Out-of-box comparison between Dell and HP blade servers



Similar documents
Out-of-box comparison between Dell, HP, and IBM blade servers

Figure 1A: Dell server and accessories Figure 1B: HP server and accessories Figure 1C: IBM server and accessories

How To Compare Two Servers For A Test On A Poweredge R710 And Poweredge G5P (Poweredge) (Power Edge) (Dell) Poweredge Poweredge And Powerpowerpoweredge (Powerpower) G5I (

Summary. Key results at a glance:

RESOLVING SERVER PROBLEMS WITH DELL PROSUPPORT PLUS AND SUPPORTASSIST AUTOMATED MONITORING AND RESPONSE

SERVER POWER CALCULATOR ANALYSIS: CISCO UCS POWER CALCULATOR AND HP POWER ADVISOR

Figure 2: Dell offers significant savings per chassis over HP and IBM in acquisition costs and 1-, 3-, and 5-year TCO.

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

TEST REPORT Dell PERC H700 average percentage win in IOPS over FEBRUARY 2006 Dell PERC 6/i across RAID 5 and RAID 10. Internal HDD tests

Digi International: Digi One IA RealPort Latency Performance Testing

Adaptec: Snap Server NAS Performance Study

Adaptec: Snap Server NAS Performance Study

Power Efficiency Comparison of Enterprise-Class Blade Servers and Enclosures

VIRTUALIZATION-MANAGEMENT COMPARISON: DELL FOGLIGHT FOR VIRTUALIZATION VS. SOLARWINDS VIRTUALIZATION MANAGER

A PRINCIPLED TECHNOLOGIES TEST REPORT WORKSTATION PRODUCTIVITY WITH THE DUAL-PROCESSOR LENOVO THINKSTATION D20 AUGUST 2011

TEST REPORT OCTOBER 2008 Performance of Dell and HP servers running Windows Small Business Server 2008

System Configuration and Order-information Guide ECONEL 100 S2. March 2009

A PRINCIPLED TECHNOLOGIES TEST REPORT SHAREPOINT PERFORMANCE: TREND MICRO PORTALPROTECT VS. MICROSOFT FOREFRONT JULY 2011

TEST REPORT OCTOBER 2009 SMB Workload performance testing: PowerEdge T110 vs. an older small business desktop running typical small

How To Perform A File Server On A Poweredge R730Xd With Windows Storage Spaces

EVGA Z97 Classified Specs and Initial Installation (Part 1)

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

HP reference configuration for entry-level SAS Grid Manager solutions

Chapter 5 Cubix XP4 Blade Server

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual

How To Write An Article On An Hp Appsystem For Spera Hana

Cisco MCS 7825-H3 Unified Communications Manager Appliance

DD670, DD860, and DD890 Hardware Overview

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

HP Power Advisor utility: a tool for estimating power requirements for HP ProLiant server systems

VERITAS Software - Storage Foundation for Windows Dynamic Multi-Pathing Performance Testing

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

TS500-E5. Configuration Guide

Cisco MCS 7816-I3 Unified Communications Manager Appliance

WEB SERVER PERFORMANCE: DELL SERVERS

A PRINCIPLED TECHNOLOGIES TEST REPORT VIDEO-RENDERING PERFORMANCE COMPARISON: DELL PRECISION MOBILE WORKSTATIONS VS. APPLE MACBOOK PROS MARCH 2012

COMPLEXITY COMPARISON: CISCO UCS VS. HP VIRTUAL CONNECT

Intel Desktop Board D925XECV2 Specification Update

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

Home Theater PC Chassis

CENTRALIZED SYSTEMS MANAGEMENT: DELL LIFECYCLE CONTROLLER INTEGRATION FOR SCCM VS. HP PROLIANT INTEGRATION KIT FOR SCCM

Minimum Hardware Specifications Upgrades

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

Hydra Super-S Combo. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, v1.3

Small Industries Development Bank of India Request for Proposal (RfP) For Purchase of Intel Servers for Various Locations

Comtrol Corporation: Latency Performance Testing of Network Device Servers

MICROSOFT SHAREPOINT CONSOLIDATION AND TCO: DELL POWEREDGE R720 VS. HP PROLIANT DL380 G7

H ARDWARE C ONSIDERATIONS

EVGA X99 Classified Specs and Initial Installation (Part 1)

ALIENWARE X51 PERFORMANCE COMPARISON: SAMSUNG SSD VS. TRADITIONAL HARD DRIVE

E2437. Motherboard. Troubleshooting Guide Q & First Edition September 2006 Copyright 2006 ASUSTeK COMPUTER INC. All Rights Reserved.

Vendor and Hardware Platform: Fujitsu BX924 S2 Virtualization Platform: VMware ESX 4.0 Update 2 (build )

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE

IMPROVE YOUR SUPPORT EXPERIENCE WITH DELL PREMIUM SUPPORT WITH SUPPORTASSIST TECHNOLOGY

QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview

Cisco 7816-I5 Media Convergence Server

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure

Minimum Hardware Specifications Upgrades

Brainlab Node TM Technical Specifications

Fujitsu PRIMERGY BX600 S3 Blade Server


The Motherboard Chapter #5

JKL Bahweting School. Request for Proposal. VDI Servers

How To Install A Power Supply (Uplast) With A Battery Pack

Genesi Pegasos II Setup

Dell Latitude E6320. Setup and Features Information. About Warnings. Front and Back View

HP ProLiant xw460c Blade Workstation Overview

System Installation. 3-1 Socket 370 Celeron/Pentium-III Processor. Installing S370 CPU. Removing CPU. Configuring System Bus

JUNE 2009 File server performance comparison of three Dell PowerVault NX3000 configurations using Microsoft FSCT

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Intel RAID Controller Troubleshooting Guide

QuickSpecs. HP ProLiant xw460c Blade Workstation. Overview

Compaq Presario Desktop Products. Upgrading and Servicing Guide

StorTrends 3400 Hardware Guide for Onsite Support

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

This Request for Proposal consists of providing the IT Server requirements outlined in this RFP.

Schedule for supply of Server, Multifunction Printer, Laptop, Computer, Monitor and UPS:

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

HP recommended configurations for Microsoft Exchange Server 2013 and HP ProLiant Gen8 with direct attached storage (DAS)

DeltaV Virtualization Hardware

Referencia: Dell PowerEdge SC1430-2GB9L3J Nettó ár: Db: 1 Tag Number: 2GB9L3J

QuickSpecs. What's New. Models. ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. Overview

HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide

Microsoft Windows Compute Cluster Server 2003 Getting Started Guide

Dynamic Power Variations in Data Centers and Network Rooms

TrueAlarm Fire Alarm Systems

HP ProLiant DL165 G7 Server. Installation Instructions

Certification: HP ATA Servers & Storage

Dell Vostro 3350/3450/3550/3750

HP 16/18-Port Cable Management Kit Installation Guide

Cisco MCS 7845-I2 Unified Communications Manager Appliance

How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Cisco MCS 7825-H2 Unified CallManager Appliance


IBM Europe Announcement ZG , dated March 11, 2008

RSA Security Analytics. S4 Broker Setup Guide

Transcription:

Out-of-box comparison between and blade servers TEST REPORT JUNE 2007 Executive summary Inc. () commissioned Principled Technologies (PT) to compare the out-of-box experience of a PowerEdge 1955 Blade System with that of an BladeSystem c-class. We received each chassis and set of blades in the manufacturer's original packaging. We then compared the amount of time it took us to set up each system. Due to differences in packaging and design, there was a considerable difference in setup times for the two systems. KEY FINDINGS The 10-blade PowerEdge 1955 Blade System took 1 hour, 5 minutes, 45 seconds to assemble; the 16-blade BladeSystem c-class took 3 hours, 34 minutes, 15 seconds to assemble--more than three times as long as the system. The PowerEdge 1955 Blade System shipped with the blades already assembled and installed in the enclosure; the BladeSystem c-class arrived unassembled and required us to install a processor, memory, and hard disk in each blade. Figures 1A and 1B show the components of the two server arrays after we unpacked them. These photographs illustrate the difference in the time and effort required to set up the two blade servers. The blades were preconfigured and all necessary components were up and The PowerEdge 1955 Blade System running as soon as we plugged in the enclosure and put in arrived in 2 boxes; the BladeSystem c- the blades. shipped the second processor, extra RAM, Class arrived in 78 boxes. and hard drives separately; the total of 78 boxes made the unpacking and setup time for the blade servers much longer than that for the blade servers. Figure 1A: The equipment immediately after we unpacked it. Figure 1B: The equipment immediately after we unpacked it. Figure 2 summarizes the amount of time we spent unpacking each system, installing it in the server rack, and powering it on. The process for the system took more than three times longer than that for the. PowerEdge 1955 Blade System BladeSystem c-class Task executed Removing items from shipping boxes 13:30 58:45 Installing the server in the rack 47:45 2:30:00 Powering on the system 4:30 5:15 Total time required 1:05:45 3:34:15 Figure 2: Time to unpack, install, and power on both systems. Times are in hours: minutes: seconds. Shorter times are better.

Test results In this section, we detail our experience setting up the PowerEdge 1955 Blade System and the BladeSystem c-class enclosures, from the time each system arrived through our installation of all of its blades in the chassis and the chassis in a server. We discuss this process in the following stages: Receiving the system Removing system components from their packaging o Opening and removing parts from shipping boxes o Removing components and server from outer shipping box o Removing plastic wrap and foam pieces from server o Removing chassis from pallet Installing the system in the server rack o Installing rails and mounting chassis into server rack o Installing blades into chassis o Installing power distribution unit (PDU) and cables Powering on the system For each stage and sub-stage after we received the systems, we enumerate the steps we took, note the amount of time each step took, and provide representative photographs. Receiving the system As Figure 3A shows, the shipment consisted of two boxes: a large box strapped to a pallet and a smaller box. The shipping service delivered both boxes to our second-floor lab. As Figure 3B shows, the shipment consisted of 78 boxes. Upon arrival at our building, the large box was strapped to a pallet and the 77 smaller boxes were attached to a large pallet with plastic wrap. Because the large pallet could not fit into the elevator to our second-floor office, we had to unwrap the pallet in the lobby and make multiple elevator trips to bring the smaller boxes up to our lab. (Note: We did not time the process of transporting the 77 smaller boxes.) Figure 3A: The boxes upon delivery in our lab. Figure 3B: The boxes after we brought them up to our lab. 2

Removing the system components from their packaging Opening and removing parts from shipping boxes 1. Opened and started reading instructions. (1:30) 2. Cut off the straps, then cut through the tape to open the top of the box. (0:30) Total time: 2 minutes 1. Opened the hard disk boxes and placed them on the table. (17:00) 2. Opened the blade server boxes and placed the blade servers on the table. (10:30) 3. Opened the blade kit boxes and placed the processors and heat sinks on the table. (15:00) 4. Opened the RAM box and placed the RAM on the table. (1:45) 5. Opened the Ethernet switch box and placed the switch on the table. (2:00) 6. Opened the fan boxes and placed the fans on the table. (6:00) 7. Opened the PDU boxes and placed items on the table. (3:00) 8. Cut off the straps, then cut through the tape to open the top of the box. (0:30) Total time: 55 minutes, 45 seconds Figure 4A: Opening the server box. Figure 4B: Opening the server box. Removing components and server from outer shipping box 1. Removed the topmost box and set it aside. (0:45) 2. Removed the outermost cardboard covering. (0:30) Total time: 1 minute, 15 seconds 1. Removed the topmost boxes and the template for inserting the enclosure onto the rack and set them aside. (1:15) 2. Removed the foam padding from the top of the server. (0:30) 3. Removed the outermost cardboard covering. (0:30) Total time: 2 minutes, 15 seconds 3

Figure 5A: The server with outer cardboard covering removed. Figure 5B: The server with outer cardboard covering removed. Removing plastic wrap and foam pieces from server 1. Removed the second box and set it aside. (0:30) 2. Removed the foam pieces from the blade system. (1:00) Total time: 1 minute, 30 seconds 1. Removed the corner pieces and set them aside. (0:15) 2. Removed the plastic wrap around the server. (0:30) Total time: 45 seconds Figure 6A: The server with foam pieces removed. The Drive 0, blade 1 drive was partially ejected. Figure 6B: The server with plastic wrap removed. Removing chassis from pallet 1. Opened the top box that we had removed and set aside earlier. (0:45) 2. Removed anti-static sheets from bag and placed them on a table. (1:00) 3. Removed the blades and set them onto anti-static sheets. (4:00) 4. Removed the power supplies. (2:00) 5. Lifted the chassis off the pallet. (1:00) Total time: 8 minutes, 45 seconds 1. Lifted the chassis from the pallet.(2:00) Total time: 2 minutes, 0 seconds 4

Installing the system in the server rack Installing rails and mounting the chassis in the server rack Note: We followed the Getting Started with your System guide to install the chassis in the rack. 1. Removed the two instruction guides from the large box and began reading the Getting Started With Your System Guide. (1:00) 2. Referred to the User s/installation and Troubleshooter s Guide, which contains only information about setting up the operating system and software. (1:00) 3. Switched back to reading the Getting Started with your System Guide. (2:00) 4. Opened the rails box and the power distribution unit box. (1:00) 5. Removed the foam from the rail box and unpacked the rails. (1:00) 6. Unpacked the power cords from the power distribution unit box. (1:15) 7. Read about rail installation.(1:00) 8. Installed the rails into the rack. (6:00) Read the instructions for installing the chassis. (1:00) 9. Installed the chassis onto the rails. (1:00) Total time: 16 minutes, 15 seconds Note: We followed the instructions on the template that was in the chassis box. 1. Removed the template and placed it on the rack. (1:00) 2. Opened the power supply boxes and placed the power supplies on the table. (6:00) 3. Installed screw holders into the rack. (0:45) 4. Installed the rails into the rack. (6:30) 5. Installed the chassis onto the rails. (3:45) Total time: 18 minutes Figure 7A: The chassis installed on the rails. Figure 7B: The chassis installed on the rails. 5

Installing blades and power supplies in the chassis 1. Returned to reading the instructions to install the blades and power supplies. (0:30) 2. Installed the blades and power supplies in the chassis. (5:00) Total time: 5 minutes, 30 seconds 1. Removed the power supply fillers from the chassis. (0:30) 2. Inserted the power supplies into the chassis. (1:45) 3. Referred to the installation poster for the next step. (1:30) 4. Removed the fan fillers from the chassis. (0:45) 5. Installed the fans into the chassis. (1:00) 6. Removed the module filler from the chassis. (0:15) 7. Inserted the onboard administrator module into the chassis. (0:30) 8. Installed the processor, RAM, and hard disks in the first blade server. (10:30) 9. Inserted the first blade server into the enclosure. (0:30) 10. Installed system 2 in the chassis. (8:15) 11. Installed system 3 in the chassis. (7:00) 12. Installed system 4 in the chassis. (6:45) 13. lnstalled system 5 in the chassis. (6:30) 14. Installed system 6 in the chassis. (7:30) 15. Installed system 7 in the chassis. (8:00) 16. Installed system 8 in the chassis. (7:30) 17. Installed system 9 in the chassis. (6:45) 18. Installed system 10 in the chassis. (6:15) 19. Installed system 11 in the chassis. (5:45) 20. Installed system 12 in the chassis. (5:15) 21. Installed system 13 in the chassis. (4:30) 22. Installed system 14 in the chassis. (6:00) 23. Installed system 15 in the chassis. (5:45) 24. Installed system 16 in the chassis. (5:30) Total time: 1 hour, 54 minutes, 30 seconds Figure 8A: The blades installed in the chassis. Figure 8B: The blades and power supplies installed in the chassis. 6

Installing the power distribution unit (PDU) and cables 1. Started reading instructions on installing the keyboard, mouse, and monitor cables. (1:00) 2. Unpacked the keyboard, mouse, and monitor cables and connected them as instructed. (1:00) 3. Attached the management system cables. (1:00) 4. Unpacked and installed the first PDU. (13:00) 5. Installed the second PDU. (7:00) 6. Unpacked and connected the power cords to the back of the unit. (3:00) Total time: 26 minutes, 0 seconds 1. Started reading instructions on installing the PDU. (2:00) 2. Unpacked the first PDU and installed it as instructed. (6:15) 3. Unpacked and installed the second PDU. (4:45) 4. Unpacked and connected the power cords to the back of the unit. (3:00) 5. Unpacked and connected the keyboard, mouse, and monitor cable to the front of the first blade. (1:30) Total time: 17 minutes, 30 seconds Figure 9A: The system with the PDUs installed. Figure 9B: The system with the PDUs installed. Powering on the system Note: For both systems, we followed the manufacturer s User Guide to power up the system. 1. Plugged the unit into an electrical outlet. (1:00) 2. Connected the first Ethernet cable to Bank 1. (0:30) 3. Pressed the power button on each of the server modules. (1:00) 4. Waited while the systems powered up. (2:00) Total time: 4 minutes, 30 seconds 1. Plugged the unit into an electrical outlet. (1:00) 2. Connected the first Ethernet cable to Bank 1. (0:30) 3. Waited while all systems powered up. (3:45) Total time: 5 minutes, 15 seconds 7

Test methodology We attempted to recreate the way a typical buyer would set up a chassis of blade servers. We generally followed the instructions the vendors provided in their packaging. Occasionally, such as when we were opening the boxes, we had to use our own judgment, but whenever possible, we followed the vendors instructions. As one person executed the tasks, another person documented the process by recording the steps, timing each step, and photographing as many steps as possible. 8

Appendix A Enclosure configuration information This appendix provides detailed configuration information about the enclosures, which we present in alphabetical order. PowerEdge 1955 Blade Enclosure System BladeSystem c-class General dimension information Height (inches) 12.0 17.5 Width (inches) 17.5 17.5 Depth (inches) 29.0 31.0 U size in server rack 7 10 Number of blades 10 16 Power supplies Total number 4 6 Wattage of each 2100 2250 Cooling fans Total number 4 10 Dimensions (H x W) of each 5.5 x 5.5 3.5 x 3 Voltage 24 volts 12 volts Amps 2.3 amps 16.5 amps 9

Appendix B Blade system configuration information This appendix provides detailed configuration information about the blade server systems, which we present in alphabetical order. PowerEdge 1955 blade Servers server ProLiant BL460c General processor setup Number of processor packages 2 2 Number of cores per processor package 4 4 Number of hardware threads per core 1 1 System Power Management Policy Always On Always On CPU Vendor Intel Intel Name Quad-Core Intel Xeon processor X5345 Stepping 7 7 Socket type LGA 771 LGA 771 Core frequency (GHz) 2.33 GHz 2.33 GHz Front-side bus frequency (MHz) 1333 MHz 1333 MHz L1 Cache 32 KB + 32 KB (per core) 32 KB + 32 KB (per core) L2 Cache 2 x 4MB (each 4MB shared by 2 cores) Quad-Core Intel Xeon processor X5345 2 x 4MB (each 4MB shared by 2 cores) Platform Vendor and model number PowerEdge 1955 ProLiant BL460c Motherboard model number 0MY759 435458-B21 Motherboard chipset Intel 5000P Intel 5000P Motherboard revision number A00 91 BIOS name and version 1.1.0 10/18/2006 I15 12/26/2006 BIOS settings Disabled Hardware Prefetcher and Adjacent Cache Line Prefetch Disabled Hardware Prefetcher and Adjacent Cache Line Prefetch Chipset INF driver 7.3.0 2.1.8 Memory module(s) Vendor and model number Hyundai HYMP512F72BP8N3-Y5 Micron MT18HTF12872FDY Type PC2-5300 PC2-5300 Speed (MHz) 667 MHz 667 MHz Speed in the system currently running 667 MHz 667 MHz @ (MHz) Timing/Latency (tcl-trcd-irptrasmin) 5-5-5-15 5-5-5-15 Size 4 GB (4 x 1GB) 4 GB (4 x 1GB) Number of RAM modules 4 4 Chip organization Dual side Dual side 10

PowerEdge 1955 blade Servers server ProLiant BL460c Hard disk Vendor and model number Fujitsu MAY2073RC Seagate St973402SS Number of disks in system 2 2 Size 73 GB 72 GB Buffer Size 16 MB 16 MB RPM 10,000 10,000 Type SAS SAS Controller SAS 5/iR Integrated controller Smart Array E200I controller Controller driver 1.21.8.0 6.6.0.64 Operating system Name Microsoft Windows Server 2003, Microsoft Windows Server 2003, Enterprise Edition Enterprise Edition Build number 3790 3790 Service Pack SP 2 SP 2 Microsoft Windows update date SP 2 only SP 2 only File system NTFS NTFS Kernel ACPI Multiprocessor-based PC ACPI Multiprocessor-based PC Language English English Microsoft DirectX version 9.0c 9.0c Graphics Vendor and model number ATI ES1000 ATI ES1000 Chipset ATI ES1000 ATI ES1000 BIOS version BK-ATI VER008.005.028.000 BK-ATI VER008.005.013.000 Type Integrated Integrated Memory size 16MB 32MB Resolution 1024 x 768 1024 x 768 Driver ATI 8.19.4.0 ATI 8.24.3.0 Network card/subsystem Vendor and model number Broadcom BCM5708S NetXtreme NC373i Multifunction Gigabit II Gigabit Ethernet adapter Server Adapter Type Integrated Integrated Driver Broadcom 2.6.14.0 3.0.5.0 Optical drive Vendor and model number None installed None installed USB ports Number 2 (with adapter attached) 2 (with adapter attached) Type USB 2.0 USB 2.0 11

Principled Technologies, Inc. 1007 Slater Rd., Suite 250 Durham, NC 27703 www.principledtechnologies.com info@principledtechnologies.com Principled Technologies is a registered trademark of Principled Technologies, Inc. All other product names are the trademarks of their respective owners Disclaimer of Warranties; Limitation of Liability: PRINCIPLED TECHNOLOGIES, INC. HAS MADE REASONABLE EFFORTS TO ENSURE THE ACCURACY AND VALIDITY OF ITS TESTING, HOWEVER, PRINCIPLED TECHNOLOGIES, INC. SPECIFICALLY DISCLAIMS ANY WARRANTY, EXPRESSED OR IMPLIED, RELATING TO THE TEST RESULTS AND ANALYSIS, THEIR ACCURACY, COMPLETENESS OR QUALITY, INCLUDING ANY IMPLIED WARRANTY OF FITNESS FOR ANY PARTICULAR PURPOSE. ALL PERSONS OR ENTITIES RELYING ON THE RESULTS OF ANY TESTING DO SO AT THEIR OWN RISK, AND AGREE THAT PRINCIPLED TECHNOLOGIES, INC., ITS EMPLOYEES AND ITS SUBCONTRACTORS SHALL HAVE NO LIABILITY WHATSOEVER FROM ANY CLAIM OF LOSS OR DAMAGE ON ACCOUNT OF ANY ALLEGED ERROR OR DEFECT IN ANY TESTING PROCEDURE OR RESULT. IN NO EVENT SHALL PRINCIPLED TECHNOLOGIES, INC. BE LIABLE FOR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH ITS TESTING, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL PRINCIPLED TECHNOLOGIES, INC. S LIABILITY, INCLUDING FOR DIRECT DAMAGES, EXCEED THE AMOUNTS PAID IN CONNECTION WITH PRINCIPLED TECHNOLOGIES, INC. S TESTING. CUSTOMER S SOLE AND EXCLUSIVE REMEDIES ARE AS SET FORTH HEREIN. 12