CERTIFICATE OF COMPLIANCE
|
|
|
- Suzanna Short
- 9 years ago
- Views:
Transcription
1 FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA USA T: F: CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT This certificate is issued for the following equipment: V b1defghijk. Sensyflow FMT500- ig Integral Version XP-IS / I / 1 / BCD / T* Ta = 50 C XP-IS / I / 1 / IIB / T* Ta = 50 C Analog output connection terminals 31 and 32 of connector: Page 1 of 5
2 V b1defghijk. Sensyflow FMT500- ig Integral Version NI-IS / I, II, III / 2 / ABCDFG / T* Ta = 50 C NI-IS / I / 2 / IIC / T* Ta = 50 C Analog output connection terminals 31 and 32 of connector: V b1defghijk. Sensyflow FMT500- ig Remote Transmitter NI-AIS / I / 2 / ABCD / T* Ta = 50 C I / 2 / AEx na [ia] / IIC / T* Ta = 50 C Page 2 of 5
3 Analog output connection terminals 31 and 32 of connector: V b1de2ghijk. Sensyflow FMT500- ig Remote Sensor IS / I / 1 / ABCD / T* Ta = 80 C I / 0 / AEx ia / IIC / T* Ta = 80 C NI / I, II, III / 2 / ABCD / T* Ta = 80 C I / 2 / IIC / T* Ta = 80 C DIP / II, III / 1 / EFG / T* Ta = 80 C V ; Entity; Type 4X, IP67 Page 3 of 5
4 Equipment Ratings: Compact Version - Explosionproof for Class I, Division 1, Groups B, C and D; and for Class I, Zone 1 Group IIB with intrinsically-safe circuits for Class I, Division 1, Groups B, C and D; Class I, Zone 0 AEx ia IIB; dust-ignitionproof for Class II, III, Division 1, Groups E, F and G; and non incendive for Class I, Division 2, Groups A, B, C, D, F and G; Class I, Zone 2 Group IIC; and intrinsically-safe sensor for Class I, Division 1, Groups A, B, C and D; Class I, Zone 0 AEx ia IIC hazardous (classified) locations, indoors and outdoors (IP67 / Type 4X). Remote Version - Non-incendive for Class I, Division 2, Groups A, B, C, D; Class I, Zone 2 Group IIC; and dust-ignitionproof for Class II, III, Division 1 and 2, Groups E, F and G; with intrinsically-safe circuits for Class I, Division 1, Groups A, B, C and D; Class I, Zone 0 AEx ia IIC hazardous (classified) locations, indoors and outdoors (IP67 / Type 4X). FM Approved for: ABB Automation Products GmbH Dransfelder Strasse 2 Gottingen D37070 Germany Page 4 of 5
5 This certifies that the equipment described has been found to comply with the following Approval Standards and other documents: Class Class Class Class Class ANSI/ISA ANSI/ISA ANSI/ISA ANSI/ISA ANSI/IEC ANSI/NEMA Original Project ID: Approval Granted: March 7, 2008 Subsequent Revision Reports / Date Approval Amended Report Number Date Report Number Date August 19, 2013 FM Approvals LLC J. E. Marquedant Group Manager, Electrical 19 August 2013 Date To verify the availability of the Approved product, please refer to Page 5 of 5
CERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
Attachment to GB/FME/ExTR08.006/05 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5**
Approval Standard for Land Mobile Radios for use in Class I, Division 1 Hazardous (Classified) Locations
Approval Standard for Land Mobile Radios for use in Class I, Division 1 Hazardous (Classified) Locations Class Number 3640 June 2013 Copyright 2013 by FM Approvals LLC. All rights reserved. Foreword The
Model 3051 Pressure Transmitter with HART Protocol
Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure
Rosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
Making sense of Intrinsic Safety and Intrinsically Safe Tools
Making sense of Intrinsic Safety and Intrinsically Safe Tools What is Intrinsically Safe? Intrinsic safety is a protection standard employed in potentially explosive atmospheres. Devices that are certified
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Sensyflow FMT500-IG Thermal Mass Flowmeter
Contents Data Sheet 1/14-6.41-EN Rev. H Sensyflow FMT5-IG Thermal Mass Flowmeter Direct mass flow measurement of gases No additional pressure and temperature compensation Digital measured value processing
NOT to be distributed outside of FM Approvals and its affiliates except by CUSTOMER
NOT to be distributed outside of FM Approvals and its affiliates except by CUSTOMER APPROVAL REPORT REVISIONS TO MODEL 2460 STEALTHLITE AND 3660 LITTLE ED LED RECHARGEABLE FLASHLIGHTS FOR USE IN HAZARDOUS
CERTIFICATE OF COMPLIANCE
Certificate Number 20130425-E360130 Report Reference E360130-20130425 Issue Date 2013-APRIL-25 Industrial Control Panels For Use In Class I, Division 1, Groups A, B, C and D Hazardous Locations, Type X
TECHNICAL WHITE PAPER INTRINSICALLY SAFE FIELDBUS IN HAZARDOUS AREAS
TECHNICAL WHITE PAPER INTRINSICALLY SAFE FIELDBUS IN HAZARDOUS AREAS Decision Guidance for Intrinsically Safe Fieldbus Solutions Currently different solutions are available for intrinsically safe fieldbus
FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet 0/-8.5 EN FieldIT Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit)
BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices
March 0 Description The enables new and existing wired smart HART fi eld devices, non-smart analog fi eld devices and remote HART I/O from any supplier to communicate with host applications using technology.
Hazardous Area Classifications and Protections
Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types
Fisher 846 Electro-Pneumatic Transducer
846 Transducer Product Bulletin Fisher 846 Electro-Pneumatic Transducer The Fisher 846 electro-pneumatic transducer is a rugged, field-mountable transducer that accepts an electrical input signal and converts
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
Hazardous Area Classifications and Protections
Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types
Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter
Quick Start Guide 00825-0100-4801, Rev MA May 2015 Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol Quick Start Guide May 2015 NOTICE This guide provides
RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features
GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high
APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement
For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M Compact Operating Instructions Legal information Qualified Personnel The product/system described in this documentation
Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas
Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas 34-XY-03-01, May 2012 Function The WG/A5xx is part of the XYR 5000 family of wireless products.
Connection technology from ifm.
Connection technology from ifm. Connection technology www.ifm.com/gb/connect WARRANTY years on ifm products The right choice for reliable connections. ecolink M. Cannot be overtightened! Due to the special
Fisher FIELDVUE DVC2000 Digital Valve
DVC2000 Digital Valve Controller Product Bulletin Fisher FIELDVUE DVC2000 Digital Valve Controller The FIELDVUE DVC2000 digital valve controller is simple to use, compact, and designed for easy mounting.
LST300. Compact ultrasonic level transmit. Measurement made easy
Safety instruction LST300-EN Rev A LST300 Compact ultrasonic level transmit Measurement made easy Introduction Liquid level measurement has never been easier. LST300 is the most advanced compact level
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
TEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
TEIP11-PS I/P signal converter for standard signals. Measurement made easy
Change from one to tw o c olumns Data Sheet 10/18-0.10-EN Rev. C TEIP11-PS I/P signal converter for standard signals Measurement made easy Proven and reliable concept Compact design Small dimensions, low
Design of intrinsically safe systems
AUTOMATION & C O N T R O L S W here intrinsically safe apparatus is interconnected by wiring, the safety of each piece of apparatus is affected by the performance of the other pieces of apparatus in the
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
LED Driver: LT10. EuP2. Features. Approvals IP20. Markets & Applications. Engineering Drawing. Technical Data
LED Driver: LT10 LT10-16 1-15 VDC 700 ma 1895089 LT10-32 2-30 VDC 350 ma 1895008 High Efficiency: Typ. 83% Low Standby Losses 0,2W LED Driver: LT10 DB LT10-16 1-15 VDC 700 ma 1895542 LT10-32 2-30 VDC 350
Ultima X Series Gas Monitors
Ultima X Series Gas Monitors For continuous monitoring of oxygen, toxics, and combustible gases Now with SIL 2 Certified Products MSA s Ultima X Series Gas Monitors are microprocessor-based transmitters
Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter
3710 and 3720 Positioners Product Bulletin Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter Fisher 3710 pneumatic and 3720 electro-pneumatic positioners are designed for use with either
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
FCS-MBx-SG Megablock series*
technical datasheet technical datasheet FCS-MBx-SG Megablock series* passive hubs for general purpose, Zone & Division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus
GUE, GUB Junction Boxes
E GUE, GUB Junction Boxes Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 4*, BCD, 9EFG Ex d IIC T6, IP66 Ex d IIC, IP66, ATEX certified Explosionproof
Fluke Digital Multimeters Solutions for every need
Fluke Digital Multimeters Solutions for every need How to choose the best DMM for your job Choosing the right digital multimeter (DMM) requires thinking about what you ll be using it for. Evaluate your
D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns
for harsh & hazardous (classfied) locations Construction Demolition Maintenance Turnarounds Shutdowns D-13 temporary / mobile power Temporary power products are used on industrial and construction sites
Differential-Hall-Effect based Sensors Series A5S Overview
A5S Differential-Hall-Effect based Sensors Series A5S Overall View KEY FEATURES Speed range from 0 Hz up to 25 khz (response time < 20 microseconds) Air gap to the target / pole wheel up to 2.5 mm (depending
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Rosemount 751 Field Signal Indicator
Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available
ISpac isolators. the perfect system
ISpac isolators the perfect system 2 safe isolation Handling flammable and potentially explosive substances is part and parcel of everyday operations in many branches of industry. However, it is not possible
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
Rosemount 248 Wireless Temperature Transmitter
Rosemount 248 Wireless Temperature Transmitter Product Data Sheet May 2016 00813-0100-4248, Rev DB Standard temperature transmitter offers a wireless solution for process monitoring Optimize plant efficiency
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134
AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN SP1134 Power and productivity for a better world TM AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN NOTICE This document contains information
P R E F E I T U R A M U N I C I P A L D E J A R D I M
C O N T R A T O N 7 8 / 2 0 1 4 C o n t r a t o d e P r e s t a ç ã o d e S e r v i ç o s A d v o c a t í c i o s q u e e n t r e s i c e l e b r a m o M u n i c í p i o d e J A R D I M - M S e A IR E
FGM 160 ATEX EC type examination certificate
Document number: 75.120.223 Document title: FGM 160 ATEX EC type examination certificate Scope: EN 60079-0, 1, 7, 11, 26 Additional Information (when applicable) F 2015.06.03 New certificate issue Nemko
Siemens AG 2010. Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.
Fieldbus solutions with the SIMATIC PCS 7 distributed control system Brochure April 2010 SIMATIC PCS 7 Answers for industry. Fieldbus solutions with SIMATIC PCS 7 OS multi-clients Engineering station Maintenance/
psens Pressure Measurement
Mobile Machine Control Solutions psens Pressure Measurement Reliable Compact Versatile Unique Measurement Accuracy psens. Pressure Sensors from Hirschmann MCS Hirschmann pressure transducers are an ideal
TTH300 Head-mount temperature transmitter
Operating Instruction OI/TTH300-EN Rev. D TTH300 Head-mount temperature transmitter Measurement made easy Change from one to two columns Short product description Head-mount temperature transmitter for
distributing & controlling system solutions
distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food
Rosemount 708 Wireless Acoustic Transmitter
Product Data Sheet January 2015 00813-0100-4708, Rev BB Rosemount 708 Wireless Acoustic Transmitter Improve energy efficiency and environmental compliance with acoustic monitoring of steam traps and pressure
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
SEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified
IECEx & ATEX 95 CMP PRODUCTS S AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND Triple Certified Single Solution Three Forms of Protection Ex d / Ex e / Ex nr N O O T H E R M A CONTENTS Leading
Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.
Methods of explosion protection for electrical equipment Flammable atmospheres can be ignited by sparks or not surfaces arising from the use of electrical power. Other possible sources of ignition are
AN9003 - A Users Guide to Intrinsic Safety
AN9003 - A Users Guide to Intrinsic Safety Reasons for selecting the Intrinsically Safe Concept 1. Why choose intrinsic safety? 1.1 Introduction Intrinsic safety (IS) is a low-energy signalling technique
Transmissive Optical Sensor with Phototransistor Output
TCST11. up to TCST23. Transmissive Optical Sensor with Phototransistor Output Description This device has a compact construction where the emitting-light sources and the detectors are located face-to-face
Allen-Bradley/Rockwell
MANUFACTURER DATA SHEET Analog I/O Module Manufacturer: Allen-Bradley/Rockwell Model Number: 1746-NI4 See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014624-18 VendorPartNumber:
S-series Mass Connection Solutions
DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination
Rosemount 248 Temperature Transmitter
Product Data Sheet February 2014 00813-0100-4825, Rev KB Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points transmitter design
2002 IS Catalog. Page
00 IS Catalog Page Introduction... 47 Transmitter (8 V entity parameter) KFD-CR-Ex1.30.00 (-wire transmitter)... 48 KFD-CR-Ex1.30.300 (- or 3-wire transmitter)... 49 KFD-CR-Ex1.30.300 90C (- or 3-wire,
Conductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
Worcester DS/DM Series UltraSwitch Switch box
Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
PROCESS AUTOMATION. ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW
PROCESS AUTOMATION Protection for the environment ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW warning devices for separator systems Detects dangers to protect the environment Water is the basis of all
Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure
Myers Hubs The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure Myers Hubs The Original! Often imitated, never duplicated! Available in a wide range of sizes, materials
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
Velomitor Piezo-velocity Sensor
Specifications and Ordering Information Velomitor Piezo-velocity Sensor BENTLY NEVADA MADE IN U.S.A. VELOMITO PN 330500 100 mv/in/s (4 mv/mm/s) Description Velomitor Piezo-velocity Sensors measure absolute
Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet
October 2014 Page 1 Redundant (WIOC) Fully redundant Wireless solution from to the Smart Wireless Field Link Optional simplex for smaller applications Seamless integration with DeltaV system and AMS Suite.
CU-950 Installation Guide
inst ructions separations Installation Guide This instruction describes and provides information on how to install it with ÄKTAbasic, ÄKTAexplorer, ÄKTApurifier, ÄKTAFPLC and ÄKTApilot. 1 Description unit
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
Overview of Standards for CO Detection Products
Overview of Standards for CO Detection Products Rev 1.1 INTEC Controls 12700 Stowe Dr., Suite 100 Poway, CA 92064 The Right Choice [email protected] www.inteccontrols.com Phone: (858) 578-7887 Fax:
HCE80/HCC80/HCE80R/HCC80R
HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp
Buckeye Detection Systems Fixed Detection Systems Application Survey
Buckeye Detection Systems Fixed Detection Systems Application Survey Channel Partner Representative : Company Name: Representative: BDS Representative: Client Contact Information : Company Name: Company
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
New XUY roller sensors
Do you want to simplify the sensor integration in your conveyor systems? New XUY roller sensors for packet, boxes, letters on roller conveyors. Telemecanique Sensor s OsiSense TM XUY photoelectric sensors
Dew-Point Measurement Solutions
Dew-Point Measurement Solutions www.michell.com Dew-Point Measurement Solutions Special Features No downtime Michell Instruments offers a unique sensor exchange programme, which means that you will never
Fisher FIELDVUE DVC6000 Digital Valve Controllers Instruction Manual (Supported)
Supported Product D102794X012 DVC6000 Digital Valve Controllers October 2013 Fisher FIELDVUE DVC6000 Digital Valve Controllers Instruction Manual (Supported) Supported products may not be manufactured
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Device Management Jonas Berge Emerson Process Management
Device Management Jonas Berge Emerson Process Management 1 Topics What is intelligent device management? Integrated operations Why do I need a handheld field communicator? With fieldbus, I can do everything
Safety instructions VEGADIS DIS81.CEIA/V****
Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application
Fisher 846 Current-to-Pressure Transducer
Instruction Manual 846 Transducer Fisher 846 Current-to-Pressure Transducer Contents 1. Introduction Scope of Manual... 2 Description... 2 Specifications... 2 Related Documents... 5 Educational Services...
Rosemount 2088 Absolute and Gage Pressure Transmitter
Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.075% with High Accuracy option Lightweight, compact design for cost effective installation Protocols
ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors
Installation Instructions P/N MMI-20015054, Rev. AA May 2009 ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors For ATEX-approved sensor installations Note: For hazardous installations