Instrument Software Update Instructions



Similar documents
Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.

Installing Global Logger USB Drivers

In order to enable BitLocker, your hard drive must be partitioned in a particular manner.

User Guide for Windows 10

To download and install directly to your phone

PC Instructions for Miller LiveArc Software

Applies to: F1PG200ENau Belkin Analogue Telephone Adapter (ATA) Firmware release notes

Phaser 3635MFP Software Upgrade Process

HP Personal Workstations Step-By- Step Instructions for Upgrading Windows Vista or Windows XP Systems to Windows 7

ThinLinX TLXOS 64-bit Firmware Installation Guide for the Intel NUC Range. Materials Required

XConsole GUI setup communication manual September 2010.

Shearwater Research Dive Computer Software Manual

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

For Windows XP 64 bit

SNMP Manager User s Manual

Installation Manual for Multi-purpose Ecological Risk Assessment and Management Tool (AIST-MeRAM) For Windows 8

SSD Firmware Update Utility Guide

USB External Hard Disk Drive

Motion Computing Tablet PC

Printer Driver Installation Guide

Driver Updater Manual

To download and install directly to your phone


Joining an XP workstation to a domain Version 1.00

Argus Direct add-in for spreadsheets - Installation Guide

c. Securely insert the Ethernet cable from your cable or DSL modem into the Internet port (B) on the WGT634U. Broadband modem

Welch Allyn Vital Signs Monitor 300 Series

Windows 8 Backup, Restore & Recovery By John Allen

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

Verizon Wireless 4G LTE USB Modem 551L Software Upgrade

The FlexiSchools Online Order Management System Installation Guide

FAQ for Eee Pad TF201

HOW TO DOWNLOAD AND INSTALL ANDROID AUTO

Updates Click to check for a newer version of the CD Press next and confirm the disc burner selection before pressing finish.

Introduction 1-1 Installing FAS 500 Asset Accounting the First Time 2-1 Installing FAS 500 Asset Accounting: Upgrading from a Prior Version 3-1

Maintaining the Content Server

Digital Persona Fingerprint Reader Installation

CLEARONE DOCUMENT (REVISION 1.0) October, with Converge Pro Units

Chapter 1 Installing the Gateway

Time Machine Setup for Routers

The FlexiSchools Online Order Management (FOOM) Installation Guide

Updating the BIOS and BMC on the FreeNAS Mini

COMPRESS Installation Guide

Intel Data Migration Software

Carry it Easy. User Guide

DocAve Upgrade Guide. From Version 4.1 to 4.5

PLEASE NOTE: The client data used in these manuals is purely fictional.

Hi-Speed USB Flash Disk User s Manual Guide

3.5 EXTERNAL NETWORK HDD. User s Manual

Microsoft Windows 7 Ultimate 64 Bit SP1 Operating System Recovery Media for 300 GB Solid State Drives Instructions

Upgrading from Call Center Reporting to Reporting for Call Center

Lab - Dual Boot - Vista & Windows XP

FAQ for Transformer TF201

Fiery Clone Tool For Embedded Servers User Guide

Lenovo IdeaCentre Q180 Series

Verbatim Secure Data USB Drive. User Guide. User Guide Version 2.0 All rights reserved

NAVICO SOFTWARE UPGRADE TOOL

Instructions for installing Microsoft Windows Small Business Server 2003 R2 on HP ProLiant servers

Clickfree C6 Easy Imaging October 24, 2011

HP EliteBook and ProBook Notebook PCs - Upgrading from Windows 7 to Windows 8

Intel Rapid Storage Technology

Using GIGABYTE Notebook for the First Time

User Manual. Thermo Scientific Orion

HP RDX Continuous Data Protection Software Quickstart Guide

Software Update, Backup, and Recovery

TE100-P21/TEW-P21G Windows 7 Installation Instruction

Quick Start Using DASYLab with your Measurement Computing USB device

Transferring Scans from your Dolphin into Destiny

Guide to Installing BBL Crystal MIND on Windows 7

Schneider OS-Loader usage via Ethernet or USB.

Installing VPN for PC v1.3

FAQ for Eee Pad TF201

MiraCosta College now offers two ways to access your student virtual desktop.

USB Bare Metal Restore: Getting Started

Windows XP.. ELITE Firmware Update procedures.. v1.41

This Manual contains the following How To information:

How to downgrade Samsung Galaxy Tab 2 back to original V4.1.1 Android OS

Getting to Know Your Mobile Internet Key

Nexio Backup and Recovery

Digi Connect Wan 3G Application Guide Update the firmware, backup and restore the configuration of a Digi Connect Wan 3G using a USB flash drive.

Configuration and Access of FTP Server

Virto Password Changer Web Part for SharePoint. Release Installation and User Guide

You can find the installer for the +Cloud Application on your SanDisk flash drive.

How to Install Applications (APK Files) on Your Android Phone

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 16 Fixing Windows Problems

Installation Guide. Keysight Software

Stellar Phoenix Exchange Server Backup

Citrix Desktop for Home Computers Apple ios Instructions

DataSuite Installation and Activation Guide

How to use SURA in three simple steps:

Technote 20 Using MSIE to FTP into an AcquiSuite

AUDITVIEW USER INSTRUCTIONS

EVA Drivers 6.1 and TWAIN Installation Guide for EVA Classic Digital Sensors

How to Make a USB Bootable

FTP Server Application Guide REV:

SQL Server 2008 R2 Express Edition Installation Guide

Information Sheet IS13011A. VS Series - Recovering / Installing the Operating System. (For Software Version 4.x) Issue

USB Driver Installation for Windows XP

Nellcor Portable SpO 2 Patient Monitoring System PM10N V1.05 Software Upgrade. Laura DeNuccio February 2015

User Guide. G 4 Supreme. April AES 256 Encrypted USB Flash Drive. Prepared By: Md. Zakir Hosen

Transcription:

Instrument Software Update Instructions These update instructions are valid for the following signal analyzer models: N9000B, CXA Signal Analyzer N9010B, EXA Signal Analyzer N9020B, MXA Signal Analyzer N9030B, PXA Signal Analyzer N9040B, UXA Signal Analyzer N8973B, 10 MHz to 3.6 GHz, NFA X-Series Noise Figure Analyzer N8974B, 10 MHz to 7 GHz, NFA X-Series Noise Figure Analyzer N8975B, 10 MHz to 26.5 GHz, NFA X-Series Noise Figure Analyzer N8976B, 10 MHz to 40 GHz, NFA X-Series Noise Figure Analyzer Purpose The purpose of this document is to outline the instrument software update procedure for the N9040B, UXA Signal Analyzer from the revision that is currently installed, to the latest revision available. The advantages of updating the instrument software with the current revision include: 1. Keeps the analyzer current and up to date. 2. Updates the advanced measurement applications where appropriate. 3. Updates the PC board software where appropriate. An update to the instrument software version does not require a new license key for the measurement application(s), so long as the application(s) were licensed prior to the update. This procedure will not update the 89601A or 89601B VSA measurement software. To determine what revision of instrument software is currently installed, press the [System] hardkey, then tap Show System. Look for the Instrument S/W Revision number as shown below. If the installed revision is the same as the latest revision on the web, there is no need to update the software. 1

Instrument Software Installation Note: This will only update the instrument software that currently resides in the C:\Temp folder. It will not update the version that exists on the recovery partition. Because of this, if the recovery process is performed, the instrument will revert back to the instrument software revision that was originally shipped from the factory. Requirements To use this update procedure, the following requirements must be met: Instrument must be functioning properly before the update is attempted Must have the ability to login to the instrument as the administrator Must have the ability to transfer a large file (~1G Byte) to the instrument being updated File Download 1. Go to http://www.keysight.com/find/uxa_software 2. Download the executable file by clicking on the Download button. Save the file to a location of your choice. If you do not have the ability to download files directly to the C: drive of the instrument being updated, store the file on a large capacity USB storage device for transfer to the instrument. (The file size is ~1 GByte.) Update Procedure 2

The default user account is Instrument, which does not have the required permissions to install the instrument software updates. For the process outlined below, the user must be logged in as the Administrator. The UXA instrument software upgrade process has an install wizard which removes the old software version and installs new software version without manual steps. The removal of the old software version and the installation of the new software version completes in approximately 30 minutes. The instrument software update time will depend on how large the gap is between the currently installed instrument software version and the version being updated which may require that a number of FPGA updates are needed for the measurement boards. The FPGA updates are handled automatically during the instrument software update process. 1. If the analyzer is not already running, turn the analyzer on and allow it to completely boot up. 2. Close the analyzer application by pressing the [System] hardkey. 3. In the Application Controls area on the analyzer display tap Exit Program. 4. Log out of the default user (Instrument). If the Windows task bar is not present at the bottom of the screen, tap the lower section of the display until the Windows task bar appears and then tap the Windows Start iconshutdown arrowlog Off. 5. At the login prompt enter: User name: administrator Password: Keysight4u! 6. Press the Next arrow to log in. Note: If a Found New Hardware wizard window pops up, select No Not at this Time to bypass the activity. Instrument Software Install If you downloaded the instrument software update file to the instrument via LAN, access that file from the location that it was stored and proceed to step 1. If you downloaded the instrument software update file to a USB storage device, plug that into one of the USB ports on the front of the instrument. Access the file for the removable drive, then proceed to step 1. 1. Tap the Windows Start iconcomputerand select the appropriate file location. 2. Double tap the filename XSA_Installer_A.XX.XX.exe 3. A message will appear reminding you that you must be logged in as administrator; select Yes. 3

4. A window appears showing the extraction of the software installer as illustrated below. There is no interaction required from this point forward. When the extraction process is complete, the Software Updater window will appear and show the uninstall and install progress as illustrated below. No interaction with the instrument is required. There will be several windows appearing and disappearing during this process, which can take ~30 minutes. DO NOT cycle the instrument power for any reason at this time. If this process is interrupted, the instrument may end up in an unusable state, and will likely need to be returned to Keysight Technologies for repair before it will be usable again. 4

5

5. When the software installation is complete. You will be asked to reboot the instrument. If no action is taken the instrument will automatically reboot in 5 minutes. 6. After the instrument restarts it will boot up in the default Instrument account, perform the alignments, and display the measurement screen. 7. Check for any errors and verify that the new software version is installed by pressing [System], tap Show System and look for the Instrument S/W Revision as shown below. Note: If the instrument does not reboot, remove the USB storage device and cycle power. The boot order for the instrument may have been changed in the instrument BIOS previously, and the instrument may be instructed to boot from USB first, and the internal disk drive second. If this is the 6

case, failure to remove the USB device will result in an error, as the instrument attempts to boot from it. 7