Handheld portable appliance testers



Similar documents
PAT120, PAT150 and PAT150R Handheld portable appliance testers

LOW VOLTAGE TEST LEADS

TORKEL 820 Battery Load Unit

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

DET3 Contractor Series

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

DET3 and 4 Contractor Series Earth/Ground Resistance Testers

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

1650 Series Multifunction Installation Testers

EGSTON Standard E2xFxWx 12W

Agilent 4339B/4349B High Resistance Meters

FRAX 150 Sweep Frequency Response Analyzer

User Guide. Model Insulation Tester / Megohmmeter

Agilent 87421A/87422A Power Supply

MEGGER Insulation & Low Resistance Tester

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

PAT400 Series. Portable Appliance Testers. User Manual

rigel 288 Electrical Medical Safety Analyser Key Features Applications

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

User Manual for CH-PFC76810

Multi-Function Ground

OUTPUT CABLE CONNECTIONS:

PAT Tester Printers and Barcode Scanners

Hand-held thermometer Model CTH7000

Manual Ranging MultiMeter

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

Duct Humidity Transmitter

User Guide. 4 wire Earth Resistance Tester Model GRT300

MIT510/2, MIT520/2 and MIT1020/2

AutoRanging Digital MultiMeter

DC Electronic Loads 8500 series

Fluke 1650B Series Multifunction Installation Testers

M LTW 300 Series Earth Loop testers User Guide

User s Manual Before using the inverter, you need to read and save the safety instructions.

ST Series POWER SUPPLIES USER INSTRUCTIONS

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

BB800 Off-Grid Solar System

Agilent 4338B Milliohm Meter

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Digital input modules

10 Multimeter. Users Manual

EurotestXE MI 3102H BT MI 3102 BT Instruction manual Version 1.1, Code no

Emergency lighting units EM powerled

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Digital Transformer Ratiometer DTR Model 8500

How To Use A Power Supply Unit (Upu)

5000V Graphical Megohmmeter Model 5070

FIRST STOP SAFETY 1 PAT-IT. Portable Appliance Tester. User Manual. Issue 1.6

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Insulation resistance testing. A complete solution for every person.

Product Information Sheet UH28CS-12kV Hi Pot Tester

Users Manual. Appliance Tester

User's Guide. True RMS Industrial Multimeter

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

1. SAFETY INFORMATION

Quick Connect. quick - simple - efficient.

Appliance Multitester C.A 6155

Current Monitoring Kit

Thyristor-controlled power supplies and battery chargers

Givare NC-SRS 280 och 880

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Integrating Sound Level Meter and Datalogger

Multi-Range Programmable DC Power Supplies 9115 Series

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Cable Identifier Reliable cable selection for energised and de-energised cables

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

USB-500 Series Low-Cost Data Loggers and Accessories

DET3 Contractor Series 3-Terminal Earth/Ground Resistance Testers

Data Sheet. Portable Appliance Testing

Guidance for upgrading to GB (IEC : 2005, MOD)

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

Operating Manual UWAPS-TINY Series

4-Channel Thermometer / Datalogger

MAJORSINE Power Inverter

How To Use A Cdm250 Digital Multimeter

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

User s Manual AURORA 1.2K/2.2K

1.44 kw Programmable DC Power Supplies XLN Series

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Drayton Digistat +2RF/+3RF

Charging connections for electric vehicles

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

Voltage Regulator SPAU 341 C. Product Guide

Mini Power Bank and Charger

Agilent 8762/3/4A,B,C Coaxial Switches

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Advanced Systems Tester 900AST

Electrical Safety Tester Verification

T Substation Maintenance and Commissioning Test Equipment

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

ACL 395 Resistivity Meter

Current Monitoring Kit QUICK START GUIDE

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

DC POWER SUPPLY ALIMENTATION C.C.

Transcription:

PAT100 SERIES Handheld portable appliance testers PAT100 SERIES Handheld portable appliance testers Simple Tick/Cross, pass/fail indication plus measurement Battery powered with rechargeable options Includes 250 V Insulation and Leakage testing for safe IT testing and surge protected devices Testing portable and fixed electrical equipment 10 ma and 30 ma Portable RCD lead testing (PAT150) Adjustable PASS test limits (PAT150) Substitute and Mains powered leakage testing (PAT150) Tough, rubber armoured with built-in front cover, hardened, scratch proof display window Description The PAT100 series of hand help portable appliance testers enable simple, fast safety testing in all environments including offices, shops and business units. It is ideally suited to training organisations with a very short learning curve and tough, reliable functionality. With rubber armoured cases and fitted with hardened, scratch proof glass, the PAT100s are exceptionally tough instruments. Battery powered operation makes the PAT100s perfect for those locations where an electrical supply is not available, inconvenient or unsafe, especially building sites and warehouses. The PAT100 series conforms to all and European requirements for electrical safety testing. Test groups Test groups enable the correct sequence of tests to be performed automatically with minimum intervention by the user. This keeps testing simple, reduces test times to a minimum and helps to prevent testing errors. PAT120: The PAT120 model has test groups available for Class I, Class II and Extension/Power leads. Fixed PASS limits. Insulation testing at 500 V (default) or 250 V can be selected at the start of the test. Leakage testing uses a Substitute Leakage also known as the Alternative method to remove the need for a mains supply during test. The PAT150: The PAT150 has additional tests available for testing portable RCDs (PRCDs) of 10 ma and 30 ma. Separate tests for Continuity, Insulation, mains powered leakage testing and SELV measurements can be made using the Quick Test (QT) button. Test group pass limits and test duration can be configured by the user. Bond lead resistance can be nulled to reduce measurement errors. Live circuit measurement is available for testing the mains supply and socket polarity or electrical circuit voltage to 300 V ac. Can be used for testing fixed appliances. Continuity test Used for measuring the proper bonding of all metal parts of a class I device to the protective conductor. Tests are performed at 200 ma dc in both polarities to be compliant with international and regulation or recommendations. This test is safe to perform on equipment where higher test currents could cause damage. Insulation testing Used for measuring the separation of conductive parts or conductors from earth. This test is usually performed at 500 V dc. The PAT100 series maintain the necessary test voltage down to 0.5 Mohms.

An additional 250 V dc insulation test is available on all models for use on IT equipment, on devices or extension leads that are fitted with surge protection, or simply where it may be considered undesirable to use a 500 V test. Substitute leakage testing Substitute leakage testing enables the measurements of AC leakage currents, which could differ significantly from the DC Insulation test results. Substitute leakage testing is performed at less than 40 V ac. and does not require a mains supply. Substitute leakage testing is used for measuring protective conductor current and touch current, in addition to an insulation test, or where it is considered an insulation test may damage equipment. The Substitute leakage test will not operate equipment and so can be used where the operation of the equipment under test is undesirable. Portable RCD testing (PRCD) Portable RCDs can be tested using the PAT150. There is no need to find a non-rcd protected supply as the PAT150 will not trip external RCDs. Both 10 ma and 30 ma RCDs can be tested both for disconnection times and the manual test button function. Separated Extra Low Voltage (SELV) supplies SELV supplies should be tested to ensure the output voltage does not exceed maximum limits as defined in the international regulations for Extra Low voltage systems. The PAT150 permits up to 50 V ac measurement, with a PASS or fail indication for SELV. Differential Leakage (Protective Conductor Current), Touch Current & operational test The PAT150 includes the facility for mains powered leakage test. This test has the benefit that equipment under test will function during the test sequence. Battery life The PAT120 & PAT150 operates from AA Alkaline or NiMH cells. Battery life is typically 4 days, based on 120 assets per day. The PAT150R can be re-charged with NiMH batteries fitted. SPECIFICATIONS ENVIRONMENTAL CONDITION: Operating ambient 20 C Humidity CONTINUITY TEST Test current Continuity accuracy Nominal humidity Resistance resolution 0.01 to 19.99Ω Continuity test nulling up to 9.99 Ω Compliance Voltage: +4V dc 0 % /+10 % (open circuit) Bi-directional +200mA -0% + 50mA (into 2Ω load) Resistance: ± 5% ± 3 digits (0 to 19.99 Ω) 10 mω Test time User selectable from 2 sec to 20 sec or selected during test to 180sec INSULATION TEST Insulation test 250V dc 0 % /+25 % open circuit 500V dc 0 % /+25 % open circuit 500V 0% dc across 0.5 MΩ load Short circuit/charge current < 2mA dc Insulation accuracy ±3% ±10 digits (0 to 19.99 MΩ) 0.01 MΩ 0.10 MΩ to 99.99 MΩ Test duration User selectable from 2 sec to 20 sec or selected during test to 180sec SUBSTITUTE LEAKAGE TEST Leakage current Accuracy ± 5% ± 3 digits Nominal mains frequency 50Hz < 50V ac 0.01mA 0.10 to 19.99mA seconds Reading corrected to 230V ac. DIFFERENTIAL LEAKAGE CURRENT Nominal supply voltage 230 V ac Nominal mains frequency 50 Hz Test accuracy ±5% ± 3 digits 0.01 ma 0.10 to 19.99 ma seconds 2

TOUCH CURRENT TEST Test accuracy Nominal mains 230 V ac Nominal mains 50 Hz ± 5% ± 3 digits 0.01 ma 0.10 to 3.99 ma sec SELV DEVICE TEST 0 to 300 V ac Measurement accuracy ± 3% ± 3 digits 0.1 V ac 0.1 to 300 V ac EXTENSION LEAD TEST Test includes Insulation and Bond tests. 5V Polarity Lead OK Live/neutral shorted Live/neutral reversed Live/neutral open circuit PORTABLE RCD TEST Nominal mains 230 V 50Hz Test current accuracy +2% to +8% (1 x I, 5 x I) Trip time accuracy ±1% ± 1ms Trip time resolution 0.01ms 0 to 200ms (1 x I) 0 to 40ms (5 x I) MAINS SUPPLY TEST Frequency measurement 50 Hz range 40 to 300V ac Accuracy ± 3% ± 3 digits 0.1Vac 40 to 300V ac CIRCUIT TEST (Carried out automatically, not available to user) 5V Nominal Mains 50 Hz Test current < 100mA short circuit EMC Design to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005. Fuse (user replaceable) variants has mains plug fuse One F 100 ma 250 V 5 x 20 mm HBC fuse. ENVIRONMENTAL Operating temperature 0 C to +40 C range Storage temperature range -20 C to +60 C Humidity 90%RH @ +10 C +30 C 75%RH @ +30 C to +40 C Maximum altitude 2,000m to full safety spec. IP rating IP40 (with front cover closed) MECHANICAL BATTERIES Battery life 3 days based on 120 tests/ day using 2000 mah Alkaline batteries Battery type Supply voltage 12 Vdc (Alkaline AA LR6) 9.6 Vdc (NiMH AA LR6) WEIGHT PAT120 (instrument only): 1150 g (40.4 oz) Shipping weight: 2370g (83.6 oz) PAT150 (instrument only): 1300 g (45.8 oz) Shipping weight: 2795g (98.6 oz) PAT150R (instrument only): 1300 g (45.8 oz) Shipping weight: 2975g (104.9 oz) DIMENSIONS Dimensions (instrument and case) Dimensions (instrument and packaging) 203mm (L) x 148mm (W) x 78mm (H) (8 x 5.7 x 3.2 inches) 456mm(L) x 178mm (W) x 89mm (H) (18 x 7.1 x 3.5 inches) Safety Instrument designed to IEC 61010-1: 2012 Test leads designed to IEC 61010-031: 2005 300 volts to Earth Category II Mains fuse protection to 250 volts rms ac 3

Product selection table: Germany Dutch Spain Belgium Belgium Poland Switzerland Australia New-Zealand DE DE EU EU FR FR CH CH AU AU Connector Interfaces Mains Test Socket BS1363 CEE 7/4 Schuko CEE 7/5 French Swiss SEV 1011 AS/NZS 3112 (15A) Power Supply AA alkaline/nimh n n n n n Rechargeable (PAT150R)* Testing Protective n n n n n Earth Resistance 250 V insulatio 500 V insulatio n Cable test n n n n n Live protective conductor current Live touch current Substitute leakage n n n n n Functional test (part of Live leakage test) 10 ma PRCD 30 ma PRCD SELV voltage Lead resistance nulling Fuse test Function Keys Class 1 n n n n n Class 2 n n n n n Lead/cord n n n n n PRCD Single test LCD Backlight n n n n n Setup On/Off n n n n n Standard Accessories 4mm plug lead probe + croc clip 1 2 1 2 1 2 1 2 1 2 2 Extension lead adaptor AC Charger Adaptor BS1363 IEC 83:1975 Std C 1b SN SEV 1011 AS/NZS 3112:2000 Mains Supply Cord Carry case n n n n n Note: The rechargeable version of the PAT150 has the identifier (R). 4

ORDERING INFORMATION Description order Code DescriptionO order Code CH PORTABLE APPLIANCE TESTER 1003-074 Included accessories for PAT120 DE PORTABLE APPLIANCE TESTER 1003-066 Extension lead adaptor BS1363 1001-234 DE-RS PORTABLE APPLIANCE TESTER 1003-067 Continuity/earth bond lead 1001-233 EU PORTABLE APPLIANCE TESTER 1003-070 Carry case 1005-075 FR PORTABLE APPLIANCE TESTER 1003-072 PAT100 range ~ Included accessories for PAT150 PORTABLE APPLIANCE TESTER 1003-062 Continuity/earth bond lead 1001-233 -RS PORTABLE APPLIANCE TESTER 1003-063 SELV/mains voltage test lead Red x1 1005-077 AU PORTABLE APPLIANCE TESTER 1003-077 Extension lead adaptor BS1363 1001-234 CH PORTABLE APPLIANCE TESTER 1003-075 Extension lead adaptor Schuko 1001-235 DE PORTABLE APPLIANCE TESTER 1003-068 Extension lead adaptor Australia 1001-236 DE-RS PORTABLE APPLIANCE TESTER 1003-069 Extension lead adaptor Switzerland 1005-081 EU PORTABLE APPLIANCE TESTER 1003-071 Mains plug test lead 6231-601 FR PORTABLE APPLIANCE TESTER 1003-073 Mains plug test lead (CEE 7/7) 1005-078 PORTABLE APPLIANCE TESTER 1003-064 Mains plug test lead (AS/NZS 3112) 1005-080 -RS PORTABLE APPLIANCE TESTER 1003-065 Carry case 1005-075 PAT150R-AU PORTABLE APPLIANCE TESTER 1003-435 PAT150R-CH PORTABLE APPLIANCE TESTER 1003-434 Included accessories for PAT150R PAT150R-DE PORTABLE APPLIANCE TESTER 1003-430 AC Mains charger multi-country 1003-436 PAT150R-DE-RS PORTABLE APPLIANCE TESTER 1003-431 Optional accessories PAT150R-EU PORTABLE APPLIANCE TESTER 1003-432 Plug adaptor IEC C6 - C13 1001-232 PAT150R-FR PORTABLE APPLIANCE TESTER 1003-433 110 V Extension lead adaptor 6220-639 PAT150R- PORTABLE APPLIANCE TESTER 1003-428 415 V adaptor lead (4-pin) to BS1363 (16 A) 1000-767 PAT150R--RS PORTABLE APPLIANCE TESTER 1003-429 415 V adaptor lead (5 pin) to BS1363 (16 A) 1000-770 Archcliffe Road Dover CT17 9EN England T +44 (0) 1304 502101 F +44 (0) 1304 207342 sales@megger.com UNITED STATES 4271 Bronze Way Dallas TX 75237-1019 USA T 800 723 2861 (USA only) T +1 214 333 3201 F +1 214 331 7399 USsales@megger.com OTHER TECHNICAL SALES OFFICES Valley Forge USA, College Station USA, Sydney AUSTRALIA, Danderyd SWEDEN, Ontario CANADA, Trappes FRANCE, Oberursel GERMANY, Aargau SWITZERLAND, Kingdom of BAHRAIN, Mumbai INDIA, Johannesburg SOUTH AFRICA, Chonburi THAILAND CERTIFICATION ISO Registered to ISO 9001:2004 Cert. no. Q 09290 Registered to ISO 14001-2000 Cert. no. EMS 61597 PAT100_DS_en_V01 www.megger.com Megger is a registered trademark 5