L.P.G. vaporizer with liquid-phase-level electronic control



Similar documents
AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

ECOCIAT. Domestic hot water heat recovery unit

QSLM Dual inlet decompression unit with automatic change-over system FEATURES

4 Posiflow Proportional Solenoid Valves

Direct steam injection humidifiers

PDP and SD Series Pump Station

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Condensate water pump with neutralisation system

RI27 CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

valvole 16 mm ad azionamento pneumatico pneumatically piloted valves - 16 mm

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

AIR LINE VALVES AND GAUGES

3/2-way Solenoid Valve, direct-acting, NC or NO

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

ASME Packaged Indirect Fired Water Heater

Centro-Matic Automatic Lubrication Systems System Controls

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Overheating limit control

servo-controlled 3-WaY vacuum solenoid valves WiTH

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Float and Thermostatic Traps Series H, C and X

Kompressoren. Adsorption Dryer AD

Refrigeration Compressed Air Dryer Buran Ultrapulse

Hydraulic Control Solutions

SunMaxx Solar Filling Station Operating Instructions

Oil, Gas and Dual Fuel Burners

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

RGG WAVE. Alarm. Fault. Signalling Led di LEDs segnalazione. control RGM WAVE. Alarm. Fault. segnalazione. elettrovalvola

Blowdown vessels Meeting the requirements of HSE PM60

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

VDL 53 - Vacuum drying oven for flammable solvents

Fossil fuel heating equipment

Oil - kerosene burners

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

SELECTION, APPLICATION AND MAINTENANCE

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

Oil and Coolant Circulating Heating System. Model - OCSM

Operators manual Basic water heater

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

SOLENOID VALVES AND PNEUMATIC VALVES

HERZ-Thermal Actuators

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Vacuum drying oven for non-flammable solvents

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

BURNER WATER CONTROL UNIT

Morrison Bros. Co. General Product Specifications

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Power consumption (kw)

VSO MAX HP High Flow Proportional Valve

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

2.12. page Products for Explosion hazardous Environment

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

VALVES FOR REFRIGERATING SYSTEMS

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

167D Series Switching Valves

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

YFC... II 2(1) GD Ex d IIC T6 Ex td A21 IP 66/67 T85 C. IECEx SIR /9/CE EN EN EN EN

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Assisted lift operated 2/2-way solenoid valves Type EV250B

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Air Eliminators and Combination Air Eliminators Strainers

solarplus solar systems general features

Designed for multi-injector endurance testing, the

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Technical data. Danfoss DHP-A

1x90 TONS TENSIONERS TECHNICAL PROPOSAL. 1 X 90 Tons 30 m/min Tensioners TECHNICAL PROPOSAL JOB 08/ /02/2008 Basic proposal PP GM SB

Digital inductive conductivity transmitter

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

System 8. ü ( System 8

Thermometer in stainless steel with capillary and switch contacts

Refrigeration Air Dryers. Catalogue

WH/WIH/WIHD/WIHD&M/WIHL AND WIH SERIES

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

The Secret of Hydraulic Schematics. BTPHydraulics

2/2 and 3/2 Way Size 6 Seat Valves

OLI. Oil level indicator

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Luna 3 Comfort Troubleshooting Guide June 2008

Electric Flow Boiler

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Refrigerated Air Dryers. Catalogue

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

RPS. Sanitary sampling valves SAMPLING

Operating instructions

Transcription:

DESIGN, SALE & INSTALLATION OF L.P.G. - - NATURAL GAS SYSTEMS New LEVEL CONTROL L.P.G. vaporizer with liquid-phase-level electronic control New LEVEL CONTROL L.P.G. vaporizer with liquid-phase-level electronic control New LEVEL CONTROL L.P.G. vaporizer with liquid-phase-level electronic control Water Type Water Type 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY 3L.P.GAS - ITALY

1 2 3 4 Caratteristiche Tecniche 1 TERMOMETRO (Temperatura acqua) 2 MANOMETRO (Pressione gas) 3 VALVOLA PORTAMANOMETRO 4 DISPOSITIVO PER CONTROLLO LIVELLO LIQUIDO 5 VALVOLA DI INTERCETTAZIONE (Chiusura manuale) 6 ENTRATA ACQUA (Attacco flangiato) 7 VALVOLA DI SPURGO (Impurità del gas) 8 FILTRO A CESTELLO 9 VALVOLA DI INTERCETTAZIONE (Chiusura pneumatica e manuale) 10 ATTUATORE PNEUMATICO 11 USCITA ACQUA (Attacco flangiato) FEATURES 5 Il vaporizzatore per G.P.L. 3L.P. GAS "LEVEL CONTROL " rappresenta un'innovazione nel campo delle apparecchiature per la vaporizzazione del G.P.L.; collegato in fase liquida al serbatoio di stoccaggio ( vedi schema di funzionamento ) permette, unico nel suo genere, il controllo del livello della fase liquida al suo interno in modo elettronico e consente la gestione dei segnali in uscita ( in sicurezza intrinseca ) a seconda delle esigenze. Il succitato dispositivo ( Pos.4 ) rileva istante per istante l'altezza del liquido presente nel vaporizzatore, ed al superamento della soglia limite per la quale lo stesso è dimensionato, invia in tempo reale il segnale per la chiusura della valvola di adduzione ( pneumatica o elettrica ) G.P.L. in fase liquida ( Pos. 9-10 ). Sono possibili anche collegamenti a spie visive e/o acustiche di preallarme, e controllo tramite P.C.. I vaporizzatori sono interamente costruiti secondo le normative vigenti e testati uno ad uno a pressione di 27 bar ( tubazione gas e acqua ); la produzione di serie ( vedi tabelle A e B ) è ampliabile a richiesta e copre qualsiasi tipo di capacità necessaria. ANNI DI PROGETTAZIONI E INSTALLA- ZIONI DI IMPIANTI "CHIAVI IN MANO" PER IL G.P.L. IN TUTTO IL MONDO SONO LA N/S GARANZIA DI AFFIDABILITA' E SICUREZZA, E IL VAPORIZZATORE " LEVEL CONTROL " SARÀ LA V/S TRANQUILLITÀ DI POS- SEDERE FINALMENTE UN'APPAREC- CHIATURA SICURA. 1 THERMOMETER (Water Temperature) 2 PRESSURE-GAUGE (Gas Pressure) 3 PRESSURE-GAUGE HOLDER VALVE 4 LIQUID-LEVEL CONTROL DEVICE 11 10 5 ON/OFF VALVE (Manual Closing) 6 WATER INLET (Flanged Pipe) 7 BLEEDER (Gas Impurities) 6 9 8 BASKET STRAINER 9 ON/OFF VALVE (Pneumatic/Manual Closing ) 10 PNEUMATIC ACTUATOR 11 WATER OUTLET (Flanged Pipe ) 7 8

Schema di funzionamento OPERATION DIAGRAM 3L.P. GAS "LEVEL CONTROL" LPG Vaporizer represent a step ahead in the manufacturing of LPG Vaporization Systems; the only system of its kind, it allows electronic and internal liquid-phase-level control and output signals management (intrinsic protection method) on a perneed basis, through its connection to the storage tank's liquid-phase (see operation diagram). The above mentioned device (see detail # 4) provides moment-by-moment liquidlevel depth measurement inside the vaporizer, and sends a real time valveshutoff signal to the LPG liquid-phase suction valve (electrical or pneumatic, see details # 9-10) whenever the system threshold is exceeded. Visual and/or acoustic prealarm systems are available, as well as a PLC. All vaporizers are entirely built in accordance with applicable laws and are individually tested at 27 bars (water and gas pipes); series production (see Tables A & B) is subject to expansion to suit customer demand and meets any type of required capacity. YEARS OF WORLDWIDE DESIGN & INSTALLATION OF "TURNKEY" LPG SYSTEMS ARE OUR WARRANTY OF RELIABILITY & SAFETY; OUR "LEVEL CONTROL" VAPORIZERS WILL GRANT YOU THE PEACE OF MIND THAT COMES WITH OWNING SAFE EQUIPMENT AT LAST.

WATER VAPORIZERS - PRODUCTION PLAN CAPACITY Kg/h L.P.G. INLET Ø L.P.G. OUTLET Ø 50 1/2" 1" STANDARD PRODUCTION 100 1/2" 1" 200 1/2" 1" 300 3/4" 1¼" 500 1" 1½" ALL SIZES OF CAPACITY ARE AVAILABLE ON REQUEST ELECTRIC VAPORIZERS - PRODUCTION PLAN CAPACITY Kg/h L.P.G. INLET Ø L.P.G. OUTLET Ø ABSORBED POWER Kw STANDARD PRODUCTION 35 1/2" 1" 4 50 1/2" 1" 8 100 1/2" 1" 16 300 1" 1½" 32 DIFFERENT SIZES OF CAPACITY ARE AVAILABLE ON REQUEST D IMENSIONS A = 1975 mm. B = 2100 mm. C = 430 mm. D = 1020 mm. E = 400 mm. F = 430 mm. G = ND 32 (gas inlet) H = ND 65 (gas outlet) L = ND 50 (water outlet) M = ND 50 (water inlet)

LEVEL CONTROL L.P.G. WATER VAPORIZER YEAR 1999 POWER 1500 Kg/h MANUFACTURER # 119/99 & 132/99 SUPPLIER CERTIFICATE Law n 46 5-03 - 1990. REGULATIONS FOR PLANT SAFETY. DPR 6-12 - 1991 Execution of regulations. The materials constituent the vaporizers, are in conformity to feature request. In particular: GAS CIRCUIT - Execution NP40 The pipes, plate, flanges specials parts, are in conformity to use class, with test certificate. The weldings (only electric), are made from skilled welder, with quality electrode use. The test are made with water pressure 27 Bar (18 Bar maximum working pressure +50%) with positive issue. WATER CIRCUIT - Pressing at 3 Bar, with positive issue. 5

Pressure Gauge L.P.G. Gaseous Phase Magnetic Level Gauge L.P.G. Liquid Phase Temperature Gauge Tank Saddle Excess Flow Valve Safety Valve Ground Plate OPERATION 6

Liquid Level Control Pressure Gauge Temperature Gauge Safety Valve Air Vent Valve First Stage Pressure Reducer Solenoid Valve External Impulse Valve Basket Filter Drain Valve DIAGRAM 7

3 L.P. GAS LEVEL CONTROL VAPORIZER The 3 L.P. GAS "LEVEL CONTROL" Vaporizer are basecally made of 3 distinct chambers: - The central one for the L.P.G. passage (built with API 5L Gr.B pipes sch.40); - The intermediate having the hot water container purpose; - The external one used as a thermical insulation. The L.P.G. pipeline's test is made with 27 bar of pressure (1,5 time more than max working pressure = 18 bar). The heating surface design give You the required capacity: 50-100 - 150-200 Kg/h for the standard electric versions and 50-100 - 200-300- 400-500 Kg/h for the hot water types. More powerfull vaporizers can be built on request. Each produced "level control" vaporizer includes, as a absolute news on this apparatus field, a special electronic device wich feel in real time the liquid level inside vaporizer. The sensor works on intrinsical safety way and all other electrical parts are explosion proof made. The a.m. sensor grants You (unique of it's kind) in case of dangerous situations, the immediate and complete fluid block and the consequent impossibility to find the liquid on the outlet line! The differences between the "level control" vaporizers and the others on market are mainly based upon this safety system, which oppositely to the normal types is not based on the floater action (that goes up when the liquid level is too high, and mechanically, using the force of the liquid weight, move a leverage which close the "clapet" valve). As easily imaginable, a part of liquid, using the a.m. old solution can goes on the main line; first of all because, before the liquid arrival at the floater level, a part of vapour/liquid mix already passed the safety zone. This mean that a part of liquid will be inside the main line when the valve close!!! You can imagine the results You'll find on the utilization point in this case (1 part of L.P.G. liquid volume becomes 270 parts of vapour!!!!!) The solution used to solve this extremely dangerous trouble by the vaporizers manufacturer are: a) install a shut-off valve operated by thermostat at the end of the main line (both always out of supply price) b) install a solenoid valve at the inlet operated by a thermostat placed on the water circuit (both always out of supply price) The a.m. solutions could be satisfactory thinking to avoid troubles to the utilizators, but there are some points not solved: - on the a) case You've got to stop all works and machinaries, drain perfectly all the line startig from vaporizer untill the end loosing a lot of time and money (factory stop etc.) - the b) case is even worst than the a) one, because nobody can guess if the sensor will be quick enough to feeel the danger (consider that the water temperature is always related to two variables: pressure and gas temeperature at the outlet). 8

The vaporizer forniture include also: - SOLENOID OR PNEUMATIC VALVE - ELECTRIC PANEL including : intrinsecally safety relay, electromagnetic swich, terminal board, working status lamps (electric type) - EXPLOSION PROOF RESISTENCES (electric type) - EXPLOSION PROOF BOX (electric type) - CONDUIT HOSES (electric type) - WORKING STATUS LAMPS - MIN. TEMPERATURE ALARM (electric type) - ELETRONIC LEVEL CONTROL SYSTEM - SAFETY VALVE gas phase - SAFETY VALVE water phase - PRESSURE GAUGE - THERMOMETER - BALL VALVES tropical-galvanized, "fire safe" type NP40 inlet and outlet gas phase - BALL VALVES water type - DRAIN SYSTEM - BASKET FILTER - N 3 THERMOSTATS (2 adjustable + 1 fixed) (electric type) SHUT - OFF SYSTEM: The "LEVEL CONTROL" Vaporizer are made with two differents shut-off system: pneumatic or with explosion proof solenoid valve. The solenoid valve, placed on the liquid phase inlet, is standard mounted on the vaporizers 50 and 100 Kg/h electric and hot water version, (rispectively Ø ½" e Ø ¾") on request for higher capacity. Electronic sensors inside the L.P.G. pipe, when the liquid level reach the dangerous point, becomes excited and sends the immediate signal to the solenoid valve wich stop the inlet. The same shut-off system is also available with a pneumatic valve instead the solenoid one. Both solutions working in "positure safety" (no tension or no air close the valve). IMPORTANT: The electronic sensor must works on "intrinsecally safety" way, this mean that the "electronic relay" (included on the scope of supply) is made to be placed out of the explosion proof site. ELECTRIC RESISTANCE CARACTERISTICS: - Available: 220-380 - 415 V. - Explosion proof made (with certificate) IP 54 EExd II CT3 9

Electromagnetic Level Indicators EMPLOYMENT The electromagnetic level indicators have been designed to check the lavel of a fluid as water, gas oil, solvents, acids, etc. contained in a tank and send an electric signal of min and max level alarm on the control board. They are normally employed in the oleodynamics, lubrification, plant engineering, fluid stocking, industrial vehicles, electricity generation, etc. COMPONENTS Fastening flange in anodized aluminium, brass bar, NBR expanded resin float or in stainless steel. TECHNICAL DATA: Commutated Power 60 W Commutated Power 60 VA Max voltage ~ 220 V-50 Hz Max intensity of current 0.8 A (resistive) Idle contact (without fluid) "NC" Open contacts capacity 0.6 pf Contact insulation resistance 10 10 ohm Electrical connection PG9-DIN 43650 Electrical protection IP65-DIN 40050 Working temperature -10 +80 C Gasket Viton max temperature 130 C Fastening Vertical Max slope 15 Maximum pressure 20 bar Fluid specific weight ³ 0.7 Fluid viscosity 150 cst. Type LM1GA500 10

Via Bologna 14-43036 FIDENZA (PR) - ITALY Phone +39 0524 527766 Fax +39 0524 525456 http://www.3lpgas.com 13 e-mail:3lpgas@polaris.it