Calibration of flow meters for liquids and gases



Similar documents
RITTER Multiple Sonic Nozzle Calibration System


Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

Advances in Thermal Dispersion Mass Flow Meter Accuracy

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

FLUXUS Energy. Manage energy effectively using non-invasive measuring technology. Heat usage, chilled flows and compressed air flow rate

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Rules for Classification and Construction Additional Rules and Guidelines

Establishment of the Gas Flow Calibration Facility at CSIR-NPL, India

Testing methods applicable to refrigeration components and systems

ABB Flowmeters Review of industrial processing flowmeters

COMBIMASS. Technical Data COMBIMASS eco-bio +

Pressure regulating valve with modulating kit, type DRV

How To Test A Titrette And Digital Burette

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

UPM Figure 1 MPFM installed on well pad

4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Thermal Dispersion Mass Flow

FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas

(51) Int Cl.: G10L 15/26 ( )

Take total control of your HVAC system with cost-saving flow and thermal energy meters

In semiconductor applications, the required mass flows

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Energy and Flow Measurement for Hydronic Systems

T 300 Tray sealer. Automatic tray packaging in the smallest of spaces

Test equipment for temperature and its reduction

Overflow valve with thread connection

Automatic Back-Flushing Filter AutoFilt RF9.

INTERACTION OF LIQUID MOTION ON MOBILE TANK STRUCTURE

Colour splash. Explore the possibilities. Advertising / Werbemittel

Flow System Calibration in Medical and Bio-medical Production Processes.

Embedded Software Development and Test in 2011 using a mini- HIL approach

APPLICATION FOR ADMISSION For further information please visit our website

A basic introduction to steam

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

Flow Sensors. - mass flow rate - volume flow rate - velocity. - stream line parabolic velocity profile - turbulent vortices. Methods of measurement

Semantic Web. Semantic Web: Resource Description Framework (RDF) cont. Resource Description Framework (RDF) W3C Definition:

Plant components, selected for sound performance

The Radon Calibration Laboratory at the Federal Office for Radiation Protection (BfS)

Measurement and Calibration

Radial piston pumps type R and RG

FLUID FLOW Introduction General Description

Using meters to measure steam flow

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Battery Powered Thermal Mass Flow Meters for Gases

GOOD PRACTICE GUIDE THE CALIBRATION OF FLOW METERS

Instantaneous safety gear RF braking downwards

Methodology for Liquid Ultrasonic Flow Measurement within the Laminar to Turbulent Transitional Zone

Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability

Big Data Vendor Benchmark 2015 A Comparison of Hardware Vendors, Software Vendors and Service Providers

Pressure calibration equipment

The Unique Accelabar Flow Meter

The Fundamentals of Gas Flow Calibration

22. April 2010 Siemens Enterprise Communications

(51) Int Cl.: H04L 12/24 ( ) G06F 9/445 ( )

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Gas Flow Measurement Software A Report for

Unit 24: Applications of Pneumatics and Hydraulics

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

How To Use The Melag Therm 10

Typical Aluminum GFM Mass Flow Meter

Examples for Heat Exchanger Design

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Energy Systems Engineering Technology

ME 538: Experiment # 1 Flow measurement and particle generation instruments

Titrette. class A precision. The next generation Digital Burette!

Gas Custody Transfer Calibration

Operating Instructions

Achim Beisiegel Fouad El-Rharbaoui Michael Wich. AREVA GmbH, Technical Center, Karlstein, Seligenstädter Strasse 100, Germany

Vacuum drying oven for non-flammable solvents

Integrated Custom Systems

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

Correlations for Convective Heat Transfer

Airplane wing test stand for simulating the airstream. Airbus Deutschland GmbH

wie Ihnen mit Sicherheit bereits bekannt ist, ist die Global Aviation + Piper Parts GmbH Distributor der ELT s von Artex.

Unit 24: Applications of Pneumatics and Hydraulics

User s Manual Laminar Flow Elements

Hydraulic control unit series

DOUBLE BLOCK AND BLEED VALVES

Turbine Flowmeter Vision 1000 Flowrates 0,1-2,5L/min. Turbine Flowmeter Vision 2000 Flowrates 0,5-35L/min

Influence of material data on injection moulding simulation Application examples Ass.Prof. Dr. Thomas Lucyshyn

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

Flow Measurement in Pipes and Ducts. Flow Measurement in Pipes and Ducts, Course #503. Presented by:

Spetec. Laminar Flow Box. Portable Clean Room Technology

HYPO TIROL BANK AG. EUR 5,750,000,000 Debt Issuance Programme (the "Programme")

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Search Engines Chapter 2 Architecture Felix Naumann

109 Adopted:

Hydraulic Control Technology for Wind Turbine Generators

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

(51) Int Cl.: B29C 41/20 ( ) F21S 4/00 ( ) H05K 3/28 ( )

Transcription:

Calibration of flow meters for liquids and gases Testo Industrial Services More certainty, better service. www.testotis.com

Flow rate calibration Calibration of flow meters Due to the requirements of a constant product quality, safety, process optimization and environmental protection, industrial flow rate measurement is becoming increasingly important. Because of the wide range of flow rate devices, measuring principles and fluids, a standard measuring technique is rarely suitable. Consequently, an individual solution is also required for the calibration. In our calibration laboratory for flow meters we conduct calibrations of devices independent of manufacturer and fluids. As one of the leading calibration service provider in Europe, we have specialized in high-precision and customized calibrations. Our expertise our promise of quality Our flow calibration team has several years of experience. The combination of unique know-how and the most modern measurement techniques ensure reliable results and smooth processing of your flow rate calibrations. Christian Knapp, Business Unit Manager for flow rate: With almost 25 years of experience in the field of flow rate calibration, I am particular pleased to establish the laboratory in Munich/Dachau as a competence center with Testo Industrial Services. With the enlargement of our laboratories, the extension of the accreditations as well as the expansion of the increasing number of employees, we have become your single-sourcing-provider for flow meters.

Flow rate calibration Large measuring range with minimal measurement uncertainties Our laboratory in Dachau near Munich has more than 950 m2, so we have ideal conditions for the calibration of your flow meter regardless of the manufacturer. The DAkkS calibration procedures are accredited according to DIN EN ISO 17025. This means that your measuring devices are being calibrated with the highest accuracy. The versatility of the test equipment requires a wide spectrum of measuring equipment and calibrators. In order to meet the complex range of flow meter devices, we have six customized test benches. This enables a quick calibration of various flow rates and fluids. Measuring ranges of the calibrations Flow meter for liquids: < 0,8 ml/min up to 1.200 l/min* Flow meter for gases: from approx. 1 ml/min up to 2.000 l/min (ISO up to 18.000 l/min) Calibrators and measuring uncertainties of the calibration procedure Four test benches for liquids with different viscosity and a measuring uncertainty 0,05 % of the actual rate Two test benches for different kind of gases with a measuring uncertainty 0,22 % of the actual rate Applying the liquid calibrations for flow meters we do not calculate the viscosity of the fluid, but we generate the viscosity of a liquid (up to 1.600 mm²/s) according to your requirements. Therefore the calibration can also be conducted with for example alcohol or various oils as well as water.

Flow rate calibrators and calibration ranges at a glance Piston calibrator < 0,8 ml/min 40 l/min Piston calibrator 10 ml/min 200 l/min Piston calibrators (2x) 20 ml/min 1.200 l/min All four liquid calibrators are based on the volumetric measurement procedure with density measurement for mass conversion. The actual fluid pressure can be varied between 1 to 12 bar and at a standard temperature of approximately 20 C. Piston calibrator KKF 80 < 0,8 ml/min 40 l/min Piston calibrator KKF 150 10 ml/min 200 l/min Piston calibrators KKF 200 20 ml/min 1.200 l/min The liquid calibrator for small flow rates is characterized by its unique piston construction, which ensures a minimal friction loss during the calibration. This enables measurements of smallest flow rates. The measuring range of the middle calibrator includes flow rates of 10 ml/min up to approximately 200 l/min. Two identical test benches enable the permanent calibration of various liquids (viscosity up to approximately 1.600 mm 2 /s). The regulation takes place by a numerous number of valves. By this a very large measuring range can be achieved. Individual calibration of your flow meter We can calibrate your flow meter (for liquids) with different fluids. Thereby we generate the viscosity according to your specifications.

Gas calibrators and calibration ranges at a glance Test bench laminar flow element (LFE) 1 ml/min 1.000 l/min Test bench critical nozzles 5 l/min 18.000 l/min Weitere Prfstände bereits in Planung: Bis zum Jahr 2016 werden insgesamt acht Prfstände in dem Kalibrierlabor am Standort Dachau installiert. Außerdem werden die Test Kalibriereinrichtungen bench laminar flow in einem LFGweiteren Schritt Test bench Flexibilisiert critical und venturis das Dienstleistungsportfolio KDG um Kalibrierungen bei Temperaturen 1 ml/min 20 C erweitert. 1.000 l/min Ebenfalls (standard ist der Ausbau 5 l/min der Vor-Ort 18.000 Kalibrierungen l/min (standard sowohl ISO als auch DAkkS geplant. range) range) Im zweiten Halbjahr 2015 wird das aktuelle Prfstandsportfolio um einen gravimetrischen Flssigkeitskalibrator ergänzt. Fr die Volumenrechnung The test bench enables wird die the Dichte calibration des Messmediums A total of bei ten bis pneumatic zu 4 bar ermittelt. actuated Der Messbereich des gravimetrischen Prfstands of flow erstreckt meters sich for air von and 2t/h inert bis gases. ca. 240 t/h. Die critical angestrebte venturis are Messunsicherheit installed in the test fr das Messmedium Wasser ist kleiner 0,1% (k=2). The capillaries inside the individual bench for gas flow meters. Thereby the elements provide a laminar flow of an calibration of very small up to very large Der otherwise achte Prfstand, turbulent die flow Kalibrierglocke, rate. wird Anfang flow rates 2016 at a in pressure Betrieb genommen. of up to 12 bar Die volumetrische Messweise ermöglicht die Kalibrierung von fr unterschiedliche (Misch-) is Gase. possible. Die Kalibrierung wird bei atmosphärischem Druck mit einer Messunsicherheit kleiner 0,35% (k=2) durchgefhrt. Der Messbereich der Kalibrierglocke umfasst 1l/min bis ca. 600 l/min. Further test benches are already in the planning phase Our current calibration portfolio is constantly being expanded. Please contact Sales International for further information about the current planning

Various possibilities of the flow rate calibration Volume flow rate Mass flow rate Magnetic-inductive flow meter Variable area meter Ultra sonic flow meter etc. Coriolis mass flow meter Thermal mass flow meter Vortex flow meter etc. Effective pressure Positive displacement flow meters Orifice flowmeter Dynamic pressure probe Venturi etc. Gear meter Piston flow meter Bellow-type gasmeter Helical flow meter Vane meter Swash plate Oval gear meter etc. Calibration ranges: Visual inspection Cleaning (if required) Technical inspection of the device functions Calibration certificates with set and actual values as well as measuring uncertainties Calibration label Optional services: Programming Linearisation Scaling Adjustment Repair

Your advantages: Independent manufacturer calibrations with short cycle times The spectrum of test benches enables very wide measuring ranges for your calibrations With a short cycle time you receive your measuring devices back quickly for operation. On request express service of 48 hours is also possible Our vendor independence guarantees the necessary objectivity and a single-sourcing-strategy More safety by highly accurate results You receive highly accurate calibration results: Testo Industrial Services is a conformity assessment body accredited by DAkkS according to DIN EN ISO / IEC 17025: 2005. The accreditation is valid as listed in the Accreditation Certifcate D-K-15070-01-08. On request, the certificates include a declaration of conformity PRIMAS The web-based test equipment management system PRIMAS enables you access to your calibration certificates at any time.

Testo industrial services GmbH Gewerbestraße 3 79199 Kirchzarten GERMANY Fon +49 7661 90901-8000 Fax +49 7661 90901-8010 E-Mail info@testotis.com www.testotis.com Direct to www.testotis.com: