Know what is going on inside the mold.



Similar documents
Computer Creep System

Portable digital microprocessor thermometers with interchangeable probes

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

Multi-Function Ground

Application Unit, MDRC AB/S 1.1, GH Q R0111

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

CVe Monitor V2. Ultimate flexibility in tracking mold activity

OnDemand Version 1.7. Installation Manual and User s Guide. AST Technology. Sophienstrasse Herford Germany

SATA/eSATA II PCI & PCI-E Card & CardBus

FleetLink Fuel Control System

OZW30. Central Unit SYNERGYR

SIMATIC Sensors. The new software SIMATIC RF-MANAGER Simple management of RFID systems. Brochure April Answers for industry.

4-Channel Thermometer / Datalogger

DIGICLIENT 8.0 Remote Agent Software

Operating Instructions

ASERIES ATM Access Management System

JOFRACAL Temperature and Pressure Calibration Software

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Engineering and service software For KNX and LPB plants

DataView DVTH Data Logger for Temperature and Humidity

USB-500/600 Series Low-Cost Data Loggers and Accessories

User's Guide Integrating Sound Level Datalogger Model

Technical Information

We reserve the right to make technical changes.

User's Guide. Integrating Sound Level Datalogger. Model Introduction

How do I monitor the ink levels on my EPSON Stylus printer using Windows 2000 or XP?

PRODUCT INFORMATION. SICK Remote Service Product and System Support. Secure remote monitoring for efficient service

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

XID 8300 Ethernet Status Monitor. Instruction Manual

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

IEEE /ZigBee USB Dongle

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

NTP Software Data Collection Agent Windows Version Installation Guide

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

MADRIX NEO Quick Start Guide & User Manual

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Infrarot-Bewegungsmelder IP44

HP Hardware Support Onsite 6-Hour Call-to-Repair Service HP Customer Support Contractual Service Package

ELM Security System Electronic Locking & Monitoring

The UPS for the highest security in industry and data centres

Data-logger evaluation software GSoft V2.8

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

New thermometers and accessories to grow your business

Heat Tracing is the use of an externally applied heat source to a pipeline to compensate for heat losses through the thermal insulation.

Measuring electric and magnetic fields

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

IntesisBox KNX LG Air Conditioning

Handheld LPC Data Retrieval Software for Windows. Operation Manual

How To Use Safety System Software (S3)

On-line Dissolved Gas Analysis

VENTIsupport Version 1

HYDRUS ULTRASONIC METER

PD 100A. Printing data system

Repeaters and Mimics Data Sheet

Copyrights 2010 Victron Energy B.V. All Rights Reserved

V2.7.x Installation on a Database Server Note: This document is to be used on a new database server installation.

Radio controlled, programmable radiator thermostat RA PLUS-w

2.24. Pump Controller 704. Data Sheet

Temperature & Humidity SMS Alert Controller

MONITORING PERFORMANCE IN WINDOWS 7

ADC SWATCH (v3.0) Switch Monitoring Software) User Manual)

LBP-1210 Laser Printer

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Operating instructions IV / 2007

Day / Night IR Color Camera User Manual V2.1.0

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Waveguide Access Point WGA631. Product Guide

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.

Using Integrated Lights-Out in a VMware ESX environment

Technical Bulletin. Teledyne PDS Clock Synchronization Considerations. Version 1.2

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

ACS-30-EU-EMDR-10-MOD

Customer Onboarding Guide. How to successfully set up your service 2-9 users

Communicate and view data from meters with one simple device

Remote Monitoring and REC 501 Control Unit Product Guide

SNMP Web Management. User s Manual For SNMP Web Card/Box

Digital input modules

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

DCS Data and communication server

ACR120 Technical Specifications version 2.9 November 2005

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

FaciliWorks. Desktop CMMS Software. Making Maintenance Manageable

Machine needle shut-off nozzle type-a

USB FLASH DRIVE. User s Manual 1. INTRODUCTION FEATURES SPECIFICATIONS PACKAGE CONTENTS SYSTEM REQUIREMENTS...

ViviCam 25 Digital Camera User s Manual

Transcription:

moldmind moldmind

moldmind : black box for injection mold Know what is going on inside the mold. Why is there still burned resin inside the mold? What is causing the production time to be exceeded? Is the number of completed cycles really accurate? Has the mold or a component been damaged due to an error made by the manufacturer or due to incorrect handling of the mold? Up to now, process controllability within the injection mold has been limited. Eliminating errors is a time-consuming procedure that frequently results in production delays. This, in turn, leads to a lengthy and drawn-out effort to find the source of the problem, determine who is at fault, and finally establish the validity of specific guarantee claims. moldmind : Never miss a thing. Black box devices have long been used successfully in aircraft and vehicles for recording events. With mold- MIND, you can now integrate a black box of your own into your injection mold to record vital process data. Using a PC, you can review and evaluate the collected data at any time. The original data, however, remains safely stored in the black box. Modification of the data is not possible. moldmind records and stores not only the actual number of shots and the cycle times (min./max.), but also the daily temperature peaks and downtime of the injection mold. Any removal of moldmind is also logged. This allows moldmind to provide a clear-cut picture of the facts in the event of a dispute while, at the same time, creating a database that can be utilized for production process optimization. moldmind is a tamper-proof instrument for mold owners, injection molders, and moldmakers that can be used to document and control key parameters in the production process. Benefits: Provides factual evidence in the event of a dispute Can be used for process optimization and quality control Enables the creation of a tool database Makes it possible to monitor maintenance intervals

Information provided directly on the injection mold moldmind display Direct information display. A liquid crystal display shows you both the total number of shots and the current status. Sources of error such as defective or incorrectly connected thermocouples are shown directly on the display. Also shown is information documenting any removal of moldmind as well as injection mold downtime. Status displays: Number of cycles Seconds PC connection Removal of moldmind Injection mold downtime Thermocouple 1 broken Thermocouple 2 broken Connection to PC / Notebook Reading out day-to-day data to PC / Notebook Recorded daily. Day-to-day data statistics provide you with current information about the parameter data collected so far that day. Thermal sensors are used to measure the temperature at up to two different points that can be specified individually. It is possible to measure the temperature of both the mold and the hot runner. Day-to-day data: Number of daily cycles and accumulated number of cycles completed since activation Minimum and maximum cycle time and time of day Operation hours, downtime hours, disassembly hours Maximum temperature and temperature duration as measured at two individually specifiable measuring points

Long-term statistics Temperatur profile: Identify irregularities quickly and effectively Seamless evaluation. The long-term statistics comprise all of the data gathered in the daily statistics. The data is maintained in an Excel table that can be used to create a variety of different diagrams for further analysis. This allows you to track down inconsistencies or possible sources of error quickly and effectively. Ensuring seamless process documentation makes it possible to lay the foundations for long-term process optimization. If multiple molds have been equipped with moldmind, the data from each mold can be consolidated into a single tool database. moldmind back: connection for two thermocouples Logging event data Unchangeable. moldmind is operated using a battery with a life corresponding to the average lifespan of an injection mold. No additional power sources are required. Relying solely on the power it obtains from its battery, moldmind records all configuration modifications and error messages occur- ring since activation and stores this information for use in its own event data statistics. Errors include e.g. thermocouple breaks, downtime and device removal. The seamless logging of events excludes all possibility of data tampering.

moldmind : At a glance Daily data Information recorded daily by moldmind includes: number of cycles, minimum and maximum cycle time, maximum temperature and temperature duration as measured by two temperature sensors, and operating time. Long-term statistics All data collected on a day-to-day basis is logged in an Excel sheet to enable long-term statistical analysis. Evaluating data using Excel or similar application A variety of easy-to-read diagrams can be created on the basis of the long-term statistics to facilitate analysis. Event data statistics moldmind records all configuration modifications and error messages occurring since activation and stores this information for use in its own event data statistics. This seamless logging of events excludes all possibility of changing the database. Tool database If multiple injection molds have been equipped with moldmind, the data from each mold can be consolidated into a single tool database.

Possible installation position Standard installation or retrofit. moldmind can be either integrated into the injection mold or mounted on the mold. A tappet installed opposite the piezo contact is used to record the number of shots. The temperature of the hot runner (and injection mold) is measured using one or, optionally, two thermocouples. Collected data can be transferred over an integrated RS 232 interface to a PC or notebook for analysis. moldmind TECHNICAL DATA Dimensions Weight Power supply Contact 70.0 x 51.5 x 43.0 mm ~185 g Battery (life approx. 5 years) Piezo-actuated counter Thermocouples 2 sensors (type J) IEC 60584 Measurable temperature range Display Internal temperature (moldmind ) of up to 512 C (950 F) 8-digit display; heat resistant up to 120 C depending on installation position 03/05. Technical specifications subject to change. Actual colors may differ. Protection class IP 65 Interface 1 x RS 232 Data cable Length: 1.50 m + extension cable 1.80 m Applied guidelines CE Included in delivery moldmind, data cable + extension cable, CD-ROM containing software, tappet unit, magnet unit, 2 thermocouples (type J) SYSTEM REQUIREMENTS Operating system Microsoft Windows (98, 2000, NT4, XP, ME ) Processor 300 MHz (min.) Hard disk space 5 MB (additional space is required for storing recorded data) Drive CD-ROM Interface Serial Program Microsoft Excel or similar application Otto Männer Vertriebs GmbH Unter Gereuth 9-11 79353 Bahlingen Germany Phone +49 (0) 7663 609-0 Fax +49 (0) 7663 609-299 info@maenner-group.com www.maenner-group.com The Excel sheets and diagrams shown in this brochure are samples only and can differ to the original Excel sheets and diagrams created by moldmind software. Microsoft, Windows, Windows 2000, Windows XP, Windows.NET, Windows 95, Windows 98, Windows ME and Windows NT are trademarks of Microsoft. All other marks or product names are the properties of their respective owners. All rights reserved 2005.