What is QuickBase? Traditional foundations (left) compared with QuickBase (right)



Similar documents
STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

ENGINEERED FOUNDATIONS. Department of Public Works Jeff Hill, PE

Designed and Engineered to Perform

The minimum reinforcement for the stem wall is the placement of:

Hanson Building Products. precast basement solutions

BUTE Department of Construction Management and Technology

HOUSE BUILDING DIGEST

Analysis II Façade Redesign: Architectural Precast Panels

Confort 160. Sliding Systems. Sapa Building System

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

Guide to working on Public Sewers

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.

TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR

Lighthouse Engineering, L.L.C.

WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

New construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

Manual lifting and handling

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

12.1 Schlüter -KERDI-BOARD

Module 3.7. Thermal bridging

EAST LYME HIGH SCHOOL

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

How to build a Pizza Oven in 4 days

Rockwool Flexi Insulation Application Guide

The Stabilizer TM. Benefits. Supplemental support system for sagging beams and floor joists within a crawl space

GOOD NEWS BUT NOT ALWAYS

Dubai Municipality Standard DMS 1: Part 5: 2004

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

The answer. Cost-Benefit Ratio of different construction depths. Comparison of U f -values. profine GmbH Kömmerling Kunststoffe

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

A few inches will give your business room to grow...

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Sports Buildings: budget costs for the Flood Relief Fund

Soils, Foundations & Moisture Control

Structural Foundation System

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

LAYING BLOCK AND BRICK

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

INDEX DESCRIPTION MATERIALS APPROVAL OF SUBBASE COURSE CONSTRUCTION MEASUREMENT PAYMENT 6

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Supplier ID: Local Office: GLASGOW 69 Buchanan Street Glasgow G1 3HL

FOUNDATION TECHNICAL CATEGORY 3 (TC3) AUGUST 2012

Renovating Your Basement

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

Raised beds page. What are the benefits of raised beds? What are the difficulties with raised beds?

SECTION 1 GENERAL REQUIREMENTS

Siting and settlement: The most important way to protect shelter from floods is to build in a place that is unlikely to be flooded.

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Plaisance 24. Sliding Systems. Sapa Building System

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

Transmission Foundations Case History : Helical piles Hydro One Networks Inc.

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Step 11 Static Load Testing

Confort 26. Sliding Systems. Sapa Building System

Installation Window Building In Details

Foundation Repair Fundamentals And how they relate to the Real Estate Industry in the DFW Area

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

How to build raised beds page

Pro-Lift Steel Pile Foundation Repair

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

TECHNICAL MANUAL. New Homes

POST FOUNDATION REPAIR PERFORMANCE RESIDENTIAL AND OTHER LOW-RISE BUILDINGS ON EXPANSIVE SOILS. The Repair Committee of

Mark Cramer Inspection Services, Inc.

Removable Aluminium posts

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

APPENDIX B. I. Background Information

The WANZ Guide to Window Installation

6 RETROFITTING POST & PIER HOUSES

symptoms of a faulty foundation

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION

Response, Reliability and Results in the delivery of leak detection services

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Residential Inspection Guidelines

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

Building over or close to a public sewer

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

DELTA Premium Moisture Management Systems for Foundations.

System. Stability. Security. Integrity. 150 Helical Anchor

Cold Weather Concrete Practices

What you need to know about concrete block basement construction.

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

HEDDERMAN ENGINEERING, INC. Office , Fax

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

Transcription:

QuickBase is an innovative new foundation and floor system for conservatories and lightweight structures which was launched in prototype form at last year s Interbuild exhibition, where it was hailed as the Best New Exterior Product. An unrivalled modular system, QuickBase was developed and pioneered by Shire Structures and the Wykamol group of companies, and promises the highest quality construction with significant environmental and technical benefits, as well as offering major time and cost savings when compared with traditional methods. What is QuickBase? The heart of the QuickBase system is Shire s helical screw piles, which are driven into the ground to suitable load bearing strata, removing the need for mass concrete foundations. The piles are generally driven to a minimum depth of 4 metres (deeper if required) to accommodate loose surface soils and troublesome tree roots. Traditional foundations (left) compared with QuickBase (right)

The piles support lightweight, part-recycled plastic ground beams connected via a series of push-fit joints to form a frame. The ground beam is then filled with a specially formulated non-shrink grout to give a high strength composite beam. A pre-manufactured lightweight insulated damp proof floor slab is fixed with resin onto the completed ground beams. QuickBase - changing the face of the conservatory industry In 2006 the conservatory market was worth 1billion for basic build; when fixtures and fittings are included, the figure rises to 2billion. Conservatory foundations have historically suffered a high failure rate, leading to calls for greater regulation. The introduction of modular construction methods would favour this potential change. Increasing labour costs and the trend for more environmentally-friendly forms of building also making the QuickBase system an attractive option for builders and homeowners alike.

The benefits QuickBase offers a number of overwhelming benefits when compared to traditional foundations. a) Cost QuickBase delivers overall cost benefits against traditional building methods. It does not require wet trade finishing, lowering overall labour costs. b) Time In most instances QuickBase foundations can be started and finished in less than one day, against up to a week digging out deep foundations. c) Environmental QuickBase is a more environmentally friendly method of construction. The beams are made partly from recycled materials and the damp proof floor slab is insulated, making it more economical once built. It is virtually a dry build process, reducing the volume of water used. Less natural aggregates are used and there is generally no excavated material to take to landfill sites. All components are delivered from a single source, reducing the volume of construction traffic. d) Access and flexibility QuickBase is ideal for houses with limited or no outside access to the site. Modular parts can be carried safely and cleanly through the house, and no heavy digging equipment is required. The adjustable pile depth guarantees that the structure will sit on suitable load-bearing strata and can support structures which would otherwise be unbuildable. The pile is generally driven to a depth of 4 metres to accommodate loose ground and tree roots, but it can be driven deeper if required. The patented helical fin arrangement allows the pile to work in both granular and cohesive soils.

e) Quality The QuickBase system uses the best materials and the highest quality construction to guarantee a reliable, safe product. Offsite, modular construction means quality and the tightest tolerances can be assured. The ground beams and floor are corrosion resistant, and QuickBase-approved installers can provide a full installation warranty. f) Strength The plastic beam is designed to carry loads up to a single storey building and higher loads can be carried by increasing the reinforcement in the ground beam or by reducing the pile centres. The beam is filled with a high strength grout which increases its strength and prevents any excessive thermal movement. The research and development process Shire Stabilizers were developed by Shire Structures for its work for the remedial insurance market. The potential for smaller piles to be used in lightweight new build construction became obvious and Shire piles - the supports for QuickBase - were born. Difficult access often makes the construction of traditional foundations to the rear of a property difficult. A prefabricated lightweight foundation system would eliminate these problems and development of the Quickbase system started 3 years ago. The early prototypes were launched at Interbuild 2007 and, since then, a programme of field test and laboratory testing has been underway. Both floor slabs (insulation sandwiched between two layers of fibreglass) and ground beam (grout filled plastic) are composite sections and required extensive testing and design. Testing ground beam to failure at Coventry University Long term testing of floor panel

Technical information Piles The pile is in three sections: base, stem and head. The base comprises a steel rod with helical steel fins which trap the soil and increase capacity The stem tubes have a baked on slip coating and are used to transfer the load from the head of the pile to the base. A unique pile head has been produced to give both vertical and angular adjustment. Ground beam The standard ground beam comprises a rectangular section with a leg to support the outer skin of brickwork. Sections without legs are available for internal beams. Preformed corners, T junctions and straight couplers are available. The corners can be set to any angle allowing complex plan shapes to be supported. Floor Panels Standard floor panels are 1.2m wide and up to 4m long. K value of insulation is 0.025 wmc for the standard 100mm thick floor, giving a U value of 0.25W/m2. The insulation is of a closed cell construction and therefore resistant to all moisture. Additional insulation can be provided if required. Two fibreglass skins give a lightweight composite construction with high load carrying capacities.

The customer s reaction QuickBase has been used for the foundations to conservatories, building extensions, garden rooms and Eco-extensions. Conservatories Garden Rooms Building Extensions Andrew Roff from Cheltenham chose QuickBase when adding a kitchen extension on to his property. The extension was planned to be built on clay, within close proximity to trees and with no direct road access, and Andrew had already come to the conclusion that piles were more suitable to the project than solid concrete-filled trenches. He was recommended to choose QuickBase over traditional piles for the 16m 2 extension. Ten piles in total were installed to a depth of 4.7m and the whole process, including installing the floor panels, took just one day. My builder thought it was wonderful, said Andrew. A completely level, set-out base on which they could immediately start their blockwork. The building inspector visited on the day of installation and seemed impressed with the speed of progress. She raised no queries on the design or materials used. At the end of the day there was no mess and no rutted ground. Photographs of the installation are shown on the following page.

Quickbase foundation systems are distributed in the UK by the Wykamol Group Unit 3, Boran Court, Network 65 Business Park, Hapton, Burnley, Lancashire, BB11 5TH Tel: +44 (0)845 644 0000 Fax: +(0)845 400 3333 Email: info@quickbaseuk.com Web: www.quickbaseuk.com