e-vlbi Updates in CVN



Similar documents
Data transport in radio astronomy. Arpad Szomoru, JIVE

WAJIMA, Kiyoaki ( 輪 島 清 昭, KASI)

Voice Internet Phone Gateway

Systems and Networks for Astronomy. Marco de Vos ASTRON Director of R&D

Fujitsu World Tour Human Centric Innovation. The Future of the Datacenter. Ayman Abouseif VP Product Marketing. 0 Copyright 2015 FUJITSU

Near real-time monitoring of UT1 with geodetic VLBI

The old Internet. Software in the Network: Outline. Traditional Design. 1) Basic Caching. The Arrival of Software (in the network)

DiFX at IRA: cluster, network and dbbc testing

short introduction to linux high availability description of problem and solution possibilities linux tools

Ring Protection: Wrapping vs. Steering

e-vlbi Development at Haystack Observatory Alan R. Whitney MIT Haystack Observatory

UNIFIED PERFORMANCE MANAGEMENT

Big Data and Storage Management at the Large Hadron Collider

Pacnet Premium Dedicated Internet Access Dedicated Internet Access for Web-Centric Enterprises

Schedule R Teleconferencing Service

CISCO PIX SECURITY APPLIANCE LICENSING

Fast, scalable and CAPEX-free servers in Pacnet's advanced data centers PACNET HARDWARE-AS-A-SERVICE

How To Build A Network For Storage Area Network (San)

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Gfarm: Present Status and Future Evolution

POSIX and Object Distributed Storage Systems

Sun 8Gb/s Fibre Channel HBA Performance Advantages for Oracle Database

Benefits. Product Overview. There is nothing more important than our customers. DATASHEET

Lightpath Planning and Monitoring

Cisco CNS NetFlow Collection Engine Version 4.0

Introduction to CERNET+ IPv6 Cloud Services Platform Initiative

Datasheet Fujitsu ETERNUS LT20 S2

FACT SHEET Global Direct Selling

Mobility. Versatility. Performance. Storage Solutions with Thunderbolt Technology

AMI-Partners. SMB Managed Services Assessment Opportunities & Actionable GTM Insights

Flexible Cloud Services to Compete

Remote Copy Technology of ETERNUS6000 and ETERNUS3000 Disk Arrays

Designing HP SAN Networking Solutions

Pluggable Optics for the Data Center

K2 LxO RAID Storage Systems

Security and Communication. Because Intercom doesn t stop at the hardware level Software Intercom Server for virtualised IT platforms

Advanced features on Ethernet networks. Fulvio Risso Politecnico di Torino

African-European Radio Astronomy Platform Africa-EU Cooperation Forum on ICT. Addis Ababa, Ethiopia 3 December 2013

The Murchison Widefield Array Data Archive System. Chen Wu Int l Centre for Radio Astronomy Research The University of Western Australia

WD Hard Drive Interface Guide

IMPLEMENTING GREEN IT

Campus Network Design Science DMZ

Building the Fibre Nation. Alberto Lotti Director Strategy, Solutions & Marketing Alcatel-Lucent Italy Cluster

Bring a Big World Closer

Performance Guideline for syslog-ng Premium Edition 5 LTS

CISCO CONTENT SWITCHING MODULE SOFTWARE VERSION 4.1(1) FOR THE CISCO CATALYST 6500 SERIES SWITCH AND CISCO 7600 SERIES ROUTER

THE PROXBOOK REPORT THE STATE OF THE PROXIMITY INDUSTRY Q All information in this report belongs tounacast AS

SKA. Hosting one of world s largest science infrastructures. Dr Jasper Horrell, SKA SA. IT Infrastructure and Broadband Summit, Cape Town, Aug 2014

GLOBAL EDUCATION PROGRAM

Science DMZs Understanding their role in high-performance data transfers

VERITAS Volume Replicator in an Oracle Environment

FACT SHEET INTERNATIONAL SERVICES GLOBAL INTERNET ACCESS (GIA)

Mobile Application Testing

Cisco Blended Agent: Bringing Call Blending Capability to Your Enterprise

SAP HANA Operation Expert Summit BUILD - High Availability & Disaster Recovery

Recent SmartMarket BIM Research by. McGraw Hill Construction. Stephen Jones Senior Director. January 8, 2014

NetFlow Feature Acceleration

How To Get A Strategic Value From Data

Cloud Fabric Overall Market Performance

Global Real Estate Outlook

SharePoint Performance Optimization

IPv6 measurement in CSTNET. CSTNET, CNIC, Sep. 2014

Quantum StorNext. Product Brief: Distributed LAN Client

Table of Contents. Introduction. Understanding PBX systems. Hosted PBX advantages. Features offered by a hosted PBX service

Network Storage AN ALCATEL EXECUTIVE BRIEF

Automated job scheduling

Windows Server 2012 R2 Hyper-V: Designing for the Real World

MANDATORY PROVIDENT FUND SCHEMES AUTHORITY

The Internationalization of Higher Education: Foreign Doctorate Holders in a Russian Academic Market as Agents of Transformation

Introduction to CERNET+ IPv6 Cloud Services Platform Initiative. CERNET Corp

Data Movement and Storage. Drew Dolgert and previous contributors

Fibre Channel Overview of the Technology. Early History and Fibre Channel Standards Development

Real-Time Data Access Using Restful Framework for Multi-Platform Data Warehouse Environment

Performance Optimisation

Report on Government Information Requests

Digital vs Traditional Media Consumption

GÉANT2. Otto Kreiter Network Engineering & Planning, DANTE

Project Community Network Planning

Axceleon s CloudFuzion Turbocharges 3D Rendering On Amazon s EC2

Electricity Disasters and Roles of Electrical Safety Inspection Associations in Japan

SPRACE Site Report. Guilherme Amadio SPRACE UNESP

PANDUIT Physical Layer Infrastructure Management. EMC Smarts Integration Module

3rd Party Audited Cloud Infrastructure SOC 1, Type II SOC 2, Type II ISO Annual 3rd party application Pen Tests.

Reporting practices for domestic and total debt securities

KFUPM Enterprise Network. Sadiq M. Sait

Large File System Backup NERSC Global File System Experience

SN A. Reference Guide Efficient Data Center Virtualization with QLogic 10GbE Solutions from HP

Scout 1U Rackmount Computer

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

Cisco IOS Telephony Services Survivable/Standby Remote Site Telephony

NFS SERVER WITH 10 GIGABIT ETHERNET NETWORKS

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

CISCO MDS 9000 FAMILY PERFORMANCE MANAGEMENT

Software-as-a-service Delivery: The Build vs. Buy Decision

High-Capacity, High-Throughput: New Satellite Systems Meet Big Oil s Big Data

An open and flexible cloud platform. Quickly build, deploy, and manage solutions across a global network of Microsoft-managed datacenters.

IT of SPIM Data Storage and Compression. EMBO Course - August 27th! Jeff Oegema, Peter Steinbach, Oscar Gonzalez

Bareos in Radio Astronomy Scaling up using Virtual Full Backups

...DYNAMiC INTERNET SOLUTiONS >> Reg.No. 1995/020215/23

AACSB International Accreditation and Joint Programs

Transcription:

e-vlbi Updates in CVN Shanghai Astronomy Observatory Chen Zhong AUT, Auckland, New Zealand IVTW 2015, 2015.11.23

Outline CVN e-vlbi Network CVN e-vlbi Applications Future

CVN e-vlbi Network Stations Sh Shanghai Sheshan, 25m, 1987 Ur Xinjiang Urumuqi, 25m, 1993 Bj Beijing Miyun, 50m, 2006 Km Yunnan Kunming, 40m, 2006 Tm Shanghai Tianma, 65m, 2013 Data Center Shanghai VLBI data processing center - C&C center of VLBI tracking system for CLEP, 2007 - IVS Correlator Center, 2012 - Scientific data processing: astrophysics, pulsar, History Started: 2006 Supported by CLEP Project 3

CVN e-vlbi Network QTT 110m TBD FAST 500m 2016 VGOS 13.2m 2016

CVN e-vlbi Sites Ur, XAO Sh, ShAO VLBI C&C Hall ShAO Bj, NAOC Km, NAOC VLBI Center Server Room Tm, ShAO

Outline CVN e-vlbi Network e-vlbi Applications CLEP Phase I/II/III Shanghai IVS Correlator Conclusion

e-vlbi for CLEP VLBI Tracking and Measurement System Service for M&C system Phase I(CE-1), Phase II(CE-2/3/4), Phase III(CE-5T1/CE-5/6) Real-time Requirement Additional Function Receiving-recording-distributing data to hw/sw Correlators in data center Two data pipelines to make sure high reliability and availability 7

e-vlbi for CLEP Summary Mission Mode Network Line VLBI Raw Data rate Network Line Failover Realtime Requirement Realtime Performance CE-1 Near realtime Telecom/CNC (SDH 34Mb/s) CSTNET IP-VPN (100Mb/s) 16Mb/s Manually, >30m 10m <6m CE-2 Near realtime Telecom/CNC MSTP(100Mb/s) 32Mb/s Manually, >15m 10m <4m CE-3 Realtime Telecom/Unicom (SDH 155Mb/s) 64Mb/s Automatically, <3s 1m <40s CE-5T1 Realtime Telecom/Unicom MSTP(100Mb/s) 64Mb/s Automatically, <3s 1m <40s CE-5 Realtime Telecom/Unicom (SDH 155Mb/s) 128Mb/s Automatically, <3s 1m 2017 Long term period: Low network bandwidth for fringe testing Dedicated network fiber closed after mission

CE-3/5T1 e-vlbi High Availability Network Km, Ur, Bj, Sh, Tm Long Range Network Backbone is not so reliable OSPF+BFD protocol to detecting and switching backbone network link when accidental failure: switch time < 3s Network failovers times> 20 Buffer data for network link switching, then retransmit after link recover TCP Protocol Performance Tuning

e-vlbi Transfer System Stations CDAS Mark5B+ (2/station) SKD Script Control Modified Mark5B+ e-vlbi software Two level buffer: HW/SW Data center Clock/Source Setting Sending Thread Hardware Correlator Data Distribute Unit COST Servers (5+1)+DAS Data Receiving Data Distribution CDAS Mode Setting Real-time Sending Waiting end Recving Thread Buffer Sending Thread Storage NFS Software Correlator Ring Buffer MarkB+ Ctl DDU Protocol: TCP (UDP,IPv6) Control Script Control

e-vlbi e-vlbi Network flow

Outline CVN e-vlbi Network e-vlbi Applications CLEP Shanghai Correlator for IVS Conclusion

Shanghai Correlator for IVS IVS Correlator Center Bonn, Haystack, IAA, Kashima, Tsukuba, Washington, Shanghai (2012, Madrid, IVS GM Meeting) Data Processing DiFX CVN Software correlator: under development Data Transfer Internet based e-transfer: from most stations & correlators Disk Shipping: Kokee,

CVN Internet B/W Via CSTNET(Chinese Science&Technology Network, CAS) Network Service on Demand(email, phone ) IPv6 supported Bj Ur Km 150Mb Shared 100Mb Shared SHAO Seshan VLBI Center 4Mb ADSL XAO YAO China Telcom CSTNET XinJiang CSTNET KunMing 600Mb 2.5Gb CSTNET Beijing 2 2.5Gb 3.5G(2016) 1 2.5Gb 10Gb CSTNET HongKong Geant London 10Gb 622Mb LP 10Gb JIVE Internet2 USA Haystack DWDN 10Gb 10Gb 10Gb 10Gb SHAO Xujiahui CSTNET Shanghai EastAsia Japan Korea Sh Tm Australia New Zealand

Shanghai Correlator e-transfer data rate Country Institutes Network B/W To/From Shanghai Germany Bonn MPRiFR 900Mb/s 800Mb/s Japan NICT 10Gb/s 1Gb/s Japan GSI 10Gb/s 1Gb/s South Korea NGII 1Gb/s 800Mb/s Italy IRA 10Gb/s 800Mb/s South Africa Hartebeesthoek 10Gb/s 550Mb/s Australia University of Tasmania 10Gb/s 800Mb/s New Zealand Auckland University of Technology 10Gb/s 800Mb/s Brazil IPNE 1Gb/s 200Mb/s Netherlands JIVE 10Gb/s 1Gb+/s Russia IAA 1Gb/s 500Mb/s USA Haystack 1Gb/s 600Mb/s Malaysia University of Malaya 100Mb/s 90Mb/s

International e-vlbi Testing/Transfer CSTNET EVN:12 w/1.1gbps IVS:12 w/128mbps Sh/Tm ->JIVE 2015.4.17 e-evn Total: 1.5Gbps Sh:1Gbps Tm:0.5Gbps Sejong->Sh 2015.05 e-transfer

Future Deep space tracking system services CLEP Phase III (CE-5, CE-4 ), Mars exploration, etc Science observation e-vlbi EVN, VGOS, EVAN, IVS/AOV Device and Network CDAS2, VDIF Network bandwidth expansion, ipv6 usage e-transfer Status Web page, mpifr-bonn or own web Challenges Big volume data transfer: VGOS, SKA CVN - R&E backbone network bandwidth limitation: CSTNET, Km, Ur - Last mile to stations: Bj, FAST, QTT - Transfer Automatically e-vlbi/e-transfer

Thanks!