R&S FSWP Phase Noise Analyzer Instrument Security Procedures

Similar documents
R&S FPS Signal and Spectrum Analyzer Instrument Security Procedures

R&S FSVA/FSV Signal and Spectrum Analyzer Instrument Security Procedures

R&S ESW EMI Test Receiver Instrument Security Procedures

Resolving Security Issues When Working with the R&S FSUP in Secure Areas

R&S RTO Digital Oscilloscope Resolving Security Issues When Working in Secure Areas

Contents. 1 Overview. R&S FSQ - Instrument Security

Resolving Security Issues When Working with the R&S ESU in Secure Areas

Resolving Security Issues when working with R&S UPV, R&S UPV66, R&S UPP200, R&S UPP400, R&S UPP800 in Secure Areas

USB Write Protection Utility

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

ConnectKey 2.0 WorkCentre 6655i 6655

BIOS and CMOS. Overview. The Function of BIOS. The Bus

Firmware Release 4.42 SP2 (XP)

Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

Guide to SATA Hard Disks Installation and RAID Configuration

CSCA0201 FUNDAMENTALS OF COMPUTING. Chapter 5 Storage Devices

Software Utility VNA Frequency Converter Leveling Tool Getting Started

Rohde & Schwarz Service that adds value

Agilent Technologies Truevolt Series Digital Multimeters

Surf it Easy. User Guide

USB. 16MB~2GB JetFlash. User s Manual

Using R&S NRP-Z Power Sensors with Android TM Handheld Devices. Application Note. Products:

Computer Setup User Guide

Common Operating-System Components

and Measurement Software

R&S RNMS3000 Radio Network Management System Utilization planning, radio network configuration and data distribution

Broadcast Drive Test Software

Updating to Windows 8.1

HP VMware ESXi 5.0 and Updates Getting Started Guide

Avira System Speedup. HowTo

R&S NRPV Virtual Power Meter Release Notes Application Version 1.8.0

FLASH USB Introduction ENGLISH

Yamaha 01V96 Version2 Upgrade Guide

Virtual COM Port Driver Installation Manual

Keep it Simple Timing

Virtual COM Port Driver Installation Manual

Carry it Easy +Plus Bio. User Guide

Operating instructions TSE Wireless Software Home

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

R&S IP-GATE IP gateway for R&S MKS9680 encryption devices

PCI SATA Controller Card Model: SY-PCI40010

FTP Automation Guide

R&S FS-K130PC Distortion Analysis Software Specifications

Using AORUS Notebook for the First Time

/ Rev. 0 / Quick Guide for FDT Basic-Tool and Backup-Tool P40-SERIES

Read Me UNISTREAM AUTOMATION IDE

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

USB FLASH DRIVE. User s Manual. USB 2.0 Compliant. Version A Version A10

pco.interface GigE & USB Installation Guide

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

IPMI Firmware Update (AMI) In WEB-GUI/DOS/WIN/Linux

Intel architecture. Platform Basics. White Paper Todd Langley Systems Engineer/ Architect Intel Corporation. September 2010

PowerProtector: Superior Data Protection for NAND Flash

R&S VISA Release Notes Software Version 5.5.4

RenderBooster User manual

Carry it Easy. User Guide

HP UPS R1500 Generation 3

Network Attached Storage User Manual

Instrument Software Update Instructions

Highly Reliable Systems. FirstRAID DXR TM. Documentation Supplement V1.1. Copyright 2007 by Highly Reliable Systems. All Rights Reserved.

R&S FS-K130PC Distortion Analysis Software Amplifier modeling and linearization

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

Windows 7 XP Mode for HP Business PCs

Intel Matrix Storage Manager 8.x

Remote Monitoring and Control of the R&S FSL with a Web Browser

Quick start to evaluating HP Windows Embedded Standard 2009 Thin Clients. HP t5630w, HP t5730w, HP t5740, HP gt7720

Intel Data Migration Software

USER MANUAL. FLASH DUPLICATOR CopyKing II CPY220

FUSION R400 RAID USB 3.0

Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide

Non-Volatile Memory Programming on the Agilent 3070

Spacecraft Computer Systems. Colonel John E. Keesee

Guide to SATA Hard Disks Installation and RAID Configuration

H ARDWARE C ONSIDERATIONS

1. Introduction... 3 Introduction Deal command... 13

Intel Desktop Board D925XECV2 Specification Update

R&S IP-GATE IP gateway for ISDN encryption devices

Manual IB-3620 Series

Dual-boot Windows 10 alongside Windows 8

Sprint 3G/4G Plug-in-Connect USB Web Browser Interface User Guide

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Turn on and immediately start with the engineering! siemens.com/simatic-pg

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

User Manual Web Operating Panel AP User Manual. General Settings, Updating and Troubleshooting

User Manual. 2 ) PNY Flash drive 2.0 Series Specification Page 3

Huawei E169 & E220 Status Lights

PCI-to-SATA RAID Adapter AEC-6890M. User s Manual Version:1.0

EUCIP - IT Administrator. Module 1 - PC Hardware. Version 2.0

Installation and Operation Back-UPS 1250, 1300, 1500

Q2000 Series BIOS BIOS SETUP UTILITY

USING USB FLASH DISK WITH TCMS V2

XL-RAID-SATA2-USB. User Manual. v.1.2 (January, 2010)

Colorfly Tablet Upgrade Guide

Fujitsu LifeBook S Series

Operating instructions TSE Wireless Software Business +

R&S ZNC Vector Network Analyzer Specifications

Model SL355 Noise Dosimeter/Datalogger

Transcription:

Phase Noise Analyzer Instrument Security Procedures (;ÛÇ42) 1177.5704.02 01 Test & Measurement Instrument Security Procedures

This document is applicable to all R&S FSWP models. 2015 Rohde & Schwarz GmbH & Co. KG Mühldorfstr. 15, 81671 München, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 Email: info@rohde-schwarz.com Internet: www.rohde-schwarz.com Subject to change Data without tolerance limits is not binding. R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. The following abbreviations are used throughout this manual: R&S FSWP is abbreviated as R&S FSWP.

Contents Contents 1 Overview... 4 2 Battery Information...5 3 Types of Memory and their Security Concerns...6 4 Information Storage within the R&S FSWP... 7 5 Information Security in Highly Sensitive Areas... 8 6 Performing Service, Calibration and Maintenance on the R&S FSWP... 9 7 Performing Firmware Updates and Backing-Up User Data in Sensitive Areas...11 8 Special Considerations for USB Ports...12 3

Overview 1 Overview In many cases it is imperative that the R&S FSWP be used in a secured environment. Generally these highly secured environments will not allow any test equipment to leave the area unless it can be proven that no user information will leave with the test equipment. Security concerns can arise when test equipment needs to leave a secured area to be calibrated or serviced. This document describes the types of memory and their usage in the R&S FSWP. It also addresses methods of ensuring that no user data will leave the secured area should the product be removed for calibration or service needs. 4

Battery Information 2 Battery Information There are no batteries in the R&S FSWP other than the one on the CPU board used to power the clock in the chipset. 5

Types of Memory and their Security Concerns 3 Types of Memory and their Security Concerns SDRAM The R&S FSWP has 8 GByte of SDRAM on the CPU board and 2 GByte of SDRAM/ DDR3 on the detector board. SDRAM is volatile memory and it loses its memory as soon as power is removed. The SDRAM will be unreadable within one minute after the power is removed from the instrument. The SDRAM is not a security concern. EEPROM Each board assembly in the R&S FSWP has one serial EEPROM device. These devices hold up to 1 MByte and contain information related to the installed hardware, such as board serial number, options, correction constants, etc. The EEPROM does not hold user data nor can the user access the EEPROM storage. The EEPROM is not a security concern. FLASH The CPU board of the R&S FSWP has a 8 MByte flash memory device which contains the BIOS. The FLASH memory device does not hold user data nor can the user access the flash memory. The FLASH memory is not a security concern. Removable Solid-State Drive The R&S FSWP is equipped with a removable solid-state (flash) drive. The solid-state drive is used to store: Instrument operating system (Windows 7, 64 bit) Instrument firmware and firmware options (measurement personalities) with option license keys Instrument states and setups Trace data Limit lines, transducer tables Screen images The solid-state drive content is non-volatile, so nothing is lost when power is removed from the instrument. Furthermore, an optional Secure User Mode (R&S FSWP-K33) is available, in which the instrument's solid-state drive is write-protected. Thus, no user data can be written to the solid state drive permanently (see also "Secure user Mode (R&S FSWP-K33)" on page 8). The solid-state drive is not a security concern because it can be physically removed from the instrument and left in the secure area. 6

Information Storage within the R&S FSWP 4 Information Storage within the R&S FSWP Data SDRAM Not a security concern EEPROM Not a security concern FLASH Not a security concern Removable solid-state drive Not a security concern Temporary information storage for CPU operation (CPU cache and swap area) Hardware info, serial number, product options and calibration correction constants X X X BIOS X Operating system and instrument firmware Instrument states, setups, limit lines and transducer tables Trace data, measurement results and screen images (X)* (X)* X X X *) only if optional Secure User Mode (K33) is active 7

Information Security in Highly Sensitive Areas 5 Information Security in Highly Sensitive Areas Since the SDRAM is erased when power is removed from the R&S FSWP it does not pose a security risk. No user data is written to the EEPROM and FLASH memories; hence, it is deemed that they do not pose a risk either. The Removable solid-state drive is the only device that does not lose its memory when power is removed and can contain user data. It can be removed from the R&S FSWP, leaving the customer assured that no user data is stored within the R&S FSWP. Secure user Mode (R&S FSWP-K33) If it is not possible to remove the solid-state drive and store it securely, or if users must not obtain knowledge of other user's data, an optional Secure User Mode (R&S FSWP- K33) is available. In secure user mode the instrument s solid-state drive is write-protected so that no information can be written to memory permanently. Data that the R&S FSWP normally stores on the solid-state drive is redirected to volatile memory instead, which remains available only until the instrument is switched off. Data that is stored in volatile memory can be accessed by the user just as in normal operation; however, when the instrument s power is removed, all data in this memory is cleared. Thus, in secure user mode, the instrument always starts in a defined, fixed state when switched on. The R&S FSWP equipped with the REMOVABLE SOLID-STATE DRIVE address the needs of customers working in highly sensitive areas. 8

Performing Service, Calibration and Maintenance on the R&S FSWP 6 Performing Service, Calibration and Maintenance on the R&S FSWP R&S FSWP equipped with the removable solid-state drive Before performing service, calibration, or maintenance tasks on the R&S FSWP, remove the classified solid-state drive (with the user data). This can be done without opening the instrument. To remove the solid-state drive IMPORTANT - SHOCK HAZARD: Switch off the instrument and disconnect the power plug before removing the solid-state drive! Unscrew the two knurled screws and remove the solid-state drive at the back of the device. This removes all user data from the R&S FSWP. The R&S FSWP, without the removable solid-state drive, can now leave the secured area. Once the R&S FSWP is outside the secured area, installing a second non-classified removable solid-state drive (without any user data), allows the R&S FSWP to function properly for service or other needs. Prior to re-entering the secured area, remove the non-classified removable solid-state drive (without the user data). When the R&S FSWP is back within the secured area, the original classified removable solid-state drive can be reinstalled. 9

Performing Service, Calibration and Maintenance on the R&S FSWP To hold classified user data in the secure areas, use the REMOVABLE solid-state drive which comes with the instrument. To hold non-classified user data in the non-secure areas, use a second REMOV- ABLE (optional) solid-state drive. Validity of the Instrument s Calibration After Exchanging the Removable Hard Disk The calibration ensures the user that their measurements are traceable to a government standard. Rohde & Schwarz highly recommends that users follow the calibration cycle suggested for their instrument. The EEPROM is the only memory type used to hold permanent adjustment values required to maintain the validity of the R&S FSWP's calibration. Hence, replacing one removable solid-state drive with another does not affect the validity of the instrument s calibration. After exchanging the removable solid-state drive, perform a self-alignment once, by selecting "SETUP > Alignment > Start Self Alignment". This function uses the high-stability internal reference generator to produce the temporary adjustment values. Using the permanent and temporary values, the necessary adjustment information is then stored on the removable solid-state drive. Rohde & Schwarz recommends that users perform the self-alignment function on a weekly basis after the R&S FSWP has had sufficient time to warm-up. 10

Performing Firmware Updates and Backing-Up User Data in Sensitive Areas 7 Performing Firmware Updates and Backing- Up User Data in Sensitive Areas Rohde & Schwarz highly recommends, but does not require, the users of its products to maintain their products with the latest updates and to regularly backup important user data that can be erased. Firmware updates are available from the Rohde & Schwarz website. How does a user perform firmware updates and backup user data in sensitive areas? There are several options available for the user to safely perform these operations without compromising the security of the sensitive areas. Secure User Mode If Secure User Mode is activated (see "Secure user Mode (R&S FSWP-K33)" on page 8), firmware updates cannot be performed. In this case, deactivate the secure user mode for the duration of the update. Via the USB port The R&S FSWP is equipped with USB ports as standard equipment. The instrument firmware update can be performed directly from the USB stick. The USB stick can likewise hold or transport user data back-ups to an approved storage medium. As described in Special Considerations for USB Ports, users can disable the capability of the USB ports to save data (set to "read only"). For users that have not elected to disable the USB ports for writing data, a memory stick can be used to backup user data. Via the LAN interface The R&S FSWP is equipped with a LAN interface as standard equipment. A user can transport the firmware update into the secure area via a CD or another medium that meets the security requirements. The update can then be placed on a system on the LAN within the secure area. The R&S FSWP can be updated directly from the LAN. The LAN can likewise be used to backup user data to an approved storage medium. 11

Special Considerations for USB Ports 8 Special Considerations for USB Ports USB ports can pose a security threat in high-security locations. Generally, this threat comes from small USB pen drives (also known as memory sticks, key drives, etc.) which can be very easily concealed, yet can quickly read or write several GBytes of data. Disable USB Ports for Writing User Data The R&S FSWP can be updated with the USB Write Protection Utility to disable the write capability on any USB port for storage devices. This utility is available from the R&S FSWP product web site without any charge. To disable the write capability copy the utility software to the R&S FSWP and run it once. After reboot of the instrument the write capability on any USB memory device is disabled. 12