CFX96 Real-Time PCR Detection System. Real-Time PCR: CFX96 System



Similar documents
amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

Image Lab Software for the GS-900 Densitometer

Image Lab Software How to Obtain Stain-Free Gel and Blot Images. Instructions

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

Computer Specifications

Introduction To Real Time Quantitative PCR (qpcr)

LightCycler 480 Real-Time PCR System

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

Essentials of Real Time PCR. About Sequence Detection Chemistries

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Real-Time PCR Vs. Traditional PCR

Fast PCR: General Considerations for Minimizing Run Times and Maximizing Throughput

Amplification: Thermal Cyclers. Bio-Rad Thermal Cyclers

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

A guide to the analysis of KASP genotyping data using cluster plots

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

QIAsymphony RGQ Protocol Sheet

TaqMan Fast Advanced Master Mix. Protocol

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Eco TM 48 Real Time PCR System. Fastest block-based qpcr. Four colour multiplexing. Supports all chemistries. Fast cycling protocols

Release Notes: PowerChute plus for Windows 95 and Windows 98

Highly specific and sensitive quantitation

Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

Quantitative PCR Systems

Real-time qpcr Assay Design Software

Configuring DHCP for ShoreTel IP Phones

PrimeSTAR HS DNA Polymerase

Lawson Business Intelligence. Solutions for Healthcare

ProteinChip Energy Absorbing Molecules (EAM)

PicoMaxx High Fidelity PCR System

High-Speed Inter Connect (HSIC) Solution

Speed Matters - Fast ways from template to result

Real-time PCR: Understanding C t

Quantum View Manage Administration Guide

SYBR Green Realtime PCR Master Mix -Plus-

Transforming a ChromLab Software 2-D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide

Expression Proteomics // Tools for Protein Separation and Analysis. 2-D Electrophoresis. Tools for Rapid, High-Resolution Protein Separations

Plexor Systems Instrument Setup and Data Analysis for the Applied Biosystems 7300 and 7500 Real-Time PCR Systems

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Absolute Quantification Getting Started Guide

Validating Microarray Data Using RT 2 Real-Time PCR Products

SeqScape Software Version 2.5 Comprehensive Analysis Solution for Resequencing Applications

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

QuantStudio 12K Flex Real-Time PCR System. The all-in-one qpcr instrument

Factors Influencing Multiplex Real-Time PCR

Quando si parla di PCR quantitativa si intende:

ab Hi-Fi cdna Synthesis Kit

Schedule R Teleconferencing Service

Accelerated Electrophoresis with Faster Run Times and Increased Sample Throughput

2.500 Threshold e Threshold. Exponential phase. Cycle Number

DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments

Accuracy counts! SENSORS WITH ANALOG OUTPUT

BT Premium Event Call and Web Rate Card

Stratagene QPCR Mouse Reference Total RNA

Reporting practices for domestic and total debt securities

Building Technologies

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

Cell Sorting. S3e Cell Sorter Quick Guide

Plexor Systems Instrument Setup and Data Analysis for the Roche LightCycler 2.0 and LightCycler 1.5 Systems using LightCycler Software Version 4.

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Protocol. Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR

Amplification/PCR. Amplification Software 303

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

NI USB-6008/6009 OEM USER GUIDE

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Application Guide... 2

[NUGENESIS SAMPLE MANAGEMENT ] AMPLE IMPROVING LAB EFFICIENCY, ANAGEMENT ACCELERATING BUSINESS DECISIONS. bigstock.com $69

Fluorescent dyes for use with the

World Consumer Income and Expenditure Patterns

Cisco Conference Connection

C1000 Touch Thermal Cycler Instruction Manual

Cisco Blended Agent: Bringing Call Blending Capability to Your Enterprise

1.5 GHz Active Probe TAP1500 Datasheet

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Mir-X mirna First-Strand Synthesis Kit User Manual

Bio-Plex Analysis Software

Microsoft Dynamics CRM Online. Pricing & Licensing. Frequently Asked Questions

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

360 Master Mix. , and a supplementary 360 GC Enhancer.

PowerPac Universal and PowerPac HV Power Supply Data Transfer Software. Instruction Manual

Get the benefits of Norgren s unique range of Online services

Lawson Talent Management

Microsoft Dynamics CRM Online. Pricing & Licensing. Frequently Asked Questions

Guide to using the Bio Rad CFX96 Real Time PCR Machine

RealLine HCV PCR Qualitative - Uni-Format

IOOF QuantPlus. International Equities Portfolio NZD. Quarterly update

Bio-Plex Manager 6.1 Software Upgrade and Configuration Guide

Report on Government Information Requests

CISCO NETWORK CONNECTIVITY CENTER

Supplemental Material. Methods

CISCO MDS 9000 FAMILY PERFORMANCE MANAGEMENT

LAWSON FOR FASHION PRODUCT LIFECYCLE MANAGEMENT (PLM)

Appendix 1: Full Country Rankings

Agilent OSS Wireless QoS Manager

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

PRODUCT DATA. PULSE WorkFlow Manager Type 7756

Path-ID Multiplex One-Step RT-PCR Kit

Transcription:

Real-Time R Detection System Real-Time R: System

Life Science Group Bio-Rad Laboratories, Inc. Web site www.bio-rad.com USA 800 4BIORAD Australia 61 02 9914 2800 Austria 01 877 89 01 Belgium 09 385 55 11 Brazil 55 21 3237 9400 Canada 905 364 3435 China 86 21 6426 0808 Czech Republic 420 241 430 532 Denmark 44 52 00 Finland 09 804 22 00 France 01 47 95 69 65 Germany 089 318 84 0 Greece 30 2 777 4396 Hong Kong 852 2789 3300 Hungary 36 1 455 8800 India 91 124 4029300 Israel 03 963 6050 Italy 39 02 216091 Japan 03 6361 7000 Korea 82 2 3473 4460 Mexico 52 555 488 7670 The Netherlands 0318 540666 New Zealand 0508 805 500 Norway 23 38 41 30 Poland 48 22 331 99 99 Portugal 351 21 472 7700 Russia 7 495 721 14 04 Singapore 65 6415 3188 South Africa 27 861 246 723 Spain 34 91 590 5200 Sweden 08 555 12700 Switzerland 061 717 95 55 Taiwan 886 2 2578 7189 United Kingdom 020 8328 2000 014812 Rev A US/EG 08-0723 08 Sig 0308 Windows and Windows Vista are trademarks of Microsoft Corporation. For use with authorized real-time instrument or thermal cycler for applications other than human in vitro diagnostics. Please see instrument instruction manual for complete licensing statement. Installation Quick Guide Amplification: Real-Time R Amplification Precision Melt Analysis Software 014812 Rev A 2008 Bio-Rad Laboratories, Inc. Version 1.0 All rights reserved. The System Designed for the Way You Work Bio-Rad s 00-series R instruments meet all your R needs whether you are designing your first experiment or running a high-throughput laboratory and analyzing large gene expression studies. The real-time R detection system builds on the power and flexibility of the C00 thermal cycler, adding an easy-to-install interchangeable reaction module to create an exceptional real-time R system. The system s unsurpassed thermal performance plus its innovative optical design produce accurate, reliable data, and the powerful, yet intuitive software accelerates every step of your real-time R research, shortening the time between getting started and getting great results. With the system, you can: n Get great results right away quick installation and factory-calibrated optics let you set up the system in seconds n Fit experiments into your schedule fast thermal cycling produces results in <30 minutes n Save research time thermal gradient feature lets you optimize reactions in a single experiment n Minimize sample and reagent usage optimal results obtained with sample volumes as low as µl n Rely on performance innovative technologies with long-lasting LEDs and solid-state components provide maximal reliability and optimal quantitative results n Analyze results when and where you want software can send email notification with an attached data file when a run is finished n Configure the system to fit your laboratory needs run a stand-alone system without a computer or up to 4 instruments from 1 computer Bio-Rad s R instruments, reagents, plastics, and software are powerful building blocks for your genomic research, providing the flexibility and reliability you need to accelerate discovery. or Windows Vista operating system is required to run the software. Minimum computer specifications are listed in the Precision Melt Analysis Software Instruction Manual. The software must be installed on the computer by a user with administrative privileges. Installing the Precision Melt Analysis Software A computer with either the Windows XP automatically, click on CD drive, then open and follow the instructions in the Readme.txt file. software CD in the computer s CD drive. The software launch page should appear automatically. 2. Click Next on the software launch page. 3. Follow the instructions onscreen to complete the installation. 4. If the launch page does not appear To install the Precision Melt Analysis software:e: 1. Place the Precision Melt Analysis Reagents That Provide Optimal Performance Bio-Rad reagents demonstrate best-of-class performance over a wide dynamic range of input RNA, cdna, and genomic DNA. The broad mix of reverse transcription kits and supermixes for qr delivers maximum sensitivity and consistent results every time. Don t Worry About Your Consumables Bio-Rad s plastic consumables have been validated to deliver reliable, reproducible results, leaving you less to worry about. Precision Melt Analysis Software Version 1.0 Precision Melt Analysis Software Version 1.0 Software Solutions Bio-Rad offers a complete line of software products to accelerate your research. Precision Melt Analysis software is a powerful tool to genotype DNA samples based on the thermal denaturation properties of double-stranded DNA. Biogazelle s qbase PLUS software makes higher throughput gene expression analysis accessible to every researcher. Identify the role of target genes in specific cellular processes or signaling pathways using a combination of tools from Bio-Rad.

System Configurations Stand-alone or CFX384 C00 Stand-alone multi-instrument C00 or CFX384 C00 C00 Software-controlled C00 or CFX384 C00 or CFX384 C00 Software-controlled multi-instrument C00 C00 or CFX384 or CFX384C00 C00 or CFX384C00 or CFX384 C00 C00 CFX Automation System C00 The real-time R detection system offers multiple control configurations so it can be easily integrated into your laboratory settings. The system can be quickly installed, fitting on any lab bench. Its factory-calibrated optics let you get great results right away and its quiet operation will not add to laboratory noise. Stand-Alone Perform real-time R runs on a system in stand-alone mode, without the system being attached to a computer. Create a real-time R protocol using the C00 control panel, or transfer a protocol previously created in CFX Manager software using a flash drive. Choose a data acquisition mode and start an experiment there is no need to worry about the plate setup because data are acquired from all the wells. When a run is finished, export the data using a flash drive, or directly email the data from the C00 chassis. Data are stored on the instrument during a run, regardless of the setup, so you always have built-in data backup. Expanding Your Throughput The flexibility of the 00-series thermal cycling platform allows you to adjust your setup as your needs change. Adding more instruments to increase throughput or expand options is as easy as connecting a cable. CFX Manager software can independently run four instruments, including a combination of and CFX384 real-time R detection systems and C00 or thermal cyclers. Maximize laboratory throughput by integrating one system with a CFX automation system for hands-free loading and unloading of up to 20 96-well plates. Integrated for Optimal Results Reliable and reproducible real-time R assays require an instrument with validated optical performance. The system has unique features which ensure precise assay results, so that you can confidently make comparisons between data sets: n Internal qualification before every scan to ensure the optics shuttle is homed with micron accuracy n Internal reference spots, which the system reads to measure the consistency and accuracy of every scan n System test software to qualify instrument performance

Fast Thermal Cycling Superior Uniformity The rate and efficiency of R critically depend on the precision of the temperature steps. To obtain reliable, consistent results, all sample wells must maintain proper temperature throughout each incubation step. The system uses six independently controlled thermal electric modules (TEs), the heating and cooling elements of the thermal cycler, to maintain tight temperature uniformity at all points during a run even while ramping. Rapid Arrival at Target Temperature A key component of overall protocol run time is the time to reach target temperature, which is determined by the average ramp rate and the time for the sample block to reach thermal uniformity. Maximum ramp rate is less important, because it can fluctuate significantly during the ramp. The system s temperature control produces high average ramp rates and tight uniformity during ramping, to yield fast time to target temperature and faster protocol run times. Run times can be dramatically shortened to less than 30 minutes while still producing accurate quantitative results. Now you can tailor your runs around your schedule, instead of tailoring your schedule around your runs. 90 85 Temperature, C 80 75 70 65 60 The patent-pending reduced-mass sample block heats and cools more quickly than standard blocks, so average ramp rates are increased and overall run times are reduced. 55 0 20 40 60 80 0 120 140 160 180 200 Time, sec Rapid arrival at target temperature and superior uniformity. 00-series thermal cyclers exhibit high average ramp rates, rapid settling time, and tight thermal uniformity throughout the ramp. This graph shows the temperature measured by probes in 15 wells across a sample block. The traces are nearly indistinguishable due to the tight uniformity. Note the consistent ramp rate throughout heating and cooling. 0 0 30 40 Excellent uniformity. IL-1b plasmid template diluted to 5 copies/reaction amplified in the presence of a FAM-labeled detection probe with iq supermix. Graph shows 96 replicates of μl reactions. Average threshold cycle (C T ) = 19.81 ± 0.., relative fluorescence units. 0 0 30 40 Exceptional reproducibility can be achieved with SsoFast EvaGreen supermix. Efficient discrimination and reliable quantification can be obtained from 1.33-fold serial dilutions of input template. The CBP gene was amplified from varying amounts of human genomic DNA (5 ng to 500 pg). From left to right: (n) 5 ng, 2.83 ng, 1.60 ng, 903 pg, and 511 pg; (n) 3.76 ng, 2.13 ng, 1.20 ng, and 679 pg. CBP efficiency = 96.5%, r = 0.996. Insert is a magnified view showing robust discrimination and reproducible amplification., relative fluorescence units. 0 0 30 40 The unique fusion polymerase in SsoFast EvaGreen supermix delivers extreme speed and generates exceptional qr results in less than 30 min. Tenfold serial dilutions of ng to 0 ag of cdna from human spleen were used in each 20 μl reaction to detect 18S rrna. 18S efficiency = 1.8%, r = 0.997. Total qr run time = 29 min., relative fluorescence units.

Innovative Optical Design The system s solid-state optical technology provides sensitive detection for precise quantitation and target discrimination. Scanning just above the sample plate, the optics shuttle individually illuminates and detects fluorescence from each well with high sensitivity and no cross talk. The optical system automatically collects data from all wells during data acquisition, so you can enter or edit well information on your own schedule. True Five-Target Multiplexing The system can discriminate up to five targets in a single reaction well. The optical filter sets are designed to maximize fluorescence detection for specific dyes in specific channels. At every position and with every scan the optics shuttle is reproducibly centered above each well, so the light path is always fixed and optimal and there is no need to sacrifice data collection in one of the channels to normalize to a passive reference. Multiple Data Acquisition Modes The system can acquire data using several modes. Choose to acquire data for SYBR Green I and single-color FAM protocols using the fast scan mode, or choose to acquire data from all channels when performing multiplex protocols. The system s optics shuttle includes one channel with an LED-filter photodiode combination designated for single-color fluorescence resonance energy transfer (FRET) experiments, further expanding your experimental options. Excitation Channel 1 450 490 Reporter dye: FAM 1.00 Normalized absorbance Detection Channel 1 5 530 Reporter dye: FAM 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0. Normalized intensity Channel 2 515 535 HEX Channel 3 560 590 Texas Red 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0. 0.00 425 450 500 550 600 650 700 750 775 Wavelength, nm Channel 2 560 580 HEX Channel 4 Channel 5 620 650 672 684 Cy5 Quasar 705 Channel 3 6 650 Texas Red Channel 4 675 690 Cy5 Channel 5 705 730 Quasar 705 0.00 425 450 500 550 600 650 700 750 775 Wavelength, nm Excitation and detection wavelength ranges for the system. A 0 0 30 40 C B 0 0 30 40 D 4 0 0 30 40 0 0 30 40 As the optics shuttle travels across the plate, light is focused directly into the center of each sample well. Side view of the optics shuttle shows the green LED firing over a well. E F 4 35 30 25 20 15 0 0 30 40 2 3 4 5 6 7 8 log starting quantity Linearity of five-target multiplex detection. A E, fluorescence data from a series of -fold dilutions of plasmid DNA ( 8 copies) amplified using reporter dyes to monitor five targets: n, FAM/actin; n, HEX/GAPDH; n, Texas Red/cyclophilin; n, Cy5/tubulin; n, Quasar 705/IL-1b; F, standard curves generated from data in A E, reaction efficiencies range from 97 to 3%. C T, threshold cycle;, relative fluorescence units. C T

Powerful Software CFX Manager software is powerful software for a powerful instrument. It accommodates user needs and different types of experiments with intuitive navigation and customizable settings. Getting Started CFX Manager software s convenient wizards and intuitive navigation make it easy to get started and to get great real-time R results. Get an experiment started with the Quick Plate feature, then enter or edit well information on your own schedule before, during, or after a run has finished. Getting Answers CFX Manager software can send email notification with an attached data file when a run is finished, so you can analyze your results when and where you want. The software has built-in data analysis modules and you can easily customize how your data are analyzed and displayed. A well-grouping feature is available to analyze multiple experiments from a single plate. Perform gene expression analysis by relative quantity ( C T ) or normalized expression ( C T ) using multiple reference genes and individual reaction efficiencies. If you are performing a comprehensive study with multiple experiments, you can use CFX Manager software to combine and analyze all data at once. Precision Melt Analysis Software Precision Melt Analysis software is a convenient, easy-to-use application that imports and analyzes data files generated from the or CFX384 real-time R detection system to genotype samples based on the thermal denaturation properties of doublestranded DNA. The software can be used for a variety of genotyping applications, including scanning for new gene variants, screening DNA samples for SNPs, identifying insertions/deletions or other unknown mutations, and determining the percentage of methylated DNA in unknown samples. Precision Melt Analysis software saves analysis time by assigning sample genotypes automatically based on cluster analysis, or manually using multiple data view options to tailor the software to the appropriate analysis. Difference curve plots of a sample fluorescence versus a selected control at each temperature transition provide a convenient visual aid to interpret the data. Precision Melt Analysis software enables data comparison between multiple file runs by combining data into a single Melt Study. Develop a standard library of melt curve runs to analyze an unlimited number of melt experiments without having to export data. 1.0 Normalized 0.8 0.6 0.4 0.2 Heterozygote Mutant Wild type CFX Manager software data analysis module, showing well C6 highlighted. 0.0 73 74 75 76 77 78 Temperature, C SNP genotyping by Precision Melt Analysis software using data generated by the real-time R detection system. Discrimination of human factor V coagulation SNP genotypes (C to T substitution) using SsoFast EvaGreen supermix. Data from homozygous wild type (n), mutant (n), and heterozygote (n) samples are shown on a normalized melt curve plot., relative fluorescence units.

Efficient Optimization Thermal Gradient Determining the optimal temperature for primer annealing is crucial for efficient and specific amplification of product. With the system s thermal gradient feature, you can determine the optimal temperature for primer annealing in a single experiment, minimizing the use of precious samples and reagents and saving valuable research time. At any step in a protocol, you can program a temperature gradient of up to 24 C across the reaction block. The thermal cycler provides exceptional temperature uniformity and reproducibility within each gradient zone, and the temperatures can easily be programmed and viewed onscreen in the software, so you can quickly identify the optimal incubation temperature. qbase PLUS Software qbase PLUS software is a powerful tool that imports and analyzes data generated from the or CFX384 real-time R detection system. This platformindependent software package is available for major computer operating systems, such as Microsoft Windows, Macintosh, and Linux. qbase PLUS accelerates real-time R data analysis and provides independent validation of gene expression results using proven, qualified algorithms. Key benefits of qbase PLUS software include: n Reliable validation based on proven solutions for quality control, normalization, and inter-run calibration n Easy-to-use program intuitive navigation with automated calculations and error propagation n Efficient analysis fast calculations of results with direct import of instrument data; use the integrated data organizer to streamline managing results n Flexible programming intuitive to use for small experiments; powerful for big experiments 67 C 62 C 56 C 0 0 30 40 0 0 30 40 15 0 0 30 40 1 2 3 4 5 6 log starting quantity Thermal gradient experiment for optimizing annealing temperature. A -fold dilution series ( 6 to copies) of plasmid containing GAPDH template was amplified in the presence of SYBR Green dye using a protocol with an annealing thermal gradient ranging from 55 to 68 C. Results are presented for three temperatures, showing 62 C as the optimal in this case, with early C T values and the highest standard curve efficiency. C T, threshold cycle;, relative fluorescence units. C T C T C T Data analysis window in qbase PLUS software. 40 SYBR Green: E = 68.3% 35 30 25 20 1 2 3 4 5 6 30 25 20 15 30 25 20 SYBR Green: E = 98.7% 1 2 3 4 5 6 SYBR Green: E = 93.6%

Specifications Thermal Cycler Chassis C00 Maximum ramp rate 5 C/sec Average ramp rate 3.3 C/sec Heating and cooling method Peltier Lid Heats up to 5 C Temperature Range 0 0 C Accuracy ±0.2 C of programmed target at 90 C Uniformity ±0.4 C well-to-well within sec of arrival at 90 C Gradient Operational range 30 0 C Programmable span 1 24 C Optical Detection Excitation 6 filtered LEDs Detection 6 filtered photodiodes Range of excitation/emission 450 730 nm wavelengths Sensitivity Detects 1 copy of target sequence in human genomic DNA Dynamic range orders of magnitude Scan time All channels 12 sec FAM/SYBR Green only 3 sec CFX Manager Software Operating systems Windows XP, Windows Vista Memory Minimum 1 GB Multiplex analysis Up to 5 targets per well Data analysis modes R quantitation with standard curve Melt curve analysis Gene expression analysis by relative quantity ( C T ) or normalized expression ( C T ) with multiple reference genes and individual reaction efficiencies Multiple file gene expression analysis for comparison of an unlimited number of C T values Allelic discrimination End-point analysis Data export Save, copy, and print all graphs and spreadsheets from right-click menu Export results to Microsoft Excel Copy and paste directly into Microsoft Excel, Word, or PowerPoint files Customizable reports containing run settings, data graphs, and spreadsheets can be directly printed or saved as PDFs System Licensed for real-time R Yes Sample capacity 96 wells Sample size 1 50 µl ( 25 µl recommended) Communications 2.0 Electrical approvals IEC, CE Dimensions (W x D x H) 33 x 46 x 36 cm (13 x 18 x 14") Weight 21 kg (47 lb) Ordering Information Catalog # Description 184-00 C00 Thermal Cycler Chassis, includes key, power cord; does not include reaction module 184-5096 Optical Reaction Module, for use with C00 thermal cycler chassis, includes CFX Manager software, license for qbase PLUS software, communication cable, reagents, consumables 185-5096 Real-Time R Detection System, includes C00 thermal cycler chassis, optical reaction module, CFX Manager software, license for qbase PLUS software, communication cable, reagents, consumables 184-5001 CFX Manager Software, Security Edition, includes 1 user license, installation CD, HASP HL key 184-5025 Precision Melt Analysis Software, includes 2 user licenses, installation CD, 2 HASP HL keys, melt calibration kit 184-5008 CFX Manager Software, Chinese Edition, includes 3 user licenses, installation CD, 3 HASP HL keys 184-5028 CFX Manager Software, Russian Edition, includes 3 user licenses, installation CD, 3 HASP HL keys 184-5072 CFX Automation System, includes robotic plate handler, base tray, bar code scanner, CFX automation control software CD 172-5200 SsoFast EvaGreen Supermix, 200 x 20 μl reactions, 2x mix contains dntps, Sso7d fusion polymerase, MgCl 2, EvaGreen dye, stabilizers 170-8890 iscript cdna Synthesis Kit, 25 x 20 µl reactions, includes 5x iscript reaction mix, iscript reverse transcriptase, nuclease-free water 172-5848 iq Multiplex Powermix, 50 x 50 µl reactions, 2x mix contains dntps, 11 mm MgCl 2, itaq DNA polymerase, stabilizers Cy is a trademark of GE Healthcare group companies. EvaGreen is a trademark of Biotium, Inc. Bio-Rad Laboratories, Inc. is licensed by Biotium, Inc. to sell reagents containing EvaGreen dye for use in real-time R, for research purposes only. Excel, Microsoft, PowerPoint, Windows, and Windows Vista are trademarks of Microsoft Corporation. Linux is a trademark of Linus Torvalds. Macintosh is a trademark of Apple Inc. Quasar is a trademark of Biosearch Technologies, Inc. SYBR is a trademark of Molecular Probes, Inc. Texas Red is a trademark of Invitrogen Corporation. Practice of the patented 5' Nuclease Process requires a license from Applied Biosystems. The purchase of these products includes an immunity from suit under patents specified in the product insert to use only the amount purchased for the purchaser s own internal research when used with the separate purchase of Licensed Probe. No other patent rights are conveyed expressly, by implication, or by estoppel. Further information on purchasing licenses may be obtained from the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA. Purchase of this instrument conveys a limited non-transferable immunity from suit for the purchaser s own internal research and development and for use in human in vitro diagnostics and all other applied fields under one or more of U.S. Patent Numbers 5,656,493; 5,333,675; 5,475,6 (Claims 1, 44, 158, 160 163, and 167 only); and 6,703,236 (Claims 1 7 only), or corresponding claims in their non-u.s. counterparts, owned by Applera Corporation. No right is conveyed expressly, by implication or by estoppel under any other patent claim, such as claims to apparatus, reagents, kits, or methods such as 5 nuclease methods. Further information on purchasing licenses may be obtained by contacting the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA. Bio-Rad s real-time thermal cyclers are licensed real-time thermal cyclers under Applera s United States Patent Number 6,814,934 B1 for use in research, human in vitro diagnostics, and all other fields except veterinary diagnostics. Bio-Rad s thermal cyclers and real-time thermal cyclers are covered by one or more of the following U.S. patents or their foreign counterparts owned by Eppendorf AG: U.S. Patent Numbers 6,767,512 and 7,074,367. Bio-Rad Laboratories, Inc. Life Science Group Web site www.bio-rad.com USA 800 424 6723 Australia 61 2 9914 2800 Austria 01 877 89 01 Belgium 09 385 55 11 Brazil 55 31 3689 6600 Canada 905 364 3435 China 86 21 6169 8500 Czech Republic 420 241 430 532 Denmark 44 52 00 Finland 09 804 22 00 France 01 47 95 69 65 Germany 089 31 884 0 Greece 30 2 777 4396 Hong Kong 852 2789 3300 Hungary 36 1 459 60 India 91 124 4029300 Israel 03 963 6050 Italy 39 02 216091 Japan 03 6361 7000 Korea 82 2 3473 4460 Malaysia 60 3 2117 5260 Mexico 52 555 488 7670 The Netherlands 0318 540666 New Zealand 64 9 415 2280 Norway 23 38 41 30 Poland 48 22 331 99 99 Portugal 351 21 472 7700 Russia 7 495 721 14 04 Singapore 65 6415 3170 South Africa 27 861 246 723 Spain 34 91 590 5200 Sweden 08 555 12700 Switzerland 061 717 95 55 Taiwan 886 2 2578 7189 Thailand 66 2 6518311 United Kingdom 020 8328 2000 Vietnam 84 8 38131140 Bulletin 5589 Rev C US/EG -1759 12 Sig 11