DCS Input/Output Relay Card Series



Similar documents
Cross-beam scanning system to detect slim objects. 100 mm in

Absolute Rotary Encoder E6CP

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Circuit Breakers. NRC Series. NRC Series

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

Solid-State Timer H3G

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Air damper actuators

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Contents. Document information

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

Application Note TMA Series

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

CQM1-SF200/CS1W-SF200

GAE953 Electrical Alarm Unit 19" with Indicator

UIM2901-5A MACH3 breakout board

Inductive sensor NI10-M18-Y1X-H1141

IEC Connectors. Introduction

WD-AMX Water Detection Controllers

Cable Plug acc. to DIN EN , Form A

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

QR12 (1.22 ) Diameter Optical Encoder

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Solid-State Relays. Series Included. Solid-State Relays SIR SLR NLF PHS Series PHS...148

Digital Keypad Use s Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Model CS 64 Mini-DIN Cable and Adaptor

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Telefon (+45) Telefax (+45) Installation and operating manual

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Smart DeviceNet Remote I/O Terminals

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

USER MANUAL V5.0 ST100

Incremental Rotary Encoder E6B2

Contractors Guide Central Inverter System Installation

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Know-how makes the difference. Electrical Actuators

REGULINE 600VA / 1000VA REGULATOR USER MANUAL


ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

How To Power A Schen

T1 Backhaul Connectivity Solution All Products :: Application Note

DCP Fan Controller. Version 01/2009. The engineer s choice

Adjustment functions for both span and shift have been incorporated

MechoNet TM Network Interface (MNI) Specification Submittal

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Digital Pressure Measuring Instrument MDR480

38 Series - Relay interface modules A

Inductive Proximity Sensors

Power Supplies 3. SDN-P DIN Rail Series

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Color Mark Sensor with Red or Green LED E3S-VS

FIREDEX Conventional Fire Panels

LOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

RY2 miniature industrial relays

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

SELECTION GUIDE. Nominal Input

Section D..General Auto Electrical Corporation

BITMAIN. APW PSU Series User Guide

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

SECTION VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

U-shaped Micro Photoelectric Sensor

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Water Leak Detection System

TS93 EMR T/PT/TDE. Surface applied door closer

Vario-Series Accessories

12V Dimmable Driver EL-TMDRVR

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

MCR1900 Media Converter 19-Slot Chassis

Features, Benefits, and Operation

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

MasterINTERFACE 39 Series - Relay interface modules

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

Transcription:

Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test function simplifies startup and maintenance. The Standard Rack (Nest) model 8N can accept at the maximum of 16 channels of inputs and outputs. Input and output on one card Output /OFF switch and LED indicating relay status Test switch provided for checking operation Fuse provided to each channel for electromagnetic valve Output current capacity A Output can be jumper selectable: voltage output for electromagnetic valve or dry contact output. & SUFFIX CODE SELECTI CNECTOR H1 : Hitachi connector Y1 :Yokogawa KS2 cable use connector OPTIS Mounting : Rack mounting, standard (blank) /W : Surface mounting < STANDARD RACK (nest) > 8N B TERMINAL CNECTI CTROLLER CTROLLER CN1 CN2 1 2 5 6 U(+) V( ) POWER FOR VOLTAGE FUSE ALARM FOR VOLTAGE + 2VDC POWER ORDERING INFORMATI Specify code number. (e.g. 8N-BH1) MOUNTING REQUIREMENTS mm (inch) GENERAL SPECIFICATIS Construction: metal plates assembly; angle bracket mounting; JIS or EIA standard rack Capacity: 16 positions Painting: black Power input: supplied to I/O cards collectively Output: front accessed connector and screw terminals; one fuse alarm output for all 16 channels Screw terminal material: nickel-plated brass (torque 0.8 N m) INSTALLATI Power input: 2V DC ±10% (ripple 10% p-p max.) Operating temperature: -5 to +55 C (2 to 11 F) Operating humidity: 0 to 90% RH (non-condensing) Mounting: rack or surface Dimensions: W80 H19 D11 mm (18.90" 5.87" 5.16") Weight: 2.5 kg (5.5 lbs) PERFORMANCE Insulation resistance: 100MΩ with 500V DC Dielectric strength: 1000V AC @1 minute 101.6 (.00)* 65 (18.1) 50 (17.72) M5 SCREW ANGLE BRACKET Observe an appropriate wiring space below. *100 (.9) for JIS standard P. 1 / 10

8N EXTERNAL DIMENSIS mm (inch) RACK (standard) SURFACE (option /W) (17.8) 28 (1.10) 10 (.06) 1.6 (.06) 11 (5.16) CNECTOR CNECTOR 80 (18.90) 65 (18.1) 19 (5.87) 101.6 (.00) 5 6 7 8 9 10 11 12 1 1 15 16 C N 1 C N 2 1256 M.5 MTG SCREWS RACK TERMINALS HITACHI 8N-BH1: Hitachi connector Amphenol 57, 6-pin Connector Pin Assignments CN1: input CN2: output PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT 1 ch. 1 + 9 ch. 9 + 2 ch. 2 + 10 ch.10 + ch. + 11 ch.11 + ch. + 12 ch.12 + 5 ch. 5 + 1 ch.1 + 6 ch. 6 + 1 ch.1 + 7 ch. 7 + 15 ch.15 + 8 ch. 8 + 16 ch.16 + 19 COM 27 COM 17, 18, 20 26, 28 6: Unused Pin assignments are the same for both CN1 and CN2. YOKOGAWA 8N-BY1: Yokogawa connector PS-0PE-DLT1-PN1 Location for ST card CN1: input (KS2 cable use) CN2: output (KS2 cable use) 8-RACK LOCATI NO. 5 6 7 8 9 10 11 12 1 1 15 16 5 6 7 8 9 10 11 12 1 1 15 16 ST2 / ST / ST CARD / NO. Pin assignments are the same for both CN1 and CN2. Specifications subject to change without notice. P. 2 / 10

& SUFFIX CODE SELECTI 8N 2 Dry contact or open collector Voltage or dry contact (jumper selectable) FUNCTI 2 :Test circuit ORDERING INFORMATI Specify code number. (e.g. 8N-2) GENERAL SPECIFICATIS Construction: rack mounted; terminal access via screw terminals at the front and via connector at the rear Connection Input: M.5 screw terminals I/O: card-edge connector Output: M.5 screw terminals Power input: supplied from card-edge connector Screw terminal material: nickel-plated steel (torque 0.8 N m) Fuse: 0.5A Alarm contact: dry contact output at the screw terminal when the fuse is blown Isolation: input or power to output Test switch: LED provided DISCTINUED Replaced with Model 8N2-2 CTACT : dry contact or open collector Contact detecting: 2V DC, approx. 20mA < LOOPBACK I/O RELAY CARD > ELECTROMAGNETIC VALVE: voltage contact Rated load: 120V AC @0.5A (cosø=1) 2V DC @0.5A (resistive load) Load current: 8A max. for the total of 16 channels DRY CTACT: dry contact (electromagnetic valve or dry contact selectable with the jumper on the PCB) Rated load: 120V AC @A (cosø=1) 2V DC @A (resistive load) Relay protection: For maximum relay life with inductive loads (e.g. coil), external protection including noise quenching is recommended. STATUS : relay contact Rated load: 0V DC @A (resistive load) INSTALLATI Power input: 2V DC ±10%, approx. 5mA (ripple 10% p-p max.) Operating temperature: -5 to +55 C (2 to 11 F) Operating humidity: 0 to 90% RH (non-condensing) Mounting: Standard Rack 8N-B Dimensions: W2 H19 D102 mm (0.91" 5.87".02") Weight: 150 g (0. lbs) PERFORMANCE Insulation resistance: 100MΩ with 500V DC Dielectric strength: 1000V AC @1 minute Relay life: mechanical life 5 10 7 cycles electrical life 10 5 cycles (0 cycles/min. at rated load) FRT VIEW mm (inch) STATUS : dry contact or open collector Contact detecting: 2V DC, approx. 20mA SW2 LED 19 (5.87) FUSE M.5 SCREWS 2 (.91) P. / 10

8N OPERATIS SW2 LED LED STATUS STATUS (IN) CTACT A* CTACT B* (OUT) OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF / OFF OFF / OFF OFF OFF TEST / OFF OFF OFF OFF OFF / OFF OFF OFF OFF OFF OFF N/A OFF OFF N/A *Selectable with a jumper. SCHEMATIC CIRCUITRY & CNECTI DIAGRAM POWER CNECTOR JUMPER 2 B A TEST X1 X2 X SW2 X OFF POWER FOR VOLTAGE FUSE ALARM FOR VOLTAGE ALARM FUSE CTACT ELECTRO- MAGNETIC VALVE CARD TERMINALS DRY CTACT When the dry contact output is selected with the jumper. Specifications subject to change without notice. P. / 10

& SUFFIX CODE SELECTI 8N2 2 Dry contact or open collector Voltage or dry contact (jumper selectable) FUNCTI 2 :Test circuit ORDERING INFORMATI Specify code number. (e.g. 8N2-2) GENERAL SPECIFICATIS Construction: rack mounted; terminal access via screw terminals at the front and via connector at the rear Connection Input: M.5 screw terminals I/O: card-edge connector Output: M.5 screw terminals Power input: supplied from card-edge connector Screw terminal material: nickel-plated steel (torque 0.8 N m) Fuse: 0.5A Alarm contact: dry contact output at the screw terminal when the fuse is blown Isolation: input to power or output or contact input to electromagnetic valve output (or dry contact output) to alarm output Test switch: LED provided CTACT : dry contact or open collector Contact detecting: 2V DC, approx. 25mA STATUS : dry contact or open collector Contact detecting: 2V DC, approx. 25mA < LOOPBACK I/O RELAY CARD > ELECTROMAGNETIC VALVE: voltage contact Rated load: 120V AC @0.5A (cosø=1) 2V DC @0.5A (resistive load) Load current: 8A max. for the total of 16 channels DRY CTACT: dry contact (electromagnetic valve or dry contact selectable with the jumper on the PCB) Rated load: 120V AC @A (cosø=1) 2V DC @A (resistive load) Relay protection: For maximum relay life with inductive loads (e.g. coil), external protection including noise quenching is recommended. STATUS : relay contact Rated load: 0V DC @A (resistive load) INSTALLATI Power input: 2V DC ±10%, approx. 65mA (ripple 10% p-p max.) Operating temperature: -5 to +55 C (2 to 11 F) Operating humidity: 0 to 90% RH (non-condensing) Mounting: Standard Rack 8N-B Dimensions: W2 H19 D102 mm (0.91" 5.87".02") Weight: 150 g (0. lbs) PERFORMANCE Insulation resistance: 100MΩ with 500V DC Dielectric strength: 1000V AC @1 minute Relay life: mechanical life 5 10 7 cycles electrical life 10 5 cycles (0 cycles/min. at rated load) FRT VIEW mm (inch) SW2 LED 19 (5.87) FUSE M.5 SCREWS 2 (.91) P. 5 / 10

8N OPERATIS SW2 LED LED STATUS STATUS (IN) CTACT A* CTACT B* (OUT) OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF / OFF OFF / OFF OFF OFF TEST / OFF OFF OFF OFF OFF / OFF OFF OFF OFF OFF OFF N/A OFF OFF N/A *Selectable with a jumper. SCHEMATIC CIRCUITRY & CNECTI DIAGRAM POWER CNECTOR JUMPER 2 B A TEST X1 X2 X SW2 X OFF POWER FOR VOLTAGE FUSE ALARM FOR VOLTAGE ALARM FUSE CTACT ELECTRO- MAGNETIC VALVE CARD TERMINALS DRY CTACT When the dry contact output is selected with the jumper. Specifications subject to change without notice. P. 6 / 10

DISCTINUED Replaced with Model 8N2- & SUFFIX CODE SELECTI Dry contact or open collector Relay contact FUNCTI : Motor drive use ORDERING INFORMATI Specify code number. (e.g. 8N-) <MOTOR DRIVE I/O RELAY CARD > 8N INSTALLATI Power input: 2V DC ±10%, approx. 80mA (ripple 10% p-p max.) Operating temperature: -5 to +55 C (2 to 11 F) Operating humidity: 0 to 90% RH (non-condensing) Mounting: Standard Rack 8N-B Dimensions: W2 H19 D102 mm (0.91" 5.87".02") Weight: 150 g (0. lbs) PERFORMANCE Insulation resistance: 100MΩ with 500V DC Dielectric strength: 1000V AC @1 minute Relay life: mechanical life 5 10 7 cycles electrical life 10 5 cycles (0 cycles/min. at rated load) GENERAL SPECIFICATIS Construction: rack mounted; terminal access via screw terminals at the front and via connector at the rear Connection Input: M.5 screw terminals I/O: card-edge connector Output: M.5 screw terminals Power input: supplied from card-edge connector Screw terminal material: nickel-plated steel (torque 0.8 N m) Isolation: output or power or feedback input to motor drive to input Indicator LED: orange light turns on when the motor is started up. red light turns on when the feedback input is turned on. FRT VIEW mm (inch) 19 (5.87) 2 (.91) LED (orange) LED (red) M.5 SCREWS FEEDBACK : dry contact or open collector Contact detecting: 2V DC, approx. 25mA STATUS : dry contact or open collector Contact detecting: 2V DC, approx. 50mA MOTOR DRIVE : relay contact Rated load: 250V AC @A (cosø=1) 0V DC @A (resistive load) Relay protection: For maximum relay life with inductive loads (e.g. coil), external protection including noise quenching is recommended. STATUS : relay contact Rated load: 0V DC @A (resistive load) P. 7 / 10

8N OPERATIS t t t Output Feedback Motor Drive t = 2.5 to 5 sec. SCHEMATIC CIRCUITRY & CNECTI DIAGRAM POWER OFF One-Shot Relay Driver 1 FEEDBACK CNECTOR 2 MOTOR DRIVE M X1 X2 X Specifications subject to change without notice. P. 8 / 10

<MOTOR DRIVE I/O RELAY CARD > & SUFFIX CODE SELECTI Dry contact or open collector Relay contact FUNCTI : Motor drive use ORDERING INFORMATI Specify code number. (e.g. 8N2-) GENERAL SPECIFICATIS 8N2 Construction: rack mounted; terminal access via screw terminals at the front and via connector at the rear Connection Input: M.5 screw terminals I/O: card-edge connector Output: M.5 screw terminals Power input: supplied from card-edge connector Screw terminal material: nickel-plated steel (torque 0.8 N m) Isolation: output or power or feedback input to motor drive to input Indicator LED: orange light turns on when the motor is started up. red light turns on when the feedback input is turned on. INSTALLATI Power input: 2V DC ±10%, approx. 95mA (ripple 10% p-p max.) Operating temperature: -5 to +55 C (2 to 11 F) Operating humidity: 0 to 90% RH (non-condensing) Mounting: Standard Rack 8N-B Dimensions: W2 H19 D102 mm (0.91" 5.87".02") Weight: 150 g (0. lbs) PERFORMANCE Insulation resistance: 100MΩ with 500V DC Dielectric strength: 1000V AC @1 minute Relay life: mechanical life 5 10 7 cycles electrical life 10 5 cycles (0 cycles/min. at rated load) FRT VIEW mm (inch) 19 (5.87) LED (orange) LED (red) M.5 SCREWS FEEDBACK : dry contact or open collector Contact detecting: 2V DC, approx. 5mA 2 (.91) STATUS : dry contact or open collector Contact detecting: 2V DC, approx. 60mA MOTOR DRIVE : relay contact Rated load: 250V AC @A (cosø=1) 0V DC @A (resistive load) Relay protection: For maximum relay life with inductive loads (e.g. coil), external protection including noise quenching is recommended. STATUS : relay contact Rated load: 0V DC @A (resistive load) P. 9 / 10

8N OPERATIS t t t Output Feedback Motor Drive t = 2.5 to 5 sec. SCHEMATIC CIRCUITRY & CNECTI DIAGRAM POWER OFF One-Shot Relay Driver 1 FEEDBACK CNECTOR 2 MOTOR DRIVE M X1 X2 X Specifications subject to change without notice. P. 10 / 10