V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual



Similar documents
swimming pool accessories

RESERVDELSLISTA NORMFINISH DP14

SunMaxx Solar Filling Station Operating Instructions

Installation Instructions

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Dehumidifier D 850E. - Instruction manual version 02

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

CENTRAL AIR CONDITIONER SPLIT SYSTEM

HERZ-Thermal Actuators

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

ECOCIAT. Domestic hot water heat recovery unit

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Installation, operation and maintenance manual TX 35A

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock

OPL BASIC. Dosing System for Professional Laundry machines. Contents

LED 18W/12V SWIMMING POOL LIGHT WITH REMOTE CONTROL INSTALLATION AND OPERATING INSTRUCTIONS

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

MANTA Piston Distributor for Oil and Fluid Grease

Air Conditioner Water Heater Model ACWH18

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

COIL PAC. Subec AB, Sprängarvägen 16, Saltsjö-Boo, Sweden, Tel.: , Fax: , info@subec.se

GenStore Archive Cabinet

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

Installation Instructions For Slider Casement Air Conditioners

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Conlift1, Conlift2, Conlift2 ph+

THERMA-TUBE preinsulated pipes and fittings Catalogue of products

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Hose and Tube Fittings Series 1-3

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

Installation Instructions

How To Read A Pipe From A Sensor

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Oil and Coolant Circulating Heating System. Model - OCSM

H41 Electrical Stage Aft Air Conditioner Unit Installation

ALMATEC Series CX CX 10 CX 130

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Terminal Boxes Series 8146

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

Installation Instructions

1. Description. 2. List of Accessories included A B C F G H

1 DESCRIPTION OF THE APPLIANCE

Overheating limit control

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Original instructions Protective tube for Orion1B and Orion2 Orion WET-xxx and Orion WET-Kxxx

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

MDT5N25 & MTD5N40 SERVICE PARTS

SWIMMING POOL HEAT PUMP

SMD Rework Station TABLE OF CONTENTS

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

Subminiature Load Cell Model 8417

Please also see 10 golden rules for correct Saniflo installation on

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

CEILING CASSETTE FAN COIL UNIT

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

Oil - kerosene burners

COMMERCIAL GAS DRYER

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

building applications copper - redefined

Fiberstars Mini Lighted Laminar Flow Fountains

CutMaster Major External Replacement Parts

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

Power consumption (kw)

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Reverse Cycle Inverter Split System Air Conditioner

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

SERVICE MANUAL Order No.WH0911S001V0

Vario Line. Spring pressure single-disc brake H00

HP switch LP switch Discharge thermo Comp. Surface thermo

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Digital inductive conductivity transmitter

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Tape Wound, Split Core and Ebony Current Transformers

Saferand easierinstallation

RESOL DeltaSol A. Mounting Connection Operation Examples. Manual

Accessory Manual Ventilation Section Model Comfort Circle

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Installer s Guide 18-AH39D1-13

Installation instruction CASAFLEX - Connecting piece DN 100

Elektromotoren und Gerätebau Barleben GmbH

Transcription:

V - JET Counteflow System V-JET Counterflow System Installation and Operation Manual

1. System Installation By purchasing the V - JET counterflow system you have obtained high-quality product, which will make the moments spent in a swimming pool more pleasant. V-JET is supplied with NEW BCC motors of input power 2.2kW ; 3.0kW and 4.1kW in 230V as well as 400V versions. It implies that you may chose the motor acc. to voltage used at your swimming pool. The electric pump should be installed as close to the swimming pool as possible to achieve maximum power and prevent losses due to friction. Original diameters of PVC accessories delivered with the system should be followed in any case. Positioning of the pump at a distance exceeding 15 m from the swimming pool is not recommended. The NEW BCC series pumps forming part of the system are not self-priming, thus they shall be installed under the water level. The system technological space shall be properly vented, even with fan as needed, to prevent water precipitation (condensation). It this way proper operation of the V-JET system is achieved. 2. Fixing of Counterflow Body On installation of the counterflow body please note that it must be installed in position shown on Fig. 1. Both discharge pipe of diameter 75mm and suction pipe of diameter 90mm shall be positioned in vertical position, as the discharge side (diameter 75mm) must be above the suction side (diameter 90mm), see Fig. 1. Position the counterflow system in such manner that the nozzle hole centre is ca 30cm below the water level (see Fig. 1). The instruction are of critical importance and they must be adhered to during the system installation, otherwise proper operation of the counterflow cannot be guaranteed. Legend: water level; discharge; suction

Installation to concrete pool; concrete pool Fig. 2a Installation to concrete pool with foil; concrete; foil; seal no. 19 (another seal maz be fitted from the foil other side) Fig. 2b Installation to panel or sheet pool with foil Installation to prefavricated (laminated or panel or sheet with hole diam. 270 mm; foil polypropylene) pool; pool wall Fig. 2c Fig. 2d

3. Installation of Counterflow Body into Concrete Stick the hoses (pos. 21 Fig. 3) to the counterflow body (pos. 20 Fig. 3) and pass them into the technological space (well). Protect the hose ends against concrete. Install the counterflow body pos. 20 Fig. 3 acc. to Fig. 2a into the hole in concrete wall or cladding for concreting without flange and seals. As soon as the body is fixed into the wall, follow the instructions specified in section 4 and install pneumatic and air lines. 3.1 Installation of Counterflow Body into Concrete Pools with Foil Installation of the counterflow body into the concrete pool wall with foil shall comply with instruction specified in section no. 2 and 3. After fixing of the counterflow body to the pool wall you may install the counterflow seals and flange, Fig. 2b. Tighten the seals (pos. 18, Fig 3) to the counterflow body (pos. 20, Fig. 3) by means of 2 screws (pos. 19, Fig. 3); please note that the pool foil may be positioned between the two seals (Fig. 2b). Finally install the flange (pos. 17, Fig. 3) and tighten the screws (pos. 16, Fig. 3), only then cut the foil from the flange inner side. Install the air and pneumatic lines acc. to instructions given in section 4. 3.2 Installation of Counterflow Body to Panel or Sheet Pool with Foil Prepare a hole of diameter 270mm in the pool wall in such manner that the nozzle centre is ca 30cm below the water level, s describe in section 2 and Fig. 1. Fit the counterflow body pos. 20 Fig. 3 from the pool inner side into the prepared hole. Fix the body into the pool wall as shown on Fig. 2c by means of self-cutting screws pos. 19 Fig. 3. Tighten seals (pos. 18, Fig. 3) to the counterflow body (pos. 20, Fig. 3) by means of 2 screws (pos. 19, Fig. 3), install foil, then fix the flange (pos. 17, Fig. 3) and tighten the screws (pos. 16, Fig. 3), only then cut the foil from the flange inner side. Install the air and pneumatic lines acc. to instructions given in section 4. 3.3 Installation of Counterflow Body to Prefabricated (Laminated or Polypropylene) Pool Cut a hole of diameter 230mm in the pool wall in such manner that the nozzle centre is ca 30cm below the water level, s describe in section 2 and Fig. 1. Stick the seals (pos. 18, Fig. 3) from the pool wall outer side and prepare holes for 16 screws of the flange (pos. 16, Fig. 3) acc. to this template. Prepare the counterflow body (pos. 20. Fig. 3) from the pool outer side and fix the flange (pos. 17, Fig. 3) with screws (pos. 16, Fig. 3) from the inner part as shown on Fig. 2d. Install the air and pneumatic lines acc. to instructions given in section 4.

4. Installation of Air and Pneumatic Lines Installation of Air Lines: Stick the reduction piece (pos. 22, Fig. 3) to the hose serving as the air line and install the check valve (pos. 23, Fig. 3). It is important to locate the check valve to the technological space wall to prevent suctioning of dirt (see Fig. 6). Finally fix the flexible tube (pos. 13, Fig. 3) by pressing it into the nozzle inside the counterflow body (see Fig. 4). Installation of Pneumatic Lines: This line consists from hose (pos. 21, Fig. 3) serving as protecting sleeve for pneumatic switching hose. Position the pneumatic switching hose into the pneumatic line (hose pos. 21, Fig. 3) and lead its end through the hole in the counterflow body (pos. 20, Fig. 3), tighten it by the penetration sleeve (pos. 14). The hose end (pos. 2, Fig. 3) shall be connected to the pneumatic switch (pos. 1, Fig. 3) located at the face of the V-JET counterflow system. Fig. 3

Fig. 4 5. Fixing of Counterflow Face Cover Complete face cover is supplied in assembled state and includes parts pos. 1 to 12 (see Fig. 3). An exception is transparent pneumatic hose (pos. 2), which yet forms part of the counterflow body (see Fig. 4). Installation procedure of face cover is as follows: - Connect hose pos. 2, insert it to the mandrel of pneumatic switch (pos. 1, Fig. 3). - Connect hose pos. 13, insert it to the nozzle at the face cover. - Connect the complete face cover with the counterflow body, note that the ring (pos. 12) shall be inserted into neck of the outlet hole (diameter 75mm). - Tighten four screws (pos. 3, Fig. 3). As soon as they are securely tightened, the face cover is ready to use.

6. PVC Set for Installation of Suction and Discharge Pipes V-JET includes a PVC set for installation of suction pipe (diameter 75mm) and discharge pipe (diameter 75mm), see table below. PVC Set Pos. DESCRIPTION Quantity 1 2 3 Reduction piece 90x75mm Ball valve - diam. 75mm 90 grade bend - diam. 75mm 1 2 3 Installation of Discharge and Suction Pipe: Prepare tubes of diameter 75mm acc. to disposition in technological space (well) for counterflow and stick the suction and discharge pipes acc. to Fig. 5 Fig. 5 A B C 165mm 1005mm 600mm

7. Minimum Requirement to System Installation Space Before the V-JET system is installed, please consider dimensions of technological space (well), where the counterflow is to be located. Make use in advance that there will be no spatial problems during the pump installation. Minimum recommended sizes of the technological space needed for installation of the system - see Fig. 6 + table. Width Length A Height B 750 1420 900 Legend: water level; air suction; venting; to electric panel Fig. 6

8. V-JET System Operation and Adjustment As soon as the V-JET is installed, the swimming pool is place of your rest and fun due to pleasant excitement from the flow of water or aired water generated by the unit. The counterflow is started from the pool by pressing of pneumatic switch (pos. 1, Fig. 7 ). The started counterflow supplies: only water flow, or flow of water with air. It depends on adjustment of front nozzles (see Fig. 7). Only water flow: Maximum water flow is achieved by turning of inner nozzle (pos. 2, Fig. 7) CCW. The water flow is limited by turning the nozzle CW. Flow of water with air: Turn the outer nozzle to adjust/limit the air flow (pos. 3, Fig. 7). Legend: conterflow nozzle detail; maximum flow; minimum flow Fig. 7

9. V-JET Counterflow Part List Pos. Description Quantity Pos. Description Quantity 1 Pneumatic switch 1 pc 13 Flexible hose (air) 1 pc 2 Pneumatic hose 7m 14 Pneum. hose penetration sleeve 3 Front screw 4 pcs 15 Penetration O-ring 1 pc 4 Counterflow face cover 1 pc 16 Flange screw 16 pcs 5 External ball 1 pc 18 Seals 2 pcs 6 Air flow control nozzle 1 pc 17 Flange 1 pc 7 Support ring 1 pc 19 Counterflow self-cutting screw 4 pcs 8 Water flow control nozzle 1 pc 20 Counterflow body 1 pc 9 Inner ball 1 pc 21 Air and pneumatic line hoses 2x1m 10 Nozzle self-cutting screw 3 pcs 22 Reduction piece 20x 1 / 2 ex 1 pc 11 Nozzle fitting 1 pc 23 Air suction check valve 1 pc 12 O-ring 1 pc 1 pc Fig. 8

10. Electrical Installation - WARNING The electrical installation works should be performed by authorised technician acc. to generally binding regulations and standards. Main power supply voltage shall correspond to the value specified on label fixed to each equipment. All system metal components must be bonded (grounded). Electric characteristics / regulations of circuit breaking elements shall comply with characteristics / regulations applicable for motor, which is to be secured with expected operating conditions. All instructions specified by the manufacturer shall be adhered to (see data on label). At devices with three-phase motor, the clamps in the termination board between the motor windings must be properly positioned (star connection). Input and output wires from the distribution box must be lead through the penetration elements preventing entry of humidity and dirt into the distribution box. The wires shall be fitted with proper connecting terminals / clamps. The electric-pneumatic panel shall be installed in dry location above the water level and at distance to 7m from the pneumatic switch at the counterflow face. The pneumatic hose (pos. 2, Fig. 3) is intended for connection to the electric-pneumatic switch at the electric-pneumatic panel (switchboard). It must be checked, whether the hose is not bent at any point. The electric-pneumatic panel consists from following parts: 1 Motor protection - 1 Electric-pneumatic switch - 1 Control fuse. All these parts should be installed in water-proof plastic box with insulation protection IP55. Note: Detailed information on installation, protection and maintenance see Electric- Pneumatic Panel Instruction Manual. Fig. 9 Fig. 10 FM - Control Fuse, DM - Motor Thermal Protection, I.N. - Electric-Pneumatic Switching Unit, C Contactor

11. V-JET Counterflow Pump The V-JET counterflow is fitted with NEW BCC pump in single-phase variant for 230V and in three-phase variant for 400V, electric input power 2.2kW ; 3.0kW and 4.1kW. Dimensions see Fig. 11, performance characteristics see Fig. 12 Fig. 11

Fig. 12