CERTIFICATE OF COMPLIANCE



Similar documents
CERTIFICATE OF COMPLIANCE

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

2.12. page Products for Explosion hazardous Environment

Hazardous Area Classifications and Protections

FCS-MBx-SG Megablock series*

Series 3730 Type Electropneumatic Positioner

Hazardous Area Classifications and Protections


Solenoid Valve Island Type 3965

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

Fisher FIELDVUE DVC2000 Digital Valve

Microcor Wireless Transmitter (MWT)

Inductive sensor NI10-M18-Y1X-H1141

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Worcester DS/DM Series UltraSwitch Switch box

Technical Data. Dimensions

Fisher 846 Electro-Pneumatic Transducer

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas

NOT to be distributed outside of FM Approvals and its affiliates except by CUSTOMER

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Model 3051 Pressure Transmitter with HART Protocol

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Series 3730 Type Electropneumatic Positioner with FOUNDATION fieldbus communication

2002 IS Catalog. Page

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Design of intrinsically safe systems

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

JAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES

Fisher 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Inductive slot sensor

Rosemount 248 Temperature Transmitter

Fisher FIELDVUE DVC6000 Digital Valve Controllers Instruction Manual (Supported)

Rosemount 752 FOUNDATION fieldbus Remote Indicator

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Approval Standard for Land Mobile Radios for use in Class I, Division 1 Hazardous (Classified) Locations

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Rosemount 708 Wireless Acoustic Transmitter

How To Control An Electric Pneumatic Positioner Tzidc

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Triple Waveband Infra-Red Flame Detection

Today's world of increasing

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Fisher i2p-100 Electro Pneumatic Transducer

API Marine. BMS Presentation. Ballast Measurement Systems

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

3500/62 Process Variable Monitor

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Technical Data. Dimensions

FlowPak TM General Application Valve 1/2-4, Class 150

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

SIL in de praktijk (Functional Safety) Antwerpen Compliance of Actuators and Life Cycle Considerations. SAMSON AG Dr.

High-precision valve control using intelligent positioners. sipart

ph/redox Measurement MyPro CPM 431

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

TorqPlus TM Electric Valve Actuators and Controls

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Fisher 846 Current-to-Pressure Transducer

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Intrinsically Safe Barrier Relays NY2 and 8501TO

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Rosemount 751 Field Signal Indicator

LIQ_MAN_ABR_5081P-HT/Rev. M January 2015

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Mobrey open channel flow measurement systems

Sanitary Type Electronic Flow Switches

Repeaters and Mimics Data Sheet

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

FGM 160 ATEX EC type examination certificate

Mobrey Hydrastep and Hydratect

Plastic tube flowmeters Series PT/PS

SELECTION GUIDE. bzg - Zener Barrier.

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Rosemount 3051 Pressure Transmitter. Rosemount 3051CF Series Flowmeter Transmitter

3DLevelScanner II TECHNICAL DATA SHEET

SEISMIC VELOCITY TRANSDUCER T1-40

Relative pressure transmitter type 520

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Transcription:

FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT This certificate is issued for the following equipment: 3730-23-abcdef. e/p-positioner. IS / I,II,III / 1 / ABCDEFG / T6 Ta = 60 C - Addendum to EB 8384-2EN, pages 7-11; Entity; Type 4X I / 0 / AEx ia / IIC / T6 Ta = 60 C - Addendum to EB 8384-2EN, pages 7-11; Entity; Type 4X NI / I / 2 / ABCD / T6 Ta = 60 C; S / II,III / 2 / FG / T6 Ta = 60 C; Type 4X Software Limit Switches: V max (U i ) = 20 V, I max (I i ) = 60 ma, P max (P i ) = 250 m W, C i = 5.3 nf, L i = 0. V max (Ui) = 16 V, I max (I i ) = 25 ma, P max (P i ) = 64 mw, C i = 60 nf, L i = 200 µh, V max (Ui) = 16 V, I max (I i ) = 52 ma, P max (P i ) = 169 mw, C i = 60 nf, L i = 200 µh. Forced Venting Function (Solenoid Valve): V max (U i ) = 28 V, I max (I i ) = 115 ma, P max (P i ) = 500 mw, C i = 5.3 nf, L i = 0. Fault Alarm Output: Programming Jack BU: V max (U i ) = 20 V, I max (I i ) = 60 ma, P max (P i ) = 250 mw, C i = 0, L i = 0, V oc (U o ) = 6.51 V, I sc (I o ) = 57.5 ma, C a (C o ) = 22 µf, L a (L o ) = 10 mh. V oc (U o ) = 6.51 V, I sc (I o ) = 56 ma, C a (C o ) = 11.2 µf, L a (L o ) = 11.6 mh. V max (U i ) = 28 V, I max (I i ) = 100 ma, P max (P i ) = 0.7 W, C i = 5.3 nf, L i = 0. V max (U i ) = 28 V, I max (I i ) = 100 ma, P max (P i ) = 0.7 W, C i = 56.3 nf, L i = 0. a = Limit Switches 0 (not provided), or 1 (provided). b = Solenoid valve 0 (not provided), or 4 (provided). c = Positioner indicator 0 (not provided), or 1 (provided). e = 0 (not provided), or 1 (provided). Page 1 of 5

f = 0 (not provided), or 2 (provided). 3730-33-abcdef. Hart Capable Positioner. IS / I,II,III / 1 / ABCDEFG / T6 Ta = 60 C - Addendum to EB 8384-3EN, pages 7-11; Entity; Type 4X I / 0 / AEx ia / IIC / T6 Ta = 60 C - Addendum to EB 8384-3EN, pages 7-11; Entity; Type 4X NI / I / 2 / ABCD / T6 Ta = 60 C; S / II / 2 / FG / T6 Ta = 60 C; Type 4X V max (U i ) = 28 V, I max (I i ) = 115 ma, P max (P i ) = 1 W, C i = 35 nf, L i = 0. V max (U i ) = 20 V, I max (I i ) = 60 ma, P max (P i ) = 250 mw, C i = 13.4 nf, L i = 0. V max (U i ) = 16 V, I max (I i ) = 25 ma, P max (P i ) = 64 mw, C i = 60 nf, L i = 100 µh, V max (U i ) = 16 V, I max (I i ) = 52 ma, P max (P i ) = 169 mw, C i = 60 nf, L i = 100 µh. V max (U i ) = 28 V, I max (I i ) = 115 ma, P max (P i ) = 0.5 W, C i = 5.3 nf, L i = 0. V max (U i ) = 20 V, I max (I i ) = 60 ma, P max (P i ) = 250 mw, C i = 13.4 nf, L i = 0. V max (U i ) = 16 V, I max (I i ) = 25 ma, P max (P i ) = 250 mw, C i = 0, L i = 0, V oc (U o ) = 7.88 V, I sc (I o ) = 61.8 ma, P max P o = 120 mw, C a (C o ) = 0.65 µf, L a (L o ) = 10 mh. V oc (U o ) = 7.88 V, I sc (I o ) = 61 ma, P max (P o ) = 120 mw, C a (C o ) = 0.66 µf, L a (L o ) = 10 mh, or C i = 730 nf, L i = 370 µh. V max (U i ) = 28 V, I max (I i ) = 100 ma, P max (P i ) = 0.7 W, C i = 5.3 nf, L i = 0. V max (U i ) = 28 V, I max (I i ) = 100 ma, P max (P i ) = 0.7 W, C i = 56.3 nf, L i = 0. a = Proximity Switches 0 (not provided), or 1 (provided). b = Force venting Function 0 (not provided), or 4 (24 Vdc provided). c = Position indicator 0 (not provided), or 1 (provided). e = 0 (not provided), or 1 (provided). f = 0 (not provided), or 2 (provided). 3730-6-130abcd0ef00g. Digital Hart Positioner. IS / I,II,III / 1 / ABCDEFG / T6 Ta = 60 C - Addendum to EB 8384-6 EN, pages 7-12; Entity; Type 4X I / 0 / AEx ia / IIC / T6 Ta = 60 C - Addendum to EB 8384-6 EN, pages 7-12; Entity; Type 4X NI / I / 2 / ABCD / T6 Ta = 60 C - Addendum to EB 8384-6 EN, pages 7-12; NIFW; Type 4X S / II, III / 2 / EFG / T6 Ta = 60 C - Addendum to EB 8384-6 EN, pages 7-12; NIFW; Type 4X V max (U i ) = 32 V, I max (I i ) = 87.5 ma, P max (P i ) = 1 W, C i = 5.3 nf, L i = 0. Page 2 of 5

V max (U i ) = 32 V, I max (I i ) = 87.5 ma, P max (P i ) = 1 W, C i = 5.3 nf, L i = 0. V max (U i ) = 16 V, I max (I i ) = 25 ma, P max (P i ) = 64 mw, C i = 30 nf, L i = 100 µh. V max (U i ) = 16 V, I max (I i ) = 52 ma, P max (P i ) = 169 mw, C i = 30 nf, L i = 100 µh. V max (U i ) = 32 V, I max (I i ) = 87.5 ma, P max (P i ) = 1 W, C i = 5.3 nf, L i = 0. V max (U i ) = 20 V, I max (I i ) = 60 ma, P max (P i ) = 200 mw, C i = 0, L i = 0, V oc (U o ) = 7.88 V, I sc (I o ) = 69.2 ma, P max P o = 137 mw, C a (C o ) = 650 nf, L a (L o ) = 10 mh. V oc (U o ) = 7.88 V, I sc (I o ) = 13.2 ma, P max (P o ) = 27 mw, C a (C o ) = 1 µf, L a (L o ) = 10 mh, or C i = 66 nf, L i = 370 µh. C i = 5.3 nf, C o = 1.4 nf. V max (U i ) = 30 V, I max (I i ) = 100 ma, C i = 56.3 nf, L i = 0. Non-Incendive Field Wiring Parameters: V max (U i ) = 20 V, C i = 5.3 nf, L i = 0. V max (U i ) = 16 V, C i = 30 nf, L i = 100 µh. V max (U i ) = 20 V, C i = 5.3 nf, L i = 0. V max (U i ) = 20 V, C i = 0, L i = 0, V oc (U o ) = 7.88 V, C a (C o ) = 650 nf, L a (L o ) = 10 mh. V oc (U o ) = 7.88 V, C a (C o ) = 1 µf, L a (L o ) = 10 mh, or C i = 66 nf, L i = 370 µh. C i = 5.3 nf, C o = 1.4 nf. V max (U i ) = 30 V, C i = 56.3 nf, L i = 0. a = Proximity Switches 0 (not provided), or 1 (provided). b = Venting Function 0 (not provided), or 1 (Solenoid valve 24 V DC) or 2 (Forced venting 24 V DC). c = Position indicator 0 (not provided), or 1 (Position transmitter), or 2 (Leakage Detection), or 3 (Binary Input). e = Emergency shutdown 0 (3.8 ma), or 1 (4.4 ma). f = Body Material 0 (Die-cast aluminum), or 1 (Stainless Steel). g = Housing cover 00 (Cover standard version), or 02 (Cover without window). Page 3 of 5

Equipment Ratings: Intrinsically safe for use in Class I, II, III, Division 1, Groups A, B, C, D, E, F and G; Class I, Zone 0, IIC in accordance with control drawing nos. Addendum to EB 8384-2EN, pages 7 11, Addendum to EB 8384-3EN, pages 7 11 and Addendum to EB 8384-6EN, pages 7 12. Nonincendive with Nonincendive Field Wiring for Class I, Division 2, Groups A, B, C and D; Suitable for Class II, III, Division 2, Groups F and G or E, F and G indoor/outdoor Type 4X hazardous (Classified) Locations. FM Approved for: Samson AG D-60314 Frankfurt, Germany Page 4 of 5

This certifies that the equipment described has been found to comply with the following Approval Standards and other documents: Class 3600 2011 Class 3610 2010 Class 3611 2004 Class 3810 2005 NEMA-250 2003 ANSI/ISA-60079-0 2009 ANSI/ISA-60079-11 2009 Original Project ID: 3012394 Approval Granted: December 4, 2002 Subsequent Revision Reports / Date Approval Amended Report Number Date Report Number Date 3018702 02/02/2004 3034227 11/03/2008 3042057 06/06/2011 Reissued August 11, 2011 3044364 November 5, 2014 FM Approvals LLC J.E. Marquedant Group Manager, Electrical 5 November 2014 Date Page 5 of 5