I. Project Initiation Sheet (if any information changed since Concept Plan submittal)



Similar documents
SECTION 5 DRAFTING STANDARDS

City of Colleyville Community Development Department. Site/Landscape Plan Application Packet

SITE IMPROVEMENT PLANS CHECKLIST

Preliminary Plan Application and Checklist

WESTFIELD-WASHINGTON ADVISORY PLAN COMMISSION December 7, SPP-24 & 1512-ODP-24

Minor Accommodation Planning Review Application

FILE NO.: Z-6915-C. Gamble Road Short-form PCD and Land Alteration Variance Request

City of Douglas Commercial Building Permit Site Application

B. Improve the appearance and character of areas surrounding new development.

Electronic Signature and Fee Payment Confirmation

Development Variance Permit Application Package

Washington City Subdivision Development Application Checklist

CITY COUNCIL PACKET MEMORANDUM

ORDINANCE NO (As Amended)

ORDINANCE NO

SOLD. Lot 1. 1 Mile: Population: 10,200 Median HH Income: $33, Mile: Population: 80,200 Median HH Income: $34,900

PROPERTY LINE ADJUSTMENT APPLICATION

CITY OF AURORA S STANDARDS FOR DOCUMENT FORMAT, CERTIFICATES, STATEMENTS AND EASEMENTS

SITE PLAN REVIEW APPLICATION

PLANNED UNIT DEVELOPMENT & SIDEWALK WAIVER REQUEST STAFF REPORT Date: November 7, 2013

PROFFER STATEMENT REZONING TLZM LEEGATE November 1, 2013

APPLICATION FOR TENTATIVE MAPS

SERVICES THAT MAY ONLY BE PERFORMED BY A NEW JERSEY PROFESSIONAL LAND SURVEYOR

TOWN OF JUNO BEACH 340 Ocean Drive Juno Beach, FL Phone: (561) Fax: (561)

Division Yard, Lot, and Space Regulations.

VILLAGE OF PLEASANT PRAIRIE COMMERCIAL COMMUNICATION PERMIT

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet

RESIDENTIAL BUILDING PERMIT REQUIREMENTS

PRELIMINARY PROJECT REVIEW PROCESS

R 1 Design Review Application

TYPES OF PROPERTIES ARE INCLUDED WITHIN THE T3 TRANSECT DESIGNATION?

Maximum Floor Area and Maximum Development Area

Town of Elkton & Cecil Soil Conservation District Checklist for Joint Agency Review Stormwater Management / Erosion and Sediment Control

Residential Plan Routing Information

UDRB APPLICATION URBAN DEVELOPMENT REVIEW BOARD

SITE SAFETY LOGISTIC PLAN

Bureau Veritas Contact Information

Section 801 Driveway Access Onto Public Right-of-Ways

CITY OF HILSHIRE VILLAGE NEW HOUSE AND HOUSE ADDITION PLAN SUBMITTAL CHECK LIST ADDRESS: DATE:

5901 Milwaukee Street Planned Unit Development (GDP) (Second Addition to Grandview Commons)

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

Kirkland Zoning Code

MOBILE HOME LAW. Revised November 2001

TOPOGRAPHICAL SURVEY REPORT - PART OF L.R No. 7413/11 Done on February 2015 at International Union for Conservation of Nature (IUCN) Eastern African

28.0 Development Permit Area #2 (Neighbourhood District)

AREA: 0.16 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF

Single Family Residential Building Permit Questions & Answers

BLOCK 400 PLANNED COMMUNITY DISTRICT

CERTIFICATE OF APPROVAL OF LOCATION (CAL) APPLICATION Page 2

INCORPORATED VILLAGE OF OYSTER BAY COVE TOWN OF OYSTER BAY, NASSAU COUNTY, N.Y. OFFICE BUILDING INSPECTOR FEE SCHEDULE

BUSINESS USE PERMIT APPLICATION

d. Building permits may only be approved if consistent with the approved development plan and land division for all units with common walls.

Site Development Information Worksheet for single family residential development

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

Architectural Design Standards Example Guide DESIGN STANDARDS EXAMPLE GUIDE

CITY OF YORBA LINDA P.O. BOX CALIFORNIA

CITY OF WEST PALM BEACH ZONING BOARD OF APPEALS Meeting Date: February 6, 2014 Zoning Board of Appeals Case No. 3302

Residential Building Permits Information

County of San Diego, Planning & Development Services SECOND DWELLING UNIT

Data Center Due Diligence List

Right-of-Way Permit Application Process (Plans that affect District owned or maintained right-of-way)

Lincoln County Floodplain Development Permit Application

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

FILE NO.: Z LOCATION: Located on the Northeast and Southeast corners of West 12 th Street and Dennison Street

Basic Elements of Reading Plans

NOTICE OF A TYPE Ix DECISION ON A PROPOSAL IN YOUR NEIGHBORHOOD

INTRODUCTION TO ZONING DISTRICT REGULATIONS

PRE APPLICATION CONFERENCE - INTRODUCTION

Brevard County Public Works Finance and Contracts Administration

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

Requirements for Building Application Submission

Waterleaf ARB Application

Application Package for License for Sidewalk Dining Adjacent to Eating Establishment

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

2005 MINIMUM STANDARD DETAIL REQUIREMENTS FOR ALTA/ACSM LAND TITLE SURVEYS

BEACON AVENUE URBAN RENEWAL PROJECT

G.S Mapping Requirements for Recordable Maps

Neighborhood Business. Neighborhood Mixed Use. Community Business. Factoria Land Use District 1 2A 2A 2A 30 (23) 15 (23) 30 (23) 30 (23)

City of Mandeville. Guidelines for Construction and Development

Engineering Comments will be available at the DRC Meeting.

New Electric Connection Application Packet Commercial and Industrial. City of Plummer P.O. Box B, Plummer, ID (208)

Definition of Tower from the Bradley County Zoning Resolution

THE TOWN OF COLONIAL BEACH, VIRGINIA DEPARTMENT OF PLANNING AND COMMUNITY DEVELOPMENT

APPLICATION FOR HISTORIC MIRAMAR COMMERCIAL REHABILITATION PROGRAM (TARGET AREA)

Close-Out Documents... 9

City of La Vernia 102 E. Chihuahua Street, La Vernia, Texas Phone: (830) Fax: (830)

Sample Drawing Package for One and Two Family Dwelling Applications

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

June 22, District 10 Eastern Urban Center (EUC) Patricia Ferman Jeff Steichen

Outdoor Cafés & Sidewalk Cafés

PLANNING DIVISION STAFF REPORT February 23, Summary. Background Information PREPARED FOR THE PLAN COMMISSION. Legistar File ID # 36810

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

MIAMI 21 AS ADOPTED MAY 2010

Land Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department

Transcription:

Development Services 201 W. Colfax Avenue, Dept. 203 Denver, CO 80202 P: 720-865-2982 www.denvergov.org/developmentservices Formal Site Development Plan Submittal Checklist General Submittal Requirements I. Project Initiation Sheet (if any information changed since Concept Plan submittal) II. Review Fees (Refer to the Concept Letter for the amount. Fees due at the time of 2 nd formal submittal.) III. Site Development Plan set, including the following sheets: Sheet 1 Sheet 2 Sheet 3 Sheet 4 Sheet 5 Sheet 6 Sheet 7 Sheet 8 Sheet 9 Cover Sheet Survey Site Plan Parking Plan Sheet(s) (if applicable) Utility and Grading Plan Landscape Plan Architectural Building Elevations Photometric Plan Details (this sheet is optional, details may be shown on other sheets as space permits) General Format Requirements Applicable to All Sheets 1. Sheet Size: All submittals are accepted electronically in PDF format. Original AutoCAD drawings must be formatted to 24 x 36 sheet size. 2. Scale: 1 =50 (preferred); 1 =20, 1 =30, 1 =40, 1 =60, and 1 =100 (may be also used). Architectural building elevations may be shown in architectural scale. Please label each plan with scale used. 3. A border, 1 inch from the top, bottom, and right side, and a minimum of 3 inches in from the left side. 4. A Title Block including name of development, type of development, quarter section, township, and range. The Title must also include address or location of project by nearest intersection when address is not available. The Title needs to be centered at the top of the sheet. 5. Name of development needs to be in lower right hand corner underneath the border. 6. Page number in lower right hand corner of each sheet above the border.

7. Zone Lot boundaries must be clearly shown in solid heavy line on all sheets. 8. All lettering must be at least 3/32 inch high (equivalent to 10 point height) at the 24 x36 format. 9. North arrow must be clearly shown and must be in same direction on all sheets. 10. All information must be presented in black and white format, except for building elevations rendering submitted for the Urban Design Review (when applicable). Information to be Shown on Site Development Plan Sheets Sheet 1 - Cover Sheet 1. Title Block 2. Vicinity Map identifying the subject property, the adjoining streets, and the major streets in the surrounding area. Generally, the vicinity map should include the area within a one-half mile radius of the site and should be at a scale of 1 =1000 or 1 = 2000. If site is in a view plane, or within 200 of a view plane, document location and name of view plane on the vicinity map. 3. Legal Description. If the subject site is a portion or phase of a larger area integral to the subject site, legal descriptions may be required for both the overall area and the phase or phases for which plans are submitted. These phases, if any, should be illustrated on a key map. Legal description needs to include square footage of the property. 4. Statistical Information. (Choose one, Table A or Table B) Table A. (Use this template for projects reviewed under the new code - Denver Zoning Code) Zone District General Zone Lot Information Sq. Ft Acres Zone Lot Size (Gross Project Area) Area to be deeded for additional right-of-way Net project area (after deeding of any needed public right-of-way) Primary and Side Street Designations Proposed Use (s) Number of dwelling units (residential projects only) Gross Floor Area for each use ( for non residential and mixed-use projects) 2

Building Form Used Design Elements Required Provided Building Height, Stories ( min/max) Building Height, Feet (min/max) Build-To Required Provided Primary Street Total Build-To (min % within min/max) (Refer to Sheet X of XX for details) Side Street Total Build-to (min % within min/max) (Refer to Sheet X of XX for details) Overall Buildings or Structure Length (max) Parking Standard spaces Compact spaces Accessible Total Required (min/max) Provided Note: ( if the amount of parking provided is less than required please provide reference to the DZC Section that were used for reduction) Bicycle (enclosed/fixed) Loading spaces Ground Story Activation (Transparency) Required (min) Provided Total Transparency Primary Street (%) (Refer to sheet X of XX for analyses) Total Transparency Side Street (%) (Refer to sheet X of XX for analyses) 3

Table B (Use this table for projects reviewed under the old code Former Chapter 59) Zoning Proposed Use General Zone Lot Information Sq. Ft Acres Zone Lot Size (Gross Project Area) Area to be deeded for additional right-of-way Net project area (after deeding of any needed public right-of-way) Number of dwelling units (residential projects only) Net project density (based on net project area; residential projects only) Gross floor area per zoning definition 59-2 (131); include any floor area in mezzanines, include area of structured parking separately Floor area ratio per zoning definition 59-2 (119) Height of structures per zoning definition 59-2 (52)(feet/ stories), and the reference point for the measurement Ground coverage by all primary and accessory structures Ground coverage by all parking Ground coverage by all landscaping Sq. ft % Required Provided Land area per dwelling unit Open space per dwelling unit Landscaped open space per dwelling unit Parking Required (min/max) Provided 4

Standard spaces Compact spaces Accessible Total parking spaces provided Bicycle spaces Loading spaces 5. General Notes: a. Fences, walls, signs and accessory structures are subject to separate reviews and permits. b. Angles not shown are either 90 degrees or a supplement of the angle indicated. c. Private roadways will be posted with Fire Lane signs as required by the Denver Fire Department. d. Parking spaces for persons with disabilities will be clearly delineated with upright signs. e. Approval for this plan does not constitute or imply compliance with ADA requirements. f. Site(s) shall be landscaped prior to issuance of a final Certificate of Occupancy (CO) during the growing season of April 1 st to October 1 st, at all other times the individual sites shall be landscaped within 45 (forty-five) days of the start of the following growing season. g. An access easement for emergency services is hereby granted on and across all areas for police, fire, medical and other emergency vehicles and for the provision of emergency services. h. All landscape areas shall be irrigated with underground automatic irrigation system. Trees, shrubs, and decorative grasses will be irrigated by a separate zone from sod/grass; this includes trees planted in sod/grass area. The irrigation system is to have a rain sensor shutoff installed. i. Private roadways are non-dedicated streets and will not be maintained by the City and County of Denver (use this note only if applicable) j. Responsibility for the maintenance of the of Commonly Owned Land and Storm Water Detention facility constructed as part of this development will be that of the Home Owners Association/Property Owner(s) of Parcel(s) (use this note only if applicable). 6. Sheet Index. Label each sheet and provide page number for each sheet in the site plan set in the following format: Sheet X of YY. 5

7. Owner Signatures Block. Use this signature block if your project is reviewed under the new zoning code Denver Zoning Code OWNER'S SIGNATURE I (WE), the undersigned, shall comply with all regulations contained in Denver Zoning Code. The following signatures constitute all owners and holders of deeds of trust for land and structures included in this plan: BUILDER INVESTMENTS, INC. BY DATE John J. Builder, President State of Colorado City and County of Denver The foregoing instrument was acknowledged before me this (day) day of (month) AD 20 by John J. Builder. Witness my hand and official seal My commission expires: Notary Public Address Use this signature block if your project is reviewed under the old code Chapter 59, or under PUD OWNER'S SIGNATURE I (WE), the undersigned, shall comply with all regulations contained in Former Chapter 59 of the Revised Municipal Code of the City and County of Denver. The following signatures constitute all owners and holders of deeds of trust for land and structures included in this plan: BUILDER INVESTMENTS, INC. BY DATE John J. Builder, President State of Colorado City and County of Denver The foregoing instrument was acknowledged before me this (day) day of (month) AD 20 by John J. Builder. Witness my hand and official seal My commission expires: Notary Public Address 6

8. Surveyor s Signature Block SURVEYOR'S CERTIFICATION I, James B. Surveyor, a Registered Land Surveyor in the State of Colorado, do hereby certify that the survey for the (name of development) was made under my supervision and the accompanying plan accurately and properly shows said survey. James B. Surveyor, P.L.S., #0000 NOTE: Allow room for the surveyor's seal. The surveyor must sign and affix his seal (raised seal) to the photographic Mylar of the approved final plan. 9. Approvals APPROVALS Approved by For the Zoning Administrator Approved by For the Manager of Community Planning and Development Date Date 10. Clerk and Recorder s Certification CLERK AND RECORDER'S CERTIFICATION State of Colorado }SS. City and County of Denver I hereby, certify that this instrument was filed for record in my office at (hour) o'clock.m., (date) 20 and duly recorded under Reception #. Clerk and Recorder; Ex-Officio Clerk of the City and County of Denver By Deputy Fee 7

Sheet 2 - Survey Sheet 1. Include the boundary of the development in a heavy solid line on all sheets in plan. 2. The Survey shall conform to CRS 38-51-104, and 38-51-106 and the surveyor shall reestablish the range line control system for the block on which the development is proposed and install the necessary range points and housing boxes with ties to the City Survey Control System for that block. For areas where Range Line systems have never existed, the Survey shall be tied to the Public Land Survey System (contact the City of Denver Surveyors Office for guidance). 3. Reference to the Book and Page numbers or the reception numbers of recorded easements together with the county and date of recording. Include dimension and tie easements to the property boundary. 4. Include the City of Denver Benchmark describing the BM number, description, location and elevation (NAVD 1988). 5. Label, delineate, and include centerline geometry of private roadways to be used for emergency access on plan. Geometry must close and be tied to the property boundary. 6. Dash or shade all existing improvements, Lot lines and Lot numbers. Sheet 3 - Site Plan 1. Show and label Zone Lot boundary lines as heavy solid black line. Provide dimensions. 2. Identify the land use and zone district information of all adjacent land. 3. Show building footprints of all existing structures to remain and all proposed buildings and structures. Show all projecting building elements such as cantilevered floor areas, balconies, bay windows, etc. and recessed elements. Show points of ingress and egress. 4. Show and dimension required setback and/or build-to lines for all structures. Show and dimension setback provided (if greater than required setback). Show all existing or proposed structures encroaching into the required setback and provide maximum encroachment limits. Provide distances between structures. 5. Show all existing and proposed public and private streets and alleys adjacent to the site. Provide flow line to flow line dimensions, and label street names. Identify primary and side streets. Refer to Section 13.1.5 of the DZC for definitions and rules. 6. Locate and dimension vehicular access to the site (curb cuts). 7. Show all three sight distance triangles. 8. Show general parking arrangement. Provide dimensions for all parking stalls, vehicular driveways, and loading areas. Locate and provide dimensions for accessible spaces and accessible routes to building entrance. 9. Locate and provide width for pedestrian sidewalks and walkways, including the required pedestrian connection to the primary street (e.g., required entrances). Label all surfaces so that the materials used can be determined. 10. Locate and provide detailed design (dimensions and materials) for existing and proposed fences, garden walls, retaining walls, and trash enclosures and facilities. 11. Show location of all freestanding light fixtures. 8

12. Show location and approximate dimensions of all existing and proposed signs. Signs and the locations of signs shown on the Site Plan are not approved by the Site Plan review process. 13. Locate all site amenities/structures such as seating, shelters, bicycle racks, trash receptacles/enclosures, gazebos, etc. 14. Show and dimension all landscaped areas and islands. 15. Show detention and water quality pond(s). 16. Show major drainage ways affecting the site and any 100-year floodplain on or adjacent to the site. 17. Locate and provide reception number for all existing and proposed easements. 18. Locate all existing and proposed Fire Lanes and Fire Hydrants. 19. Show the inside radius for 90-degree turns for all emergency access routes and/or hammer head. 20. Build-to analyses in the following format: Build-To Analyses Required Provided Primary Street - (provide street name) Total Build-To (min % within min/max) Zone Lot Street Frontage length Building length Alternatives provided (list alternatives here) ft ft ft Side Street - (provide street name) Total Build-To (min % within min/max) Zone Lot Street Frontage length Building length Alternatives provided (list alternatives here) ft ft ft Sheet 4 - Parking Plan Sheet(s) (if applicable) 1. Parking structure layout with dimensions for parking stalls and driveways. 2. Accessible spaces with sign location and accessible routes to elevators and building entrance. 3. Loading areas with dimensions. 4. Bicycle enclosure/structures. Sheet 5 - Utility and Grading Sheet 1. Existing and Proposed Structures, Streets, and Alleys. 2. Existing and proposed utilities and service lines, including water, sanitary sewer, storm sewer, gas, electricity, telephone, and cable television. 3. Existing and proposed fire hydrants (indicate distance to nearest fire hydrant). 9

4. Reference to the Book and Page numbers or the reception numbers of recorded easements together with the county and date of recording (any required easements must be recorded and referenced on the plan prior to approval of the plan). 5. All relevant dimensions related to the location of existing and proposed utilities, service lines, and easements. 6. Any Cross-Access and Emergency Exit easements. 7. Denver Fire Department Fire Flow Data Block: TOTAL FIRE FLOW REQUIRED FOR THIS SITE IS GPM MINIMUM @ 20 PSI RESIDUAL PRESSURE THIS FLOW MUST BE PROVIDED FROM A MINIMUM OF FIRE HYDRANTS INDIVIDUALLY, EACH FIRE HYDRANT MUST SUPPLY 1500 GPM MINIMUM @ 20 PSI RESIDUAL PRESSURE CODE USED FOR ANALYSIS: 2009 IFC WITH 2011 AMENDMENTS OCCUPANCY GROUP(S): CONSTRUCTION TYPE(S): FIRE FLOW CALCULATION AREA: THIS BUILDING IS/IS NOT FULLY SPRINKLERED Denver Water Standard Notes Standard Notes: 1. Each fire hydrant must supply 1500 GPM minimum at 20 psi residual pressure. 2. Water plans for this project must be submitted to DW for review approval separate of the DRC process. 3. An approved DW backflow preventer is required for firelines, commercial, multi-family dwellings and irritation. 4. Meter locations must be approved by DW. 5. Developer is responsible for all necessary system modifications needed to meet the required fire flows. 6. All existing taps on the site that are not used must be cut-off at the main and inspected by DW. This will be done at the developer s cost. 7. System Development valve for replacement taps will be given according to current Operating Rules. 8. If a water easement is required on a site, this easement will be granted to DW by separate document. 9. Landscaping depicted in future water easements must comply with restrictions contained within the standard water easement agreement. 10. Each independent structure must have its own separate tap, service line & meter. 10

11. Sub-metering is required on individual multi-family units as mandated by City Ordinance. 12. Soil amendment is required on all new water services. Certificate of Occupancy will not be issued without a soil inspection by DW. 13. Pre-submittal review is required prior to the formal water plan submittal to DW. Items required on utility plans: 1. Fire Flow Data and number of fire hydrants required. 2. Note if a fire sprinkler is required 3. Size and type of existing water main 4. Existing hydrants and hydrant numbers 5. Location of new tap, size, service line and meter location 6. Call out all existing taps, along with tap size and number. 7. Street name and nearest cross street 11

Grading Plan Required Information 1. Existing and Proposed Drainage Channels and Facilities, and Area Subject to a 100-year Flood. 2. Existing and proposed contour lines of the subject area shown in intervals not to exceed two (2) feet. Provide finished floor elevations for ground floor of existing and proposed building. 12

Sheet 6 - Landscape Plan 1. Show and label Zone Lot boundary lines as heavy solid black line. Provide dimensions. 2. Show building footprints of all existing structures to remain and all proposed buildings and structures. 3. Illustrate parking lot layout. Locate and dimension parking landscape islands, right-of-way medians, and other landscape islands. 4. Locate and dimension pedestrian sidewalk walkways. 13

5. Show landscape elements including fences, walls, and berms, and all site amenities/structures such as seating, shelters, bicycle racks, trash receptacles/enclosures, and gazebos. 6. Illustrate planted areas identifying name, size and quantity of material to be used. 7. Provide planting details, including typical methods of planting, minimum required mulch materials and depths, underlayments, etc. (Refer to the City Forestry website for information). 8. Show all three sight distance triangles. 9. Show location of all existing and proposed signs. Signs and the locations of signs shown on the Landscape Plan are not approved by the Site Plan review process. 10. Provide the number of existing trees, trees to be removed and proposed trees. 11. Provide analyses for how the required 5% of the parking lot landscaping requirements have been met ( if applicable). 12. Provide a landscape legend in the following format ( include only those species that will be planted on this site): Symbol Quantity Botanical Name WC 6 Catalpa Erubescens Common Name Western Catalpa Size 3 Caliper Notes BS 7 Picea Ponderoza Ponderosa Pine 6 ft Sheet 6 Architectural Building Elevations Sheet 1. Show Zone Lot lines identifying building setbacks. Show upper story setbacks. 2. Show View Plane line. 3. Show Base Plane (for projects reviewed under the new code). Refer to Section 13.1.3 of the DZC for definitions and rules. Show height from the Base Plane to highest part of the structure. Show encroachments into the maximum allowable building height. 4. In zone districts with bulk planes, show bulk plane originating from existing grade and any encroachments into the bulk plane. 5. Show actual roofline and the top of the parapet (for flat roofs). Provide the parapet height. 6. Show height of the rooftop mechanical equipment and how this mechanical equipment will be screened. 7. Identify clear glazing and provide dimensions for all windows. 8. Show all projecting elements such as cantilevered floor area, balconies, bay windows, etc. 9. Identify all building materials. 10. Show zone of transparency and provide transparency analyses in the following format: Ground Story Activation (Transparency) Required (min) Provided 14

Primary Street - (provide street name) Total Transparency (%) Building Length ft and % Clear glazing ft and % Alternatives ft (List alternatives here) Side Street - (provide street name) Total Transparency (%) Building Length ft and % Clear glazing ft and % Alternatives ft (List alternatives here) Sheet 7 - Photometric Plan 1. Show location of all freestanding and wall mounted exterior lighting. 2. Provide information about type (light source). 3. Show photometric study on plan. 4. Show summary of photometric study including min, max, and average number of footcandles. 5. Show details of all light fixtures, including pole heights as measured from the ground. Sheet 8 Site Development Plan Details (Optional, all details may be shown on other sheets) 1. Show trash enclosure design details (elevations). 2. Show garden wall and fence details. 3. Provide other details as required. 15