Magnetic proximity switches



Similar documents
Capacitive sensors. Versatile, contactless, durable Edition 2012/2013

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Inductive sensor NI10-M18-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Inductive sensors. Compact, fast, reliable. Edition 2013

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Magnetic Proximity Switches Series CST - CSV and CSH

Inductive Proximity Sensors

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Capacitive Prox E2K-X

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Application book Material Handling: forklifts. Inductive Sensors. Proximity Sensor

How To Use A Flowmeter

MPLM1630 MPLM2535 MPLM3240

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical Data. Dimensions

MPPM1606 MPPM2508 MPPM3210

Proximity Switches RS (Reed Switch)

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Safety at a high level!

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Cable Plug acc. to DIN EN , Form A

96 Variants. The GlobalProx range increases in popularity. 12 PNP Normally-open 12 PNP Normally-closed 12 NPN Normally-open 12 NPN Normally-closed

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

MIN Q SERIES MICRO-PROXIMITY SENSOR DC 3-WIRE TYPE

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Fast, reliable, ultra-precise. My-Com precision switches.

Shunt lock function 3066

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical Data. Dimensions

Proportional pressure regulators VPPE

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Turbine Flow Sensor Series VTR

Laserlyte-Flex Alignment System

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Color Mark Sensor with Red or Green LED E3S-VS

Contents. Document information

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Description. Dimensions. Features. precision works better

Electronic Pressure Switch EDS 300

Differential-Hall-Effect based Sensors Series A5S Overview

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

3-Component Measuring System

How To Make An Ultrasonic Sensor

System 8. ü ( System 8

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Differential-Hall-Effect based Sensors Series A5S

Conductive Level Switch FK 2 Technical Data:

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Electrical connection

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

intelligent solutions

TECHNICAL DATASHEET Incremental Encoder RI 58-H

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

CONEC SnapLock. 1 Introduction

QR12 (1.22 ) Diameter Optical Encoder

Series 6000 Torque measured metal bellow coupling

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Rotary actuators Rotary wing drives Series RAK. Brochure

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

Series 7500 Torque Sensor

DCP Fan Controller. Version 01/2009. The engineer s choice

W150: Miniature photoelectric switch series with completely integrated electronics

MULTI-BEAM LS10 Light Screen System

Cylindrical Proximity Sensor

400 Series - Mini USB Buccaneer

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

HERZ-Thermal Actuators

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Single sub-base valve

BITMAIN. APW PSU Series User Guide

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

How To Power A Schen

Combi B Alarm box. Mounting instructions

4 Posiflow Proportional Solenoid Valves

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Givare NC-SRS 280 och 880

How To Drive A Compact Serie 1

G1/4 Q8. Standard with biased position

LED...A Q Series Sealed High-Intensity

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja tel: Clamps Clamping devices

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Transcription:

Magnetic proximity switches Magnetic proximity switches Overview Page 38 Functional principle and installation Page 39 Cylindrical designs Page 41 Rectangular designs Page 42 37

Kurzübersicht Magnetoresistive Näherungsschalter Magnetic proximity switch Overview product family MFRM 08 MFFM 08 MFVM 08 mounting shielded shielded shielded dimension 8 mm 8 mm 8 mm housing length 30 mm 30 mm 30 mm NPN PNP cable PUR, 2 m housing material stainless steel brass nickel plated aluminum Magnetic proximity switch Overview Page 41 42 43 38

Magnetic proximity switches Functional principle and installation Sensor Magnetoresistive proximity switches detect the magnetic fields of permanent magnets. Depending on size and material of the deployed permanent magnet, the sensors provide different switching distance capabilities. Permanent magnet Trigger stage Functional principle Magnetoresistive element Output amplifier The magnetoresistive element is made of a specialized material which will only respond to magnetic fields, such as generated by a permanent magnet, by ting a digital signal. Capable of detecting even very weak magnetic fields, the material is about ten times more sensitive than a Hall element and thus allows for substantially extended sensing distances. Magnetoresistive proximity switches are omnipolar and therefore capable of detecting both north and southpole of the permanent magnet. Functional principle and installation Detection through tank walls The sensor can detect magnetic fields through non-ferromagnetic materials. This is particularly useful if sensor or permanent magnet require protected or isolated mounting, or when being separated from each other by a tank wall. Permanent magnet Installation Shielded (flush) installation Magnetoresistive proximity switches are conceived for shielded (flush) installation, meaning the being plain to the carrier surface. The carrier material must be non-ferromagnetic. Shielded installation in a ferromagnetic material will reduce the sensing distance by up to 25%, unshielded or non-flush installation ( protruding by its diameter from the ferromagnetic carrier surface) will enhance the sensing distance by up to 25%. Sensor Sensor Non-ferromagnetic material Non-ferromagnetic carrier material Magnetic proximity switches 2. 39039

Magnetic proximity switches Functional principle and installation Functional principle and installation Permanent magnet Alloy Permanent magnet Alignment Permanent magnet Mounting The switching distance of a magnetic sensor relates to the magnet deployed. Not only size but also alloy of the permanent magnet play a decisive role. The higher the energy product of the magnetic alloy in kjm³, the stronger the magnetic field and hence the more extended the switching distance. By principle, magnetoresistive proximity switches are polarity neutral, i.e. the sensor will detect both north and southpole of the permanent magnet. It is recommended to always attach the permanent magnet with one pole in alignment to the sensor to ensure reliable detection. The way a permanent magnet is mounted plays a crucial role in the sensing distance. When attached to a non-ferromagnetic carrier, the influence on the assured sensing distance will be nearly not noticeable. However, a permanent magnet mounted unshielded on a ferromagnetic carrier will enhance the switching distance by up to 25%. Attached flush or shielded to a ferromagnetic carrier, the switching distance will be reduced by up to 40% (always related to the assured sensing distance). If the permanent magnet is to be screwed on, always use non-ferromagnetic screws (e.g. stainless steel). 300 150 BH max. (kj/m 3 ) 0 Neodyminium-Iron-Boron Samarium-Cobalt Hard ferrite SrFe 280 190 30 Sensor Permanent magnet Assured sensing distance Sa Magnetic proximity switches Attached to non-ferromagnetic carrier Attached to ferromagnetic carrier Sensor Permanent magnet Carrier material non-ferromagnetic Carrier material ferromagnetic Shielded installation on ferromagnetic carrier Carrier material ferromagnetic 40

Magnetic proximity switch MFRM 08 Cylindrical M8 Detects permanent magnets on long distances Polarity independent High switching frequencies general data dimension drawing magneto-resistive assured sensing distance Sa 60 mm indicator red M8 x 1 mounting shielded nominal operation point hysteresis 2,5 mt 2... 20 % of Sr SW 13 30 repeat accuracy electrical data switching frequency voltage supply range +Vs current consumption max. voltage drop Vd current short circuit protection reverse polarity protection mechanical data < 1 % of Sr < 5 khz 10... 3DC 20 ma < 3 VDC < 150 ma yes yes, Vs to GND connection diagrams NPN PNP Cylindrical M8 MFRM 08 material () PBT cylindrical threaded dimension 8 mm housing material stainless steel housing length 30 mm connection s cable PUR, 2 m ambient conditions operating temperature -25... +75 C mounting accessories 10151719 Sensofix series 08 11052882 Permanent magnet MMRS AA02X02 11052883 Permanent magnet MMRN AA06X05 11053959 Permanent magnet MMRH BA31X15 for details: see accessories section protection class IP 67 remarks assured sensing distance in conjunction with permanent magnet 11053959 (available as an accessory) order reference MFRM 08N1524/PL MFRM 08N3524/PL MFRM 08P1524/PL MFRM 08P3524/PL circuit NPN make function (NO) NPN break function (NC) PNP make function (NO) PNP break function (NC) Magnetic proximity switch 41

Magnetic proximity switch MFFM 08 Rectangular Detects permanent magnets on long distances Polarity independent High switching frequencies general data dimension drawing magneto-resistive assured sensing distance Sa 60 mm indicator mounting red shielded 8 8 3 nominal operation point 2,5 mt 5 10 Rectangular hysteresis repeat accuracy electrical data switching frequency voltage supply range +Vs 2... 20 % of Sr < 1 % of Sr < 5 khz 10... 3DC 30 M3 10 MFFM 08 current consumption max. voltage drop Vd current short circuit protection reverse polarity protection mechanical data 20 ma < 3 VDC < 150 ma yes yes, Vs to GND connection diagrams NPN PNP material () PBT rectangular dimension housing material 8 mm brass nickel plated mounting accessories 11052882 Permanent magnet MMRS AA02X02 housing length 30 mm 11052883 Permanent magnet MMRN AA06X05 connection s ambient conditions cable PUR, 2 m 11053959 Permanent magnet MMRH BA31X15 for details: see accessories section operating temperature -25... +75 C protection class IP 67 remarks assured sensing distance in conjunction with permanent magnet 11053959 (available as an accessory) Magnetic proximity switch order reference MFFM 08N1424/PL MFFM 08N3424/PL MFFM 08P1424/PL MFFM 08P3424/PL circuit NPN make function (NO) NPN break function (NC) PNP make function (NO) PNP break function (NC) 42

Magnetic proximity switch MFVM 08 Rectangular, with V-slot Fully enclosed full metal housing Housing for mounting directly on cylinders Detects permanent magnets on long distances general data dimension drawing version magneto-resistive full metal 12 8 assured sensing distance Sa 60 mm 5 indicator red 30 mounting shielded 10 nominal operation point hysteresis repeat accuracy electrical data switching frequency voltage supply range +Vs current consumption max. voltage drop Vd current short circuit protection reverse polarity protection mechanical data 2,5 mt 2... 20 % of Sr < 1 % of Sr < 5 khz 10... 3DC 20 ma < 3 VDC < 150 ma yes yes, Vs to GND 139 1,5 connection diagrams NPN PNP Rectangular, with V-slot MFVM 08 rectangular dimension housing material housing length connection s ambient conditions 8 mm aluminum 30 mm cable PUR, 2 m mounting accessories 11052882 Permanent magnet MMRS AA02X02 11052883 Permanent magnet MMRN AA06X05 11053959 Permanent magnet MMRH BA31X15 for details: see accessories section operating temperature -25... +75 C protection class IP 67 remarks assured sensing distance in conjunction with permanent magnet 11053959 (available as an accessory) order reference MFVM 08N1424/PL MFVM 08N3424/PL MFVM 08P1424/PL MFVM 08P3424/PL circuit NPN make function (NO) NPN break function (NC) PNP make function (NO) PNP break function (NC) Magnetic proximity switch 43

44

Overview Page 46 Functional principle and installation Page 47 C-slot sensors Page 49 T-slot sensors Page 51 45

Kurzübersicht Magnetische ylindersensoren Overview product family MCK 03 MCK 03 MTK 06 MTK 06 MTK 06 version C-slots C-slots T-slots T-slots T-slots nominal operation point 4 mt 4 mt 4 mt 2 mt 4 mt width / diameter 3,7 mm 3,7 mm 6,2 mm 6,5 mm 6,2 mm depth 23 mm 9 mm 31 mm 21 mm 31,5 mm short circuit protection yes yes yes NPN PNP cable PUR 3 pin, 2,5 m cable PUR 3 pin, 5 m Overview flylead connector PUR M8, L=300 mm housing material PA66 PA66 PA66 PA66 PA66 Page 49 50 51 52 53 46

Functional principle and installation The sensor are deployed to register the positions of pistons in pneumatic cylinders. They detect the piston-carried permanent magnet through the cylinder wall utilizing the magnetoresistive principle. Permanent magnet Functional principle Magnetoresistive element The piston inside the cylinder carries a permanent magnet which builds a magnetic field to penetrate all non-ferromagnetic materials. The sensor is tripped when detecting the magnetic field. To mount the sensor it is introduced in the slot provided at the cylinder and secured. By aid of clamps and bolts available as accessories, cylinder sensors can be attached to all conventional cylinders. Output amplifier Trigger stage Sensor element Permanent magnet Functional principle and installation Adjustment The magnetic fields of the permanent magnets inside the cylinders scatter and will differ in their specifications according to the cylinder. Thus, it is not possible to specifiy the exact tripping point of the sensor. To ensure the cylinder sensor is placed in the proper position proceed as follows: 1) Get the piston into the required switching position 2) Move the cylinder sensor in the slot in opposite direction to step one* 3) After light up, withdraw the sensor a little to ensure reliable switching operation 4) Secure the sensor 5) Verify the switching point by aid of the 1) 2) 3) 4) *Round cylinders or Tie-Rod cylinders: First attach the sensor loosely to the cylinder using a clamp or bolt. 5) 2. 47047

Functional principle and installation Mounting Cylinders with slot Conventional cylinders provide standard T- or C-slots. The cylinder sensors are simply introduced in the slot and secured either by using a grub screw or by a metal plate which will lock in the slot after having tightened the fastening screw. T-slot C-slot Dovetail slot Functional pricinple and installation Mounting Round cylinders or cylinders with tension rods Some commonly deployed round cylinders or cylinders with tension rods may not provide a slot for sensor mount. In this case, the C- or T-slot sensors will be attached using clamps or bolts. Tie-Rod cylinders Round cylinders Mounting Special slots C-slot sensors can also be mounted in T- slots by using the adaptor from an accessory kit. Adaptors for special slots such as dovetail are also available. T-slot Dovetail slot 48

MCK 03 C-slot C-slot housing For all common cylinder s Wear-free general data magneto-resistive version C-slots nominal operation point 4 mt difference ON-OFF 0,5... 1,5 mt indicator yellow electrical data switching frequency < 200 khz response time / release time < 0,0025 ms current < 200 ma voltage supply range +Vs 5... 3DC function normally open (NO) voltage drop Vd < 1 VDC reverse polarity protection yes short circuit protection yes mechanical data cable axial rectangular depth 23 mm width / diameter 3,7 mm height / length 4,6 mm housing material PA66 ambient conditions operating temperature -10... +70 C protection class IP 67 dimension drawings 23 3,7 4,6 2 3 12 connection diagrams NPN 23 3,7 4,6 PNP 2 3 12 M8 x 1 connectors and mating connectors ESG 32SH0200 Connector M8, 3 pin, straight, 2 m ESW 31SH0200 Connector M8, 3 pin, angular, 2 m additional cable connectors and field wireable connectors: see accessories mounting accessories MA 01 Adapter set for C- and T-slot sensors in standard slots for details: see accessories section L ca. 39 C-slot MCK 03 order reference circuit connection s MCK 03N1011 NPN cable PUR 3 pin, 2,5 m MCK 03N1011/KS35D NPN flylead connector PUR M8, L=300 mm MCK 03P1011 PNP cable PUR 3 pin, 2,5 m MCK 03P1011/0500 PNP cable PUR 3 pin, 5 m MCK 03P1011/KS35D PNP flylead connector PUR M8, L=300 mm 49

MCK 03 C-slot C-slot housing Especially short housing Wear-free C-slot MCK 03 general data magneto-resistive version C-slots nominal operation point 4 mt difference ON-OFF 0,5... 1,5 mt indicator yellow electrical data switching frequency < 200 khz response time / release time < 0,0025 ms current < 200 ma voltage supply range +Vs 5... 3DC function normally open (NO) voltage drop Vd < 1 VDC reverse polarity protection yes mechanical data cable lateral rectangular depth 9 mm width / diameter 3,7 mm height / length 19,5 mm housing material PA66 ambient conditions operating temperature -10... +70 C protection class IP 67 dimension drawings 5 4 L ca. 39 L order reference circuit connection s MCK 03N1012 NPN cable PUR 3 pin, 2,5 m MCK 03N1012/KS35D NPN flylead connector PUR M8, L=300 mm MCK 03P1012 PNP cable PUR 3 pin, 2,5 m MCK 03P1012/KS35D PNP flylead connector PUR M8, L=300 mm connection diagrams NPN 9 19,5 3,7 2 3 M8 x 1 5 PNP connectors and mating connectors ESG 32SH0200 Connector M8, 3 pin, straight, 2 m ESW 31SH0200 Connector M8, 3 pin, angular, 2 m additional cable connectors and field wireable connectors: see accessories 4 9 19,5 3,7 2 3 50

MTK 06 T-slot T-slot housing For all common cylinder s Wear-free general data magneto-resistive version T-slots nominal operation point 4 mt difference ON-OFF 0,5... 1,5 mt indicator yellow electrical data switching frequency < 200 khz response time / release time < 0,0025 ms current < 200 ma voltage supply range +Vs 5... 3DC function normally open (NO) voltage drop Vd < 1 VDC reverse polarity protection yes short circuit protection yes mechanical data cable axial rectangular depth 31 mm width / diameter 6,2 mm height / length 4,3 mm housing material PA66 ambient conditions operating temperature -10... +70 C protection class IP 67 dimension drawings 31 6,2 2,1 5 9 connection diagrams NPN 4,3 31 6,2 PNP 2,1 5 M8 x 1 connectors and mating connectors ESG 32SH0200 Connector M8, 3 pin, straight, 2 m ESW 31SH0200 Connector M8, 3 pin, angular, 2 m additional cable connectors and field wireable connectors: see accessories mounting accessories MA 01 Adapter set for C- and T-slot sensors in standard slots for details: see accessories section 9 4,3 L ca. 39 T-slot MTK 06 order reference circuit connection s MTK 06N1011 NPN cable PUR 3 pin, 2,5 m MTK 06N1011/KS35D NPN flylead connector PUR M8, L=300 mm MTK 06P1011 PNP cable PUR 3 pin, 2,5 m MTK 06P1011/0500 PNP cable PUR 3 pin, 5 m MTK 06P1011/KS35D PNP flylead connector PUR M8, L=300 mm 51

MTK 06 T-slot T-slot housing Especially short housing Wear-free T-slot MTK 06 general data magneto-resistive version T-slots nominal operation point 2 mt difference ON-OFF 0,5... 1,5 mt indicator yellow electrical data switching frequency < 200 khz response time / release time < 0,0025 ms current < 200 ma voltage supply range +Vs 5... 3DC function normally open (NO) voltage drop Vd < 1 VDC reverse polarity protection yes mechanical data cable lateral rectangular depth 21 mm width / diameter 6,5 mm height / length 9,4 mm housing material PA66 ambient conditions operating temperature -10... +70 C protection class IP 67 dimension drawings 21 16 9,4 6,5 2,9 5 3 connection diagrams NPN 12,8 21 16 9,4 PNP 6,5 2,9 5 3 L L 12,8 ca. 39 connectors and mating connectors ESG 32SH0200 Connector M8, 3 pin, straight, 2 m ESW 31SH0200 Connector M8, 3 pin, angular, 2 m additional cable connectors and field wireable connectors: see accessories mounting accessories MA 01 Adapter set for C- and T-slot sensors in standard slots for details: see accessories section M8 x 1 order reference circuit connection s MTK 06N1012 NPN cable PUR 3 pin, 2,5 m MTK 06N1012/KS35D NPN flylead connector PUR M8, L=300 mm MTK 06P1012 PNP cable PUR 3 pin, 2,5 m MTK 06P1012/KS35D PNP flylead connector PUR M8, L=300 mm 52

MTK 06 T-slot T-slot housing Set into T-slot from the top Wear-free general data magneto-resistive version T-slots nominal operation point 4 mt difference ON-OFF 0,5... 1,5 mt indicator yellow electrical data switching frequency < 200 khz response time / release time < 0,0025 ms current < 200 ma voltage supply range +Vs 5... 3DC function normally open (NO) voltage drop Vd < 1 VDC reverse polarity protection yes short circuit protection yes mechanical data cable axial rectangular depth 31,5 mm width / diameter 6,2 mm height / length 4,5 mm housing material PA66 ambient conditions operating temperature -10... +70 C protection class IP 67 dimension drawings 31,5 6,19 2,4 9 connection diagrams NPN 4,5 31,5 6,19 PNP 2,4 9 M8 x 1 connectors and mating connectors ESG 32SH0200 Connector M8, 3 pin, straight, 2 m ESW 31SH0200 Connector M8, 3 pin, angular, 2 m additional cable connectors and field wireable connectors: see accessories mounting accessories MA 01 Adapter set for C- and T-slot sensors in standard slots for details: see accessories section 4,5 L ca. 39 T-slot MTK 06 order reference circuit connection s MTK 06N1013 NPN cable PUR 3 pin, 2,5 m MTK 06N1013/KS35D NPN flylead connector PUR M8, L=300 mm MTK 06P1013 PNP cable PUR 3 pin, 2,5 m MTK 06P1013/0500 PNP cable PUR 3 pin, 5 m MTK 06P1013/KS35D PNP flylead connector PUR M8, L=300 mm 53

54