Power over Fiber. Technical Note



Similar documents
3mm Photodiode,T-1 PD204-6C/L3

Un-cooled Multimode Pump Laser Module for Telecom Applications

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

SECTION 13. Multipliers. Outline of Multiplier Design Process:

BUILDING INSTRUCTIONS

155 Mb/s Fiber Optic Light to Logic Receivers for OC3/STM1

Mounting Instructions for SP4 Power Modules

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

ILX Lightwave Corporation

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

Int863 INSTRUCTION MANUAL. IR Preheating System BASIC TROUBLESHOOTING GUIDE

Automotive Electronics Council Component Technical Committee

SYSTEM 4C. C R H Electronics Design

White Paper. Recommendations for Installing Flash LEDs on Flex Circuits. By Shereen Lim. Abstract. What is a Flex Circuit?

SYSTEM 45. C R H Electronics Design

Efficient and reliable operation of LED lighting is dependent on the right choice of current-limiting resistor

Troubleshooting accelerometer installations

MADP T. Non Magnetic MELF PIN Diode

MP-1919 XNOVA Cube TM SMD LED

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers

MASW TB. GaAs SPST Switch, Absorptive, Single Supply, DC-4.0 GHz. Features. Pin Configuration 1,2,3,4. Description. Ordering Information

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Single Photon Counting Module COUNT -Series

Assembly and User Guide

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

Mobile Data Power Model: MDP-25

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Adjustment functions for both span and shift have been incorporated

Fiber Optic Specifications

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

MADR TR. Quad Driver for GaAs FET or PIN Diode Switches and Attenuators. Functional Schematic. Features. Description. Pin Configuration 2

SDC15. TVS Diode Array for ESD Protection of 12V Data and Power Lines. PROTECTION PRODUCTS Description. Features. Mechanical Characteristics

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

MCR1900 Media Converter 19-Slot Chassis

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

HP UPS R1500 Generation 3

ESD/EOS ESD Electrostatic Discharge (ESD) Why Should I Care About Electrostatic Discharge?

Product Specification

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

The Do s and Don ts of Pressure Transducers

Subminiature Load Cell Model 8417

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

StorTrends 3400 Hardware Guide for Onsite Support

Series 510 Submersible Level Transmitters

Everline Module Application Note: Round LED Module Thermal Management

Grounding Demystified

Module Connectors and Cable Specifications

FIRERAY 2000 Installation Guide

Hand Crank Generator (9 May 05) Converting a Portable Cordless Drill to a Hand Crank DC Generator

Qualifying Photonics for the Space Environment

LDO03C/LDO06C/LDO10C

Technical Data. Dimensions

Amplified High Speed Fiber Photodetectors

Harvatek Surface Mount CHIP LED Data Sheet HT-380FCH-ZZZZ

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

CamSplice Assembly Manual

Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved

FlexFlash Instruction Manual Models SB FLXFLSH400W, SB FLXFLSH200W, SB FLXFLSHE400W, SB FLXFLSHE200W

SPECIFICATION. PART NO. : MT0380-UV-A 5.0mm ROUND LED LAMP. 3Northway Lane North Latham,New York

CLA LF: Surface Mount Limiter Diode

1W High Power Purple LED Technical Data Sheet. Part No.: LL-HP60MUVA

Electrical Overstress EOS

SLLP G PRODUCT DATASHEET. RoHS Compliant

Low Voltage, Resistor Programmable Thermostatic Switch AD22105

CHM-27 COB Arrays White LED

Acceptability of Printed Circuit Board Assemblies

TOSHIBA CCD LINEAR IMAGE SENSOR CCD(Charge Coupled Device) TCD1304AP

HP ProLiant DL165 G7 Server. Installation Instructions

The following document contains information on Cypress products.

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

4RU High Density Shelf Installation Instructions

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

XS-3525/8S-3. Preliminary DataSheet Version 2.02

0.45mm Height 0402 Package Pure Green Chip LED Technical Data Sheet. Part No.: LL-S160PGC-G5-1B

Auditing Contract Manufacturing Processes

SM712 Series 600W Asymmetrical TVS Diode Array

Fiber Optics and Liquid Level Sensors Line Guide

Three Channel Optical Incremental Encoder Modules Technical Data

Model GS Port Node 1 GHz with 40/52 MHz split

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

EasyNote TJ Series. Disassembly Manual

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

Transcription:

Technical Note Power over Fiber This technical note provides guidelines to ensure the proper operation and optimum performance of the JDSU power over fiber (PoF) product family, which consists of a photovoltaic power converter (PPC) and a photonic power module (). The combination of the PPC and the, hereafter referred to as the -K, can drive electronics in remote locations that are hazardous, electrically noisy, remote, inaccessible, or exposed to extreme weather. The -K consists of a local laser module with drive electronics connected to a remote PPC using multimode fiber. Electrical power from an external source is provided at the -K input to drive the diode laser. The PPC converts the optical power to electrical power at the remote location. Fiber lengths up to 1000 meters can be supported. The fiber pigtail provided with the -K is not intended for use directly with the PPC. Instead, a fiber patch cord, or jumper, should be inserted between the fiber pigtail and the PPC for optimum performance. It should have a minimum length of 10 meters (30 feet), preferably 50 meters (150 feet). Figure 1. -K with a selection of PPCs The -K is ideal for the following applications: Electronic circuits operating in: High RF, EMI, and magnetic fields High-voltage environments Extreme environmental conditions Sensors, gauges, and actuators Data communication transceivers GPS and wireless receivers Current transducers in high-voltage environments IGBTs in high-voltage environments Communication and sensor operational systems north america: 800 498-JDSU (5378) worldwide: 800 5378-JDSU website: www.jdsu.com

Technical Note: Power over Fiber 2 Operational configurations and reliability requirements depend on customer-specific applications and operating environments. Therefore, JDSU does not guarantee the reliability of the module attachment or control method within customer-specific applications and can only recommend good engineering practices. The end-user must confirm the final reliability and quality of any system in field applications. Topics addressed in this application note include: Photonic Power Module Photovoltaic Power Converter Fiber Contamination and Cleaning Power Supply and Control Precautions in Dealing with Laser Light Mounting Procedures Photonic Power Module The includes one diode laser and a driver control board with one 6-pin connector. The provides up to 2 W of optical power output, which is launched into multimode fiber (60/125 µm, NA 0.22) at nominally 830 nm wavelength. An extra heat sink for the module is required as described in the Mounting section of this note. Figure 2 shows the locations of the 4 screw holes with threads on the bottom of to attach the to a heat sink. Assembly Drawing Figure 2. mechanical drawing Module Operation External power must be applied to the module in accordance with the following table for proper operation of. The module accepts a supply voltage in the range of 6 V to 12 V and the overall power consumption for the module is no higher than 6.5 W. The power supply should comply with the Power Supply and Control section in this note.

Technical Note: Power over Fiber 3 Pinout Pin Description In/Out 1 Ground 2 Power (6V ~ 12V) Input 3 Laser Current Monitor Output 4 Module Enable Input 5 Laser Current Setting Input 6 Ground Figure 3. pin configuration and connector socket A voltage applied on pin #4 enables the module when the voltage is higher than 1.74 V and disables this module when the voltage is lower than 0.5 V. The output optical power can be adjusted through pin #5 with a voltage ranging from 0 to 1.25 V. The drive current increases linearly with the voltage applied on pin #5 until the voltage reaches 1.25 V, as shown in Figure 4. The drive current of the laser diode (I LD ) can be monitored by the voltage measured on Pin #3: where R SNS is 50 mω. I LD = V Pin3 /(20 R SNS ) Optical Power (W) 3 2.5 2 1.5 1 0.5 0 0 0.25 0.5 0.75 1 1.25 1.5 Setting Voltage (V) Driving Current (A) 3 2.5 2 1.5 1 0.5 0 0 0.25 0.5 0.75 1 1.25 1.5 Setting Voltage (V) Figure 4. Optical power and driving current The manufacturer of the 6-pin connector is Samtec p/n: IPL1-106-01-L-S-RA-K, and the recommended cable is MMSS-06-26-XX.XX-D-K-LUS, where XX.XX denotes the length of the cable. Refer to http://www.samtec.com/ for detailed schematics and drawings. Photovoltaic Power Converter The photovoltaic power converter (PPC) is a multi-segmented gallium-arsenide (GaAs) device. The output voltage is determined by the number of segments with each segment contributing roughly one volt. Output (open-circuit) voltages of 4 V, 6 V and 12 V are available in the PPC product family. The maximum electrical power output from a PPC is 500mW, depending on the input optical power, selected PPC, and load resistance. Two connector versions are available, FC and ST, with the FC being the most recommended by JDSU.

Technical Note: Power over Fiber 4 The PPC is typically characterized by the I-V curve shown in Figure 5. The open circuit voltage (VOC) and short circuit current (I SC ) denote the maximum voltage and current that can be extracted from PPC, while V MP and I MP correspond to the voltage and current where the maximum electrical power (V I) is obtained. The maximum output voltage is limited by the open-circuit voltage, and the maximum current output is limited by the short circuit current. However, the maximum power output is neither at the open-circuit voltage point nor at the short-circuit current point. In fact, at both of those points, the electrical power output is zero. Each point on the I-V curve corresponds to an operational point and a proper load resistance is required in order to maximize the power output. The slope of the load line in the figure determines the load resistance. I SC I MP Op point Load line P MAX Voltage V MP V OC Figure 5. PPC characteristic curves Figure 6 shows how the I-V curve evolves with different optical power input. Generally I SC is linearly proportional to the optical power whereas V OC varies logarithmically with input power. However, due to voltage losses stemming from resistance, V MP decreases for optical power levels higher than 500 mw whereas I MP linearly increases, as shown in Figure 7. 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 0.00 Current (ma) -20.00-40.00-60.00-80.00-100.00-120.00-140.00 50 mw 100 mw 250 mw 500 mw 750 mw 1.0 W 1.5 W 2.0 W -160.00 Voltage (V) Figure 6. Typical PPC-6E I-V curve with different optical power

Technical Note: Power over Fiber 5 6.50 6.30 6.10 5.90 140.00 120.00 100.00 V mp (V) 5.70 5.50 5.30 80.00 60.00 I mp (ma) V mp I mp 5.10 40.00 4.90 4.70 20.00 4.50 0.00 0 0.5 1 1.5 2 2.5 Optical Power (W) Figure 7. Typical PPC-6E VMP and IMP at different optical power Depending on the application, there are usually two ways of extracting power from the PPC. If constant output power delivery is preferred, one can design the load line to be around the value of V mp /I mp to extract the most power from the PPC with the input laser power to the PPC remaining constant. Another common mode of operation is to regulate the output voltage at a voltage level such as 5 VDC or 3.3 VDC. While this approach may sacrifice some conversion efficiency, it ensures no power variation with load resistance. Application Examples Overview A typical PoF application using the -K is shown in Figure 8. The is at one end of the fiber and the PPC at the other. Fiber adaptor Extension MMF PPC Customer electronics Figure 8. Typical PoF use of the -K In system design, the loss induced by the fiber adapter and MMF should be taken into account, especially when the PPC is located far from the. The pigtail fiber from the has a core/cladding diameter of 60 µm/125 µm and an NA of 0.22. The extension fiber should be chosen to be compatible with the pigtail fiber, such as 62.5 µm/125 µm and an 0.22 NA, to achieve the lowest connection loss. Other MMFs with larger core diameter and the same NA are also applicable. However, the PPC should be optimized (in terms of optical alignment) to the type of fiber to which it will be connected. Hence, to ensure the best alignment when the PPC is mounted in the receptacle the fiber type must be specified.

Technical Note: Power over Fiber 6 Parallel Connection In case a single -K cannot provide enough electrical power, two or more can be connected in parallel to increase the electrical power output. Each output from the PPC should be serially connected to a diode before feeding into a customer s electronics. The diode prevents reverse current into the PPC. The diode should have a low forward voltage to reduce the power losses induced by it. Figure 9 shows an example where two -K units are configured to supply the customer s electronics with almost double the electrical power. Fiber adapter Extension MMF PPC Customer Customer electronics Figure 9. Parallel connection example of two -K units Redundancy redundancy is recommended when a customer application requires a higher level of reliability. By using an optical power combiner, the optical output from the can be switched when a failure occurs. A power combiner is a fused optical fiber device which can combine multiple input optical power into a single fiber output. Fiber adapter Power combiner 2x1 Extension MMF PPC Customer electronics Figure 10. redundancy configuration example Optical Power Sharing It is possible to share the optical power from a single and feed it into multiple PPCs. This is especially cost effective when the electrical power requirement for each PPC is low. A power splitter (a fused optical fiber device which can split the input optical power evenly into multiple outputs) is used so that each of the PPCs can get a fraction of the optical power from the. Fiber adapter 1x2 Power splitter Extension MMF PPC Customer Customer electronics electronics Figure 11. Optical power sharing example

Technical Note: Power over Fiber 7 Precautions Safety The provides an output optical power of up to 2 W in the infrared region. Be sure to follow standard safety protocol for eye and skin for Class IV IR lasers. Electrostatic Discharge (ESD) ESD damage to a laser diode is induced from the rapid flow of electrical charge between two bodies at different potentials, either through direct contact or through an induced electrical field. ESD can cause catastrophic or latent damage and is of particular concern for the module s laser diode. Latent ESD damage, which occurs when the energy of an ESD event is below the critical level required to produce a catastrophic failure, can result in defects which propagate during module deployment resulting in catastrophic failure over time. A human body model (HBM) ESD test is used to determine the damage threshold of both and PPC, which are tested in accordance with GR-468-CORE section 5.22 (MIL-STD-883, method 3015.7). A number of industry specifications are available to make the work area ESD safe (for example, EIA-625, JEDEC 108-A). Below are common recommended guidelines for preventing ESD damages: Refer to and PPC specification sheets for ESD voltage ratings (2000 V max) Use shorting clips or foam on the PPC pins when the modules are disconnected from the operational circuit Ground operators, equipment, WIP transport carts/trays, modules or systems, and work surface to eliminate static electricity Only use confirmed ESD dissipative coatings/surface finishes on fixtures/tooling used to assemble the modules When manipulating lasers or modules, use ESD protective smocks, gloves and shoes/covers, dissipative bench-top mats and ESD protective flooring or matting Remove or control static generating sources to voltages below the specified maximum for safe ESD handling Install air ionizers as necessary for additional environmental control Use electrically grounded soldering irons for soldering the pump module to the mounting surface Use electrostatic shielding containers and antistatic or dissipative carriers

Technical Note: Power over Fiber 8 Fiber Contamination and Cleaning Fiber contamination is a key consideration for high-power laser modules. Fiber contamination, especially contamination with dark color, will cause a local temperature increase as it absorbs the dissipated cladding modes. Wear gloves when handling fiber Avoid any contamination of fiber No dark color contamination with an area larger than 100 µm x 100 µm is allowed within the first ~2 of buffer and should be avoided along the entire length of fiber Fiber cleaning materials and procedures shown here are for informational purposes only and are not meant to recommend, endorse, or discredit any existing procedures. It is recommended that users evaluate any procedure or product before using it in applications where damage or failure could result. As always, safety precautions must be exercised at all times when using glass, chemicals, and lasers. There are many materials commercially available for fiber optic cleaning. Some are marketed specifically for the fiber optic industry, while others are considered raw materials or generic in nature but can be used for the same purpose. Mounting Mounting topics include: Heat Sinks Thermal Interface Materials Fiber Handling Heat Sinks The design of the receiving heat sink is crucial to and PPC performance and reliability. The requires a heat sink and will fail catastrophically if operated without one. It is not compulsory, but it will benefit conversion efficiency if the PPC is mounted on a heat sink. The goal of the heat sink is to dissipate the heat from the package base with minimized thermal resistance. Heat sink performance is usually specified in terms of thermal resistance (Q): where: Θ S = Thermal resistance in C per watt T s = Heat sink temperature in C T a = Ambient or coolant temperature in C Q = Heat input to heat sink in watts Θ S = (T s T a )/Q Each thermal cooling application will have a unique heat sink requirement and frequently there will be various mechanical constraints that may complicate the overall design. Because each case is different, there is no single heat sink configuration suitable for all situations.

Technical Note: Power over Fiber 9 A well-designed heat sink in combination with a high-performance thermal interface material and package mounting technique should guarantee that the module case temperature does not exceed the maximum temperature specified for each series (refer again to the absolute maximum characteristics). Failure to keep a package base below the specified maximum temperature will lead to the pump module overheating and result in module damage. The following general heat sink guidelines are recommended: Mount the module on a heat sink with a surface finish of 0.8 microns or less The heat sink should be designed to handle at least maximum module heat dissipation through the life of the product. For total module power dissipation, refer to specifications. Maximum module heat dissipation is approximately equal to the ex-fiber optical power. Design a heat sink that is capable of keeping the module case temperature below the maximum rated temperature for all operating conditions. For maximum package base temperature, refer to the specification. The operation of a PPC generally does not require a heat sink, but we strongly recommend it, especially when the PPC is operated at a high input optical power level (>500 mw) Thermal Interface Materials Ideally, thermally conductive materials are used as an interface between PoF products and the heat sink to account for any flatness/smoothness discrepancies between the two parts. Suitable thermallyconductive materials include phase-change materials, greases, thermal compounds, elastomers, and adhesive films. All are designed to conform to surface irregularities, thereby eliminating air voids to improve heat flow between thermal interfaces. Use thermal grease to minimize thermal resistance. If semi-rigid thermal-interface materials (for example, phase-change material or thermal pads) are used, the thermal-interface material must cover the entire base plate including the bolt-hole area to avoid bending the base during bolt down. The specific choice and implementation of a thermal interface material depends on the customer s specific application and reliability considerations. Failure to follow proper pump module mounting procedures to a properly prepared heat sink can result in high thermal resistances and module warpage, both of which can impact performance and may lead to catastrophic failure. Fiber Handling Both the fiber buffer and external furcation cable are heat sensitive as well as being susceptible to buffer damage. Care must be taken during the setup and qualification of any process used in the handling and assembly of pump modules as the buffer is readily susceptible to damage even, for example, by coiling the fiber during product assembly and securing the coil with sections of solder or wire. This practice is commonly seen and is known to cause compression and delamination damage to the optical buffer. Maximum storage and exposure temperatures for the optical buffer are 85 C as recommended by fiber manufacturers. Exposure of the buffer to temperatures above 85 C will likely cause permanent damage to the pigtail. If temperature exposure beyond 85 C is required, it is critical to understand the risk associated to optical fiber reliability.

Technical Note: Power over Fiber 10 Follow proper fiber-handling procedures to avoid catastrophic damage in high-power lasers: Do not expose fiber to temperatures higher than 85 C Always wear finger cots or gloves when handling fiber to avoid fiber contamination Whenever possible, handle fiber in loops to prevent fiber damage Do not drag fiber over equipment Avoid a fiber contact with any sharp object Never use the fiber to pick up or support the weight of the module. Always handle modules with two hands, one holding a package and the other handling fiber coil to avoid fiber damage or breakage. Do not allow kinks or knots to develop in the fiber. Carefully work out any tangles; pulling on the fiber will cause any kinks or curls to tighten and exceed the minimum bend radius. Do not bend a fiber with a radius smaller than specified as minimum bending radius (30 mm for ) Bending the fiber to a smaller than specified minimum radius can result in an increased fiber temperature due to a bend loss and subsequent optical absorption by the fiber and its buffer. Catastrophic damage of the fiber can occur due to a crack growth induced by a temperature increase. In less severe bend situations, a temperature increase can lead to degradation of the coating and long-term reliability issues. Power Supply and Control General laser diode power supply requirements are applicable to high-power modules. Failure to follow these requirements may result in module degradation or failure. When designing or utilizing an LD power supply, designers should refer to the specified absolute maximum ratings specified for each series of high-power lasers. Electrical overstress (EOS) damage occurs when a module is subjected to voltage or current levels beyond its surge-absorbing capacity. The location and degree of damage depends on the magnitude and duration of the voltage, current, total energy, polarity, and waveform of the electrical overstress. Power supplies and test equipment can induce EOS. Recommended guidelines for preventing EOS of pump modules include: Transient electrical stress to the module should be avoided or minimized through operational life. The maximum specified transient current time for a module should never be exceeded while operating a LD; refer to the absolute maximum ratings (AMR) in the pump module specifications. Use transient suppression for power supplies Use over-voltage protection for power supplies and fuses at critical locations Confirm modules are mounted with the correct electrical pin configurations as specified Ensure that all operational and assembly equipment is properly grounded with no loose connections (which can lead to intermittent connections) north america: 800 498-JDSU (5378) worldwide: 800 5378-JDSU website: www.jdsu.com Product specifications and descriptions in this document subject to change without notice. 2014 JDS Uniphase Corporation 30175827 000 0314 POWEROVERFIBER.WP.PV.AE March 2014