Reliable on land or sea. UL 1500 Ignition proof. ABYC compliant. High interrupt capacity. Mechanical Products Company



Similar documents
2 p o l e p r o t e c t i o n. S w i t c h / C i r c u i t Protector t o 3 0 A m p. S e r i e s 2 4. C o u n t o n i t.

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

I N N O V A T I VSEO L U T I O N I SN S E N S O R SA N D C O N T R O L S. Precision Products Aircraft Circuit Breakers

AZ420 MINIATURE GENERAL PURPOSE RELAY

UTS discrete wire sealing

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Thermal-Magnetic Circuit Breaker M1-..

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE

Universal MATE-N-LOK Connectors

Circuit Breakers. NRC Series. NRC Series

Magnetic Circuit Protectors 39. Configurations 44

Model Number Structure

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Model Number Structure

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

.093 [2.36] Commercial Pin and Socket Connectors

SPST-NO SPDT DPST-NO DPDT

SIL Resistor Network. Resistors. Electrical. Environmental. L Series. Thick Film Low Profile SIP Conformal Coated Resistor Networks RoHS Compliant

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

User s Manual Before using the inverter, you need to read and save the safety instructions.

ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics

AMP Standard Terminals and Splices. RoHS. Ready

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

How To Drive A Compact Serie 1

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

How To Read A Pipe From A Sensor

DUCT SMOKE DETECTOR D4120

Liquid Leakage Sensor Amplifier

Electronic overload relay EF65, EF96 and EF146

650W Single Output Power Supply

SPST-NO SPDT DPST-NO DPDT

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

SOURIAU s discrete wire sealing

Technicaldata General

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

HMI display Installation Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Advantium 2 Plus Alarm

Product Specification instalert Rapid Messenger Variable Message Sign

Electronic overload relay EF19 and EF45

C ole s quality Open Frame Instrument Rotary Switch provides low

RY2 miniature industrial relays

Solid-State Timer H3G

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Knob Potentiometer with Switch

CQM1-SF200/CS1W-SF200

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

L304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR

Battery Model: 25 Part Number: Nominal Voltage: 12 volts NSN: Number applied for, product currently available

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology

Surface Mounting Relay

Terminal Cleaning and Protection

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

12V/15.0A SLA Battery Charger Specification

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

Mini USB and USB 2.0-IP67 Connector System

Manual Switches Series 2 Pushbutton Switches and Indicators

400 Series Buccaneer BUCCANEER POWER. bulgin

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

40.3. Control Relays and Timers

Electrical Safety Products

2S-Series Sub-Miniature Toggle Switches

STB Series Enclosures

RFI/EMI TELEPHONE FILTERS

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Telephone- and leased line modem for industrial applications TD-36

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

TTC-IIS Series Up to 11 LPM Free Flow

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

SMA Interface Mating Dimensions (Per MIL-STD-348)

IntesisBox KNX LG Air Conditioning

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

AP Series Industrial Pushbutton Switch

Diesel Engine Driven Generators Page 1 of 6

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers

TF2 Series Miniature Snap-acting Switches

SMA Connectors. RF Coax Connectors. Product Facts

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Surface Mounting Relay

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Transcription:

Reliable on land or sea. UL 1500 Ignition proof. ABYC compliant. High interrupt capacity. Series 18. Count on it. Mechanical Products Company

The Series 18 from. Count on it. Wherever it goes. Clearly Specified Protection. Available in 16 standard ratings (2-60A), the Series 18 from expands the specified performance capabilities of a classic circuit breaker design. Electrical, mechanical and environmental specifications have all been defined and validated through testing to the requirements of the American Boat and Yacht Council (ABYC), the US Coast Guard (USCG), the Society of Automotive Engineers (SAE), Underwriters Laboratories (UL) and various Military Standards. Robust Design for Harsh Environments. The Series 18 was designed for the harshest of environments. The weatherproof and ignition proof characteristics are especially well suited to applications in Marine, Heavy Equipment, Trucks, Buses and Battery Chargers. All materials for the Series 18 were carefully chosen for resistance to UV and flammability. Equipment that must perform in the most demanding environmental conditions relies on the Series 18. The Series 18 is designed to be fit and form compatible to previously available devices, while providing enhanced performance. Series 18 Physical Configuration The Series 18 uses a doublebreak design to achieve increased short-circuit interruption capability. The push-to-reset actuator is trip-free, ensuring the Series 18 cannot be forced to continuously maintain a closed circuit if an overload condition exists.

Series 18 Physical Configuration 1.189 (30.2).630 (16.0) Typical Envelope Dimensions Inches (mm).890 (22.6).421 (10.69) 45 White Amp Rating Stamp 50 1.575 (40.0) 2.00 Dia. (50.8) #10 Mounting Option Shown.453 Dia. Max. (11.5) Button Height.370 (9.4).480 (12.2) Series 18 Style 0 Series 18 Style 1 1.189 (30.2) See Terminal Options Below Series 18 Terminal Options 1.265 (32.13).387(9.83) Ref. 1.265 (32.13).387(9.83) Ref. Two screw terminal options are available for the Series 18 Style 0: #6-32 (for 2-10 amp ratings only) and #8-32 (for 12.5-40 amps). In addition,.250 quick connects are available for ratings up to 25 amps. 1.109 (28.17).642 (16.3) 1S & 2E (offset) 2-10 Amps, Style 0 only 1S = Offset 6-32 Screw Terminals 2E = Offset 8-32 Screw Terminals 1.109 (28.17) 2E (in-line) 12.5-40 Amps, Style 0 only In-Line 8-32 Screw Terminals.906 (23.0) Series 18 Style 1 is available with #10-32 stud terminals. A 2T 1.221 (31.0) 3T 1.345 (34.2) B.325 Ref. (8.3).449 Ref. (11.4) 1.316 (33.43) 1.316 (33.43) A.438 (11.13) Ref..438 (11.13) Ref. B.642 (16.3).906 (23.0).764 (19.4).312 Ref. (7.93) 1Q (offset) 2-10 Amps,Style 0 only Offset.250 Quick-Connect Terminals.312 Ref. (7.93) 1Q (in-line) 12.5-25 Amps, Style 0 only In-Line.250 Quick-Connect Terminals 2T & 3T 12.5-60 Amps, Style 1 only #10-32 Threaded Stud Terminals

Series 18 Typical Trip Curves 10000 1000 TRIP TIME IN SECONDS 100 10 1.0 18 2-10 Amps TRIP TIME IN SECONDS 1000 100 10 1.0 18 12.5-60 Amps 0.1 0 200 400 600 800 1000 PERCENT OF RATED CURRENT (at 25 C) 0.1 0 200 400 600 800 1000 Series 18 Operating Characteristics Minimum Ultimate Trip The Series 18 Style 0 offers a minimum ultimate trip of 100% of rated current at 25ºC / 77ºF, while Style 1 offers a minimum ultimate trip of 110%. Maximum Ultimate Trip The Series 18 Style 0 offers a maximum ultimate trip of 135% of rated current at 25ºC / 77ºF, while Style 1 offers a maximum ultimate trip of 143%. Overload Trip Time Data (seconds at 25ºC) Current Rating 200% 400% 1000% 2-10 Amps 4-150 1.2-20 0.3-2.5 12.5-60 Amps 6-70 0.6-5 0.1-0.7 Voltage Drop The Series 18 Style 0 has a maximum voltage drop of 0.8V at rated current. The Series 18 Style 1 has a maximum voltage drop of 0.25V at rated current. Typical Ambient Temperature Correction Factor -65ºF -54ºC 0 32 77 100 140 165-17 0 25 38 60 74 Style 0 0.83 0.87 0.93 1.00 1.11 1.25 1.66 Style 1 0.81 0.88 0.92 1.00 1.10 1.22 1.47

Series 18 Specifications Standard Amp Rating Series 18 can be specified in current ratings of 2A, 3A, 5A, 8A, 10A, 12.5A, 15A, 17.5A, 20A, 25A, 30A, 35A, 40A, 45A, 50A or 60A. Termination Options #6-32 screw 2-10 A.250 quick connect #8-32 screw 2 10 25 40 60 2-25 A Ampere Rating 2-40 A #10-32 stud 12.5-60 A (Optional terminal hardware included as required.) Voltage Ratings The Series 18 is rated at 120VAC and 32VDC. Vibration The Series 18 is rated at 10g per MIL-STD-202, Method 204, Test Condition A. Shock The Series 18 is rated at 100g per MIL-STD- 202, Method 213, Test Condition A. Corrosion (Salt Spray) The Series 18 conforms to MIL-STD-202, Method 101, Test Condition A for 96 hours at 5% salt spray. Mounting Options Panel mounting options include both throughhole inserts for #10-32 thread clearance and #8-32 threaded mounting inserts. Interrupt Capacity Series 18 Style 0 & 1 tested per: ABYC E11: 3000A (32VDC and 120VAC). UL 1077: 3000A (32VDC and 120VAC). SAE J553 compliant. Series 18 Style 1 also tested per: ABYC E11: 5000A (32VDC). UL 1077: 5000A (32VDC). Resettable Overload Capacity The Series 18 may be reset at a minimum of ten times rated value. Ignition Proof The Series 18 conforms to USCG Title 33, CFR, Section 183.410(a) per UL1500 testing. Weatherproof The Series 18 conforms to the weatherproof requirements of SAE J1428. Humidity The Series 18 conforms to MIL-STD-202, Method 106, for 240 hours at 95% relative humidity. Weight Approximately 39 grams Inrush Capacity The Series 18 will not trip at 35X rated capacity for ½ cycle (0.008 sec.). Endurance At 32VDC the Series 18 meets the SAE J553 endurance requirements of 100 cycles at 6X rated value and 200 cycles at 2X rated value. Dielectric Strength All Series 18 models have a dielectric strength rating of 1500VAC. Regulatory Compliance Summary Interrupt Capacity tested per: ABYC E11, UL 1077 & SAE J553. Endurance per: SAE J553. Dielectric Strength per: UL 1077 Vibration per: MIL-STD-202. Shock per: MIL-STD-202. Corrosion per: MIL-STD-202. Ignition Proof per: UL 1500. Weatherproof per: SAE J1428. Humidity per: MIL-STD-202.

Series 18 Mounting Considerations Recommended Mounting #10 only T0 #10 w/locking Nut E1.570 (14.5) Dia. Dia. "A" (2 Holes) 40 I.D..220 (5.6) 1.575 (40.0) 40 1.575 (40.0) I.D..220 (5.6).787 (20.0) 1.575 (40.0) 421 (10.69).590 (15.0) Mounting Code Panel Mounting Options Size Dia. Optional Screw Available* Clearance Dia. A T0 #10.220 (5.6) - For #10 screw #10 s (2) Self-locking nuts (2) E1 #10.220 (5.6) 8-32 For #8 screw *for.020 to.150 panel thickness Series 18 Part Numbering Guide Color and Marking 0 = Red button 1 = Red button w/45 o white amp-stamp A = No button (Auto-Reset) Ampere Rating 0020 = 2.0A 0150 = 15.0A 0350 = 35.0A 0030 = 3.0A 0175 = 17.5A 0400 = 40.0A 0050 = 5.0A 0200 = 20.0A 0450 = 45.0A 0080 = 8.0A 0250 = 25.0A 0500 = 50.0A 0100 = 10.0A 0300 = 30.0A 0600 = 60.0A 0125 = 12.5A (Additional ratings available) P/N: 18 - - - - - Series Number 18 = Series 18 Circuit Protector Style 0 = 2-40 Amps, Standard Calibration 1 = 12.5-60 Amps, High Ambient Actuation 0 = Manual Reset - Weatherproof 1 = Auto Reset - Weatherproof Mounting Mounting Hardware T0 = #10 eyelet hole only 0 = No mounting hardware E1 = #10 eyelet hole with 1 = Std. 8-32 screw for E1 lock-nut attached self-locking nut (for.020 to.150 panel) Terminals Terminal Hardware (bulk packed) 1Q = 0.250 quick connect terminals (2-25A, Style 0 only) 0 = No terminal hardware 1S = 6-32 screw terminals (2-10A, Style 0 only) 1 = 6-32 screws & lockwashers for 1S terminals 2E = 8-32 screw terminals (2-40A, Style 0 only) 2 = 8-32 screws & lockwashers for 2E terminals 2T = 10-32 threaded.325 stud (12.5-60A, Style 1 only) 3 = 10-32 nuts & lockwashers for 2T & 3T studs 3T = 10-32 threaded.449 stud (12.5-60A, Style 1 only) (see Terminal Configurations on page 2) Mechanical Products Company 1824 River Street Jackson, MI 49202 phone 517 782 0391 fax 517 788 6773 www.mechprod.com 04F