Fire Safety Log Book



Similar documents
FIRE SAFETY RECORD OF TESTS LOGBOOK

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

Fire Safety logbook

Greater Manchester Fire and Rescue Service

Fire Safety Log Book. Premises Name: Premises Address: Date From: Date To: Location of Log Book:

FIRE SAFETY REGISTER. Premises Name: Premises Address: Fire Safety Manager: Contact No. Kerry County Fire Service

Fire Log Book. Provided by Norfolk Fire & Rescue Service. Name and address of premises:...

Fire Safety Log Book

FIRE SAFETY PRECAUTIONS

FIRE SAFETY RISK ASSESSMENT

The terms hazard and risk are often used, which we define as the following:

Fire Safety Log Book

FIRE DETECTION AND ALARM SYSTEMS

Bastille Court 2 Paris Garden London SE1 8ND Telephone: Fax: training@thefpa.co.uk Web:

For use by landlords of small premises Premises Address

1.1.4 The findings from Fire Risk Assessment must be incorporated into the FRAMS Action Plan to manage fire safety at each premise.

1.0 APPOINTMENTS 2.0 FIRE RISK ASSESSMENTS

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Fire Policy and Procedures. Cañada Blanch Spanish School

False Alarm/Unwanted Fire Signals Reduction Guidance

1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

How To Write A Fire Risk Assessment

Course of Construction Questionnaire

Reducing false alarms

CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY

1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.

Fire Risk Assessment For Simple Premises

FIRE RISK ASSESSMENT

Fire safety advice for landlords

For use by landlords of small premises Premises Address

REGULATORY REFORM (FIRE SAFETY) ORDER Fire Risk Assessment. 145 Drury Lane Covent Garden London WC2B 5TA

Workplace Fire Safety

Call reduction guidance for false alarm/ unwanted fire signals

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

NORTH BIRMINGHAM ACADEMY

Guidance for Electrical Contractors on Emergency Lighting Legislation

section 2 Moving into your new home Auld School Wynd, Cambusbarron

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

CATERING CONTRACTORS General Code of Safety Practice

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

FIRE RISK ASSESSMENT. The Workplace Fire Precautions Legislation

Fire Alarm Systems Care and Maintenance

Fire Safety Requirements for Child Care Centre

Fire Risk Assessment Safety Checklist

Fire Safety Risk Assessment Checklist for Residential Care Premises

Fire risk assessment a guide for businesses

Fire precautions in dwellings. Private sector housing Providing homes building communities

Fire Safety Challenges and Solutions. Claire Guise Health and Safety Manager

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION

WORKING IN CONFINED SPACES GUIDELINES

FIRE ALARMS. IN DWELLINGS By John Ware FIRE ALARMS

Grasshoppers Rugby Football Sports and Social Club. The Fire Risk Assessment

To promote and protect the private residential landlord. Fire Safety Logbook. Information. Advice. Support. Services START DATE:

Fire safety and fire risk assessment

CFP 2/4/8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL. user manual & log book. Approved Document No. DFU Rev 1

RISKSTOP CONTROLLING RISKS IN UNOCCUPIED COMMERCIAL PROPERTIES

FIRE RISK ASSESSMENT SW13 0HA

Fire Risk Assessment for Simple Premises Guidance Notes

PRACTICAL FIRE SAFETY GUIDANCE FOR EDUCATIONAL AND DAY CARE FOR CHILDREN PREMISES

Protection of unoccupied or void properties

Action required (Please tick) If you answered YES, record Action Points at STEP 4

NEW FIRE SAFETY LEGISLATION

Inspection, Testing and Maintenance

SBR FIRE RISK ASSESSMENT

Safety in Offices and other General Areas

FIRE RISK ASSESSMENT WORKED EXAMPLE

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

BRO Roles & Responsibilities Form Page 1 of 9

FLA S FIRE SAFETY INITIATIVE

Important Ontario Fire Code Information for Building Owners in the City of Windsor

FIRE SAFETY POLICY GUIDANCE

Fire Evacuation Procedures Network Building, 97 Tottenham Court Road, London, W1

Your responsibilities if you have an automatic fire alarm. A handy guide for owners and responsible persons

FIRE RISK ASSESSMENT

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

LANCASTER UNIVERSITY. MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS

Fire Safety Policy. Fire Safety Policy: May 2011 Page 1 of 6. Version 1. Scope:

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

FIRE SAFETY GUIDANCE NOTE Regulatory Reform (Fire Safety) Order 2005

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

FIRE SAFETY IN THE HOME

BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010

HARDWIRED CONTROL PANELS

Safety and Health Office WORKPLACE SAFETY CHECKLIST

Caravan Sites and Control of Development Act Permanent Residential Mobile Home Sites Licence Conditions

Guidance Document on SELECTION AND SPECIFICATION OF FIRE ALARM CATEGORY IN ACCORDANCE WITH BS

Lee Baron FIRE RISK ASSESSMENT

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

Safety and Environmental Information for External Companies

User s Guide. Security Systems D220

Transcription:

Fire Safety Log Book Company... Address........ Responsible Person. Competent Person. Date Started For Additional Information: Safety Management (UK) Ltd Holme Suite, Clawthorpe Hall Business Centre, Burton in Kendal, LA6 1NU Tel: +44 (0)1524 784356 e-mail info@safety-managementuk.com

LOG BOOK INTRODUCTION This log book is designed to assist you in complying with the Regulatory Reform (Fire Safety) Order 2005 with the recording the testing of fire safety features and equipment contained within your premises along with a programme of fire safety training for your staff. The information contained is for your guidance only and should form part of your fire risk assessment, also required by the Regulatory Reform (Fire Safety) Order 2005: The Log Book will guide you as to the current intervals of Inspection and Maintenance for the Equipment and Fire Safety Training General Fire Safety Staff Training Visiting Enforcing Authorities Fire Risk Assessment Fire Alarm Systems CONTENTS OF LOG BOOK Fire Instructions and Drills Record of Instruction and Drills Fire Extinguishers Record of Test and Inspections Hose Reels Emergency Lighting Record of Tests and Inspections Miscellaneous Equipment Record of Tests Escape Route Audits USEFUL TELEPHONE NUMBERS Name Company Tel No Mobile No

GENERAL FIRE SAFETY HEATING Keep boiler houses clear- do not use them as an extra storeroom. Keep portable heating appliances away from furniture and any combustible materials. SMOKING MATERIALS Be vigilant in areas where people smoke and provide adequate ashtrays. Before leaving rooms which will be unoccupied for long periods, or in which persons will be sleeping, make a final check for any cigarette ends. These may have fallen into the recess of an armchair, on the carpet or on the bedclothes when someone fell asleep. Always empty ashtrays. WHEN YOU CLOSE DOWN Go round the premises at the end of the working day or end of a shift. Check that electrical appliances are switched off and that there are no smouldering cigarette ends. Close all doors and windows so that if, in spite of all your precautions, a fire does break out, it will be confined in a small area. Lock up securely GENERAL FIRE SAFETY Be aware of the common fire causes Electricity Rubbish Smoking Heaters Dangerous Goods Arson Hot Work It is a source of heat. Get faults repaired immediately by a competent electrician. Do not overload sockets. Switch off appliances after use. Fire loves rubbish. Get it out of the premises and into metal bins (with lids) away from the building as quickly as possible. Still the most frequent fire starter. Consider instigating a "No Smoking" policy. Portable heaters start fires if not placed carefully and used wisely. Some cleaning materials and aerosols are either flammable or explosive. Keep them all well away from any source of heat. The careful use and storage of any flammable liquid or gas is essential to maintain a safe working environment. Help to protect your premises from the arsonist by locking away any flammable liquids or gases. Secure your premises at the end of the day, including doors or windows that are easily missed. Activities such as welding, flame cutting, use of blow lamps or portable grinding equipment can pose a serious fire hazard and need to be strictly controlled when carried out in areas near flammable materials. This can be done by having a written permit to work for the people involved (whether they are employees or a contractor). IN THE EVENT OF A FIRE Make sure your staff know: How to raise the alarm and call the Fire and Rescue Service (place written instructions in prominent places); How to use fire extinguishers; Where the escape routes and assembly points are.

STAFF TRAINING FIRE DRILLS Should be carried out at the interval shown below and conducted to simulate fire conditions; i.e. one route obstructed. No advance warning should be given, other than to specific staff for purposes of safety and the avoidance of a false call being made to the Fire and Rescue Service. SIX MONTHLY In residential premises, places of entertainment, large shops and department stores. YEARLY In industrial and commercial premises. Date Nature of Drill Persons/Sections Taking part Evacuation Time Person in Charge

Date Nature of Drill Persons/Sections Taking part Evacuation Time Person in Charge

VISITS BY FIRE SAFETY OFFICER / ENFORCING AUTHORITY Date Inspecting Officer (Print) Officer s Comments

FIRE RISK ASSESSMENT A Fire Risk Assessment is an organised look at what, in your work activities and workplace, could cause harm to people. This will allow you to weigh up whether you have taken enough precautions or you should do more to avoid them. The important things you need to decide are whether a hazard is significant and whether you have covered it by satisfactory precautions so that the risk is acceptably low. What do the terms "hazard" and "risk" mean? A hazard is something that has the potential to cause harm. A risk is the chance, high or low, of that harm occurring. Before you start your risk assessment Regardless of any previous approval, (Fire Certificate, licensing or building legislation) you still need to carry out a fire risk assessment. However, if the previous approval covered all the matters required by the Fire Regulations, and conditions have remained unchanged, e.g. numbers of people present, work activity etc., then your fire risk assessment may well show that few, if any, additional precautions are needed. Your risk assessment may identify additional matters which need addressing if the previous approval was given according to an out of date standard of fire precautions, or the approval was under legislation which does not cover all the requirements of the Fire Regulations. If you are not sure, the fire authority will be able to advise you. How do you do a fire risk assessment? A fire risk assessment will help you determine the chances of a fire occurring and the dangers from fire that your workplace poses for the people who use it. The assessment method suggested shares the same approach as that used in general health and safety legislation and can be carried out either as part of a more general risk assessment or as a separate exercise. For fire risk assessments there are five steps that you need to take Step 1 Identify potential fire hazards in the workplace. Step 2 Decide who (e.g. employees, visitors) might be in danger, in the event of a fire, in the workplace or while trying to escape from it, and note their location. Step 3 Evaluate the risks arising from the hazards and decide whether your existing fire precautions are adequate or whether more should be done to get rid of the hazard or to control the risks (e.g. by improving the fire precautions). Step 4 Record your findings and details of the action you took as a result. Tell your employees about your findings. Step 5 Keep the assessment under review and revise it when necessary. If your workplace is in a building shared with other employers, you and all the other occupiers and any other person who has control of any other part of the workplace will need to discuss your risk assessments. This will help to ensure that any areas of higher risk, and the need for any extra precautions, are identified.

FIRE RISK ASSESSMENT Assessment Date Person Carrying Out Assessment Date Action Plan Compiled Person Compiling Action Plan Next Assessment Date

FIRE ALARM SYSTEM Fire Alarm (for further information refer to the current British Standard (5839) It is important that the operations of testing do not result in a false signal of fire. Daily inspect the panel for normal operation of the system. When provided, check that the connection to the remote manned centre is functioning correctly. Record any defect in the log book and report it to a responsible person. Weekly test and examination to ensure that the system is capable of operating under alarm conditions, namely: (a) Operate trigger device (manual call point or detector) or end of line switch on a zone circuit. Zones should be tested in strict rotation, each zone is being tested quarterly for a monitored system and weekly for an un-monitored system. Each time a zone is tested a different trigger device should be used. (b) Examination of batteries and connections including electrolyte level. Quarterly and annual inspection and test. No guidance is given as these should be done by the installer, or an employee who has received special training by the installer. 5 yearly wiring check I.E.E. Wiring Regulations. FIRE DETECTORS (for further information refer to the current British Standard (5839) Regular visual inspection of detectors for damage, unusual accumulations of dirt, heavy coats of paint and other conditions likely to interfere with the correct operation of the detector. Annual test of at least 2% of installed heat detectors by application of a heat source as a check on reliability. Detectors other than heat should be checked for correct operation and sensitivity in accordance with the manufacturer's instruction. AUTOMATIC DOOR RELEASES CONNECTED TO THE FIRE ALARM SYSTEM Weekly, in conjunction with the fire alarm test, check that all doors are being released and closing onto the door rebates. RECORD OF TEST FIRE ALARM SYSTEM Date Fire Alarm Automatic Door Releases Automatic Detector Remedial Action Taken Call point location or number Satisfactory Location or Number Satisfactory

FIRE ALARM SYSTEM RECORD OF TEST Date Fire Alarm Automatic Door Releases Automatic Detector Remedial Action Taken Call point location or number Satisfactory Location or Number Satisfactory

FIRE INSTRUCTIONS AND DRILLS FIRE INSTRUCTIONS At intervals shown below instruction should be given in respect of the action, purpose etc., of the following : Discovering a fire, hearing the fire alarm, the assembly point, calling the fire and rescue service, making safe power supplies etc., use of fire alarms and fire extinguishers, and the means of escape routes. First month of employment - two instruction periods. Three monthly for staff on night duties. Six monthly for staff on day duties or as determined by your fire risk assessment. FIRE DRILLS At intervals shown below drills should be conducted to stimulate fire conditions i.e., one escape route obscured, no advance warning given other than to specific staff for the purposes of safety, the fir alarm should be operated on instructions of management. Do not call the fire & rescue service for the purposes of a drill, it is an offence. Six monthly for residential premises, places of public entertainment, large shops and departmental stores. Yearly for industrial and commercial premises. RECORD OF FIRE INSTRUCTIONS AND DRILLS FIRE INSTRUCTIONS AND DRILLS Date Instruction Detail Fire Drill Evacuation Time Person Receiving Instruction/Drill Remarks of Instructor

RECORD OF FIRE INSTRUCTIONS AND DRILLS FIRE INSTRUCTIONS AND DRILLS Date Instruction Detail Fire Drill Evacuation Time Person Receiving Instruction/Drill Remarks of Instructor

FIRE EXTINGUISHERS FIRE EXTINGUISHERS (for further information refer to the current British Standard (5306) Monthly inspection to ensure that they are in their proper position and have not been discharged, or lost pressure (those fitted with pressure indicator), or suffered obvious damage. Annual inspection. No guidance is given as this should be done preferably by a representative of the manufacturer, or at least by a competent person following the manufacturer's recommended procedures and using the tools etc., specified therein. At intervals not exceeding those detailed in the above British Standard. Spare cartridges should be obtained in advance and testing should b programmed throughout the year, etc., (an ideal opportunity for staff training). An annual inspection should be done during test, (see above). RECORD OF TESTS AND INSPECTION FIRE EXTINGUISHERS Date Location or Number Inspected or Tested Satisfactory Remedial Action Taken

RECORD OF TESTS AND INSPECTION FIRE EXTINGUISHERS Date Location or Number Inspected or Tested Satisfactory Remedial Action Taken

HOSE REEL HOSE REELS (for further information refer to the current British Standard (5306) Regular inspections for leaks and correct operation. Annual test when the hose should be completely run out and subjected to operational water pressure to ensure that the hose is in good condition and that all couplings are watertight. A flow test should be carried out to ensure that a discharge of at least 24 litres/minute is achieved at the two highest hose reels. RECORDS OF TEST AND INSPECTION HOSE REELS Date Location or Number Inspected or Tested Satisfactory Remedial Action Taken

EMERGENCY LIGHTING; LUMINARIES AND STANDBY BATTERIES EMERGENCY LIGHTING: (for further information refer to the current British Standard (5266) Because of possible failure all tests should be undertaken at times of least risk. Regularly inspect the system for cleanliness, particularly luminaries. Battery banks and generators should be checked following the manufacturer's instructions. Daily test - check that any previous faults have been rectified, that every lamp in a maintained unit is lit, that the control panel indicates normal. Ensure any fault found is recorded in the log book and acted upon. Monthly test of self contained luminaries, by simulation of a failure of the normal lighting supply, for sufficient time to allow all luminaries to be checked for proper function. Six monthly test of self contained and central battery systems, by simulation of a failure of the normal lighting supply for a continuous period of 1 hour for 3 hour duration units and 15 minutes for 1 hour units. During the test check all luminaries for proper function. Three yearly test for full duration of self-contained and central battery systems which have specified duration category in excess of one hour. During the test check all luminaries for proper function. EMERGENCY LIGHTING; LUMINARIES AND STANDBY BATTERIES RECORDS OF TESTS AND INSPECTIONS Date Location or Number Inspected or Tested Satisfactory Remedial Action Taken

EMERGENCY LIGHTING; LUMINARIES AND STANDBY BATTERIES RECORDS OF TESTS AND INSPECTIONS Date Location or Number Inspected or Tested Satisfactory Remedial Action Taken

MISCELLANEOUS EQUIPMENT RECORD OF TESTS Date Item Tested Satisfactory Remedial Action Taken

ROUTES OF ESCAPE ALL routes of escapes in case of fire are to be kept clear at ALL times. Date Result of Test and Action Taken