Particle Surface Area

Similar documents
GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

NMR Techniques Applied to Mineral Oil, Water, and Ethanol

How To Understand The Measurement Process

Electronic Supplementary Information

Basic Principles of Magnetic Resonance

Method Development and Validation for Particle Size and Shape Measurements

Nuclear Magnetic Resonance Spectroscopy

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

4. It is possible to excite, or flip the nuclear magnetic vector from the α-state to the β-state by bridging the energy gap between the two. This is a

Nuclear Magnetic Resonance (NMR) Spectroscopy cont... Recommended Reading:

Pharmaceutical Physical Characterization: Surface Area and Porosity

Spin-Lattice Relaxation Times

Supporting Information

PHYSISORPTION DETERMINATIONS

Nuclear Magnetic Resonance

Pulsed Fourier Transform NMR The rotating frame of reference. The NMR Experiment. The Rotating Frame of Reference.

A look at the utility of pulsed NMR

Nuclear Magnetic Resonance

Nuclear Magnetic Resonance Spectroscopy

Nuclear Magnetic Resonance (NMR) Spectroscopy

The Hydrogen Atom Is a Magnet.

Atomic and Nuclear Physics

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Texture characteristic of membrane materials ASAP, BET

Nuclear Magnetic Resonance

Indiana's Academic Standards 2010 ICP Indiana's Academic Standards 2016 ICP. map) that describe the relationship acceleration, velocity and distance.

GEA Niro Pharmaceutical GMP Spray Drying facility. Spray drying process development and contract manufacturing. engineering for a better world

LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

Generation and Detection of NMR Signals

DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED

Organic Chemistry Tenth Edition

Nuclear Magnetic Resonance Logging While Drilling (NMR-LWD): From an Experiment to a Day-to-Day Service for the Oil Industry

Waves - Transverse and Longitudinal Waves

13C NMR Spectroscopy

A New Technique Provides Faster Particle Size Analysis at a Lower Cost Compared to Conventional Methods

PROTON NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY (H-NMR)

Power Injectors for Diagnostic Imaging

Bruce B. Weiner, Walther W. Tscharnuter, David Fairhurst Brookhaven Instruments Corporation Holtsville, NY US

Technically speaking, THE WHITEST WHITE

EXPERIMENTAL METHODS IN COLLOIDS AND SURFACES

The software solution to complete your flow monitoring program

BET Surface Area Analysis of Nanoparticles

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Technical Information

FINESORB Surface Area. as or more than m 2 /g. Distribution of Pore nm. Degas & Analysis Up to 12 Degas & 6 Analysis Station

Understanding SMD Power Inductors. Application Note. July 2011

Lecture #7 (2D NMR) Utility of Resonance Assignments

Continuous Granulation and Drying

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Nuclear Magnetic Resonance and the Measurement of Relaxation Times of Acetone with Gadolinium

SOCAL UP. Innovative High Performance Precipitated Calcium Carbonate for Emulsion Paints. PCC Division Solvay Special Chemicals

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

How To Use A Ds340 (Dsp)

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Pulsed Nuclear Magnetic Resonance An Experiment for UCSB s Advanced Laboratory

Development of Radiation Resistant Quadrupoles Based on High Temperature Superconductors for the Fragment Separator

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

Laser sintering of greens compacts of MoSi 2

Quick Start Guide RRL Radio Telemetry

Nano-Titanium Dioxide in Sunscreens. Gerald Renner, Colipa

Micro Motion Net Oil Computer Software and NOC System

CHAPTER 2 EXPERIMENTAL. g/mol, Sigma-Aldrich, Germany Magnesium acetate tetrahydrate (C 4 H 6 MgO. 4 4H 2 O), assay 99.0%,

Dry Grinding of Technical Ceramics into the Submicron Range

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

FileMover 1.2. Copyright Notice. Trademarks. Patents

Wireless Radio Frequency Coil for Magnetic Resonance Image of Knee Joint

Klippel Result Export to VACS AN 52

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Setting Size Specifications

= atm. 760 mm Hg. = atm. d. 767 torr = 767 mm Hg. = 1.01 atm

Tetramethylsilane (TMS) Trimethylsilyl d 4. -propionic acid (TMSP) Dioxane. O - Na + Dimethylfura n. Potassium Hydrogen Phthalate. Sodium Maleate CH 3

Enhanced Stripline Scanning Array B.M. Cahill and J.C. Batchelor

READING DEVICE US-05

Waves: Recording Sound Waves and Sound Wave Interference (Teacher s Guide)

8.9 - Flash Column Chromatography Guide

Supporting Information

Trans Fats. What is a trans fat? Trans fatty acids, or trans fats as they are known, are certain

Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection

BIOMEDICAL ULTRASOUND

Candidate Number. General Certificate of Education Advanced Level Examination June 2014

Current Probes. User Manual

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Network Administrator s Guide and Getting Started with Autodesk Ecotect Analysis

Proton Nuclear Magnetic Resonance Spectroscopy

The Basic Principles of Sieve Analysis

Impedance 50 (75 connectors via adapters)

NON-DESTRUCTIVE TESTING OF PIPELINES. L. Annila. Abstract

Simple Computer Backup

Scanning Electron Microscopy Services for Pharmaceutical Manufacturers

Congratulations! Thank you!

NMR for Physical and Biological Scientists Thomas C. Pochapsky and Susan Sondej Pochapsky Table of Contents

NOQ_NQ-9121 Z-Wave Data Logger for Gas Meters Firmware Version : 2.55

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

SMALL WONDER. THE OMNISAT MICRO. OMNIPOLAR SOUND. COMPACT DESIGN. Z E S I A L T U A C

Getting Started. MAN 0101 Issue1.3 August 1997

PicoScope 6000A/B Series

Transcription:

Particle Surface Area TM

Introducing the Acorn Area TM The Acorn Area TM is a revolutionary instrument designed to measure the surface area of nanoparticles dispersed in a liquid. This patented nuclear magnetic resonance based method offers many advantages in comparison with conventional surface area techniques. Measurements take about 5 minutes from start to finish. No sample preparation such as drying or degassing is required. High concentration dispersions are measured directly; without dilution. Acorn Area measurements are orders of magnitude faster than any other surface area measuring technique. Why Surface Area The surface area of particles influences many aspects of product performance such as the hiding power of pigments, the activity of catalysts, the taste of food, the potency of drugs and the bioavailability of drugs. In the past, surface area measurements were made using methods such as gas adsorption, mercury porosimetry, and gravimetric analysis. These methods all have the same limitation; they are only useful for analyzing dry powders. However, the overwhelming majority of manufactured products involve dispersions of particles in a liquid, either in the final state or at some stage of production. While dry powder methods are suitable to test incoming dry powder raw materials, they cannot provide information about the particles when dispersed in a liquid. To date this has not been possible other than to estimate the surface area from particle size measurements or to perform time- consuming adsorption isotherm or titration measurements. How it works Liquid in contact with the particle surface behaves differently from that of the bulk, or free liquid in response to a changing magnetic field. The NMR relaxation time of liquid on the particle surface is much shorter than that of the bulk liquid. This difference can be several orders of magnitude. The relaxation time of particles dispersed in a liquid is an average of the two relaxation times, weighted by the relative amount of liquid on the particle surface and that in the free liquid. This is a direct measure of the particle surface area. To make a measurement, place a 0.5 ml sample in a sample tube and insert it into the Acorn Area TM. The sample resides within a coil located between two permanent magnets. A static, uniform magnetic field, B 0, causes the protons within the liquid to align with B 0 ; this process typically takes a few seconds. Sample At the start of the measurement, a short radio frequency (RF) pulse excites the coil at a frequency of approximately 14 MHz. This pulse produces a large magnetic field, inducing a temporary shift in the magnetic orientation of the sample protons. When this induced field ceases, the protons of the sample fluid then realign with the static field, B 0. This realignment induces a decaying voltage in the coil, called the free induction decay (FID). By using specific pulse sequences, (combinations of RF pulses of varying length and time between pulses) the sample T1 (longitudinal) and T2 (transverse) relaxation times are measured. Although T1 and T2 are different, their shift between liquid in the bulk and liquid on the surface is similar, and both can be used to determine the surface area. Sample Tube Gradient Coils Magnet Magnet B 0 2 RF Coil 3

Exclusive Software AreaQuant TM, the Acorn Area software, measures T1 using an inversion recovery pulse sequence, and measures T2 using the CPMG pulse sequencing method. The resulting data are analyzed to determine the relative proportion of bound and free liquid and the corresponding particle surface parameters needed such as the amplitude area. and duration of the pulses, the number There are no assumptions about the of repetitions, etc. without operator sample particle size (distribution) or intervention.this ensures measurements shape used to determine surface area; are made with the highest resolution the wetted area is measured directly. The and repeatability without a great deal of user inputs the particle dispersion weight operator training. concentration, the liquid and particle To simplify method development, the density. The particle-to-liquid volume ratio software also features an automatic test (used in the calculation of surface area) is parameter file configuration based on an automatically determined. estimated T1 or T2 time input by the user. There are two Operational Modes in the Once a set of parameters are defined, software setup: Standard (or QC) Mode operation of the Acorn Area is simple: and Advanced (or R&D) Mode. The former just enter the operator name and sample is the mode used to measure surface area. information - the software does the rest! In R&D mode, the instrument behaves like a traditional NMR spectrometer capable AreaQuant TM operates on virtually all of a wide range of low-resolution NMR Windows Platforms, including XP, Vista, measurements. and Windows 7. Data files are saved in XML format, easily opened with Microsoft Measurements with the Acorn Area Excel or Open Office. Reports are saved are simple and easy. Dispersions can in RTF format. Graphs may be copied to be measured non-invasively, without the clipboard or saved in JPG or PNG dilution. The upper limit in concentration formats. To make sure you are using is essentially unlimited; the lower limit is the most up to date software available, about 1-2%. updates may be downloaded and installed Using this automatic mode, AreaQuant via the Internet with a single click of the then determines all the measuring mouse. Applications Pharmaceuticals The wetted area of the active pharmaceutical ingredient (API) available to react with stomach acids controls the rate that the product will relieve acid indigestion. Two formulations may have the same weight percentage of API but may provide a different therapeutic benefit owing to a difference in the API surface area. This relates to the concept of bioequivalence of drugs, an important issue in the debate between brand and generic pharmaceutical companies. Cosmetics Titanium dioxide is an important ingredient in many sunscreen products. UV radiation attenuation is directly related to the surface area of the TiO 2 particles. Samples having the same particle equivalent spherical diameter may have dissimilar shape and morphology, resulting in vastly different levels of UV protection. Such differences are detectable via surface area measurement of the wet suspensions. Small variations in dispersion particle aggregation are easily detected in surface area measurements. Thus, the Acorn Area can be used to monitor the quality of the dispersion. Electronics The rate at which a battery produces energy is related to the total amount of surface wetted by the reactants in the paste. Any surface not wetted will not contribute to energy generation. As energy storage becomes more and more important, the relationship between dispersion wetted surface area and product performance becomes critical. 4 5

Industry standards Support Contact us! Comparison with Surface Area using the BET Particle size measurements from different techniques do not always agree. Each technique provides a different sensitivity to the various size fractions within a particulate suspension. In addition, the various techniques use different methods to convert the raw data, i.e., diffracted light, light fluctuations, acoustic attenuation, etc., into a particle size. A similar situation exists when comparing surface area measured using the Acorn Area and gas adsorption (BET). The Acorn Area measures the total wetted surface area of the particles in a liquid, while the BET technique measures the amount of gas adsorbed on the surface of dry particles. If the wetted area and the area available for gas adsorption are the same, then the two techniques should produce the same number. In practice, however, differences in sample preparation between wet and dry states may yield samples in which the wetted area and the dry area are dissimilar, resulting in disparate values for the measured surface area. Validation of the Acorn Area Technique Klebesol 30HB 25K (Rohm & Haas) is a nanoparticulate silica slurry used in electronics as a polishing compound for silicon wafers. These silica particles are spherical; the dispersion is highly monodisperse and is delivered as a 30% by weight slurry. The surface area of these particles reported by the manufacturer (measured by an unspecified titration method) was 120m 2 /g. Estimation of the surface area based on a particle diameter determined from dynamic light scattering was 123 m 2 /g. Direct measurement by the Acorn Area, on the 30% by weight slurry, yielded 121 m 2 /g. Measurements with the Acorn Area on this concentrated dispersion took less than 5 minutes. In contrast, gas adsorption would have required separation of the particles from the liquid by drying, then degassing the surface - a process that can take several hours. Such sample preparation can cause particle aggregation, leading to an inaccurate determination of surface area. The titration method is nonroutine, requires sensitive instrumentation and skilled operators. Calculation from particle size is only possible because the material is spherical and monodisperse. Measurement by dynamic light scattering also requires substantial dilution of the dispersion. This is not always a straightforward exercise and can lead to particle aggregation. The Acorn Area has no moving parts and is designed using state-of-the-art microprocessor technology; system failures are highly unlikely. However, should it be necessary to service your unit we will Priority ship overnight any replacement parts to keep down-time to an absolute minimum. All parts are user replaceable. Our service technicians can operate the Acorn Area remotely through a web session, allowing us to diagnose the problem, and in some cases, fix the problem remotely. The Acorn Area Advantage: Low cost Measurements without dilution No sample preparation Results in minutes Compact No moving parts Suitable for QC or R&D Simple to use Specifications: Interface: PC or PDA via USB Power: 100-240 VAC 50/60 Hz, 3 amps L x W x H: 240 x 360 x 160 mm Wt.: 7 kg Is the Acorn Area suitable for your application? Call to discuss it with our technical staff. Send us a sample.we will be happy to make a measurement. If you would like a demonstration, we can arrange to visit your facility or demonstrate the Acorn Area via the Internet. See for yourself the incredible cost-performance benefits that the Acorn Area provides. For more information, please contact: XiGo Nanotools Corporate Office 116 Research Drive Bethlehem, PA 18015 Tel: (610) 849-5090 Fax: (610) 465-8631 sales@xigonanotools.com www.xigonanotools.com XiGo Nanotools Sales & Service Europe 8 Hoveton Gardens St Helens, WA9 5UR, UK ksanderson@xigonanotools.com Tel: +44(0)151 324 276 Acorn and AreAQuant are trademarks of XiGo Nanotools. The product information in this document was correct at the time of printing, but may change, as part of continuous product innovation, without notification. 6 7

TM XiGo Nanotools Corporate Office 116 Research Drive, Bethlehem, PA 18015