EDF Extended Depth of Field



Similar documents
FlowSight. Flow cytometry with vision

CyAn : 11 Parameter Desktop Flow Cytometer

Image Data Exploration and Analysis Software User s Manual

Cytometry without limits

Introduction to Flow Cytometry

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Preparation of Blood Films

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Granulocytes vs. Agranulocytes

Subtypes of AML follow branches of myeloid development, making the FAB classificaoon relaovely simple to understand.

LABORATORY 2 Staining and processing of blood parasites Differential counts of leukocytes (giemsa stains)

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Interphase (A) and mitotic (B) D16 cells were plated on concanavalin A and processed for

FITC Annexin V/Dead Cell Apoptosis Kit with FITC annexin V and PI, for Flow Cytometry

ABO-Rh Blood Typing Using Neo/BLOOD

Lab 02: Blood Cytology (20 points)

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Hematology Morphology Critique

ABO-Rh Blood Typing With Synthetic Blood

Pathology No: SHS-CASE No. Date of Procedure: Client Name Address

SEED Haematology. Sysmex Educational Enhancement and Development February 2013

BD FACSComp Software Tutorial

EDUCATIONAL COMMENTARY - GRANULOCYTE FORMATION AND CHRONIC MYELOCYTIC LEUKEMIA

Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides

Cell Cycle Tutorial. Contents

Introduction to Flow Cytometry

What Cytometry Can Do for You: The Pros and Cons of Image and Flow Cytometry Webinar 31 October 2012

Introduction to flow cytometry

Laboratory 12 Blood Cells

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Z-Stacking and Z-Projection using a Scaffold-based 3D Cell Culture Model

INSIDE THE BLACK BOX

Cardiovascular System. Blood Components

Analyzer Experiment setup guide for LSRII and Canto s

Cell Viability Assays: Microtitration (MTT) Viability Test Live/Dead Fluorescence Assay. Proliferation Assay: Anti-PCNA Staining

SUPPLEMENTARY DATA 1

Cytell Cell Imaging System

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

Immunophenotyping peripheral blood cells

CHROMOSOMES Dr. Fern Tsien, Dept. of Genetics, LSUHSC, NO, LA


NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12

Neuro imaging: looking with lasers in the brain

Image Analysis Using the Aperio ScanScope

White Blood Cells (WBCs) or Leukocytes

Exercise 9: Blood. Readings: Silverthorn 5 th ed, , ; 6 th ed, ,

APPLICATION INFORMATION

inform V2.0.2 User's Manual

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

Boundary-breaking acoustic focusing cytometry

Cytology : first alert of mesothelioma? Professor B. Weynand, UCL Yvoir, Belgium

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

FDA Regulation of Whole Slide Imaging (WSI) Devices: Current Thoughts

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

International Beryllium Conference, Montreal, Canada March 10, 2005

These particles have something in common

BC Auto Hematology Analyzer

inform Advanced Image Analysis Software For Accurately Quantifying Biomarkers in Tissue Sections

MetaXpress Image Acquisition and Analysis Software. Analysis Guide Version 2.0 for Microsoft Windows XP

Standardization, Calibration and Quality Control

March 19, Dear Dr. Duvall, Dr. Hambrick, and Ms. Smith,

Haematopoietic Chimerism Analysis after Allogeneic Stem Cell Transplantation

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

Institut für Experimentelle Immunologie und Bildgebung

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Mitosis in Onion Root Tip Cells

M. Lejeune, C. López, V. Gestí, B. Tomás, A. Korzynska, A. Roso, C. Callau, R. Bosch, J. Baucells, J. Jaén. Digital image analysis

MetaMorph Software Basic Analysis Guide The use of measurements and journals

BLOOD FILM STAINING EFFECTS

Plant and Animal Cells

Outline. 1. Experiment. 2. Sample analysis and storage. 3. Image analysis and presenting data. 4. Probemaker

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

GETTING STARTED. 6. Click the New Specimen icon.

BD CellQuest Pro Software Analysis Tutorial

COMPENSATION MIT Flow Cytometry Core Facility

Introduction to Pattern Recognition

Lenses and Apertures of A TEM

Imaging and Bioinformatics Software

The following chapter is called "Preimplantation Genetic Diagnosis (PGD)".

Fluorescence Compensation. Jennifer Wilshire, PhD

serology Agglutination Techniques and Blood Cell Identification

FlowJo Basic Tutorial

Cells. Introduction WSBCTC 1

Leukemias and Lymphomas: A primer

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Comparison of Non-linear Dimensionality Reduction Techniques for Classification with Gene Expression Microarray Data

Uses of Flow Cytometry

PREPARED FOR: U.S. Army Medical Research and Materiel CommandFort Detrick, Maryland

Minimal residual disease detection in Acute Myeloid Leukaemia on a Becton Dickinson flow cytometer

Whole Blood Flow Cytometry

Notes on titering antibodies

EDUCATIONAL COMMENTARY RED BLOOD CELLS AND WHITE BLOOD CELLS IN URINALYSIS

Cell Cycle in Onion Root Tip Cells (IB)

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit G June Beckman Coulter, Inc N. Harbor Blvd. Fullerton, CA 92835

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

Transcription:

EDF Extended Depth of Field An upgrade for the ImageStream system Think outside the dot.

Break the classic depth of field barrier Improve precision Enhance discrimination Simplify analysis Increase resolution Reduce acquisition time Enable new applications

EDF technology takes your ImageStream to an entirely new level of performance. Images the Whole Cell in Focus EDF uses a combination of specialized optics and unique image processing algorithms to project all structures within the cell into one crisp plane of focus. Figure 1 shows the effect of progressive defocus on a test pattern of 2μ bars. Figure 2 shows how the same pattern imaged with EDF technology maintains excellent image quality over the entire focus range. Enables High Throughput FISH In Suspension (FISHIS ) Counting FISH spots accurately requires that all spots be in focus. Since spots may be located anywhere in the nucleus, maintaining focus throughout the cell is critical. EDF technology expands the depth of focus over the entire cell to make FISH in flow a reality. 0 μm defocus 2 μm defocus 4 μm defocus monosomy frequency monosomy frequency 8 μm defocus figure 1 figure 2 Based on Wavefront Coded technology developed by CDM Optics, Inc. Figure 3 Human male PBMC cells were stained with an X chromosome probe and imaged in standard and EDF modes. In, the FISH spots are detected but can be fuzzy and out of focus, impairing accurate chromosomal counts. In EDF mode, the spots are uniformly in focus throughout the depth of the cell. Automated FISH spot counting accuracy with EDF is dramatically improved. In, just 72 percent of the in-focus cells were characterized as having the expected single spot, while with EDF mode 98 percent of all cells exhibited a single FISH spot.

EDF technology dramatically extends the depth of field, enabling new applications and Improves Nuclear Foci Counting Radiation-induced DNA strand breaks can be identified by staining phosphorylated γ-h2ax. The ImageStream with EDF technology enables precise counting of the foci within the nucleus to assess damage on an individual cell level. Enhances Discrimination of Nuclear Translocation EDF technology enhances the discrimination of cellular features and improves precision in the quantitative analysis of cell imagery. EDF eliminates the need to apply a focus gate to the cell image data. For analyses that are sensitive to focus quality, such as NF-κB translocation, removing this subjective step from the analysis improves the overall reliability of statistical results. Untreated LPS Untreated LPS nuclear spot count nuclear spot count degree of translocation degree of translocation Mean = 4.6 Std = 3.81 Mean = 14.4 Std = 4.08 Figure 4 Irradiated H1299 cells were labeled with AlexaFluor 488 to stain γ-h2ax and DAPI to stain the nucleus. The standard image panel and the EDF image panel show brightfield (column 1), DAPI (column 2), AF488 (column 3) and a composite of AF488 and DAPI (column 4). The resolution obtained with EDF mode reveals significantly more distinct spots, providing a more precise and accurate spot count measurement. Figure 5 The experiment shown here was designed to measure the translocation of NF-κB from cytoplasm to nucleus. A panel showing untreated cells and LPS-stimulated cells is shown as imaged in and EDF mode. The degree of translocation is quantitated by the degree of similarity between the NF-κB image (FITC stain) and the nuclear image (DRAQ5 stain), which is calculated for each cell. As shown in the histograms and indicated by the Rd values, EDF improves the discrimination between the untreated and LPS-stimulated populations.

improving the performance of existing applications. Allows Visual Confirmation of Leukocyte Cell Classification by Nuclear Morphology In traditional microscopic analysis, nuclear morphology is the gold standard for leukocyte classification. EDF improves the resolution of nuclear detail, thereby providing the means to confirm immunophenotypic classification. Increases Throughput In addition to keeping the whole cell in focus, the EDF extended depth of field upgrade allows the ImageStream to be run with a larger core diameter, thereby increasing throughput. Eosinophil standard core size of 10μm edf technology enables a larger core of 16μm Neutrophil Monocyte Basophil Lymphocyte cd45 vs. ssc cd45 vs. ssc Figure 6 Human whole blood was stained with FITC anti-cd45 (green) and DRAQ5 nuclear dye (red) and run on the ImageStream in standard and EDF imaging modes. The five major cell types are cleanly differentiated, and representative images of each are shown. EDF dramatically improves the imaging of nuclear chromatin structure and nuclear lobicity. Figure 7 In, the ImageStream is run with a 10μm core. EDF enables the use of a 16μm core with virtually no loss of cell focus, effectively increasing the throughput by up to 3X.

Ordering information EDF Extended Depth of Field Option The EDF upgrade to the ImageStream system includes all required modifications to the instrument and IDEAS software, installation, testing, documentation and user training. The EDF upgrade can be included with a new ImageStream system or installed as a field upgrade. catalog no. 200200 Amnis Corporation 2505 Third Avenue Suite 210 Seattle, WA 98121 +1.206.374.7000 Phone 1.800.730.7147 U.S. Toll-Free +1.206.576.6895 Fax www.amnis.com