Dr. Manuela Schulze 1

ISO How to Meet. Requirements for Method Verification. Prepared by:

Quality Assurance/Quality Control in Acid Deposition Monitoring

QUALITY MANAGEMENT IN VETERINARY TESTING LABORATORIES

A commitment to quality and continuous improvement

Glossary of Terms for Quality Assurance and Good Laboratory Practices

Guide to Method Validation for Quantitative Analysis in Chemical Testing Laboratories

To avoid potential inspection

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Validation of measurement procedures

Control Charts and Trend Analysis for ISO Speakers: New York State Food Laboratory s Quality Assurance Team

Implementing New USP Chapters for Analytical Method Validation

Assay Qualification Template for Host Cell Protein ELISA

Guidance for Industry

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

Contents. Abstract...i. Committee Membership... iii. Foreword... vii. 1 Scope...1

PROPOSED UPDATED TEXT FOR WHO GOOD MANUFACTURING PRACTICES FOR PHARMACEUTICAL PRODUCTS: MAIN PRINCIPLES (JANUARY 2013)

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

OPERATIONAL STANDARD

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

COMPLIANCE BY DESIGN FOR PHARMACEUTICAL QUALITY CONTROL LABORATORIES INSIGHT FROM FDA WARNING LETTERS

STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION

Magruder Statistics & Data Analysis

Lifecycle Management of Analytical Procedures; What is it all about? Jane Weitzel Independent Consultant

Cleaning Validation in Active pharmaceutical Ingredient manufacturing plants

DECISION LIMITS FOR THE CONFIRMATORY QUANTIFICATION OF THRESHOLD SUBSTANCES

Terms concerned with internal quality control procedures

Definition of Minimum Performance Requirements for Analytical Methods of GMO Testing European Network of GMO Laboratories (ENGL)

Overview of ISO for 'Biologicals'

Analytical Test Method Validation Report Template

11.I In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07

ALACC Frequently Asked Questions (FAQs)

Evaluating Laboratory Data. Tom Frick Environmental Assessment Section Bureau of Laboratories

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

GUIDE TO GOOD MANUFACTURING PRACTICE FOR MEDICINAL PRODUCTS ANNEX 15 *

Annex 2. WHO good manufacturing practices for pharmaceutical products: main principles 1

Gravimetric determination of pipette errors

American Association for Laboratory Accreditation

The Determination of Uncertainties in Charpy Impact Testing

Comparison Chart of FDA and EPA Good Laboratory Practice (GLP) Regulations and the OECD Principles of GLP

MEDICAL DEVICE GUIDANCE

Gap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing

Process Performance Qualification. Demonstrating a High Degree of Assurance in Stage 2 of the Process Validation Lifecycle

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

QUALITY ASSURANCE and QUALITY CONTROL DATA STANDARD

Procedure for Equipment Calibration and Maintenance

Northumberland Knowledge

Quantifying Uncertainty in Analytical Measurement

Guidance on Qualification of existing facilities, systems, equipment and utilities

IAEA-TECDOC Development and use of reference materials and quality control materials

Sample Analysis Design Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors:

Analytical Procedures and Methods Validation for Drugs and Biologics

NABL NATIONAL ACCREDITATION

Annex 1 WHO good practices for pharmaceutical quality control laboratories

FORENSIC TOXICOLOGY LABORATORY OFFICE OF CHIEF MEDICAL EXAMINER CITY OF NEW YORK PROFICIENCY TESTING

How to Verify Performance Specifications

Quality by Design Approaches to Analytical Methods -- FDA Perspective. Yubing Tang, Ph.D. FDA/CDER/ONDQA AAPS, Washington DC October 25, 2011

Annex 9 Guide to good storage practices for pharmaceuticals 1

CHAPTER ONE TABLE OF CONTENTS 1.0 INTRODUCTION... 1

TEST REPORT: SIEVERS M-SERIES PERFORMANCE SPECIFICATIONS

LAB 37 Edition 3 June 2013

GLP vs GMP vs GCP Dominique Pifat, Ph.D., MBA The Biologics Consulting Group

Procedure for Writing Technical Procedures

Workshop B Control Strategy

Performance and advantages of qnmr measurements

Proficiency Testing In A Global Analytical Environment Benefits & Challenges. AOAC September 2007

Evaluating Current Practices in Shelf Life Estimation

Certifying Reference Materials to ISO Guide 34

Check-list for auditors. Audit visit at candidate registered laboratories

Transcription:

Validation and Calibration Definitions and Terminology ACCEPTANCE CRITERIA: The specifications and acceptance/rejection criteria, such as acceptable quality level and unacceptable quality level, with an associated sampling plan that are necessary for making a decision to accept or reject a lot or batch of raw material, intermediate, packaging material, or active pharmaceutical ingredient. This term can also be applied to validation. ACCURACY - The degree of agreement between a measured value and the accepted reference value. ACCURACY - The degree of correlation with the value achieved by the previous method (WHO Polio Manual 2 (3.2), 2005). ACCURACY - The degree of closeness of the determined value to the nominal or known true value under prescribed conditions. This is sometimes termed trueness. (FDA. Guidance for industry. Bioanalytical Method Validation, 2001). ACCURACY OF MEASUREMENT- Closeness of the agreement between the result of a measurement and a true value of the measurement. (ISO 15189:2007, Medical laboratories - Particular requirements for quality and competence) ACTION LIMITS - The range limits which include 99.7 % of the results (±3 standard deviations). Any results laying outside these limits requires an immediate corrective action. (ISRAC Policy and evaluation of control Testing Performed by Accredited Testing & Calibrations Laboratories, 1-681001, version 03, 2008) ALERT LIMITS - CONTROL LIMITS - The range limits that include all 95% of the results (±2 standard deviations). These limits are also named the warning limits. (ISRAC Policy and evaluation of control Testing Performed by Accredited Testing & Calibrations Laboratories, 1-681001, version 03, 2008)

BATCH (or LOT) - A defined quantity of starting material, or product processed in a single process or series of processes so that it is expected to be homogeneous. 2004). BIAS - The difference between the expectation of the test results and an accepted reference value. Bias is the total systematic error as contrasted to random error. There may be one or more systematic error components contributing to the bias. A larger systematic difference from the accepted reference value is reflected by a larger bias value. (ISO 3534-1: 2006 Statistics -- Vocabulary and symbols) BIOLOGICAL MATRIX - A discrete material of biological origin that can be sampled and processed in a reproducible manner. Examples are blood, serum, plasma, urine, feces, saliva, sputum, and various discrete tissues. BLANK - A sample of a biological matrix to which no analytes have been added that is used to assess the specificity of the bioanalytical method. CALIBRATION - The set of operations that establish, under specified conditions, the relationship between values indicated by a measuring instrument or measuring system, or values represented by material measure and the corresponding values of the measurand. (National Conference of Standards Laboratories, NCSL RP-1, 1996). CALIBRATION - An operation that, under specified conditions, in a first step establishes a relation between the quantity values with "measurement uncertainties" provided by measurement standards and corresponding indications with associated "measurement uncertainties" and, in a second step, uses this information to establish a relation for obtaining a measurement result from an indication. (Analytical Methods and reference Materials program, AMRM Glossary, NIH, USA, 2009) CALIBRATION - The demonstration that a particular instrument or device produces results within specified limits by comparison with those produced by a traceable standard over an appropriate range of measurements. (FDA Guidance, part 7. Manufacturing, Processing, or Holding Active Pharmaceutical

CALIBRATION INTERNAL - Calibration of the laboratory equipment is performed by the laboratory according to its requirements. A laboratory accredited to Internal Calibration is not accredited for selling calibration services to outside customers. (ISRAC Policy on - Traceability and Uncertainty of Measurement, 1-661002, version 07, 2009) CALIBRATION STANDARD - A biological matrix to which a known amount of analyte has been added or spiked. Calibration standards are used to construct calibration curves from which the concentrations of analytes in QCs and in unknown study samples are determined. CALIBRATION GRAPH - Plot of analytical response vs. known mass or concentration of analyte. CALIBRATION (standard) CURVE - The relationship between instrument response and known concentrations of the analyte. CRITICAL OPERATION - An operation in the manufacturing process that may cause variation in the quality of the pharmaceutical product. 2004). CROSS-VALIDATION - A comparison of validation parameters when two or more bioanalytical methods are used to generate data within the same study or across different studies. An example of cross-validation would be a situation where an original validated bioanalytical method serves as the reference and the revised bioanalytical method is the comparator. EXAMINATION - Set of operations having the object of determining the value or characteristics of a property. In some disciplines (e.g. microbiology) an examination is the total activity of a number of tests, observations or measurements. (ISO 15189:2007, Medical laboratories - Particular requirements for quality and competence). GMP (Good Manufacturing Practice) - All elements in the established practice that will collectively lead to final products or services that consistently meet appropriate specifications and compliance with national and international regulations. (PIC/S GMP Guide for blood establishments, PE 005-2, 2004)

IN-PROCESS CONTROL - Checks performed during production in order to monitor and, if necessary, to adjust the process to ensure that the product conforms to its specification. 2004). INSTALATION QUALIFICATION - Establishing confidence that process equipment and ancillary systems are capable of consistently operating within established limits and tolerances. (FDA, Guidelines on General Principles of Process Validation. Rockville, MD, May 1993, updated 2009.). LINEARITY - The linearity of an analytical procedure is its ability (within a given range) to obtain test results which are directly proportional to the concentration (amount) of analyte in the sample. (FDA. Guideline for Industry. Text on Validation of Analytical Procedures, ICH-Q2A, 1995). LOD - Limit of detection - Smallest amount of analyte which can be distinguished from background. LOD - The lowest concentration of an analyte that the bioanalytical procedure can reliably differentiate from background noise. (FDA. Guidance for industry. Bioanalytical Method Validation, 2001). LOQ - Limit of quantification - The lowest (LLOQ - Lower Limit) or highest (ULOQ - Upper Limit) amount of an analyte in a sample that can be quantitatively determined with suitable precision and accuracy. MATRIX EFFECT - The direct or indirect alteration or interference in response due to the presence of unintended analytes (for analysis) or other interfering substances in the sample. MEASUREMENT- Set of operations having the object of determining a value of a quantity. (ISO 15189:2007, Medical laboratories - Particular requirements for quality and competence). MEDIA BLANK - An unexposed sampler, not taken to the field or shipped, used for background correction of sample readings or for recovery studies.

METHOD - A comprehensive description of all procedures used in sample analysis. PACKAGING MATERIAL - Any material, including printed material, employed in the packaging of a pharmaceutical, but excluding any outer packaging used for transportation or shipment. Packaging materials are referred to as primary or secondary according to whether or not they are intended to be in direct contact with the product. 2004) PRECISION - The repeatability or reproducibility of individual measurements expressed as standard deviation (SD), or relative standard deviation (CV). PRECISION - The variation of the results as represented by the standard deviation or the coefficient of variation. (WHO Polio Manual 2 (3.2), 2005). PRECISION - The closeness of agreement (degree of scatter) between a series of measurements obtained from multiple sampling of the same homogenous sample under the prescribed conditions. (FDA. Guidance for industry. Bioanalytical Method Validation, 2001). PROFICIENCY TESTING - Any interlaboratory testing program where stable specimens are sent to participating laboratories for analysis. Results from all participating laboratories are compared, pooled, and tabulated by the testing program operator with the purpose of improving laboratory performance. (National Institute for Occupational Safety and Health, U. S. NIOSH Manual of Analytical QUALIFICATION - The action of proving that any equipment or process works correctly and consistently and produces the expected results. Qualification is part of, but not limited to, a validation process, i.e., installation qualification (IQ), operation qualification (OQ), and performance qualification (PQ).

QUALITY ASSURANCE - The sum total of the organized activities performed with the intent to ensure that all APIs are of the quality required for their intended use. QUALITY ASSURANCE - All planned and systematic activities implemented within the quality system and demonstrated as needed to provide adequate confidence that an entity will fulfil requirements for quality. (PIC/S GMP Guide for blood establishments, PE 005-2, 2004) QUALITY CONTROL - Operational techniques and activities that are used to fulfill the requirements for quality in compliance with the specification. (PIC/S GMP Guide for blood establishments, PE 005-2, 2004) QUALITY CONTROL UNIT - Any person or organizational element designated by the firm to be responsible for the duties relating to quality control. QUALITY MONITORING - That part of a quality assurance program concerned with maintenance and improvement of quality which deals with the identification and use of indicators to detect variations from standards or specifications. (PIC/S GMP Guide for blood establishments, PE 005-2, 2004) QUARANTINE - The status of materials isolated physically or by other effective means pending a decision on their subsequent use. RANGE - The interval between the upper and lower concentration (amounts) of analyte in the sample (including these concentrations) for which it has been demonstrated that the analytical procedure has a suitable level of precision, accuracy and linearity. (FDA. Guideline for Industry. Text on Validation of Analytical Procedures, ICH-Q2A, 1995). RAW MATERIAL - Any ingredient intended for use in the production of APIs. These may include starting materials, process aids, solvents, and reagents.

REPRODUCIBILITY - The precision of the procedure when it is performed under different conditions. (WHO Polio Manual 2 (3.2), 2005). REPRODUCIBILITY - The precision between two laboratories. It also represents precision of the method under the same operating conditions over a short period of time. (FDA. Guidance for industry. Bioanalytical Method Validation, 2001). REFERENCE MATERIAL - A generic term that refers to a material or substance whose property values are sufficiently homogeneous and stable with respect to one or more specified properties, and whose fitness is well established for its intended use in a measurement process (e.g., calibration of an apparatus, the assessment of a measurement method, or for assigning values to materials). (Analytical Methods and reference Materials program, AMRM Glossary, NIH, USA, 2009). REFERENCE VALUE - ASSIGNED VALUE - The quantitative or qualitative value that is assigned (accepted by convention as being the true value with known and acceptable uncertainty) to a Control Test Sample or primary standards. (ISRAC Policy and evaluation of control Testing Performed by Accredited Testing & Calibrations Laboratories, 1-681001, version 03, 2008). ACCEPTED REFERENCE VALUE - A value that serves as an agreed-upon reference for comparison, and which is derived as: a) a theoretical or established value, based on scientific principles; b) an assigned or certified value, based on experimental work of some national or international organization c) a consensus or certified value, based on collaborative experimental work under the auspices of a scientific or engineering group d) when a), b) and c) are not available, the expectation of the (measurable) quantity, i.e. the mean of a specified population of measurements (ISO 3534-1: 2006 Statistics -- Vocabulary and symbols) ROBUSTNESS - ability to provide accurate and precise results under a variety of conditions. (WHO Polio Manual 2 (3.2), 2005). RUGGEDNESS - Partial or complete analysis of variance using experiments in which operational parameters of a sampling and measurement method are varied within a small range to determine their effect on overall variance.

SAMPLE - One or more parts taken from a system and intended to provide information on the system, often to serve as a basis for decision on the system or its production. (ISO 15189:2007, Medical laboratories - Particular requirements for quality and competence). SELECTIVITY - The ability of the bioanalytical method to measure and differentiate the analytes in the presence of components that may be expected to be present. These could include metabolites, impurities, degradants, or matrix components. SENSITIVITY - capacity of the test procedure to record small variations between concentrations. (WHO Polio Manual 2 (3.2), 2005) SPECIFICATION - A list of detailed requirements with which the products or material used or obtained during manufacture have to conform. They serve as a basis for quality evaluation. 2004) SPECIFICITY - the degree of uniformity of the response to the substance in question. (WHO Polio Manual 2 (3.2), 2005). SPIKE - A known mass of analyte added to a sampler for the purpose of determining recovery (analyst spikes), or for quality control (blind spikes). STABILITY - The chemical stability of an analyte in a given matrix under specific conditions for given time intervals. TRUENESS - The closeness of agreement between the average value obtained from a large series of test results and an accepted reference value. NOTE: The measure of trueness is usually expressed in terms of bias. Trueness must not be confused with the term accuracy. (ISO 3534-1: 2006 Statistics -- Vocabulary and symbols) UNCERTAINTY OF MEASUREMENT - Parameter, associated with the result of a measurement, that characterizes the dispersion of the values that could reasonably be attributed to the measurement. (ISO 15189:2007, Medical laboratories - Particular requirements for quality and competence).

VALIDATION - Establishing documented evidence that provides a high degree of assurance that a specific process will consistently produce a product meeting its predetermined specifications and quality attributes. Analytical Methods Validation - The process by which it is established, by laboratory studies, that the performance characteristics of the method meet the requirements for the intended analytical applications. (FDA Guidance, part 7. Manufacturing, Processing, or Holding Active Pharmaceutical On going validation - Control activities of the method characterize that taken during on going testing to approve the method control and that the validation results are valid. (ISRAC Validation policy, 1-661004, version 04, 2007.) Prospective validation - Validation conducted prior to the distribution of either a new product, or product made under a revised manufacturing process, where the revisions may affect the product's characteristics. Retrospective validation - Validation of a process for a product already in distribution based upon accumulated production, testing and control data. (FDA, Guidelines on General Principles of Process Validation. Rockville, MD, May 1993, updated 2009.). Re-validation - Repeating validation for method that already had validation. (ISRAC Validation policy, 1-661004, version 04, 2007) VALIDATION PROTOCOL - A written plan stating how validation will be conducted, including test parameters, product characteristics, production equipment, and decision points on what constitutes acceptable test results. (FDA, Guidelines on General Principles of Process Validation. Rockville, MD, May 1993, updated 2009.). WORST CASE - A set of conditions encompassing upper and lower processing limits and circumstances, including those within standard operating procedures, which pose the greatest chance of process or product failure when compared to ideal conditions. Such conditions do not necessarily induce product or process failure. meeting its predetermined specifications and quality attributes. (FDA, Guidelines on General Principles of Process Validation. Rockville, MD, May 1993, updated 2009). Copyright 2009 by LABMANUAL Corporation. All rights reserved